At least 847 records · Page 47

Development and Evaluation of Occupancy-Aware HVAC Control for Residential Building Energy Efficiency and Occupant Comfort

Occupancy-aware heating, ventilation, and air conditioning (HVAC) control offers the opportunity to reduce energy use without sacrificing thermal comfort. Residential HVAC systems often use manually-adjusted or constant setpoint temperatures, which heat and cool the house regardless of whether it is needed. By incorporating occupancy-awareness into HVAC control, heating and cooling can be used for only those time periods it is needed. Yet, bringing this technology to fruition is dependent on accurately predicting occupancy. Non-probabilistic prediction models offer an opportunity to use collected occupancy data to predict future occupancy profiles. Smart devices, such as a connected thermostat, which already include occupancy sensors, can be used to provide a continually growing collection of data that can then be harnessed for short-term occupancy prediction by compiling and creating a binary occupancy prediction. Real occupancy data from six homes located in Colorado is analyzed and investigated using this occupancy prediction model. Results show that non-probabilistic occupancy models in combination with occupancy sensors can be combined to provide a hybrid HVAC control with savings on average of 5.0% and without degradation of thermal comfort. Model predictive control provides further opportunities, with the ability to adjust the relative importance between thermal comfort and energy savings to achieve savings between 1% and 13.3% depending on the relative weighting between thermal comfort and energy savings. In all cases, occupancy prediction allows the opportunity for a more intelligent and optimized strategy to residential HVAC control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comparative Analysis of Infrastructure-Based Perception Sensors for Intelligent Transportation Systems

The rise of privatized and public investment in smart city infrastructure and intelligent transportation systems has generated a heightened demand for perception sensors that effectively track and detect objects while being reliable in diverse weather and lighting conditions. This growing demand for perception sensors has accelerated their development and enhanced their capabilities. With these new capabilities, it is challenging to determine the most suitable sensing unit to use in each situation. Therefore, it is essential to have a comprehensive understanding of the benefits and limitations of each sensing unit to effectively leverage their capabilities. The purpose of this paper is to provide a detailed evaluation of various perception sensors. Additionally, this paper will demonstrate the benefits of combining multiple perception sensors, which complement each other by addressing data gaps inherent to single-sensor systems, to facilitate the creation of a digital twin that models the real world. The Infrastructure, Perception, and Control (IPC) team will conduct data analysis using data collected through field testing at traffic intersections in Colorado Springs, Colorado, to make comparisons between sensors. This research aims to provide clear and concise information about modern perception systems, which will support the development of intelligent transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

3D printed high performance strain sensors for high temperature applications

Realization of high temperature physical measurement sensors, which are needed in many of the current and emerging technologies, is challenging due to the degradation of their electrical stability by drift currents, material oxidation, thermal strain, and creep. In this paper, for the first time, we demonstrate that 3D printed sensors show a metamaterial-like behavior, resulting in superior performance such as high sensitivity, low thermal strain, and enhanced thermal stability. The sensors were fabricated using silver (Ag) nanoparticles (NPs), using an advanced Aerosol Jet based additive printing method followed by thermal sintering. The sensors were tested under cyclic strain up to a temperature of 500 °C and showed a gauge factor of 3.15 ± 0.086, which is about 57% higher than that of those available commercially. The sensor thermal strain was also an order of magnitude lower than that of commercial gages for operation up to a temperature of 500 °C. An analytical model was developed to account for the enhanced performance of such printed sensors based on enhanced lateral contraction of the NP films due to the porosity, a behavior akin to cellular metamaterials. Here, the results demonstrate the potential of 3D printing technology as a pathway to realize highly stable and high-performance sensors for high temperature applications.

47 OTHER INSTRUMENTATION↗

A surface acoustic wave hydrogen sensor with tin doped indium oxide layers for intermediate temperatures

We report high temperature surface acoustic wave (SAW) gas sensors with conducting sensing layers require tuning of the sheet conductivity for optimal response. Conducting metal oxides are attractive sensing materials for their tunable electronic properties and high thermal stability, amongst others. Here, we have investigated the application of indium oxide (IO) and indium tin oxide (ITO) films on langasite (LGS)-based SAW reflective delay line sensor devices for monitoring hydrogen at 350 °C. Specifically, we modeled the effect of the IO and ITO sensing layer thickness on the wave velocity, attenuation, and effective electromechanical coefficient. This was followed by an experimental demonstration of tuning of the ITO film sheet conductivity by controlling the dopant concentration and yielding an improvement in the sensor sensitivity. The current study provides a pathway towards the development of conductivity-based sensing layers for high temperature SAW gas sensors with improved sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Order Numerical Methods for the Dynamic SGS Model of Turbulent Flows with Shocks

Simulation of turbulent flows with shocks employing subgrid-scale (SGS) filtering may encounter a loss of accuracy in the vicinity of a shock. This paper addresses the accuracy improvement of LES of turbulent flows in two ways: (a) from the SGS model standpoint and (b) from the numerical method improvement standpoint. In an internal report, Kotov et al. ( “High Order Numerical Methods for large eddy simulation (LES) of Turbulent Flows with Shocks”, CTR Tech Brief, Oct. 2014, Stanford University), we performed a preliminary comparative study of different approaches to reduce the loss of accuracy within the framework of the dynamic Germano SGS model. The high order low dissipative method of Yee & Sjögreen (2009) using local flow sensors to control the amount of numerical dissipation where needed is used for the LES simulation. The considered improved dynamics model approaches include applying the one-sided SGS test filter of Sagaut & Germano (2005) and/or disabling the SGS terms at the shock location. For Mach 1.5 and 3 canonical shock-turbulence interaction problems, both of these approaches show a similar accuracy improvement to that of the full use of the SGS terms. The present study focuses on a five levels of grid refinement study to obtain the reference direct numerical simulation (DNS) solution for additional LES SGS comparison and approaches. As a result, one of the numerical accuracy improvements included here applies Harten's subcell resolution procedure to locate and sharpen the shock, and uses a one-sided test filter at the grid points adjacent to the exact shock location.

97 MATHEMATICS AND COMPUTING↗

Lightweight Integrated Optical Sensor for Atmospheric Measurements on Mobile Platforms

The goal of the Phase I program was to develop a novel open path sensor platform technology based on integration of semiconductor waveguides with efficient optoelectronic components on a monolithic platform. The successful Phase I effort resulted in demonstration of a novel optical resonator structure based on semiconductor high contrast gratings (HCGs) that will enable implementation of an ultra-compact, low-power gas sensor suitable for use on mobile platforms. Extensive numerical modeling was performed to design a device optimized for measuring CO2 at a wavelength for which a laser was available for proof of concept. Devices were fabricated and tested to match the target wavelength, angle, and operating temperature. This demonstration is the first implementation of HCGs at the wavelengths of interest and shows the flexibility of the proposed architecture for gas sensing applications. The measured cavity Q was lower than anticipated due to fabrication process challenges. The PSI and UC Berkeley team has identified solutions to these challenges and will produce optimized devices in a Phase II program where a prototype sensor will be fabricated and tested.

54 ENVIRONMENTAL SCIENCES↗

Instrumentation and Data Analysis Supporting the Transient Rod Pneumatic System Design Study at the Annular Core Research Reactor

The Sandia National Laboratories Annular Core Research Reactor (ACRR) has been experiencing intermittent failures of its pneumatically operated transient rod system. The most frequent failures have been to the dashpot rod where it connects to the upper aluminum connecting rod. Within the three systems, Transient Rod (TR) A has the most frequent failures. In order to conduct the pulse operations, the Transient Rods are pneumatically driven to quickly remove "poison" from the reactor core. During these pulse operations increased forces and vibrations are placed on the TR system. In an effort to fix these problems, Sandia's TA-V Nuclear Reactor and Systems Engineering Department (Engineering Department) has started an extensive Transient Rod Pneumatic System Design Study. The goal of this study is to determine the causes of the elevated failure rates in TR A. This necessitates an increased understanding of the dynamics in the TR systems. This report will cover the approach taken and reasoning behind the choices of instrumentation, calibration, data collection and data analysis used to diagnose these failures. In order to determine the types and specifications for the sensors that will be installed, estimates of the TR system performance needed to be determined. Using known and assumed parameters, mechanical and thermodynamic models were developed, and calculations performed to estimate ranges of displacement, speed, and acceleration experienced by the transient rod system. After some preliminary data collection, the thermodynamic models were refined for better accuracy. After installation of the full suite of sensors, data can be collected and analyzed in order to determine the cause of the increased failures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of long-term spatio-temporal radiofrequency electromagnetic field exposure

Highlights: • A year's worth of RF-EMF data is collected in an urban sensor network is analysed. • A full spatio-temporal model of the RF-EMF exposure in the study area is built. • Short-term variations of the RF-EMF exposure are collected in temporal profiles. • Models using data collected at different instants are improved by adjusting for time. As both the environment and telecommunications networks are inherently dynamic, our exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) at an arbitrary location is not at all constant in time. In this study, more than a year's worth of measurement data collected in a fixed low-cost exposimeter network distributed over an urban environment was analysed and used to build, for the first time, a full spatio-temporal surrogate model of outdoor exposure to downlink Global System for Mobile Communications (GSM) and Universal Mobile Telecommunications System (UMTS) signals. Though no global trend was discovered over the measuring period, the difference in measured exposure between two instances could reach up to 42 dB (a factor 12,000 in power density). Furthermore, it was found that, taking into account the hour and day of the measurement, the accuracy of the surrogate model in the area under study was improved by up to 50% compared to models that neglect the daily temporal variability of the RF signals. However, further study is required to assess the extent to which the results obtained in the considered environment can be extrapolated to other geographic locations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Model of a fibreoptic phase-sensitive reflectometer and its comparison with the experiment

A statistical model describing the Rayleigh-scattering reflectograms of narrowband Gaussian pulses in optical fibres is constructed taking into account linear (the finite spectral linewidth because of frequency fluctuations, finite frequency band of the photodetector) and nonlinear (modulation instability) effects influencing the reflectograms' visibility. The model is compared with the experiment, demonstrating the adequacy of the theoretical description. The possibilities of obtaining optimal parameters, important for practical applications of the phase-sensitive reflectometer as a distributed fibreoptic intrusion sensor are discussed. (optical fibres)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An integrated electrochemical device based on immunochromatographic test strip and enzyme labels for sensitive detection of disease-related biomarkers

A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. The sensor was further utilized to detect HBsAg in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population

59 BASIC BIOLOGICAL SCIENCES↗

Thermodynamic Cloud Phase Classifications Using Machine Learning at NSA and ANX

Vertically resolved thermodynamic cloud phase classifications are essential for studies of atmospheric cloud and precipitation processes. The Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) THERMOCLDPHASE Value-Added Product (VAP) uses a multi-sensor approach to classify thermodynamic cloud phase by combining lidar backscatter and depolarization, radar reflectivity, Doppler velocity, spectral width, microwave radiometer-derived liquid water path, and radiosonde temperature measurements. The measured voxels are classified as ice, snow, mixed-phase, liquid (cloud water), drizzle, rain, and liq_driz (liquid+drizzle). We use this product as the ground truth to train three machine learning (ML) models to predict the thermodynamic cloud phase from multi-sensor remote sensing measurements taken at the ARM North Slope of Alaska (NSA) observatory: a random forest (RF), a multilayer perceptron (MLP), and a convolutional neural network (CNN) with a U-Net architecture. Evaluations against the outputs of the THERMOCLDPHASE VAP with one year of data show that the CNN outperforms the other two models, achieving the highest test accuracy, F1-score, and mean Intersection over Union (IOU). Analysis of ML confidence scores shows ice, rain, and snow have higher confidence scores, followed by liquid, while mixed, drizzle, and liq_driz have lower scores. Feature importance analysis reveals that the mean Doppler velocity and vertically resolved temperature are the most influential datastreams for ML thermodynamic cloud phase predictions. The ML models’ generalization capacity is further evaluated by applying them at another Arctic ARM site in Norway using data taken during the ARM Cold-Air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) field campaign. Finally, we evaluate the ML models’ response to simulated instrument outages and signal degradation.

54 ENVIRONMENTAL SCIENCES↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗

Mobile Sensing for Wind Field Estimation in Wind Farms: Preprint

This paper introduces a novel approach for estimating the wind field over an entire wind farm using a mobile sensor to collect limited amounts of data. The proposed method estimates the boundary conditions of a simplified turbine wake model by computing the model sensitivity matrix and using a recursive least-squares algorithm to recover the model parameters from the wind field measurements. To address the fact that it is not practical to take measurements across the entire wind farm, the proposed method classifies each area on the map based on its sensitivity to parameter variations. This classification is then used to generate a suitable path for a mobile sensor, which is charged with collecting data for the recursive least-squares algorithm. The proposed framework can successfully estimate the model boundary conditions using just the measurements collected along the path of the mobile sensor. This preliminary result paves the way for using real-time wind field estimates for the coordinated control of all the turbines within a wind farm.

estimation↗

The magnetic structure of long-wavelength magnetohydrodynamic modes in current-carrying stellarator plasmas

Magnetic field fluctuations are observed in current-carrying stellarator plasmas when the rotational transform is close to a rational value at the edge of the plasma. At low plasma pressure, these fluctuations are associated with perturbed currents parallel to the equilibrium magnetic field lines. A model for these magnetohydrodynamic modes in a low-β, three-dimensional stellarator equilibria has been developed. A set of helical current filaments are constrained to mimic the structure of magnetic field lines on rational surfaces derived from three-dimensional (3D) equilibrium reconstructions. Transformation to straight field line coordinates then allows fitting of the poloidal magnetic sensor data to a single harmonic function, which fixes the modeled toroidal mode structure via the field line flow geometry. The developed procedure accurately captures phase and amplitude variation for m/n = 3/2, 3/1, and 4/1 modes in the 3D equilibria of the compact toroidal hybrid experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Meteorological Conditions in Urban Sites in Knoxville, USA. 2025

This 2025 dataset, which contains five csv files, reports hourly air temperature, wind speed, solar radiation, incident short wave, reflected short wave, incident long wave, emitted long wave, net radiation, and photosynthetically active radiation (PAR) data measured in urban parks in Knoxville, Tennessee, USA. The sites include Cumberland Estates Park (CEP), Socially Equal Energy Efficient Development (SEEED), West Hills Park (WHP), West View Park (WVP), and Victor Ashe Park (VAP). Air temperature, wind speed, and solar radiation data were obtained from a METER ATMOS 41 All-in-One Weather Station (Pullman, Washington, USA). Incident and emitted radiation (shortwave and longwave) measurements were made using an Apogee (Logan, Utah, USA) net radiometer (Model SN-500-SS). The SQ-521 Full-Spectrum Quantum sensor (Apogee Instruments, Inc) recorded the PAR. The measurement data for all the sites started on January 1, 2025. and all measurement ended on December 31, 2025. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

Meteorological Conditions in Urban Sites in Knoxville, USA. 2023

This 2023 dataset, which contains four csv files, reports hourly air temperature, wind speed, solar radiation, incident short wave, reflected short wave, incident long wave, emitted long wave, net radiation, and photosynthetically active radiation (PAR) data measured in urban parks in Knoxville, Tennessee, USA. The sites include Cumberland Estates Park (CEP), Socially Equal Energy Efficient Development (SEEED), West Hills (WHP), and Victor Ashe Park (VAP). Air temperature, wind speed and direction, and solar radiation data were obtained from a METER ATMOS 41 All-in-One Weather Station (Pullman, Washington, USA). Incident and emitted radiation (shortwave and longwave) measurements were made using an Apogee (Logan, Utah, USA) net radiometer (Model SN-500-SS). The SQ-521 Full-Spectrum Quantum sensor (Apogee Instruments, Inc) recorded the PAR. The measurement data for CEP, SEEED, and VAP started on July 1, 2023, while WHP started on August 26, 2023. All measurement ended on December 31, 2023. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

Automated Design Space Exploration with Aspen

Architects and applications scientists often use performance models to explore a multidimensional design space of architectural characteristics, algorithm designs, and application parameters. With traditional performance modeling tools, these explorations forced users to first develop a performance model and then repeatedly evaluate and analyze the model manually. These manual investigations proved laborious and error prone. More importantly, the complexity of this traditional process often forced users to simplify their investigations. To address this challenge of design space exploration, we extend our Aspen (Abstract Scalable Performance Engineering Notation) language with three new language constructs: user-defined resources, parameter ranges, and a collection of costs in the abstract machine model. Then, we use these constructs to enable automated design space exploration via a nonlinear optimization solver. We show how four interesting classes of design space exploration scenarios can be derived from Aspen models and formulated as pure nonlinear programs. The analysis tools are demonstrated using examples based on Aspen models for a three-dimensional Fast Fourier Transform, the CoMD molecular dynamics proxy application, and the DARPA Streaming Sensor Challenge Problem. Our results show that this approach can compose and solve arbitrary performance modeling questions quickly and rigorously when compared to the traditional manual approach.

Spafford, Kyle L.↗

Utilizing machine learning to improve the precision of fluorescence imaging of cavity-generated spin squeezed states

We present a supervised learning model to calibrate the photon collection rate during the fluorescence imaging of cold atoms. The linear regression model finds the collection rate at each location on the sensor such that the atomic population difference equals that of a highly precise optical cavity measurement. This 192 variable regression results in a measurement variance 27% smaller than our previous single variable regression calibration. The measurement variance is now in agreement with the theoretical limit due to other known noise sources. This model efficiently trains in less than a minute on a standard personal computer's CPU and requires less than 10 min of data collection. Furthermore, the model is applicable across a large change in population difference and across data collected on different days.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗