Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Employing Sensitivity Derivatives to Estimate Uncertainty Propagation in CFD

Two methods that exploit the availability of sensitivity derivatives are successfully employed to predict uncertainty propagation through Computational Fluid Dynamics (CFD) code for an inviscid airfoil problem. An approximate statistical second-moment method and a Sensitivity Derivative Enhanced Monte Carlo (SDEMC) method are successfully demonstrated on a two-dimensional problem. First- and second-order sensitivity derivatives of code output with respect to code input are obtained through an efficient incremental iterative approach. Given uncertainties in statistically independent, random, normally distributed flow parameters (input variables); these sensitivity derivatives enable one to formulate first- and second-order Taylor Series approximations for the mean and variance of CFD output quantities. Additionally, incorporation of the first-order sensitivity derivatives into the data reduction phase of a conventional Monte Carlo (MC) simulation allows for improved accuracy in determining the first moment of the CFD output. Both methods are compared to results generated using a conventional MC method. The methods that exploit the availability of sensitivity derivatives are found to be valid when considering small deviations from input mean values.

Putko, Michele M.↗

Monte Carlo Estimates of Eigenvalue Sensitivity to System Dimensions using Kernel Density Estimators

In the last decade there has been an increasing interest in calculating sensitivity coefficients in order to quantify the impact of uncertainty in material properties and system parameters on quantities of interest. Extensive work has been done developing Monte Carlo methods to estimate eigenvalue sensitivity to material properties. While deterministic methods exist for determining the eigenvalue sensitivity to system dimensions, the use of Monte Carlo methods to efficiently calculate eigenvalue sensitivity coefficients to system dimensions is still an open topic. Current Monte Carlo methods for calculating eigenvalue sensitivity coefficients to system dimensions are inefficient. Direct Monte Carlo perturbations require two additional simulations of high statistical precision in order to determine the eigenvalue sensitivity to the location of a single boundary. If the sensitivity to the location of multiple surfaces are desired, two additional simulations must be run for each surface. Kiedrowski and Favorite extended continuous energy Monte Carlo methods for sensitivities of nuclear cross sections to calculate sensitivities to interface boundaries or system dimensions to create the only current alternative to direct Monte Carlo calculations. However this method relies on the simulation of additional random walks launched at each surface crossing event. The present method extends upon Kiedrowski's work and eliminates the inefficient portions of the calculation through the use of Kernel Density Estimators (KDEs). The new method efficiently estimates eigenvalue sensitivities to the uniform expansion or contraction of material interface boundaries or system dimensions, negligibly impacting the runtime performance of the Monte Carlo code. The new estimator is tested on bare and reflected critical configurations in spherical geometry and is compared to estimates obtained from direct Monte Carlo perturbations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low Background Materials and Assay: A Supplement to the Cosmic Frontier CF1 Summary.

Executive Summary The next generation of direct detection dark matter experiments will require stringent radiopurity in their target materials, internal instrumentation, and shielding components. A survey of major material assay facilities worldwide and of anticipated assay needs of generation 2 (G2) experiments indicate the current assay capability is marginally adequate in sensitivity and inadequate in throughput. High purity germanium (HPGe) gamma-ray assay has been the workhorse for material screening. It appears hundreds of samples will require screening at the limits of current achievable HPGe sensitivity. Mass spectroscopy methods and neutron activation analysis have demonstrated superior assay sensitivity in some specific cases. However, they are also currently throughput limited. In addition, both alpha/beta screening and radon emanation analysis at or beyond the current achievable sensitivity levels will be needed for dozens of samples. Experiments that follow G2 will have even more stringent material radiopurity specifications, exceeding current assay capabilities in both sensitivity and throughput. These screening needs must precede the commissioning of experiments by 3-5 years to inform design and quality control of components. Achieving the radiopurity goals of the next decade’s experiments will require investment in new techniques and tools to improve material assay sensitivity and throughput. Engineered low-background materials are a significant R&D expenditure, requiring developmental lead-time, and should benefit many end-user experiments. Reserving underground real estate for assay methods affected by cosmic rays (e.g. HPGe) and engineered radiopure materials activated by cosmic rays (e.g. electroformed copper) is judicious forward planning. In many cases, these spaces will require radon-suppressed sample preparation and material storage space. The above-mentioned survey of material assay facilities indicated very little development is taking place to improve sensitivity or throughput capability. In order to create the necessary infrastructure, it may help to form a consortium of low-background assay centers in the U.S that is managed by a scientific board with representatives from the community. This would provide for common use of existing screening facilities and a unified plan for new infrastructure and site development (see the Facilities White Paper). Such a loose organization already exists as AARM (Assay and Acquisition of Radiopure Materials), which is currently populating a community-wide materials database with published assay information. A more formal organization such as a Consortium is being actively investigated with DOE and NSF. Eventually, results of all screening performed in Consortium assay centers could be input directly to the open-access database, reducing duplication and providing for more efficient vendor selection.

Cooley-Sekula, Jodi↗

Advancing Reactive Tracer Methods for Measurement of Thermal Evolution in Geothermal Reservoirs (Final Report)

The injection of cold fluids into engineered geothermal system (EGS) and conventional geothermal reservoirs may be done to help extract heat from the subsurface or to maintain pressures within the reservoir (e.g., Rose et al., 2001). As these injected fluids move along fractures, they acquire heat from the rock matrix and remove it from the reservoir as they are extracted to the surface. A consequence of such injection is the migration of a cold-fluid front through the reservoir (Figure 1) that could eventually reach the production well and result in the lowering of the temperature of the produced fluids (thermal breakthrough). Efficient operation of an EGS as well as conventional geothermal systems involving cold-fluid injection requires accurate and timely information about thermal depletion of the reservoir in response to operation. In particular, accurate predictions of the time to thermal breakthrough and subsequent rate of thermal drawdown are necessary for reservoir management, design of fracture stimulation and well drilling programs, and forecasting of economic return. A potential method for estimating migration of a cold front between an injection well and a production well is through application of reactive tracer tests, using chemical whose rate of degradation is dependent on the reservoir temperature between the two wells (e.g., Robinson 1985). With repeated tests, the rate of migration of the thermal front can be determined, and the time to thermal breakthrough calculated. While the basic theory behind the concept of thermal tracers has been understood for some time, effective application of the method has yet to be demonstrated. This report describes results of a study that used several methods to investigate application of reactive tracers to monitoring the thermal evolution of a geothermal reservoir. These methods included (1) mathematical investigation of the sensitivity of known and hypothetical reactive tracers, (2) laboratory testing of novel tracers that would improve method sensitivity, (3) development of a software tool for design and interpretation of reactive tracer tests and (4) field testing of the reactive tracer temperature monitoring concept.

15 GEOTHERMAL ENERGY↗

Utilization of ACE nuclear data file toolkit ACEtk to calculate relative sensitivity coefficients of point-kinetics parameters

Sensitivity and uncertainty methods are quintessential for nuclear criticality safety and experiment design. This type of analysis relies on calculations of sensitivity coefficients; sensitivity coefficients of the effective neutron multiplication factor with respect to some nuclear data are predominantly calculated and used. As a part of the Laboratory Directed Research & Development project EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) at Los Alamos National Laboratory, sensitivity coefficients of many radiation detector measurement responses with respect to nuclear data were investigated. Specifically, this paper outlines a method to calculate point-kinetics parameters relative sensitivity coefficients with respect to nuclear data. Point-kinetics parameters such as the prompt neutron decay constant, effective delayed neutron fraction, and neutron generation time are especially important to experimenters and reactor operators designing systems with dynamic neutron populations. This method couples capabilities of the ACE (A Compact ENDF) nuclear data file toolkit, ACEtk, with the ability to load cross sections into the radiation transport code Monte Carlo N-Particle (MCNP). In conclusion, key aspects of optimizing this method for a particular application and sensitivity profiles of the Jezebel criticality experiment are examined and discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A discourse on sensitivity analysis for discretely-modeled structures

A descriptive review is presented of the most recent methods for performing sensitivity analysis of the structural behavior of discretely-modeled systems. The methods are generally but not exclusively aimed at finite element modeled structures. Topics included are: selections of finite difference step sizes; special consideration for finite difference sensitivity of iteratively-solved response problems; first and second derivatives of static structural response; sensitivity of stresses; nonlinear static response sensitivity; eigenvalue and eigenvector sensitivities for both distinct and repeated eigenvalues; and sensitivity of transient response for both linear and nonlinear structural response.

Adelman, Howard M.↗

Validation of Nuclear Data Sensitivity Calculations by the MCNP PERT Card [Poster]

This work validates a method of estimating sensitivities that utilized the MCNP PERT card and tallies. The agreement of the PERT card and Brute Force results proves the validity of calculating nuclear data sensitivities by use of the MCNP PERT card, especially at higher energies. The overall agreement will be easier to understand once an uncertainty analysis is completed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparisons of one- and two- interface methods for tunnel wall interference calculation

Tunnel wall interference in two-dimensional subsonic flow can be analytically calculated on the basis of the one- or two-interface method. The application of numerical integration by means of matrix multiplication to both methods has been found to significantly reduce CPU time in on-line operation. An investigation of the sensitivity of these methods to random velocity-measurement disturbances shows the one-interface method to be less sensitive to measurement errors, and therefore to be preferable for practical applications.

Lo, C. F.↗

Sensitivity and uncertainty analysis of reactivities for UO2 and MOX fueled PWR cells

The purpose of this paper is to apply our improved method for calculating sensitivities and uncertainties of reactivity responses for UO{sub 2} and MOX fueled pressurized water reactor cells. The improved method has been used to calculate sensitivity coefficients relative to infinite dilution cross-sections, where the self-shielding effect is taken into account. Two types of reactivities are considered: Doppler reactivity and coolant void reactivity, for each type of reactivity, the sensitivities are calculated for small and large perturbations. The results have demonstrated that the reactivity responses have larger relative uncertainty than eigenvalue responses. In addition, the uncertainty of coolant void reactivity is much greater than Doppler reactivity especially for large perturbations. The sensitivity coefficients and uncertainties of both reactivities were verified by comparing with SCALE code results using ENDF/B-VII library and good agreements have been found.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The helium abundance of Saturn from Voyager measurements

The helium abundance in the atmosphere of Saturn is obtained from Voyager measurements by two methods. The first method combines infrared spectra and vertical profiles derived from radio occultation measurements and yields a hydrogen mole fraction of q = 0.963 + or - 0.024 corresponding to a helium mass fraction of Y = 0.06 + or - 0.05. The estimated errors are primarily due to uncertainties in the radio occultation profile and in the abundance of methane, which contributes significantly to the mean molecular weight. The second method is based on the direct inversion of infrared spectra and yields values consistent with those from the first method; however, examination of the sensitivities of the two methods indicates that in the Saturnian case the first approach provides more accurate results. Comparison of the helium abundance of Saturn with that of Jupiter and the sun suggests that helium precipitation is significant in Saturn but may not have begun in Jupiter.

Conrath, B. J.↗

Using Whispering-Gallery-Mode Resonators for Refractometry

A method of determining the refractive and absorptive properties of optically transparent materials involves a combination of theoretical and experimental analysis of electromagnetic responses of whispering-gallery-mode (WGM) resonator disks made of those materials. The method was conceived especially for use in studying transparent photorefractive materials, for which purpose this method affords unprecedented levels of sensitivity and accuracy. The method is expected to be particularly useful for measuring temporally varying refractive and absorptive properties of photorefractive materials at infrared wavelengths. Still more particularly, the method is expected to be useful for measuring drifts in these properties that are so slow that, heretofore, the properties were assumed to be constant. The basic idea of the method is to attempt to infer values of the photorefractive properties of a material by seeking to match (1) theoretical predictions of the spectral responses (or selected features thereof) of a WGM of known dimensions made of the material with (2) the actual spectral responses (or selected features thereof). Spectral features that are useful for this purpose include resonance frequencies, free spectral ranges (differences between resonance frequencies of adjacently numbered modes), and resonance quality factors (Q values). The method has been demonstrated in several experiments, one of which was performed on a WGM resonator made from a disk of LiNbO3 doped with 5 percent of MgO. The free spectral range of the resonator was approximately equal to 3.42 GHz at wavelengths in the vicinity of 780 nm, the smallest full width at half maximum of a mode was approximately equal to 50 MHz, and the thickness of the resonator in the area of mode localization was 30 microns. In the experiment, laser power of 9 mW was coupled into the resonator with an efficiency of 75 percent, and the laser was scanned over a frequency band 9 GHz wide at a nominal wavelength of approximately equal to 780 nm. Resonance frequencies were measured as functions of time during several hours of exposure to the laser light. The results of these measurements, plotted in the figure, show a pronounced collective frequency drift of the resonator modes. The size of the drift has been estimated to correspond to a change of 8.5 x 10(exp -5) in the effective ordinary index of refraction of the resonator material.

Matsko, Andrey↗

Radiation Therapy Photon Beams Dose Conformation According to Dose Distribution Around Intracavitary-Applied Brachytherapy Sources

Intracavitary application of brachytherapy sources followed by external beam radiation is essential for the local treatment of carcinoma of the cervix. Due to very high doses to the central portion of the target volume delivered by brachytherapy sources, this part of the target volume must be shielded while being irradiated by photon beams. Several shielding techniques are available, from rectangular block and standard cervix wedge to more precise, customized step wedge filters. Because the calculation of a step wedge filter's shape was usually based on effective attenuation coefficient, an approach that accounts, in a more precise way, for the scattered radiation, is suggested. The method was verified under simulated clinical conditions using film dosimetry. Measured data for various compensators were compared to the numerically determined sum of the dose distribution around brachytherapy sources and one of compensated beam. Improvements in total dose distribution are demonstrated, using our method. Agreement between calculation and measurements were within 3%. Sensitivity of the method on sources displacement during treatment has also been investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient Distance-based Global Sensitivity Analysis for Terrestrial Ecosystem Modeling

Sensitivity analysis in terrestrial ecosystem modeling is important for understanding controlling processes, guiding model development, and targeting new observations to reduce parameter and prediction uncertainty. Complex and computationally expensive terrestrial ecosystem models (TEM) limit the number of ensemble simulations, requiring sophisticated and efficient methods to analyze sensitivities of multiple model responses to different types of parameter uncertainties. In this study, we propose a distance-based global sensitivity analysis (DGSA) method. DGSA first classifies model response samples into a small set of discrete classes and then calculates the distance between parameter frequency distributions in different classes to measure the parameter sensitivity. The principle is that, if the parameter distribution is the same in each class, then the model response is insensitive to the parameter, while a large difference in the distributions indicates the parameter is influential to the response. Built on this idea, DGSA can be applied to analyze sensitivity of a single and a group of responses to different kinds of parameter uncertainties including continuous, discrete and even stochastic. Besides the main-effect sensitivity from a single parameter, DGSA can also quantify the sensitivity from parameter interactions. Additionally, DGSA is computationally efficient which can use a small number of model evaluations to obtain an accurate and statistically significant result. We applied DGSA to two TEMs, one having eight parameters and three kinds of model responses, and the other having 47 parameters and a long-period response. We demonstrated that DGSA can be used for sensitivity problems with multiple responses and high-dimensional parameters efficiently.

Lu, Dan↗

Evaluation of the minimal replication time of Cauliflower mosaic virus in different hosts

Though the duration of a single round of replication is an important biological parameter, it has been determined for only few viruses. Here, this parameter was determined for Cauliflower mosaic virus (CaMV) in transfected protoplasts from different hosts: the highly susceptible Arabidopsis and turnip, and Nicotiana benthamiana, where CaMV accumulates only slowly. Four methods of differing sensitivity were employed: labelling of (1) progeny DNA and (2) capsid protein, (3) immunocapture PCR,, and (4) progeny-specific PCR. The first progeny virus was detected about 21 h after transfection. This value was confirmed by all methods, indicating that our estimate was not biased by the sensitivity of the detection method, and approximated the actual time required for one round of CaMV replication. Unexpectedly, the replication kinetics were similar in the three hosts; suggesting that slow accumulation of CaMV in Nicotiana plants is determined by non-optimal interactions in other steps of the infection cycle.

60 APPLIED LIFE SCIENCES↗

Image quality in thoracic 4D cone-beam CT: A sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing

Purpose: Respiratory signal, binning method, and reconstruction algorithm are three major controllable factors affecting image quality in thoracic 4D cone-beam CT (4D-CBCT), which is widely used in image guided radiotherapy (IGRT). Previous studies have investigated each of these factors individually, but no integrated sensitivity analysis has been performed. In addition, projection angular spacing is also a key factor in reconstruction, but how it affects image quality is not obvious. An investigation of the impacts of these four factors on image quality can help determine the most effective strategy in improving 4D-CBCT for IGRT. Methods: Fourteen 4D-CBCT patient projection datasets with various respiratory motion features were reconstructed with the following controllable factors: (i) respiratory signal (real-time position management, projection image intensity analysis, or fiducial marker tracking), (ii) binning method (phase, displacement, or equal-projection-density displacement binning), and (iii) reconstruction algorithm [Feldkamp–Davis–Kress (FDK), McKinnon–Bates (MKB), or adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS)]. The image quality was quantified using signal-to-noise ratio (SNR), contrast-to-noise ratio, and edge-response width in order to assess noise/streaking and blur. The SNR values were also analyzed with respect to the maximum, mean, and root-mean-squared-error (RMSE) projection angular spacing to investigate how projection angular spacing affects image quality. Results: The choice of respiratory signals was found to have no significant impact on image quality. Displacement-based binning was found to be less prone to motion artifacts compared to phase binning in more than half of the cases, but was shown to suffer from large interbin image quality variation and large projection angular gaps. Both MKB and ASD-POCS resulted in noticeably improved image quality almost 100% of the time relative to FDK. In addition, SNR values were found to increase with decreasing RMSE values of projection angular gaps with strong correlations (r ≈ −0.7) regardless of the reconstruction algorithm used. Conclusions: Based on the authors’ results, displacement-based binning methods, better reconstruction algorithms, and the acquisition of even projection angular views are the most important factors to consider for improving thoracic 4D-CBCT image quality. In view of the practical issues with displacement-based binning and the fact that projection angular spacing is not currently directly controllable, development of better reconstruction algorithms represents the most effective strategy for improving image quality in thoracic 4D-CBCT for IGRT applications at the current stage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Life cycle assessment of TV sets in China: A case study of the impacts of CRT monitors

Along with the rapid increase in both production and use of TV sets in China, there is an increasing awareness of the environmental impacts related to the accelerating mass production, electricity use, and waste management of these sets. This paper aims to describe the application of life cycle assessment (LCA) to investigate the environmental performance of Chinese TV sets. An assessment of the TV set device (focusing on the Cathode Ray Tube (CRT) monitor) was carried out using a detailed modular LCA based on the international standards of the ISO 14040 series. The LCA was constructed using SimaPro software version 7.2 and expressed with the Eco-indicator' 99 life cycle impact assessment method. For a sensitivity analysis of the overall LCA results, the CML method was used in order to estimate the influence of the choice of the assessment method on the results. Life cycle inventory information was compiled by Ecoinvent 2.2 databases, combined with literature and field investigations on the current Chinese situation. The established LCA study shows that the use stage of such devices has the highest environmental impact, followed by the manufacturing stage. In the manufacturing stage, the CRT and the Printed Circuit Board (PCB) are those components contributing the most environmental impacts. During the use phase, the environmental impacts are due entirely to the methods of electricity generation used to run them, since no other aspects were taken into account for this phase. The final processing step-the end-of-life stage-can lead to a clear environmental benefit when the TV sets are processed through the formal dismantling enterprises in China.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design sensitivity analysis with Applicon IFAD using the adjoint variable method

A numerical method is presented to implement structural design sensitivity analysis using the versatility and convenience of existing finite element structural analysis program and the theoretical foundation in structural design sensitivity analysis. Conventional design variables, such as thickness and cross-sectional areas, are considered. Structural performance functionals considered include compliance, displacement, and stress. It is shown that calculations can be carried out outside existing finite element codes, using postprocessing data only. That is, design sensitivity analysis software does not have to be imbedded in an existing finite element code. The finite element structural analysis program used in the implementation presented is IFAD. Feasibility of the method is shown through analysis of several problems, including built-up structures. Accurate design sensitivity results are obtained without the uncertainty of numerical accuracy associated with selection of a finite difference perturbation.

Frederick, Marjorie C.↗

A noise source identification technique using an inverse Helmholtz integral equation method

A technique is developed which utilizes numerical models and field pressure information to characterize acoustic fields and identify acoustic sources. The numerical models are based on boundary element numerical procedures. Either pressure, velocity, or passive boundary conditions, in the form of impedance boundary conditions, may be imposed on the numerical model. Alternatively, if no boundary information is known, a boundary condition can be left unspecified. Field pressure data may be specified to overdetermine the numerical problem. The problem is solved numerically for the complete sound field from which the acoustic sources may be determined. The model can then be used to idenfify acoustic intensity paths in the field. The solution can be modified and the model used to evaluate design alternatives. In this investigation the method is tested analytically and verified. In addition, the sensitivity of the method to random and bias error in the input data is demonstrated.

Gardner, B. K.↗