Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

An Efficient Silent Data Corruption Detection Method with Error-Feedback Control and Even Sampling for HPC Applications

The silent data corruption (SDC) problem is attracting more and more attentions because it is expected to have a great impact on exascale HPC applications. SDC faults are hazardous in that they pass unnoticed by hardware and can lead to wrong computation results. In this work, we formulate SDC detection as a runtime one-step-ahead prediction method, leveraging multiple linear prediction methods in order to improve the detection results. The contributions are twofold: (1) we propose an error feedback control model that can reduce the prediction errors for different linear prediction methods, and (2) we propose a spatial-data-based even-sampling method to minimize the detection overheads (including memory and computation cost). We implement our algorithms in the fault tolerance interface, a fault tolerance library with multiple checkpoint levels, such that users can conveniently protect their HPC applications against both SDC errors and fail-stop errors. We evaluate our approach by using large-scale traces from well-known, large-scale HPC applications, as well as by running those HPC applications on a real cluster environment. Experiments show that our error feedback control model can improve detection sensitivity by 34-189% for bit-flip memory errors injected with the bit positions in the range [20,30], without any degradation on detection accuracy. Furthermore, memory size can be reduced by 33% with our spatial-data even-sampling method, with only a slight and graceful degradation in the detection sensitivity.

Di, Sheng↗

Production and distribution of dilute species in semiconducting materials

Technologies are described effective to implement systems and methods of producing a material. The methods comprise receiving a tertiary semiconductor sample with a dilute species. The sample has two ends. The first end of the sample includes a first concentration of the dilute species lower than a second concentration of the dilute species in the second end of the sample. The method further comprises heating the sample in a chamber. The chamber has a first zone and a second zone. The first zone having a first temperature higher than a second temperature in the second zone. The sample is orientated such that the first end is in the first zone and the second end is in the second zone.

36 MATERIALS SCIENCE↗

A streamlined tandem tip-based workflow for sensitive nanoscale phosphoproteomics

Effective phosphoproteome of nanoscale sample analysis remains a daunting task, primarily due to significant sample loss associated with non-specific surface adsorption during enrichment of low stoichiometric phosphopeptide. We develop a tandem tip phosphoproteomics sample preparation method that is capable of sample cleanup and enrichment without additional sample transfer, and its integration with our recently developed SOP (Surfactant-assisted One-Pot sample preparation) and iBASIL (improved Boosting to Amplify Signal with Isobaric Labeling) approaches provides a streamlined workflow enabling sensitive, high-throughput nanoscale phosphoproteome measurements. This approach significantly reduces both sample loss and processing time, allowing the identification of >3000 (>9500) phosphopeptides from 1 (10) µg of cell lysate using the label-free method without a spectral library. It also enables precise quantification of ~600 phosphopeptides from 100 sorted cells (single-cell level input for the enriched phosphopeptides) and ~700 phosphopeptides from human spleen tissue voxels with a spatial resolution of 200 µm (equivalent to ~100 cells) in a high-throughput manner. The new workflow opens avenues for phosphoproteome profiling of mass-limited samples at the low nanogram level.

59 BASIC BIOLOGICAL SCIENCES↗

Spectrofluorometer techniques applicable to sample surfaces

Methods for correcting fluorescence spectra to remove instrumental artifacts are described, including computational and graphical procedures for rapid manual correction by nomographs and similar techniques. Expedient methods for the selection and use of optical filters, the evaluation of filter effectiveness, and the selection of optimum wavelength settings in spectrofluorometry are outlined.

Stoertz, G. E.↗

Microwave assisted centrifuge and related methods

Centrifuge samples may be exposed to microwave energy to heat the samples during centrifugation and to promote separation of the different components or constituents of the samples using a centrifuge device configured for generating microwave energy and directing the microwave energy at a sample located in the centrifuge.

Meikrantz, David H↗

Machine learning technique to identify grains in polycrystalline materials samples

A method of identifying grains in polycrystalline materials, the method including (a) identifying local crystal structure of the polycrystalline material based on neighbor coordination or pattern recognition machine learning, the local crystal structure including grains and grain boundaries, (b) pre-processing the grains and the grain boundaries using image processing techniques, (c) conducting grain identification using unsupervised machine learning; and (d) refining a resolution of the grain boundaries.

Sankaranarayanan, Subramanian↗

RAPID SEPARATION METHOD FOR 237NP AND PU ISOTOPES IN LARGE SOIL SAMPLES

A new rapid method for the determination of {sup 237}Np and Pu isotopes in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for large soil samples. The new soil method utilizes an acid leaching method, iron/titanium hydroxide precipitation, a lanthanum fluoride soil matrix removal step, and a rapid column separation process with TEVA Resin. The large soil matrix is removed easily and rapidly using this two simple precipitations with high chemical recoveries and effective removal of interferences. Vacuum box technology and rapid flow rates are used to reduce analytical time.

54 ENVIRONMENTAL SCIENCES↗

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

Expression and characterization of the integral membrane domain of bacterial histidine kinase SCO3062 for structural studies

Bacterial histidine kinases play an important role in the response to external stimuli. Structural studies of the histidine kinase transmembrane domain are challenging due to difficulties in protein expression and sample preparation. After carrying out expression screening of a series of histidine kinases, we investigated sample preparation methods for obtaining high quality samples of the periplasmic and transmembrane domain (PTD) of the bacterial histidine kinase SCO3062. Various sample conditions were tested for their ability to give homogeneous NMR spectra of the SCO3062 PTD with well-resolved resonances. Circular dichroism and 3D {sup 15}N-edited NOESY spectrum results demonstrate that the SCO3062 PTD is predominantly {alpha}-helical. This method should be applicable to the NMR analysis of other transmembrane proteins.

60 APPLIED LIFE SCIENCES↗

Sealing and External Sterilization of a Sample Container

A method of (1) sealing a sample of material acquired in a possibly b iologically contaminated ("dirty") environment into a hermetic conta iner, (2) sterilizing the outer surface of the container, then (3) d elivering the sealed container to a clean environment has been propos ed. The method now proposed was originally intended to be used to ret urn samples from Mars to Earth, but could also be used on Earth to t ransport material samples acquired in environments that contain biol ogical hazards and/or, in some cases, chemical hazards.

Bar-Cohen, Yoseph↗

Classifier-guided sampling for discrete variable, discontinuous design space exploration: Convergence and computational performance

A classifier-guided sampling (CGS) method is introduced for solving engineering design optimization problems with discrete and/or continuous variables and continuous and/or discontinuous responses. The method merges concepts from metamodel-guided sampling and population-based optimization algorithms. The CGS method uses a Bayesian network classifier for predicting the performance of new designs based on a set of known observations or training points. Unlike most metamodeling techniques, however, the classifier assigns a categorical class label to a new design, rather than predicting the resulting response in continuous space, and thereby accommodates nondifferentiable and discontinuous functions of discrete or categorical variables. The CGS method uses these classifiers to guide a population-based sampling process towards combinations of discrete and/or continuous variable values with a high probability of yielding preferred performance. Accordingly, the CGS method is appropriate for discrete/discontinuous design problems that are ill-suited for conventional metamodeling techniques and too computationally expensive to be solved by population-based algorithms alone. In addition, the rates of convergence and computational properties of the CGS method are investigated when applied to a set of discrete variable optimization problems. Results show that the CGS method significantly improves the rate of convergence towards known global optima, on average, when compared to genetic algorithms.

42 ENGINEERING↗

Effect of annealing temperature on structure and electrical properties of topological insulator Bi{sub 2}Te{sub 3}

Bi{sub 2}Te{sub 3} samples were prepared by precipitation method. The samples were annealed in evacuated quartz tubes and were treated at different temperature for different duration of time. Effects of annealing temperature and time on the structure of Bi{sub 2}Te{sub 3} were studied in detail. The Bi{sub 2}Te{sub 3} samples annealed at temperature 300°C and 450°C for 48Hrs, 72Hrs and 96Hrs were selected for the present study. The structure of Bi{sub 2}Te{sub 3} and related phases were investigated by the X-ray powder diffraction technique. Morphology and chemical compositions of the samples were investigated by scanning electron microscope and energy dispersive X-ray spectroscopy respectively. All the samples were indexed in rhombohedral crystal structure, with a space group R-3m. The structure consists of repeated quintuple layers of atoms, Te2-Bi-Te1-Bi-Te2 stacking along the z-axis of the unit cell. Electrical properties of the sample annealed at 300°C for 96Hrs was evaluated by measurements of the electrical resistivity and magnetoresistance. The magnetoresistance data at low temperature (1.5 to 50 K) were analyzed to investigate weak antilocalization (WAL) effect. MR data followed the Hikami–Larkin–Nagaoka (HLN) equation with a fit parameter α close to −1 as expected for topological surface states at 1.5 K, but for other temperatures the small oscillations were observed which may be due to the phenomena like Shubnikov-de Hass effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dielectric measurement using an open ended coaxial line with an extended center conductor

Permittivity may be determined by measuring the complex reflection coefficient of an open-ended coaxial line placed in contact with a test sample. This method works best for liquid samples. For the measurement of non-liquid materials problems can arise. A perfect preparation is needed to provide a good contact between the tip and the dielectric medium. At times, the dimension of the sensor cannot be freely chosen, as is the case for the measurement of the dielectric constant of the xylem layer of a living tree. The influence of the installation of the sensor on a tree's water status must be minimized by using a small sensor. In such cases the capacitance cannot be optimized. By extending the center conductor of the open-ended coaxial line, some of these problems can be avoided. This provides an additional tool to tune the capacitance of the sensor by adjusting the length of the extension. Therefore the measurement accuracy can be optimized. The sensor also becomes sensitive to a larger volume. A comparative study of a flush and extended tipped probes shows that the ability to measure the dielectric constant of trees has been notably increased due to the extension of the center conductor.

Wegmueller, Urs↗

On sampling fractions and electron shower shapes

We study the usage of various definitions of sampling fractions in understanding electron shower shapes in a sampling multilayer electromagnetic calorimeter. We show that the sampling fractions obtained by the conventional definition (I) of (average observed energy in layer)/(average deposited energy in layer) will not give the best energy resolution for the calorimeter. The reason for this is shown to be the presence of layer by layer correlations in an electromagnetic shower. The best resolution is obtained by minimizing the deviation from the total input energy using a least squares algorithm. The 'sampling fractions' obtained by this method (II) are shown to give the best resolution for overall energy. We further show that the method (II) sampling fractions are obtained by summing the columns of a non-local {lambda} tensor that incorporates the correlations. We establish that the sampling fractions (II) cannot be used to predict the layer by layer energies and that one needs to employ the full {lambda} tensor for this purpose. This effect is again a result of the correlations.

43 PARTICLE ACCELERATORS↗

Rapid sampling of stochastic displacements in Brownian dynamics simulations

Here, we present a new method for sampling stochastic displacements in Brownian Dynamics (BD) simulations of colloidal scale particles. The method relies on a new formulation for Ewald summation of the Rotne-Prager-Yamakawa (RPY) tensor, which guarantees that the real-space and wave-space contributions to the tensor are independently symmetric and positive-definite for all possible particle configurations. Brownian displacements are drawn from a superposition of two independent samples: a wave-space (far-field or long-ranged) contribution, computed using techniques from fluctuating hydrodynamics and non-uniform fast Fourier transforms; and a real-space (near-field or short-ranged) correction, computed using a Krylov subspace method. The combined computational complexity of drawing these two independent samples scales linearly with the number of particles. The proposed method circumvents the super-linear scaling exhibited by all known iterative sampling methods applied directly to the RPY tensor that results from the power law growth of the condition number of tensor with the number of particles. For geometrically dense microstructures (fractal dimension equal three), the performance is independent of volume fraction, while for tenuous microstructures (fractal dimension less than three), such as gels and polymer solutions, the performance improves with decreasing volume fraction. This is in stark contrast with other related linear-scaling methods such as the force coupling method and the fluctuating immersed boundary method, for which performance degrades with decreasing volume fraction. Calculations for hard sphere dispersions and colloidal gels are illustrated and used to explore the role of microstructure on performance of the algorithm. In practice, the logarithmic part of the predicted scaling is not observed and the algorithm scales linearly for up to 4×10 6 particles, obtaining speed ups of over an order of magnitude over existing iterative methods, and making the cost of computing Brownian displacements comparable to the cost of computing deterministic displacements in BD simulations. Finally, a high-performance implementation employing non-uniform fast Fourier transforms implemented on graphics processing units and integrated with the software package HOOMD-blue is used for benchmarking.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atom Probe Tomography for Catalysis Applications: A Review

Atom probe tomography is a well-established analytical instrument for imaging the 3D structure and composition of materials with high mass resolution, sub-nanometer spatial resolution and ppm elemental sensitivity. Thanks to recent hardware developments in Atom Probe Tomography (APT), combined with progress on site-specific focused ion beam (FIB)-based sample preparation methods and improved data treatment software, complex materials can now be routinely investigated. From model samples to complex, usable porous structures, there is currently a growing interest in the analysis of catalytic materials. APT is able to probe the end state of atomic-scale processes, providing information needed to improve the synthesis of catalysts and to unravel structure/composition/reactivity relationships. This review focuses on the study of catalytic materials with increasing complexity (tip-sample, unsupported and supported nanoparticles, powders, self-supported catalysts and zeolites), as well as sample preparation methods developed to obtain suitable specimens for APT experiments.

36 MATERIALS SCIENCE↗

CORRLA-RS

The CORRLA-RS package provides a suite of statistical methods for sampling multidimensional distributions and to conduct sensitivity and correlation analysis of large scale data in the Rust programming language. The software provides a unique solution to multidimensional constrained sampling problems utilizing a combination of parallelized Markov Chain Monte Carlo methods and traditional rejection sampling. The sensitivity and correlation analysis methods are backed by a high performance randomized singular value decomposition implementation which enables datasets larger than the random access memory (RAM) size to be analyzed. Additionally, CORRLA-RS implements the active subspace identification method using a KD-Tree and the randomized singular value decomposition acting in concert.

Gurecky, William [Oak Ridge National Laboratory (O↗

Application of parametric and non-parametric statistics to sounding rocket dispersion including large sample and small sample theory

Analytical methods for obtaining large and small samples to be used in sounding rocket dispersion statistics are described. When the distribution of the parent population is assumed known, a method is called parametric. When no assumption is made about the parent population, the method is called nonparametric. Parametric and nonparametric methods are given for both large and small samples. The assumed distribution for the parametric case will be normal and it is shown that sample nonparametric theory is easier to apply in many cases, giving essentially the same results as parametric theory. The method is applied to the dispersion of NASA sounding rockets from 1959 to 1974.

James F. McGarvey↗