Search NASA⌕ Search

SEARCH · Search NASA

Results for “scoring system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

SU-E-T-669: Radiosurgery Failure for Trigeminal Neuralgia: A Study of Radiographic Spatial Fidelity

Purpose: Management of Trigeminal Neuralgia with radiosurgery is well established, but often met with limited success. Recent advancements in imaging afford improvements in target localization for radiosurgery. Methods: A Trigeminal Neuralgia radiosurgery specific protocol was established for MR enhancement of the trigeminal nerve using a CISS scan with slice spacing of 0.7mm. Computed Tomography simulation was performed using axial slices on a 40 slice CT with slice spacing of 0.6mm. These datasets were registered using a mutual information algorithm and localized in a stereotactic coordinate system. Image registration between the MR and CT was evaluated for each patient by a Medical Physicist to ensure accuracy. The dorsal root entry zone target was defined on the CISS MR by a Neurosurgeon and dose calculations performed on the localized CT. Treatment plans were reviewed and approved by a Radiation Oncologist and Neurosurgeon. Image guided radiosurgery was delivered using positioning tolerance of 0.5mm and 1°. Eight patients with Trigeminal Neuralgia were treated with this protocol. Results: Seven patients reported a favorable response to treatment with average Barrow Neurological Index pain score of four before treatment and one following treatment. Only one patient had a BNI>1 following treatment and review of the treatment plan revealed that the CISS MR was registered to the CT via a low resolution (5mm slice spacing) T2 MR. All other patients had CISS MR registered directly with the localized CT. This patient was retreated 6 months later using direct registration between CISS MR and localized CT and subsequently responded to treatment with a BNI of one. Conclusion: Frameless radiosurgery offers an effective solution to Trigeminal Neuralgia management provided appropriate technology and imaging protocols (utilizing submillimeter imaging) are established and maintained.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dietary antioxidant and anti-inflammatory intake modifies the effect of cadmium exposure on markers of systemic inflammation and oxidative stress

Chronic cadmium exposure may cause disease through induction of systemic oxidative stress and inflammation. Factors that mitigate cadmium toxicity and could serve as interventions in exposed populations have not been well characterized. We used data from the 2003–2010 National Health and Nutrition Examination Survey to quantify diet's role in modifying associations between cadmium exposure and oxidative stress and inflammation. We created a composite antioxidant and anti-inflammatory diet score (ADS) by ranking participants by quintile of intake across a panel of 19 nutrients. We identified associations and effect modification between ADS, urinary cadmium, and markers of oxidative stress and inflammation by multiple linear regression. An interquartile range increase in urinary cadmium was associated with a 47.5%, 8.8%, and 3.7% increase in C-reactive protein (CRP), gamma glutamyl transferase (GGT), and alkaline phosphatase (ALP), respectively. An interquartile range increase in ADS was associated with an 7.4%, 3.3%, 5.2%, and 2.5% decrease in CRP, GGT, ALP, and total white blood cell count respectively, and a 3.0% increase in serum bilirubin. ADS significantly attenuated the association between cadmium exposure, CRP and ALP. Dietary interventions may provide a route to reduce the impact of cadmium toxicity on the population level. - Highlights: • Cadmium may cause chronic disease through oxidative stress or inflammation. • We developed a score to quantify dietary antioxidant and anti-inflammatory intake. • Cadmium was associated with markers of oxidative stress and inflammation. • Antioxidant and anti-inflammatory intake mitigated the effects of cadmium exposure. • Dietary interventions may be effective against chronic cadmium toxicity.

54 ENVIRONMENTAL SCIENCES↗

Phase II Study of Preoperative Helical Tomotherapy With a Simultaneous Integrated Boost for Rectal Cancer

Purpose: The addition of concomitant chemotherapy to preoperative radiotherapy is considered the standard of care for patients with cT3-4 rectal cancer. The combined treatment modality increases the complete response rate and local control (LC), but has no impact on survival or the incidence of distant metastases. In addition, it is associated with considerable toxicity. As an alternative strategy, we explored prospectively, preoperative helical tomotherapy with a simultaneous integrated boost (SIB). Methods and Materials: A total of 108 patients were treated with intensity-modulated and image-guided radiotherapy using the Tomotherapy Hi-Art II system. A dose of 46 Gy, in daily fractions of 2 Gy, was delivered to the mesorectum and draining lymph nodes, without concomitant chemotherapy. Patients with an anticipated circumferential resection margin (CRM) of less than 2 mm, based on magnetic resonance imaging, received a SIB to the tumor up to a total dose of 55.2 Gy. Acute and late side effects were scored using the National Cancer Institute Common Terminology Criteria for Adverse Events version 3.0. Results: A total of 102 patients presented with cT3-4 tumors; 57 patients entered the boost group and 51 the no-boost group. One patient in the no-boost group developed a radio-hypersensitivity reaction, resulting in a complete tumor remission, a Grade 3 acute and Grade 5 late enteritis. No other Grade {>=}3 acute toxicities occurred. With a median follow-up of 32 months, Grade {>=}3 late gastrointestinal and urinary toxicity were observed in 6% and 4% of the patients, respectively. The actuarial 2-year LC, progression-free survival and overall survival were 98%, 79%, and 93%. Conclusions: Preoperative helical tomotherapy displays a favorable acute toxicity profile in patients with cT3-4 rectal cancer. A SIB can be safely administered in patients with a narrow CRM and resulted in a promising LC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

JBlulce Data Acquisition Software for Macromolecular Crystallography

JBlulce (Java Beam Line Universal Integrated Configuration Environment is a data acquisition software for macromolecular crystallography conforming user interface of the SSRL Blulce that has become a de-factor standard in the field. Besides this interface conformity, JBlulce is a unique system in terms of architecture, spec, capability and software implementation. It features only two software layers, the JBlulce clients and the EPICS servers, as compared to three layers present in Blulce and most of similar systems. This layers reduction provides a faster communication with hardware and an easier access to advanced hardware capabilities like on-the-fly scanning. Then JBlulce clients are designed to operate in parallel with the other beamline controls which streamlines the tasks performed by staff such as beamline preparation, maintenance, auditing and user assistance. Another distinction is the deployment of multiple plugins that can be written in any programming language thus involving more staff into the development. further on, JBlulce makes use of unified motion controls allowing for easy scanning and optimizing of any beamline component. Finally, the graphic interface is implemented in Java making full use of rich Java libraries and Jave IDE for debugging. to compare, Blulce user interface is implemented with aging Tcl/tk language providing very restricted capabilities. JBlulce makes full use of the industrial power and wide drivers selection of EPICS in controlling hardware; all hardware communication is routed via multiple EPICS servers residing on local area network. JBlulce also includes several EPICS State Notation servers aimed at making hardware communication more robust. Besides using EPICS for controlling hardware, JBlulce extensively uses EPICS databases for efficient communications between multiple instances of JBlulce clients and JBlulce plugins that can run in parallel on different computers. All of the above makes JBlulce one of the biggest and most sophisticated EPICS client projects to date. JBlulce configuration is stored in my SQL database which provides flexibility in tuning the system. The database is also accessible by the plugins. From the users perspective JBlulce provides all standard features of data acquisition software for macromolecular crystallography plus such unique capabilities as one click beamline energy change that may involve switching undulator harmonics, mirrors lanes and beam realignment, automated diffraction rtastering for finding small crystals and sweet spots on poorly diffracting crystals with automated scoring of raster cells by the number of reflections; data collection along a vector; automated on-the-fly fluorescent tastering, a faster and lower-irradiation compliment to the diffraction raster; fully automated fluorescence measurements for MAD that include signal optimization, fast on the fly energy scanning and automated adapting of scan range to chemical shifts; fly-scan minibeam realignment; automated loop and crystal centering, controls for sample automounter, automated screening, data collection auditing, remote access and a lot more.

Stepanov, Sergey↗

Risk estimation of distant metastasis in node-negative, estrogen receptor-positive breast cancer patients using an RT-PCR based prognostic expression signature

Background: Given the large number of genes purported to be prognostic for breast cancer, it would be optimal if the genes identified are not confounded by the continuously changing systemic therapies. The aim of this study was to discover and validate a breast cancer prognostic expression signature for distant metastasis in untreated, early stage, lymph node-negative (N-) estrogen receptor-positive (ER+) patients with extensive follow-up times. Methods: 197 genes previously associated with metastasis and ER status were profiled from 142 untreated breast cancer subjects. A "metastasis score" (MS) representing fourteen differentially expressed genes was developed and evaluated for its association with distant-metastasis-free survival (DMFS). Categorical risk classification was established from the continuous MS and further evaluated on an independent set of 279 untreated subjects. A third set of 45 subjects was tested to determine the prognostic performance of the MS in tamoxifen-treated women. Results: A 14-gene signature was found to be significantly associated (p < 0.05) with distant metastasis in a training set and subsequently in an independent validation set. In the validation set, the hazard ratios (HR) of the high risk compared to low risk groups were 4.02 (95% CI 1.91–8.44) for the endpoint of DMFS and 1.97 (95% CI 1.28 to 3.04) for overall survival after adjustment for age, tumor size and grade. The low and high MS risk groups had 10-year estimates (95% CI) of 96% (90–99%) and 72% (64–78%) respectively, for DMFS and 91% (84–95%) and 68% (61–75%), respectively for overall survival. Performance characteristics of the signature in the two sets were similar. Ki-67 labeling index (LI) was predictive for recurrent disease in the training set, but lost significance after adjustment for the expression signature. In a study of tamoxifen-treated patients, the HR for DMFS in high compared to low risk groups was 3.61 (95% CI 0.86–15.14). Conclusion: The 14-gene signature is significantly associated with risk of distant metastasis. The signature has a predominance of proliferation genes which have prognostic significance above that of Ki-67 LI and may aid in prioritizing future mechanistic studies and therapeutic interventions.

59 BASIC BIOLOGICAL SCIENCES↗

A Systematic Evaluation of Traditional and Non-Traditional Data Streams for Integrated Global Biosurveillance (Final Report)

Living in a closely connected and highly mobile world presents many new mechanisms for rapid disease spread and in recent years, global disease surveillance has become a high priority. In addition, much like the contribution of non-traditional medicine to curing diseases, non-traditional data streams are being considered of value in disease surveillance. Los Alamos National Laboratory (LANL) was tasked by the Defense Threat Reduction Agency (DTRA)-Joint Science and Technology Office (JSTO) to determine the relevance of data streams for an integrated global biosurveillance system through the use of defined metrics and methodologies. The long-term, broad objective of this project was to provide information and analysis that can be leveraged from existing and developing national and international disease surveillance systems and methodologies, to create a global disease monitoring system, ultimately providing decision makers with timely information to prepare for and mitigate the spread of disease. Specifically, this project evaluated data streams that are currently being used in surveillance systems and data streams that had the potential for being used in surveillance to enable early disease detection. LANL’s focus was on infectious disease surveillance and the term “biosurveillance” will be used to refer to this scope hereafter. Data stream evaluation was conducted using two different methods: Multi criteria decision analysis (MCDA) using a tool called Logical Decisions ® that assigns utility scores to data streams based on weighted metrics and assigned values specific to data stream categories; and a Surveillance Window concept developed at LANL that assigns a window or windows of time specific to a disease within which information coming from various data streams can be determined to have utility. A cross method analysis was performed between the surveillance window based evaluation and the MCDA-based evaluation to identify data stream categories that showed high utility for both methods. In addition, algorithms that can integrate useful data streams to facilitate early disease detection were also examined. This project provided an understanding of data streams relevant to early warning, early detection and monitoring of disease outbreaks. The report describes the results of LANL’s evaluation of 16 data stream categories using the two methods, and recommendations for next steps. The project evolved significantly over its course, and significant improvements in our approaches were made compared to the initial proposed processes. A key outcome of this effort was that LANL was able to bring together several diverse entities involved in disease surveillance and lay the foundation for new collaborations that straddled military and civilian health surveillance. The robust evaluation framework developed by LANL has generated significant interest and there is interest in adopting this framework for various applications both within disease surveillance as well as other public health initiatives. Finally, LANL developed the Biosurveillance Resource Directory (BRD), a relational database that underwent pilot testing by members of the human, plant and animal disease surveillance community. The BRD is intended to be a global resource to facilitate rapid information access.

60 APPLIED LIFE SCIENCES↗

Upward appraisal as a means for improving supervisory performance and promoting process improvement, with long-term implications for organizational change

This study represents the implementation phase of an organizational development project which was initiated last year in the Management Support Division (MSD) at Langley Research Center to diagnose organizational functioning. As a result of MSD survey data from last year's effort, a Quality Action Team was created to address the responses compiled from the MSD Organizational Assessment Questionnaire and Follow-Up Questionnaire. The team was officially named the MSD Employee Relations Improvement Team (MERIT). MERIT's goal was to analyze major concerns generated by the questionnaires and to present feasible solutions to management which would improve supervisory performance, promote process improvement; and ultimately, lead to a better organization. The team met weekly and was very disciplined in following guidelines needed to ensure a fully functioning team. Several TQM tools were used during the team process, including brainstorming and the cause and effect diagram. One of the products produced by MERIT was a 'report card', more formally known as an upward appraisal system, to evaluate supervisory performance in the division office, its three branches, and in teams. Major areas of emphasis on the 47 item report card were those identified by employees through the previously administered questionnaires as needing to be improved; specifically, training, recognition, teamwork, supervision and leadership, and communication. MERIT created an enlarged and modified version of the report card which enabled scores for each individual supervisor to be recorded on a separate form, along with summary results and employee comments. Report card results have been compiled and fed back to the Division Chief and Assistant Division Chief. These individuals will in turn, feed the results back to the remaining supervisors and the team leaders. Although results differ among supervisors, some similarities exist. Communication generally appears to be adequate, which represents an improvement over last year. In contrast, recognition and teamwork are the two major areas where improvement in supervisory performance seems to be most needed. The initial report card results will serve as a baseline against which future performance ratings will be compared. Once supervisors have been presented with their data and given an opportunity to analyze and discus the results, they will be assisted in developing an action plan for improving their performance and work processes. They will be provided with ongoing support from management in following through with the action plan.

Siegfeldt, Denise V.↗

Principal Component-Based Radiative Transfer Model (PCRTM) for Hyperspectral Sensors: Theoretical Concept - Part I

Modern infrared satellite sensors such as Atmospheric Infrared Sounder (AIRS), Cosmic Ray Isotope Spectrometer (CrIS), Thermal Emission Spectrometer (TES), Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) and Infrared Atmospheric Sounding Interferometer (IASI) are capable of providing high spatial and spectral resolution infrared spectra. To fully exploit the vast amount of spectral information from these instruments, super fast radiative transfer models are needed. This paper presents a novel radiative transfer model based on principal component analysis. Instead of predicting channel radiance or transmittance spectra directly, the Principal Component-based Radiative Transfer Model (PCRTM) predicts the Principal Component (PC) scores of these quantities. This prediction ability leads to significant savings in computational time. The parameterization of the PCRTM model is derived from properties of PC scores and instrument line shape functions. The PCRTM is very accurate and flexible. Due to its high speed and compressed spectral information format, it has great potential for super fast one-dimensional physical retrievals and for Numerical Weather Prediction (NWP) large volume radiance data assimilation applications. The model has been successfully developed for the National Polar-orbiting Operational Environmental Satellite System Airborne Sounder Testbed - Interferometer (NAST-I) and AIRS instruments. The PCRTM model performs monochromatic radiative transfer calculations and is able to include multiple scattering calculations to account for clouds and aerosols.

Liu, Xu↗

Surrogate-driven Variance-based Sensitivity Analysis of Thermal Storage Tanks in Integrated Energy Systems

Sensitivity analysis and uncertainty quantification are essential steps for enhancing the accuracy of computational models by identifying and mitigating uncertainties. This study focuses on these steps for the Thermal Energy Delivery System at Idaho National Laboratory, specifically targeting the thermocline tank. Using a Modelica/Dymola simulation model, the study perturbed various design parameters and boundary conditions, including shape factor, porosity, outlet temperature, inlet mass flow rate, and system pressure, to predict and quantify uncertainty in the tank’s ax- ial temperature. A dataset of over 1,000 simulations was generated, and surrogate models were developed using the pyMAISE (Michigan Artificial Intelligence Standard Environment) library, which is an Automatic Machine Learning library for nuclear engineering applications. The optimal model, a feedforward neural network with two hidden layers, achieved an R2 score above 0.99 and a mean absolute error below 1 Kelvin. Sensitivity analyses using Sobol indices and Fourier amplitude sensitivity testing methods on this surrogate model revealed that the inlet mass flow rate at initial timestamps and porosity significantly impacts predicted temperatures across all sensors and time steps.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A comparative analysis of green building rating systems in China and the United States

Several studies have compared green building rating systems (GBRSs) in China and the United States, Nonetheless, few studies included in-depth analysis on specific rating tools with project specific data validating green building technologies and actual performance. This study conducted a comprehensive data-driven comparison of the GBRSs of China and the United States. The goal was to understand the current status and further improve China's GBRS and promote green building technologies. The study first conducted thorough comparisons of GBRSs in China and the U.S. by selecting a series of distinct rating tools. Then, it analyzed each tool's development objectives, contents, and rating score settings. Further, the comparison concludes the future development needs for China's GBRS. In addition to standard comparison, green building technologies applied in certified projects were also summarized. The results demonstrated that GBRSs in both China and the U.S. reflect well the technical paths to achieve green building sustainable development. By analyzing certified projects, it was also found that the incremental costs of green building technologies were controllable. Finally, based on the comparison and case analysis, the study provide a set of policy recommendations to further improve China's green building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Patient-Specific Monte Carlo Dose Calculations for High-Dose-Rate Endorectal Brachytherapy With Shielded Intracavitary Applicator

Purpose: An integrated software platform was developed to perform a patient-specific dosimetric study on high-dose-rate {sup 192}Ir endorectal brachytherapy. Monte Carlo techniques were used to examine the perturbation effects of an eight-channel intracavitary applicator with shielding and a liquid-inflatable balloon. Such effects are ignored in conventional treatment planning systems that assume water-equivalent geometries. Methods and Materials: A total of 40 Task Group 43-based rectal patient plans were calculated using the PTRAN{sub C}T Monte Carlo photon transport code. The silicone applicator, tungsten or lead shielding, contrast solution-filled balloon, and patient anatomy were included in the simulations. The dose to water and dose to medium were scored separately. The effects of heterogeneities and uncertainties in source positioning were examined. A superposition calculation method using pregenerated Monte Carlo dose distributions about the shielded applicator in water was developed and validated for efficient treatment planning purposes. Results: On average, metal shielding decreases the mean dose to the contralateral normal tissues by 24% and reduces the target volume covered by the prescribed dose from 97% to 94%. Tissue heterogeneities contribute to dose differences of <1% relative to the prescribed dose. The differences in the dose volume indices between dose to water and dose to medium-based calculations were <1% for soft tissues, <2% for bone marrow, and >20% for cortical bone. A longitudinal shift of {+-}2.5 mm and a rotational shift of {+-}15{sup o} in applicator insertion reduced the target volume receiving the prescribed dose by {<=}4%. Conclusion: The shielded applicator improved dose conformity and normal tissue sparing; however, Task Group 43-based treatment planning might compromise target coverage by not accounting for shielding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Reconfigurable Computing Technology to Multi-KiloHertz Micro-Laser Altimeter (MMLA) Data Processing

The Multi-KiloHertz Micro-Laser Altimeter (MMLA) is an aircraft based instrument developed by NASA Goddard Space Flight Center with several potential spaceflight applications. This presentation describes how reconfigurable computing technology was employed to perform MMLA signal extraction in real-time under realistic operating constraints. The MMLA is a "single-photon-counting" airborne laser altimeter that is used to measure land surface features such as topography and vegetation canopy height. This instrument has to date flown a number of times aboard the NASA P3 aircraft acquiring data at a number of sites in the Mid-Atlantic region. This instrument pulses a relatively low-powered laser at a very high rate (10 kHz) and then measures the time-of-flight of discrete returns from the target surface. The instrument then bins these measurements into a two-dimensional array (vertical height vs. horizontal ground track) and selects the most likely signal path through the array. Return data that does not correspond to the selected signal path are classified as noise returns and are then discarded. The MMLA signal extraction algorithm is very compute intensive in that a score must be computed for every possible path through the two dimensional array in order to select the most likely signal path. Given a typical array size with 50 x 6, up to 33 arrays must be processed per second. And for each of these arrays, roughly 12,000 individual paths must be scored. Furthermore, the number of paths increases exponentially with the horizontal size of the array, and linearly with the vertical size. Yet, increasing the horizontal and vertical sizes of the array offer science advantages such as improved range, resolution, and noise rejection. Due to the volume of return data and the compute intensive signal extraction algorithm, the existing PC-based MMLA data system has been unable to perform signal extraction in real-time unless the array is limited in size to one column, This limits the ability of the MMLA to operate in environments with sparse signal returns and a high number of noise return. However, under an IR&D project, an FPGA-based, reconfigurable computing data system has been developed that has been demonstrated to perform real-time signal extraction under realistic operating constraints. This reconfigurable data system is based on the commercially available Firebird Board from Annapolis Microsystems. This PCI board consists of a Xilinx Virtex 2000E FPGA along with 36 MB of SRAM arranged in five separately addressable banks. This board is housed in a rackmount PC with dual 850MHz Pentium processors running the Windows 2000 operating system. This data system performs all signal extraction in hardware on the Firebird, but also runs the existing "software based" signal extraction in tandem for comparison purposes. Using a relatively small amount of the Virtex XCV2000E resources, the reconfigurable data system has demonstrated to improve performance improvement over the existing software based data system by an order of magnitude. Performance could be further improved by employing parallelism. Ground testing and a preliminary engineering test flight aboard the NASA P3 has been performed, during which the reconfigurable data system has been demonstrated to match the results of the existing data system.

Powell, Wesley↗

Human-System Integration Scorecard Update to VB.Net

The purpose of this project was to create Human-System Integration (HSI) scorecard software, which could be utilized to validate that human factors have been considered early in hardware/system specifications and design. The HSI scorecard is partially based upon the revised Human Rating Requirements (HRR) intended for NASA's Constellation program. This software scorecard will allow for quick appraisal of HSI factors, by using visual aids to highlight low and rapidly changing scores. This project consisted of creating a user-friendly Visual Basic program that could be easily distributed and updated, to and by fellow colleagues. Updating the Microsoft Word version of the HSI scorecard to a computer application will allow for the addition of useful features, improved easy of use, and decreased completion time for user. One significant addition is the ability to create Microsoft Excel graphs automatically from scorecard data, to allow for clear presentation of problematic areas. The purpose of this paper is to describe the rational and benefits of creating the HSI scorecard software, the problems and goals of project, and future work that could be done.

Sanders, Blaze D.↗

Dose-Dependent Effects of Radiation Therapy on Cerebral Blood Flow, Metabolism, and Neurocognitive Dysfunction

Purpose: A prospective study was performed to formally relate dose-dependent radiologically defined changes in normal brain induced by radiotherapy (RT) to neurocognitive dysfunction in subjects with primary brain tumors. Methods and Materials: Adult patients receiving three-dimensional RT for central nervous system (CNS) tumors were enrolled. Positron emission tomography (PET) scanning and neuropsychological testing were performed before RT and 3 weeks and 6 months after treatment. Analyses were performed for correlations between changes in 2-deoxy-2-[{sup 18}F]-fluoro-D-glucose (FDG)-PET (metabolism), {sup 15}O-PET (relative blood flow), regional radiation dose, follow-up time, and neuropsychological test scores. Results: Eleven subjects were enrolled and 6 completed follow-up studies. The PET data showed reduced FDG uptake, with average decreases of 2-6% in regions of the brain receiving greater than 40 Gy at 3 weeks' and 6 months' follow-up. The {sup 15}O-H{sub 2}O PET showed increases (<10%) at 3 weeks in relative regional blood flow in brain receiving greater than 30 Gy, but less at the 6-month follow-up studies. There were significant correlations between decreases in FDG uptake and increased scores from the Symptom Checklist-90-R, with an average increase in T score of 2 (p < 0.0001). The Wisconsin Card Sorting Test showed a significant correlation of decreased FDG uptake with increased errors and perseveration in test performance, with an average decrease in T score of 11 (p = 0.037). Conclusions: A dose-dependent response of CNS tissue was detected using FDG PET in this small number of patients. Decreases in CNS metabolism correlated with decreased performance on neuropsychological tests for problem solving, cognitive flexibility, and global measures of psychopathology. Additional research is needed to verify and define these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-19A-09: Propagation of Organ at Risk Contours for High Dose Rate Brachytherapy Planning for Cervical Cancer: A Deformable Image Registration Comparison

Purpose: To compare the performance of two deformable image registration (DIR) algorithms for contour propagation and to evaluate the accuracy of DIR for use with high dose rate (HDR) brachytherapy planning for cervical cancer. Methods: Five patients undergoing HDR ring and tandem brachytherapy were included in this retrospective study. All patients underwent CT simulation and replanning prior to each fraction (3–5 fractions total). CT-to-CT DIR was performed using two commercially available software platforms: SmartAdapt, Varian Medical Systems (Demons) and Velocity AI, Velocity Medical Solutions (B-spline). Fraction 1 contours were deformed and propagated to each subsequent image set and compared to contours manually drawn by an expert clinician. Dice similarity coefficients (DSC), defined as, DSC(A,B)=2(AandB)/(A+B) were calculated to quantify spatial overlap between manual (A) and deformed (B) contours. Additionally, clinician-assigned visual scores were used to describe and compare the performance of each DIR method and ultimately evaluate which was more clinically acceptable. Scoring was based on a 1–5 scale—with 1 meaning, “clinically acceptable with no contour changes” and 5 meaning, “clinically unacceptable”. Results: Statistically significant differences were not observed between the two DIR algorithms. The average DSC for the bladder, rectum and rectosigmoid were 0.82±0.08, 0.67±0.13 and 0.48±0.18, respectively. The poorest contour agreement was observed for the rectosigmoid due to limited soft tissue contrast and drastic anatomical changes, i.e., organ shape/filling. Two clinicians gave nearly equivalent average scores of 2.75±0.91 for SmartAdapt and 2.75±0.94 for Velocity AI—indicating that for a majority of the cases, more than one of the three contours evaluated required major modifications. Conclusion: Limitations of both DIR algorithms resulted in inaccuracies in contour propagation in the pelvic region, thus hampering the clinical utility of this technology. Further work is required to optimize these algorithms and take advantage of the potential of DIR for HDR brachytherapy planning.

60 APPLIED LIFE SCIENCES↗

Proposed Project Selection Method for Human Support Research and Technology Development (HSR&TD)

The purpose of HSR&TD is to deliver human support technologies to the Exploration Systems Mission Directorate (ESMD) that will be selected for future missions. This requires identifying promising candidate technologies and advancing them in technology readiness until they are acceptable. HSR&TD must select an may of technology development projects, guide them, and either terminate or continue them, so as to maximize the resulting number of usable advanced human support technologies. This paper proposes an effective project scoring methodology to support managing the HSR&TD project portfolio. Researchers strongly disagree as to what are the best technology project selection methods, or even if there are any proven ones. Technology development is risky and outstanding achievements are rare and unpredictable. There is no simple formula for success. Organizations that are satisfied with their project selection approach typically use a mix of financial, strategic, and scoring methods in an open, established, explicit, formal process. This approach helps to build consensus and develop management insight. It encourages better project proposals by clarifying the desired project attributes. We propose a project scoring technique based on a method previously used in a federal laboratory and supported by recent research. Projects are ranked by their perceived relevance, risk, and return - a new 3 R's. Relevance is the degree to which the project objective supports the HSR&TD goal of developing usable advanced human support technologies. Risk is the estimated probability that the project will achieve its specific objective. Return is the reduction in mission life cycle cost obtained if the project is successful. If the project objective technology performs a new function with no current cost, its return is the estimated cash value of performing the new function. The proposed project selection scoring method includes definitions of the criteria, a project evaluation questionnaire, and a scoring formula.

Jones, Harry↗

Software Template for Instruction in Mathematics

Intelligent Math Tutor (IMT) is a software system that serves as a template for creating software for teaching mathematics. IMT can be easily connected to artificial-intelligence software and other analysis software through input and output of files. IMT provides an easy-to-use interface for generating courses that include tests that contain both multiple-choice and fill-in-the-blank questions, and enables tracking of test scores. IMT makes it easy to generate software for Web-based courses or to manufacture compact disks containing executable course software. IMT also can function as a Web-based application program, with features that run quickly on the Web, while retaining the intelligence of a high-level language application program with many graphics. IMT can be used to write application programs in text, graphics, and/or sound, so that the programs can be tailored to the needs of most handicapped persons. The course software generated by IMT follows a "back to basics" approach of teaching mathematics by inducing the student to apply creative mathematical techniques in the process of learning. Students are thereby made to discover mathematical fundamentals and thereby come to understand mathematics more deeply than they could through simple memorization.

Shelton, Robert O.↗