Search NASA⌕ Search

SEARCH · Search NASA

Results for “reporting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Using Natural Language Processing of Free-Text Radiology Reports to Identify Type 1 Modic Endplate Changes

Electronic medical record (EMR) systems provide easy access to radiology reports and offer great potential to support quality improvement efforts and clinical research. Harnessing the full potential of the EMR requires scalable approaches such as natural language processing (NLP) to convert text into variables used for evaluation or analysis. Our goal was to determine the feasibility of using NLP to identify patients with Type 1 Modic endplate changes using clinical reports of magnetic resonance (MR) imaging examinations of the spine. Identifying patients with Type 1 Modic change who may be eligible for clinical trials is important as these findings may be important targets for intervention. Four annotators identified all reports that contained Type 1 Modic change, using N = 458 randomly selected lumbar spine MR reports. We then implemented a rule-based NLP algorithm in Java using regular expressions. The prevalence of Type 1 Modic change in the annotated dataset was 10%. Results were recall (sensitivity) 35/50 = 0.70 (95% confidence interval (C.I.) 0.52–0.82), specificity 404/408 = 0.99 (0.97–1.0), precision (positive predictive value) 35/39 = 0.90 (0.75–0.97), negative predictive value 404/419 = 0.96 (0.94–0.98), and F1-score 0.79 (0.43–1.0). Our evaluation shows the efficacy of rule-based NLP approach for identifying patients with Type 1 Modic change if the emphasis is on identifying only relevant cases with low concern regarding false negatives. As expected, our results show that specificity is higher than recall. This is due to the inherent difficulty of eliciting all possible keywords given the enormous variability of lumbar spine reporting, which decreases recall, while availability of good negation algorithms improves specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Radiology Report Summarization Using an Open-Source Natural Language Processing Pipeline

Diagnostic radiologists are expected to review and assimilate findings from prior studies when constructing their overall assessment of the current study. Radiology information systems facilitate this process by presenting the radiologist with a subset of prior studies that are more likely to be relevant to the current study, usually by comparing anatomic coverage of both the current and prior studies. It is incumbent on the radiologist to review the full text report and/or images from those prior studies, a process that is time-consuming and confers substantial risk of overlooking a relevant prior study or finding. This risk is compounded when patients have dozens or even hundreds of prior imaging studies. Our goal is to assess the feasibility of natural language processing techniques to automatically extract asserted and negated disease entities from free-text radiology reports as a step towards automated report summarization. We compared automatically extracted disease mentions to a gold-standard set of manual annotations for 50 radiology reports from CT abdomen and pelvis examinations. The automated report summarization pipeline found perfect or overlapping partial matches for 86% of the manually annotated disease mentions (sensitivity 0.86, precision 0.66, accuracy 0.59, F1 score 0.74). The performance of the automated pipeline was good, and the overall accuracy was similar to the interobserver agreement between the two manual annotators.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a STAT3 reporter prostate cancer cell line for high throughput screening of STAT3 activators and inhibitors

STAT3 is constitutively activated in several cancers, including prostate cancer, and is therefore, a potential target for cancer therapy. DU-145 prostate cancer cells were stably co-transfected with STAT3 reporter and puromycin resistant plasmids to create a stable STAT3 reporter cell line that can be used for high throughput screening of STAT3 modulators. The applicability of this cell line was tested with two known activators and inhibitors of STAT3. As expected, EGF and IL-6 increased STAT3 reporter activity and enhanced the nuclear localization of phosphorylated STAT3 (pSTAT3); whereas Cucurbitacin I and AG490 decreased STAT3 reporter activity dose and time-dependently and reduced the localization of pSTAT3 in the nuclei of prostate cancer cells. Given the importance of STAT3 in cancer initiation and progression, the development of a stable STAT3 reporter cell line in prostate cancer cells provides a rapid, sensitive, and cost effective method for the screening of potential STAT3 modulators.

60 APPLIED LIFE SCIENCES↗

Tailoring a low-molecular weight protein tyrosine phosphatase into an efficient reporting protein

Fusion reporter methods are important tools for biology and biotechnology. An ideal reporter protein in a fusion system should have little effects on its fusion partner and provide an easy and accurate readout. Therefore, a small monomeric protein with high activity for detection assays often has advantages as a reporter protein. For this purpose, we have tailored the human B-form low-molecular-weight phosphotyrosyl phosphatase (HPTP-B) to increase its general applicability as a potent reporter protein. With the aim to eliminate interference from cysteine residues in the native HPTP-B, combined with a systematic survey of N- and C-terminal truncated variants, a series of cysteine to serine mutations were introduced, which allowed isolation of an engineered soluble protein with suitable biophysical properties. When we deleted both the first six residues and the last two residues, we still obtained a soluble mutant protein with correct folding and similar activity with wild-type protein. This mutant with two cysteine to serine mutations, HPTP-B{sup N{sub {Delta}}6-C{sub {Delta}}2-C90S-C109S}, has good potential as an optimal reporter.

60 APPLIED LIFE SCIENCES↗

A Comprehensive Quality Assurance Program for Personnel and Procedures in Radiation Oncology: Value of Voluntary Error Reporting and Checklists

Purpose: This report describes the value of a voluntary error reporting system and the impact of a series of quality assurance (QA) measures including checklists and timeouts on reported error rates in patients receiving radiation therapy. Methods and Materials: A voluntary error reporting system was instituted with the goal of recording errors, analyzing their clinical impact, and guiding the implementation of targeted QA measures. In response to errors committed in relation to treatment of the wrong patient, wrong treatment site, and wrong dose, a novel initiative involving the use of checklists and timeouts for all staff was implemented. The impact of these and other QA initiatives was analyzed. Results: From 2001 to 2011, a total of 256 errors in 139 patients after 284,810 external radiation treatments (0.09% per treatment) were recorded in our voluntary error database. The incidence of errors related to patient/tumor site, treatment planning/data transfer, and patient setup/treatment delivery was 9%, 40.2%, and 50.8%, respectively. The compliance rate for the checklists and timeouts initiative was 97% (P<.001). These and other QA measures resulted in a significant reduction in many categories of errors. The introduction of checklists and timeouts has been successful in eliminating errors related to wrong patient, wrong site, and wrong dose. Conclusions: A comprehensive QA program that regularly monitors staff compliance together with a robust voluntary error reporting system can reduce or eliminate errors that could result in serious patient injury. We recommend the adoption of these relatively simple QA initiatives including the use of checklists and timeouts for all staff to improve the safety of patients undergoing radiation therapy in the modern era.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient-Reported Voice and Speech Outcomes After Whole-Neck Intensity Modulated Radiation Therapy and Chemotherapy for Oropharyngeal Cancer: Prospective Longitudinal Study

Purpose: To describe voice and speech quality changes and their predictors in patients with locally advanced oropharyngeal cancer treated on prospective clinical studies of organ-preserving chemotherapy–intensity modulated radiation therapy (chemo-IMRT). Methods and Materials: Ninety-one patients with stage III/IV oropharyngeal cancer were treated on 2 consecutive prospective studies of definitive chemoradiation using whole-field IMRT from 2003 to 2011. Patient-reported voice and speech quality were longitudinally assessed from before treatment through 24 months using the Communication Domain of the Head and Neck Quality of Life (HNQOL-C) instrument and the Speech question of the University of Washington Quality of Life (UWQOL-S) instrument, respectively. Factors associated with patient-reported voice quality worsening from baseline and speech impairment were assessed. Results: Voice quality decreased maximally at 1 month, with 68% and 41% of patients reporting worse HNQOL-C and UWQOL-S scores compared with before treatment, and improved thereafter, recovering to baseline by 12-18 months on average. In contrast, observer-rated larynx toxicity was rare (7% at 3 months; 5% at 6 months). Among patients with mean glottic larynx (GL) dose ≤20 Gy, >20-30 Gy, >30-40 Gy, >40-50 Gy, and >50 Gy, 10%, 32%, 25%, 30%, and 63%, respectively, reported worse voice quality at 12 months compared with before treatment (P=.011). Results for speech impairment were similar. Glottic larynx dose, N stage, neck dissection, oral cavity dose, and time since chemo-IMRT were univariately associated with either voice worsening or speech impairment. On multivariate analysis, mean GL dose remained independently predictive for both voice quality worsening (8.1%/Gy) and speech impairment (4.3%/Gy). Conclusions: Voice quality worsening and speech impairment after chemo-IMRT for locally advanced oropharyngeal cancer were frequently reported by patients, underrecognized by clinicians, and independently associated with GL dose. These findings support reducing mean GL dose to as low as reasonably achievable, aiming at ≤20 Gy when the larynx is not a target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of calculated dose distributions reported as dose-to-water and dose-to-medium for intensity-modulated radiotherapy of nasopharyngeal cancer patients

Advanced dose calculation algorithms for radiation therapy treatment planning can report external beam photon dose 2-sided, in terms of dose-to-medium (D{sub m}) and dose-to-water (D{sub w}). The purpose of our study was to determinate the effect of D{sub w} and D{sub m} reporting modes built in Elekta Monaco treatment planning system on intensity-modulated radiotherapy dose distributions for patients with nasopharyngeal cancer. For 13 patients involved in this retrospective study, 2 plans were created: 1 using D{sub w} and another according to D{sub m} reporting mode. Treatment plans were normalized such that 100% planning target volume should be covered by 95% of prescribed dose. Dose-volume constraints were assigned according to international standards. The comparison between dose distributions was performed evaluating quantities important for respective volumes of interest. For target volumes, heterogeneity index and conformity index methodology were used along with the maximum dose concept. Also, for the comparisons over particular organ at risk, maximum dose or mean dose as well as dose-volume concepts were used. For all target volumes and majority of organs at risk, the differences between 2 reporting modes are statistically insignificant, but this is not the case for bony structured organs at risks: mandible and cochlea. It was observed that D{sub w} is higher than D{sub m} with mean difference of 9.91% (p = 0.000009) of the mandible volume covered with 70 Gy. The same trend was observed for left and right cochlea with difference in mean dose of 8.74% (p = 0.037) and 6.87% (p = 0.029), respectively. The comparative analysis of dosimetric parameters in this study shows that the selection of reporting modes in Monaco treatment planning system can produce dose differences up to 15% in high-density volumes such as mandible and cochlea, which might have clinical consequences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of HSPA1A promoter-driven luciferase reporter gene assays in human cells for assessing the oxidative damage induced by silver nanoparticles

The exponential increase in the total number of engineered nanoparticles in consumer products requires novel tools for rapid and cost-effective toxicology screening. In order to assess the oxidative damage induced by nanoparticles, toxicity test systems based on a human HSPA1A promoter-driven luciferase reporter in HepG2, LO2, A549, and HBE cells were established. After treated with heat shock and a group of silver nanoparticles (AgNPs) with different primary particle sizes, the cell viability, oxidative damage, and luciferase activity were determined. The time-dependent Ag{sup +} ions release from AgNPs in cell medium was also evaluated. Our results showed that heat shock produced a strong time-dependent induction of relative luciferase activity in the four luciferase reporter cells. Surprisingly, at 4 h of recovery, the relative luciferase activity was > 98 × the control level in HepG2-luciferase cells. Exposure to different sizes of AgNPs resulted in activation of the HSPA1A promoter in a dose-dependent manner, even at low cytotoxic or non-cytotoxic doses. The smaller (5 nm) AgNPs were more potent in luciferase induction than the larger (50 and 75 nm) AgNPs. These results were generally in accordance with the oxidative damage indicated by malondialdehyde concentration, reactive oxygen species induction and glutathione depletion, and Ag{sup +} ions release in cell medium. Compared with the other three luciferase reporter cells, the luciferase signal in HepG2-luciferase cells is obviously more sensitive and stable. We conclude that the luciferase reporter cells, especially the HepG2-luciferase cells, could provide a valuable tool for rapid screening of the oxidative damage induced by AgNPs. - Highlights: • We established the stable HSPA1A promoter-driven luciferase reporter cells. • Silver nanoparticles induced dose-dependent increases in luciferase activity. • HSPA1A promoter activity is a sensitive and responsive indicator of oxidative stress. • HepG2-luciferase cells can be used to assess the toxicity of silver nanoparticles.

60 APPLIED LIFE SCIENCES↗

Nuclear location of minor capsid protein L2 is required for expression of a reporter plasmid packaged in HPV51 pseudovirions

The deduced amino acid (aa) sequence of L2 of the newly sequenced HPV51 strain, isolated by Matsukura and Sugase (Ma-strain), was markedly different from that of the prototype HPV51 isolated by Nuovo et al. (Nu-strain) (GenBank (M62877)) in two regions: aa 95-99 (region I) and aa 179-186 (region II). The two regions of Ma-strain were homologous to those of the other mucosal HPVs. The aa sequences of the N-terminal and C-terminal regions of Ma-L2 and Nu-L2 were identical and contained the nuclear localizing signal (NLS). When expressed in HEK293 cells, Ma-strain L2 (Ma-L2) was located in the nucleus but Nu-strain L2 (Nu-L2), in the cytoplasm. The chimeric L2s having both Nu-L2 regions I and II were located in the cytoplasm, and those having one of them were located both in the nucleus and cytoplasm, suggesting that Nu-L2 regions I and II inhibit the NLS function. For a better understanding of a role of L2 in infection, pseudovirion (PV) preparations were produced with a reporter, Ma-strain L1, and various L2s (Ma-L2, Nu-L2, or the chimeric L2s). These PV preparations contained structurally similar particles composed of L1 and L2 and the packaged reporter plasmid at a similar level. The reporter expression was not induced in HEK293 cells after inoculation with PVs containing the L2s that are incapable of localizing in the nucleus when expressed alone. Among PVs containing L2s capable of localizing in the nucleus, the reporter expression was induced only by PVs containing Ma-L2 region I. Thus, the results indicate that the expression of the reporter in the HPV51 PV requires the nuclear localizing ability of L2 and another unknown function associated with region I.

60 APPLIED LIFE SCIENCES↗

Recent Advances in Probing Electron Delocalization in Conjugated Molecules by Attached Infrared Reporter Groups for Energy Conversion and Storage

This review article reports an overview of the recent developments in the field of electron delocalization study in organic conjugated molecules by utilizing the vibration frequencies exhibited by the attached functional groups such as nitrile (–C≡N), alkyne (–C≡C–), or carbonyl (–C=O). A brief introduction to electron delocalization, methods for study, and their importance is given first, followed by the application of infrared spectroscopy in organic molecules. Details of molecules with various infrared reporter groups have been explained in respective subsections based on the functional groups. All the reported organic molecules have been structured and presented with the electron delocalization properties studied using an infrared reporter group. Finally, an outlook on this recently promising, exciting, and interesting field of probing electron delocalization using infrared reporter groups is provided.

25 ENERGY STORAGE↗

Inferring the spread of COVID-19: the role of time-varying reporting rate in epidemiological modelling

The role of epidemiological models is crucial for informing public health officials during a public health emergency, such as the COVID-19 pandemic. However, traditional epidemiological models fail to capture the time-varying effects of mitigation strategies and do not account for under-reporting of active cases, thus introducing bias in the estimation of model parameters. To infer more accurate parameter estimates and to reduce the uncertainty of these estimates, we extend the SIR and SEIR epidemiological models with two time-varying parameters that capture the transmission rate and the rate at which active cases are reported to health officials. Using two real data sets of COVID-19 cases, we perform Bayesian inference via our SIR and SEIR models with time-varying transmission and reporting rates and via their standard counterparts with constant rates; our approach provides parameter estimates with more realistic interpretation, and 1-week ahead predictions with reduced uncertainty. Furthermore, we find consistent under-reporting in the number of active cases in the data that we consider, suggesting that the initial phase of the pandemic was more widespread than previously reported.

42 ENGINEERING↗

Tool for Searching USEPA’s TMDL Reports Repository to Analyze TMDL Modeling State of the Practice

We report that total maximum daily load (TMDL) reports archived in the USEPA database can provide useful guidance for the development of new TMDLs and watershed management plans by aiding the selection process for the most appropriate modeling tool. The database contains more than 70,000 individual documents; therefore, a rapid screening tool is needed to elicit information about previous modeling studies that might help guide stakeholders and regulators in dealing with the TMDL application at hand, save time, and lead to a more cost-effective regulatory outcome. The paper introduces a smart web-based software tool for TMDL report selection based on different water management criteria. The tool uses an automated search method based on frequency of common water body impairments and models to categorize and select TMDL reports. Additionally, this tool provides better insight on the relationship between the modeling tools used and the impairments they address. This tool has proven useful in reviewing the state of integrated modeling (IM), applications of remote sensing (RS), application of basic versus mechanistic modeling, margin of safety (MOS) assessment, and the state of practice regarding relationships among impairments, models, and regions where TMDLs for various pollutants are being developed. Despite limitations on direct access to all TMDLs developed and reported to the EPA by the user, the tool can be improved over time to derive a better understanding of the relationships between these impairments, data, and the TMDL development process. Finally, although the MOS is not directly quantified in the current version of the TRS tool, this feature may be incorporated in future updates.

54 ENVIRONMENTAL SCIENCES↗

Trends in the administration of COVID-19 vaccines with other vaccines in the United States reported to V-safe during December 14, 2020—May 19, 2023

Introduction COVID-19 vaccines may be administered with other vaccines during the same healthcare visit. COVID-19 monovalent (Fall 2021) and bivalent (Fall 2022) vaccine recommendations coincided with annual seasonal influenza vaccination. Data describing the frequency of the co-administration of COVID-19 vaccines with other vaccines are limited. Methods We used V-safe, a voluntary smartphone-based U.S. safety surveillance system established by the CDC, to describe trends in the administration of COVID-19 vaccines with other vaccines reported to V-safe during December 14, 2020 – May 19, 2023. Results Of the 21 million COVID-19 vaccinations reported to V-safe, 2.2% (459,817) were administered with at least 1 other vaccine. Co-administration most frequently occurred during the first week of October 2023 (27,092; 44.1%). Most reports of co-administration included influenza vaccine (393,003; 85.5%). Co-administration was most frequently reported for registrants aged 6 months-6 years (4,872; 4.4%). Conclusion Reports of co-administration to V-safe peaked during October 2023, when influenza vaccination most often occurs, possibly reflecting increased opportunities for multiple vaccinations and greater acceptability of the co-administration of COVID-19 vaccine with other vaccines, especially influenza vaccine.

60 APPLIED LIFE SCIENCES↗

Inverse Regression for Extraction of Tumor Site from Cancer Pathology Reports

Pathology reports are the primary source of information for cancer diagnosis of millions of the cancer patients across the United States. Cancer registries label these reports every year. The coded labels incorporate pertinent information such as cancer location, behavior, and histology. This information when combined with clinical information, medical imaging and even genomic information have a great potential to fuel discoveries in cancer research. The coding process is manual and requires many human experts to label the large volume of pathology reports in a timely manner. In this study, we have developed a supervised inverse regression based auto-labeler to automate the task. The experiments were conducted on a set of 942 pathology reports with human expert labels as the ground truth. We observed that the inverse regression based auto-labeler consistently performed better than or comparable to the best performing state-of-the-art method. These results demonstrate the potential of inverse regression for reliable information extraction from the pathology reports.

Dubey, Abhishek↗

Material report in support to RCC-MRX code 2010 stainless steel parts and products

This paper presents the Material Report dedicated to stainless steels parts and products issued by AFCEN (Association Francaise pour les regles de Conception et de Construction des Materiels des Chaudieres Electro-Nucleaires) in support to RCC-MRx 2010 Code. The RCC-MRx Code is the result of the merger of the RCC-MX 2008, developed in the context of the research reactor Jules Horowitz Reactor project, in the RCC-MR 2007, which set up rules applicable to the design of components operating at high temperature and to the Vacuum Vessel of ITER (a presentation of RCC-MRx 2010 Code is the subject of another paper proposed in this Congress; it explains in particular the status of this Code). This Material Report is part of a set of Criteria of RCC-MRx (this set of Criteria is under construction). The Criteria aim at explaining the design and construction rules of the Code. They cover analyses rules as well as part procurement, welding, methods of tests and examination and fabrication rules. The Material Report particularly provides justifications and explanations on requirements and features dealing with parts and products proposed in the Code. The Material Report contains the following information: Introduction of the grade(s): codes and standards and Reference Procurement Specifications covering parts and products, applications and experience gained, - Physical properties, - Mechanical properties used for design calculations (base metal and welds): basic mechanical properties, creep mechanical properties, irradiated mechanical properties, - Fabrication: experience gained, metallurgy, - Welding: weldability, experience gained during welding and repair procedure qualifications, - Non-destructive examination, - In-service behaviour. In the article, examples of data supplied in the Material Report dedicated to stainless steels will be exposed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Off-label use of medical products in radiation therapy: Summary of the Report of AAPM Task Group No. 121

Medical products (devices, drugs, or biologics) contain information in their labeling regarding the manner in which the manufacturer has determined that the products can be used in a safe and effective manner. The Food and Drug Administration (FDA) approves medical products for use for these specific indications which are part of the medical product's labeling. When medical products are used in a manner not specified in the labeling, it is commonly referred to as off-label use. The practice of medicine allows for this off-label use to treat individual patients, but the ethical and legal implications for such unapproved use can be confusing. Although the responsibility and, ultimately, the liability for off-label use often rests with the prescribing physician, medical physicists and others are also responsible for the safe and proper use of the medical products. When these products are used for purposes other than which they were approved, it is important for medical physicists to understand their responsibilities. In the United States, medical products can only be marketed if officially cleared, approved, or licensed by the FDA; they can be used if they are not subject to or specifically exempt from FDA regulations, or if they are being used in research with the appropriate regulatory safeguards. Medical devices are either cleared or approved by FDA's Center for Devices and Radiological Health. Drugs are approved by FDA's Center for Drug Evaluation and Research, and biological products such as vaccines or blood are licensed under a biologics license agreement by FDA's Center for Biologics Evaluation and Research. For the purpose of this report, the process by which the FDA eventually clears, approves, or licenses such products for marketing in the United States will be referred to as approval. This report summarizes the various ways medical products, primarily medical devices, can legally be brought to market in the United States, and includes a discussion of the approval process, along with manufacturers' responsibilities, labeling, marketing and promotion, and off-label use. This is an educational and descriptive report and does not contain prescriptive recommendations. This report addresses the role of the medical physicist in clinical situations involving off-label use. Case studies in radiation therapy are presented. Any mention of commercial products is for identification only; it does not imply recommendations or endorsements of any of the authors or the AAPM. The full report, containing extensive background on off-label use with several appendices, is available on the AAPM website (http://www.aapm.org/pubs/reports/).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-596: P3DVHStats - a Novel, Automatic, Institution Customizable Program to Compute and Report DVH Quantities On Philips Pinnacle TPS

Purpose: To implement a novel, automatic, institutional customizable DVH quantities evaluation and PDF report tool on Philips Pinnacle treatment planning system (TPS) Methods: An add-on program (P3DVHStats) is developed by us to enable automatic DVH quantities evaluation (including both volume and dose based quantities, such as V98, V100, D2), and automatic PDF format report generation, for EMR convenience. The implementation is based on a combination of Philips Pinnacle scripting tool and Java language pre-installed on each Pinnacle Sun Solaris workstation. A single Pinnacle script provide user a convenient access to the program when needed. The activated script will first export DVH data for user selected ROIs from current Pinnacle plan trial; a Java program then provides a simple GUI interface, utilizes the data to compute any user requested DVH quantities, compare with preset institutional DVH planning goals; if accepted by users, the program will also generate a PDF report of the results and export it from Pinnacle to EMR import folder via FTP. Results: The program was tested thoroughly and has been released for clinical use at our institution (Pinnacle Enterprise server with both thin clients and P3PC access), for all dosimetry and physics staff, with excellent feedback. It used to take a few minutes to use MS-Excel worksheet to calculate these DVH quantities for IMRT/VMAT plans, and manually save them as PDF report; with the new program, it literally takes a few mouse clicks in less than 30 seconds to complete the same tasks. Conclusion: A Pinnacle scripting and Java language based program is successfully implemented, customized to our institutional needs. It is shown to dramatically reduce time and effort needed for DVH quantities computing and EMR reporting.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-107: Correlations Between Dosimetric Indices of Pharyngeal Constrictors and Proximal Esophagus with Associated Patient-Reported Outcomes Six Months After Radiation Therapy for Head and Neck Cancer

Purpose: To compare the correlations between different dosimetric indices derived from the pharyngeal constrictor muscles and proximal esophagus with patient-reported difficulty in swallowing 6 months post radiotherapy using a novel patient reported outcome version of CTCAE (PRO-CTCAE). Methods: Forty-three patients with oropharyngeal squamous cell carcinoma were treated on a prospective multi-institutional study. All patients received de-intensified 60 Gy intensity modulated radiotherapy. We investigated correlations of individual patient dosimetric data of the superior (SPC), middle (MPC), inferior (IPC) pharyngeal constrictor muscles, the superior esophagus (SES), and the inferior esophagus (IES) to their self-reported 6 month post-treatment swallowing difficulty responses. Mild (≥ Grade 1) swallowing difficulty responses were used as the clinical endpoint indicating response. The predictive efficacy of Dmean and dose-volume (VD) points were assessed through the area under the Receiver Operating Characteristic curve (ROC) and Odds Ratio (OR). Results: The SES and SPC had more favorable area under the curves (AUC) for the Dmean (0.62 and 0.70) while the Dmean to the IPC, MPC, and IES produced suboptimal AUCs (0.42, 0.48, and 0.52). Additionally, over the range of VD, the V54 and V55 for the SES and SPC demonstrated the highest AUCs: AUC(SES) = 0.76–0.73 and AUC(SPC) = 0.72–0.69, respectively. The IES, IPC, and MPC had worse AUC results over the range of VD. An optimal OR can be found when V54 = 96% for the SPC, where OR = 3.96 (1.07–14.62). Conclusion: The V45 and V55 of the SES and SPC had the highest correlation to the clinical endpoint compared to the commonly used dosimetric index, Dmean for both the esophagus and constrictor muscles. The reported dosimetric data demonstrates that new dosimetric indices may need to be considered in the setting of dose de-escalation and self-reported outcomes.

60 APPLIED LIFE SCIENCES↗