Atomic force microscopy imaging using a tip-on-chip: Opening the door to integrated near field nanotools

We describe in detail how atomic force microscopy (AFM) images can be routinely achieved with macroscopic silicon-based chips integrating mesoscopic tips, paving the way for the development of new near field devices combining AFM imaging with any kind of functionality integrated on a chip. The chips have been glued at the end of the free prong of 100 kHz quartz tuning forks mounted in Qplus configuration. Numerical simulations by modal analysis have been carried out to clarify the nature of the vibration modes observed in the experimental spectra. It is shown that two low frequency modes can be used to drive the system and scan the surface with a great stability in amplitude modulation as well as in frequency modulation AFM under ultrahigh vacuum. The AFM capabilities are demonstrated through a series of examples including phase and dissipation contrast imaging, force spectroscopy measurements, and investigations of soft samples in weak interaction with the substrate. The lateral resolution with the tips grown by focused ion beam deposition already matches the one achieved in standard amplitude modulation mode AFM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Resistance, High-Yield Electrical Contacts to Atom Scale Si:P Devices Using Palladium Silicide

Scanning tunneling microscopy (STM) enables the fabrication of two-dimensional δ-doped structures in Si with atomistic precision, with applications from tunnel field-effect transistors to qubits. The combination of a very small contact area and the restrictive thermal budget necessary to maintain the integrity of the δ layer make developing a robust electrical contact method a significant challenge to realizing the potential of atomically precise devices. We demonstrate a method for electrical contact using Pd 2 Si formed at the temperature of silicon overgrowth (250 °C), minimizing the diffusive impact on the δ layer. Here, we use the transfer length method to show our Pd 2 Si contacts have very high yield (99.7% +0.2% –1.5%) and low resistivity (272 ± 41 Ω μm) in contacting mesa-etched Si:P δ layers. We also present three terminal measurements of low contact resistance (<1 kΩ) to devices written by STM hydrogen depassivation lithography with similarly high yield (100% +0% –3.2%).

2-dimensional systems↗

In-situ piezoresponse force microscopy cantilever mode shape profiling

The frequency-dependent amplitude and phase in piezoresponse force microscopy (PFM) measurements are shown to be a consequence of the Euler-Bernoulli (EB) dynamics of atomic force microscope (AFM) cantilever beams used to make the measurements. Changes in the cantilever mode shape as a function of changes in the boundary conditions determine the sensitivity of cantilevers to forces between the tip and the sample. Conventional PFM and AFM measurements are made with the motion of the cantilever measured at one optical beam detector (OBD) spot location. A single OBD spot location provides a limited picture of the total cantilever motion, and in fact, experimentally observed cantilever amplitude and phase are shown to be strongly dependent on the OBD spot position for many measurements. In this work, the commonly observed frequency dependence of PFM response is explained through experimental measurements and analytic theoretical EB modeling of the PFM response as a function of both frequency and OBD spot location on a periodically poled lithium niobate sample. One notable conclusion is that a common choice of OBD spot location—at or near the tip of the cantilever—is particularly vulnerable to frequency dependent amplitude and phase variations stemming from dynamics of the cantilever sensor rather than from the piezoresponse of the sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AFM-IR and s-SNOM-IR measurements of chemically addressable monolayers on Au nanoparticles

The performance of catalysts depends on their nanoscale properties, and local variations in structure and composition can have a dramatic impact on the catalytic reactivity. Therefore, probing the localized reactivity of catalytic surfaces using high spatial resolution vibrational spectroscopy, such as infrared (IR) nanospectroscopy and tip-enhanced Raman spectroscopy, is essential for mapping their reactivity pattern. Two fundamentally different scanning probe IR nanospectroscopy techniques, namely, scattering-type scanning near-field optical microscopy (sSNOM) and atomic force microscopy-infrared spectroscopy (AFM-IR), provide the capabilities for mapping the reactivity pattern of catalytic surfaces with a spatial resolution of ~20 nm. Herein, we compare these two techniques with regard to their applicability for probing the vibrational signature of reactive molecules on catalytic nanoparticles. For this purpose, we use chemically addressable self-assembled molecules on Au nanoparticles as model systems. We identified significant spectral differences depending on the measurement technique, which originate from the fundamentally different working principles of the applied methods. While AFM-IR spectra provided information from all the molecules that were positioned underneath the tip, the s-SNOM spectra were more orientation-sensitive. Due to its field-enhancement factor, the s-SNOM spectra showed higher vibrational signals for dipoles that were perpendicularly oriented to the surface. The s-SNOM sensitivity to the molecular orientation influenced the amplitude, position, and signal-to-noise ratio of the collected spectra. Ensemble-based IR measurements verified that differences in the localized IR spectra stem from the enhanced sensitivity of s-SNOM measurements to the adsorption geometry of the probed molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructure evolution of Al-doped zinc oxide and Sn-doped indium oxide deposited by radio-frequency magnetron sputtering: A comparison

The microstructure and morphology evolution of Al-doped zinc oxide (AZO) and Sn-doped indium oxide (ITO) thin films on borosilicate glass substrates deposited by radio-frequency magnetron sputtering at room temperature (RT) and 300 °C were investigated by X-ray diffraction and atomic force microscopy (AFM). One-dimensional power spectral density (1DPSD) functions derived from the AFM profiles, which can be used to distinguish different growth mechanisms, were used to compare the microstructure scaling behavior of the thin films. The rms roughness R{sub q} evolves with film thickness as a power law, R{sub q} ∼ d{sub f}{sup β}, and different growth exponents β were found for AZO and ITO films. For AZO films, β of 1.47 and 0.56 are obtained for RT and 300 °C depositions, respectively, which are caused by the high compressive stress in the film at RT and relaxation of the stress at 300 °C. While for ITO films, β{sub 1} = 0.14 and β{sub 2} = 0.64 for RT, and β{sub 1} = 0.89 and β{sub 2} = 0.3 for 300 °C deposition are obtained, respectively, which is related to the strong competition between the surface diffusion and shadowing effect and/or grain growth. Electrical properties of both materials as a function of film thickness were also compared. By the modified Fuchs-Sondheimer model fitting of the electrical transport in both materials, different nucleation states are pointed out for both types of films.

36 MATERIALS SCIENCE↗

Traceable atomic force microscopy of high-quality solvent-free crystals of [6,6]-phenyl-C{sub 61}-butyric acid methyl ester

We report high-resolution, traceable atomic force microscopy measurements of high-quality, solvent-free single crystals of [6,6]-phenyl-C61-butyric acid methyl ester (PCBM). These were grown by drop-casting PCBM solutions onto the spectrosil substrates and by removing the residual solvent in a vacuum. A home-built atomic force microscope featuring a plane mirror differential optical interferometer, fiber-fed from a frequency-stabilized laser (emitting at 632.8 nm), was used to measure the crystals' height. The optical interferometer together with the stabilized laser provides traceability (via the laser wavelength) of the vertical measurements made with the atomic force microscope. We find that the crystals can conform to the surface topography, thanks to their height being significantly smaller compared to their lateral dimensions (namely, heights between about 50 nm and 140 nm, for the crystals analysed, vs. several tens of microns lateral dimensions). The vast majority of the crystals are flat, but an isolated, non-flat crystal provides insights into the growth mechanism and allows identification of “molecular terraces” whose height corresponds to one of the lattice constants of the single PCBM crystal (1.4 nm) as measured with X-ray diffraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field emission properties of single crystal chromium disilicide nanowires

The composition, crystal structure, and field emission properties of high-crystallinity chromium disilicide (CrSi{sub 2}) nanowires synthesized by a vapor deposition method have been studied. High resolution transmission electron microscopy, energy dispersive spectroscopy, and selected area electron diffraction studies confirm the single-crystalline structure and composition of the CrSi{sub 2} nanowires. Field emission measurements show that an emission current density of 0.1 {mu}A/cm{sup 2} was obtained at a turn-on electric field intensity of 2.80 V/{mu}m. The maximum emission current measured was 1.86 mA/cm{sup 2} at 3.6 V/{mu}m. The relation between the emission current density and the electric field obtained follows the Fowler-Nordheim equation, with an enhancement coefficient of 1140. The electrical conductivity of single nanowires was measured by using four-point-probe specialized microdevices at different temperatures, and the calculated values are close to those reported in previous studies for highly conductive single crystal bulk CrSi{sub 2}. The thermal tolerance of the nanowires was studied up to a temperature of 1100 Degree-Sign C. The stability of the field emission current, the I-E values, their thermal tolerance, and high electrical conductivity make CrSi{sub 2} nanowires a promising material for field emission applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Wide range local resistance imaging on fragile materials by conducting probe atomic force microscopy in intermittent contact mode

An imaging technique associating a slowly intermittent contact mode of atomic force microscopy (AFM) with a home-made multi-purpose resistance sensing device is presented. It aims at extending the widespread resistance measurements classically operated in contact mode AFM to broaden their application fields to soft materials (molecular electronics, biology) and fragile or weakly anchored nano-objects, for which nanoscale electrical characterization is highly demanded and often proves to be a challenging task in contact mode. Compared with the state of the art concerning less aggressive solutions for AFM electrical imaging, our technique brings a significantly wider range of resistance measurement (over 10 decades) without any manual switching, which is a major advantage for the characterization of materials with large on-sample resistance variations. After describing the basics of the set-up, we report on preliminary investigations focused on academic samples of self-assembled monolayers with various thicknesses as a demonstrator of the imaging capabilities of our instrument, from qualitative and semi-quantitative viewpoints. Then two application examples are presented, regarding an organic photovoltaic thin film and an array of individual vertical carbon nanotubes. Both attest the relevance of the technique for the control and optimization of technological processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging two-dimensional generalized Wigner crystals

The Wigner crystal has fascinated condensed matter physicists for nearly 90 years. Signatures of two-dimensional (2D) Wigner crystals were first observed in 2D electron gases under high magnetic field, and recently reported in transition metal dichalcogenide moiré superlattices. Direct observation of the 2D Wigner crystal lattice in real space, however, has remained an outstanding challenge. Conventional scanning tunnelling microscopy (STM) has sufficient spatial resolution but induces perturbations that can potentially alter this fragile state. Here we demonstrate real-space imaging of 2D Wigner crystals in WSe 2 /WS 2 moiré heterostructures using a specially designed non-invasive STM spectroscopy technique. This employs a graphene sensing layer held close to the WSe 2 /WS 2 moiré superlattice. Local STM tunnel current into the graphene layer is modulated by the underlying Wigner crystal electron lattice in the WSe 2 /WS 2 heterostructure. Different Wigner crystal lattice configurations at fractional electron fillings of n = 1/3, 1/2 and 2/3, where n is the electron number per site, are directly visualized. The n = 1/3 and n = 2/3 Wigner crystals exhibit triangular and honeycomb lattices, respectively, to minimize nearest-neighbour occupations. The n = 1/2 state spontaneously breaks the original C3 symmetry and forms a stripe phase. Here our study lays a solid foundation for understanding Wigner crystal states in WSe 2 /WS 2 moiré heterostructures and provides an approach that is generally applicable for imaging novel correlated electron lattices in other systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser-driven ultrafast transmission electron microscopy

Recent advances in lasers and electron optics technology have allowed transmission electron microscopes to achieve high spatial and temporal resolution, making them capable of tracking atoms, charges and spin motions down to the attosecond and nanometre scales. This Primer discusses the most common and practical experimental implementation of time-resolved transmission electron microscopy and the stroboscopic mode for evaluating ultrafast reversible dynamics. An in-depth discussion of photo-induced near-field electron microscopy, a technique unique to laser-assisted electron microscopy, is also provided, covering its prospective applications in the study of coherent phenomena in quantum materials. The experimental strategies and limitations in investigating the structural dynamics of materials and nanostructures by imaging, diffraction and spectroscopy are also described in detail, with a direct comparison with more conventional and established techniques. Here, we provide key information for new researchers who intend to use ultrafast transmission electron microscopy to address new challenges in specific materials science, condensed matter and nanophotonics.

Transmission electron microscopy↗

Accuracy of tip-sample interaction measurements using dynamic atomic force microscopy techniques: Dependence on oscillation amplitude, interaction strength, and tip-sample distance

Atomic force microscopy (AFM) is a versatile surface characterization method that can map a sample’s topography with high spatial resolution while simultaneously interrogating its surface chemistry through the site-specific high-resolution quantification of the forces acting between the sample and the probe tip. Thanks to considerable advances in AFM measurement technology, such local measurements of chemical properties have gained much popularity in recent years. To this end, dynamic AFM methodologies are implemented where either the oscillation frequency or the oscillation amplitude and phase of the vibrating cantilever are recorded as a function of tip-sample distance and subsequently converted to reflect tip-sample forces or interaction potentials. Such conversion has, however, been shown to produce non-negligible errors when applying the most commonly used mathematical conversion procedures if oscillation amplitudes are of the order of the decay length of the interaction. Extending on these earlier findings, the computational study presented in this paper reveals that the degree of divergence from actual values may also critically depend on both the overall strength of tip-sample interaction and the distance at which the interaction is obtained. These systematic errors can, however, be effectively eliminated by using oscillation amplitudes that are sufficiently larger than the decay length of the interaction potential.

Electrical properties and parameters↗

Optics of colloidal quantum-confined CdSe nanoscrolls

Nanostructures in the form of 1.2-nm-thick colloidal CdSe nanoplatelets rolled into scrolls are investigated. The morphology of these scrolls is analysed and their basic geometric parameters are determined (diameter 29 nm, longitudinal size 100 – 150 nm) by TEM microscopy. Absorption and photoluminescence spectra of these objects are recorded, and the luminescence decay kinetics is studied. It is shown that the optical properties of CdSe nanoscrolls differ significantly from the properties of CdSe quantum dots and that these nanoscrolls are attractive for nanophotonic devices due to large oscillator strengths of the transition, small widths of excitonic peaks and short luminescence decay times. Nanoscrolls can be used to design hybrid organic–inorganic pure-color LEDs with a high luminescence quantum yield and low operating voltages. (optics and technology of nanostructures)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fingerprints of composite fermion Lambda levels in scanning tunneling microscopy

A composite fermion (CF) is a topological quasiparticle that emerges from a nonperturbative attachment of vortices to electrons in strongly correlated two-dimensional materials. Similar to noninteracting fermions that form Landau levels in a magnetic field, CFs can fill analogous “Lambda” levels, giving rise to the fractional quantum Hall (FQH) effect of electrons. Here, we show that Lambda levels can be directly visualized through the characteristic peak structure in the signal obtained via spectroscopy with scanning tunneling microscopy (STM) on a FQH state. Complementary to transport, which probes the low-energy properties of CFs, we show that high-energy features in STM spectra can be interpreted in terms of Lambda levels. We numerically demonstrate that STM spectra can be accurately modeled using Jain's CF theory. Our results show that STM provides a powerful tool for revealing the anatomy of FQH states and identifying physics beyond the noninteracting CF paradigm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atom probe tomography evaporation behavior of C-axis GaN nanowires: Crystallographic, stoichiometric, and detection efficiency aspects

The field evaporation behavior of c-axis GaN nanowires was explored in two different laser-pulsed atom probe tomography (APT) instruments. Transmission electron microscopy imaging before and after atom probe tomography analysis was used to assist in reconstructing the data and assess the observed evaporation behavior. It was found that the ionic species exhibited preferential locations for evaporation related to the underlying crystal structure of the GaN and that the species which evaporated from these locations was dependent on the pulsed laser energy. Additionally, the overall stoichiometry measured by APT was significantly correlated with the energy of the laser pulses. At the lowest laser energies, the apparent composition was nitrogen-rich, while higher laser energies resulted in measurements of predominantly gallium compositions. The percent of ions detected (detection efficiency) for these specimens was found to be considerably below that shown for other materials, even for laser energies which produced the expected Ga:N ratio. The apparent stoichiometry variation and low detection efficiency appear to be a result of evaporation of Ga ions between laser pulses at the lowest laser energies and evaporation of neutral N{sub 2} species at higher laser energies. All of these behaviors are tied to the formation of nitrogen-nitrogen bonds on the tip surface, which occurred under all analysis conditions. Similar field evaporation behaviors are therefore expected for other materials where the anionic species readily form a strong diatomic bond.

36 MATERIALS SCIENCE↗

Entanglement-assisted electron microscopy based on a flux qubit

A notorious problem in high-resolution biological electron microscopy is radiation damage caused by probe electrons. Hence, acquisition of data with minimal number of electrons is of critical importance. Quantum approaches may represent the only way to improve the resolution in this context, but all proposed schemes to date demand delicate control of the electron beam in highly unconventional electron optics. Here we propose a scheme that involves a flux qubit based on a radio-frequency superconducting quantum interference device, inserted in a transmission electron microscope. The scheme significantly improves the prospect of realizing a quantum-enhanced electron microscope for radiation-sensitive specimens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrodynamic interactions of two nearly touching Brownian spheres in a stiff potential: Effect of fluid inertia

The hydrodynamic interaction of two closely spaced micron-scale spheres undergoing Brownian motion was measured as a function of their separation. Each sphere was attached to the distal end of a different atomic force microscopy cantilever, placing each sphere in a stiff one-dimensional potential (0.08 Nm{sup −1}) with a high frequency of thermal oscillations (resonance at 4 kHz). As a result, the sphere’s inertial and restoring forces were significant when compared to the force due to viscous drag. We explored interparticle gap regions where there was overlap between the two Stokes layers surrounding each sphere. Our experimental measurements are the first of their kind in this parameter regime. The high frequency of oscillation of the spheres means that an analysis of the fluid dynamics would include the effects of fluid inertia, as described by the unsteady Stokes equation. However, we find that, for interparticle separations less than twice the thickness of the wake of the unsteady viscous boundary layer (the Stokes layer), the hydrodynamic interaction between the Brownian particles is well-approximated by analytical expressions that neglect the inertia of the fluid. This is because elevated frictional forces at narrow gaps dominate fluid inertial effects. The significance is that interparticle collisions and concentrated suspensions at this condition can be modeled without the need to incorporate fluid inertia. We suggest a way to predict when fluid inertial effects can be ignored by including the gap-width dependence into the frequency number. We also show that low frequency number analysis can be used to determine the microrheology of mixtures at interfaces.

42 ENGINEERING↗

Characteristics of microdomains and microdomain patterns recorded by electron beam irradiation on Y-cut LiNbO{sub 3} crystals

We present the results of investigations of planar domain patterns (isolated domains and domain gratings) fabricated by irradiation of the nonpolar Y-surface of LiNbO{sub 3} crystals by an electron beam (EB) incident normally onto the surface. The EB recorded domains were investigated using atomic force microscopy, confocal second harmonic generation microscopy, and chemical etching as an auxiliary method. The dependence of the domain characteristics on irradiation conditions (acceleration voltage U, EB current I, and irradiation time t{sub irr}) were determined. The length L{sub d} of both isolated domains and domain gratings along the polar axis Z grows linearly with t{sub irr} (at U, I = const) with no tending to saturation. The plots L{sub d}(t{sub irr}) obtained for U = 10 and 15 kV are practically identical, whereas the values of L{sub d} for U = 5 kV are essentially lower. The domain thickness T{sub d} along the Y-direction, i.e., the depth of the switched layer grows with acceleration voltage U. These results are discussed in terms of space-charge fields formation arising under EB irradiation of insulators. The linearity of L{sub d}(t{sub irr}) is accounted for by the frontal domain growth via the viscous friction law. The experimental dependence of T{sub d} on U supports the suggestion that the domain thickness is determined by the penetration depth R{sub e} of primary electrons, which in turn is governed by U. The difference in L{sub d}(t{sub irr}) plots for different U is accounted for by different electron emission σ. Indirect evidences of a defect structure modification in a thin surface layer with respect to the crystal bulk are obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗