Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Time-resolved measurement of the quantum states of photons using two-photon interference with short-time reference pulses

To fully utilize the energy-time degree of freedom of photons for optical quantum-information processes, it is necessary to control and characterize the temporal quantum states of the photons at extremely short time scales. For measurements of the temporal coherence of the quantum states beyond the time resolution of available detectors, two-photon interference with a photon in a short-time reference pulse may be a viable alternative. In this paper, we derive the temporal measurement operators for the bunching statistics of a single-photon input state with a photon from a weak coherent reference pulse. It is shown that the effects of the pulse shape of the reference pulse can be expressed in terms of a spectral filter selecting the bandwidth within which the measurement can be treated as an ideal projection on eigenstates of time. For full quantum tomography, temporal coherence can be determined by using superpositions of reference pulses at two different times. Moreover, energy-time entanglement can be evaluated based on the two-by-two entanglement observed in the coherences between pairs of detection times.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast dynamics of a fermion chain in a terahertz field-driven optical cavity

In this article, we study the effect of a terahertz field-driven single cavity mode for ultrafast control of a fermion chain with dissipation-induced nonlinearity and quadratic coupling to an infrared-active phonon mode. Unlike the first-order phase transition in the nonequilibrium steady state of the system without a cavity or with a high-quality cavity, we find that a realistic dissipation in a low-quality driven cavity process prevents such a transition. Without realistic photon loss from the cavity, the transition only survives for the lower phonon-polariton branch with strong drive; a weak laser field fails to induce the phase transition and renders the polaritons symmetrical. The ability to control the phase transition is crucial for realizing strongly modulated steady states; we propose experimentally feasible regimes where this occurs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a Photon Counting System for Differential Lidar Signal Detection

Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.

Elsayed-Ali, Hani↗

Quantum Optics with Superconducting Circuits: From Single Photons to Schrodinger Cats

Over the last decade and a half, superconducting circuits have advanced to the point where we can generate and detect highly-entangled states, and perform universal quantum gates. Meanwhile, the coherence properties of these systems have improved more than 10,000-fold. I will describe recent experiments, such as the latest advance in coherence using a three-dimensional implementation of qubits interacting with microwave cavities, called “3D circuit QED.” The control and strong interactions possible in superconducting circuits make it possible to generate non-classical states of light, including large superpositions known as “Schrodinger cat” states. This field has many interesting prospects both for applications in quantum information processing, and fundamental investigations of the boundary between the macroscopic classical world and the microscopic world of the quantum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Femtosecond Time-Delay X-Ray Holography

X-ray free-electron lasers (XFELs) will produce photon pulses with a unique and desirable combination of properties. Their short X-ray wavelengths allow penetration into materials and the ability to probe structure at and below the nanometer scale. Their ultra-short duration gives information about this structure at the fundamental time-scales of atoms and molecules. The extreme intensity of the pulses will allow this information to be acquired in a single shot, so that these studies can be carried out on non-repeatable processes or on weakly-scattering objects that will be modified by the pulse. A fourth property of XFEL pulses is their high transverse coherence, which brings the promise of decades of innovation in visible optics to the X-ray regime, such as holography, interferometry, and laser-based imaging. Making an effective use of XFEL pulses, however, will benefit from innovations that are new to both X-ray science and coherent optics. One such innovation is the new method of time-delay X-ray holography [1], recently demonstrated at the FLASH FEL at DESY in Hamburg, to measure the evolution of objects irradiated by intense pulses. One of the pressing questions about the high-resolution XFEL imaging and characterization of non-periodic or weakly-scattering objects is the effect of the intense FEL pulse on the object, during the interaction with that pulse. The method of single-particle diffraction imaging [2] requires a stream of reproducible particles (e.g. a protein complex or virus) inserted into the beam, whereby a coherent X-ray diffraction pattern is recorded. The pulse will completely destroy the object, but if the pulse is short enough the diffraction pattern will represent the undamaged object. This ultrafast flash imaging was demonstrated at the FLASH FEL using test objects that included microfabricated patterns in silicon nitride foils [3]. Those experiments showed that no damage occurred during the 30 fs duration pulse. However, in those experiments the imaging resolution was limited by the long 32 nm wavelength at which the facility was then operating. We wished to dramatically increase our sensitivity to the particles explosions, to be able to increase the understanding of the dynamics of particles and predict the imaging performance at XFELs such as the LCLS. This was done in two ways in a single experiment: by holographically measuring the time evolution of the particle at times after the pulse had pass through the object; and by making an interferometric measurement of the change in the optical path through the object. The experimental technique, time-delay holography, achieved a time resolution better than 3 fs, and a phase sensitivity of better than 3{sup o}, or a sensitivity of < 3 nm of the expansion of the particles.

59 BASIC BIOLOGICAL SCIENCES↗

Extension of the Inverse Adding-Doubling Method to the Measurement of Wavelength-Dependent Absorption and Scattering Coefficients of Biological Samples

Light interaction with biological tissue can be described using three parameters: the scattering and absorption coefficients (us and ua), as well as the anisotropy (g) which describes the directional dependence of the scattered photons. Accurately determining these optical properties for different tissue types at specific wavelengths, and simultaneously, would be beneficial for a variety of different biomedical applications. The goal of this project was to take a user-defined g-value and determine the remaining two parameters for a specified wavelength range for an integrating sphere with a collimated white light input source system. A fully automated computer program and process was developed to collect data for all wavelengths in a timely and accurate manner. LabVIEW was used to write programs to automate: raw intensity data collection from a spectrometer equipped integrating sphere, conversion of the data into a format for analysis via Scott Prahl's Inverse Adding-Doubling (IAD) C code execution, and computation of the optical properties based on the output from the IAD code. To allow data to be passed efficiently between LabVIEW and C code program modules, the two were combined into a single program (OPT 3.1). OPT 3.1 was tested using tissue mimicking phantoms and determination of the absorption and scattering coefficients showed excellent agreement with theory for wavelengths were the user inputted single g-value was sufficiently precise. Future improvements entail providing for multi-wavelength g-value entry to extend the accuracy of results to encompass the complete system multispectral range. Ultimately, the data collection process and algorithms developed through this effort will be used to study actual biological tissues for the purpose of deriving and refining models for light-tissue interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low voltage AC electroluminescence in silicon MOS capacitors

Low power silicon based light source and detector are attractive for on-chip photonic circuits given their ease of process integration. However, conventional silicon light emitting diodes emit photons with energies near the band edge where the corresponding silicon photodetectors lack responsivity. On the other hand, previously reported hot carrier electroluminescent silicon devices utilizing a reverse biased diode require high operating voltages. Here, we investigate hot carrier electroluminescence in silicon metal–oxide–semiconductor capacitors operating under transient voltage conditions. Further, during each voltage transient, large energy band bending is created at the edge of the source contact, much larger than what is achievable at a steady state. As a result, electrons and holes are injected efficiently from a single source contact into the silicon channel at the corresponding voltage transient, where they subsequently undergo impact ionization and phonon-assisted interband recombination. Notably, we show low voltage operation down to 2.8 V by using a 20 nm thick high-κ gate dielectric. We show further voltage scaling is possible by reducing the gate dielectric thickness, thus presenting a low voltage platform for silicon optoelectronic integrated circuits.

42 ENGINEERING↗

Impact of charge carrier injection on single-chain photophysics of conjugated polymers

Charges in conjugated polymer materials have a strong impact on the photophysics and their interaction with the primary excited state species has to be taken into account in understanding device properties. Here, we employ single-molecule spectroscopy to unravel the influence of charges on several photoluminescence (PL) observables. The charges are injected either stochastically by a photochemical process or deterministically in a hole-injection sandwich device configuration. We find that upon charge injection, besides a blue-shift of the PL emission and a shortening of the PL lifetime due to quenching and blocking of the lowest-energy chromophores, the non-classical photon arrival time distribution of the multichromophoric chain is modified towards a more classical distribution. Surprisingly, the fidelity of photon antibunching deteriorates upon charging, whereas one would actually expect the opposite: the number of chromophores to be reduced. A qualitative model is presented to explain the observed PL changes. The results are of interest to developing a microscopic understanding of the intrinsic charge-exciton quenching interaction in devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

p +p - electroproduction off protons in deuterium: measurements of quasi-free cross sections and kinematic probing of final state interactions

In this study, the process of pi+pi- electroproduction off protons bound in deuterium nuclei is explored. The exploration is performed through the analysis of experimental data on electron scattering off the deuteron target, collected in Hall B at Jefferson Lab with the CLAS detector. As a main result, the set of integrated and single-differential cross sections of the reaction yvp(n) -> p'(n')pi+pi- is obtained. The cross sections are extracted in the quasi-free regime, which implies that only events not affected by final state interactions are subject to selection. The measurements are performed in the kinematic region of the invariant mass W from 1.3 GeV to 1.825 GeV and photon virtuality Q2 from 0.4 GeV2 to 1 GeV2. Sufficient experimental statistics allows narrow binning, i.e. 25 MeV in W and 0.05 GeV2 in Q2, while maintaining an adequate statistical uncertainty. The extraction of quasi-free cross sections is accompanied by the kinematic probing of FSI between the reaction final hadrons and the spectator neutron in the aforementioned exclusive channel. In this probing the distributions of missing quantities are used in order to investigate the relative spread of events with FSI along the reaction phase space, trace the difference of FSI manifestations in different reaction topologies, reveal details on alterations of the hadron momentum in FSI, and isolate FSI contributions of various final hadrons. The performed examination is also capable of retrieving information on some underlying FSI mechanisms, among which the process of resonance formation in the intermediate state of pion-neutron interactions is particularly remarkable.

Skorodumina, Iuliia↗

Broadband Nonreciprocity Enabled by Strong Coupling of Magnons and Microwave Photons

Nonreciprocity of signal transmission enhances the capacity of communication channels and protects the transmission quality against possible signal instabilities, thus becoming an important component for ensuring coherent information processing. However, nonreciprocal transmission requires breaking time-reversal symmetry (TRS), which poses challenges of both practical and fundamental character that hinder progress. Here we report an alternative scheme for achieving broadband nonreciprocity using a specially engineered hybrid microwave cavity. The TRS breaking is realized via strong coherent coupling between a selected chiral mode in the microwave cavity and a single collective spin excitation (magnon) in a ferromagnetic yttrium iron garnet sphere. The nonreciprocity in transmission is observed to span nearly a 0.5-GHz frequency band, which outperforms by two orders of magnitude the previously achieved bandwidths. Our findings suggest a promising direction for robust coherent information processing in a broad range of systems in both the classical and the quantum regime.

36 MATERIALS SCIENCE↗

Effect of the wire width on the intrinsic detection efficiency of superconducting-nanowire single-photon detectors

A thorough spectral study of the intrinsic single-photon detection efficiency in superconducting TaN and NbN nanowires with different widths has been performed. The experiment shows that the cut-off of the intrinsic detection efficiency at near-infrared wavelengths is most likely controlled by the local suppression of the barrier for vortex nucleation around the absorption site. Beyond the cut-off quasi-particle diffusion in combination with spontaneous, thermally activated vortex crossing explains the detection process. For both materials, the reciprocal cut-off wavelength scales linearly with the wire width where the scaling factor agrees with the hot-spot detection model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selective engineering of cavity resonance for frequency matching in optical parametric processes

We propose to selectively engineer a single cavity resonance to achieve frequency matching for optical parametric processes in high-Q microresonators. For this purpose, we demonstrate an approach, selective mode splitting (SMS), to precisely shift a targeted cavity resonance, while leaving other cavity modes intact. We apply SMS to achieve efficient parametric generation via four-wave mixing in high-Q silicon microresonators. The proposed approach is of great potential for broad applications in integrated nonlinear photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon-induced selenium migration in TiSe 2

TiSe 2 is a member of the transition metal dichalcogenide family of layered van der Waals materials which exhibits some distinct electronic and optical properties. Here, in this work, we perform Raman spectroscopy and microscopy studies on single crystal TiSe 2 to investigate thermal and photon-induced defects associated with diffusion of selenium to the surface. Additional phonon peaks near 250 cm -1 are observed in the laser-irradiated regions that are consistent with formation of amorphous and nanocrystalline selenium on the surface. Temperature dependent studies of the threshold temperature and laser intensity necessary to initiate selenium migration to the surface show an activation barrier for the process of 1.55 eV. The impact of these results on the properties of strongly correlated electron states in TiSe 2 are discussed

36 MATERIALS SCIENCE↗

Characterization and Optimization of Skipper CCDs for the SOAR Integral Field Spectrograph

We present results from the characterization and optimization of Skipper charge-coupled devices (CCDs) for use in a focal plane prototype for the Southern Astrophysical Research Integral Field Spectrograph (SIFS). We tested eight Skipper CCDs and selected six for SIFS based on performance results. The Skipper CCDs are 6k × 1k, 15 μm pixels, thick, fully depleted, p-channel devices that have been thinned to ~250 μm, backside processed, and treated with an anti-reflective coating. We demonstrate a single-sample readout noise of <4.3 e - rms pixel -1 in all amplifiers. We optimize the readout sequence timing to achieve a readout noise of 0.5 e - rms pixel -1 after 74 non-destructive measurements, which can be accomplished in a region covering 5% of the detector area in a readout time of <4 minutes. We demonstrate single-photon-counting in all 24 amplifiers (four amplifiers per detector) with a readnoise of σ N ~ 0.18 e - rms pixel -1 after N samp = 400 samples, and we constrain the degree of nonlinearity to be ≲1% at low signal levels (0 e - to 50 e - ). Clock-induced charge (CIC) remains an important issue when the Skipper CCD is configured to provide a large full-well capacity. We achieve a CIC rate of <1.45 × 10 -3 e - pixel -1 frame -1 for a full-well capacity of ~900 e - , which increases to a CIC rate of ~3 e - pixel -1 frame -1 for full-well capacities ~40,000-65,000 e - . We also perform conventional CCD characterization measurements such as charge transfer inefficiency (3.44 × 10 -7 on average), dark current (~2 × 10 -4 e - pixel -1 s -1 ), photon transfer curves, cosmetic defects (<0.45% “bad” pixels), and charge diffusion (point-spread function < 7.5 μm) to verify that these properties are consistent with expectations from conventional p-channel CCDs used for astronomy. Furthermore, we provide the first measurements of the brighter-fatter effect and absolute quantum efficiency (≳80% between 450 and 980 nm; ≳90% between 600 and 900 nm) using Skipper CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasmonic pathway to hybrid nanomaterials through energy transfer

Plasmon-induced resonance energy transfer (PIRET) is a promising approach for plasmonic photocatalysis and energy conversion, but challenges include elucidating the mechanism and maximizing its efficiency, both of which are hampered by competing processes. Another challenge is demonstrating that PIRET can photoinitiate reactions that follow efficient pathways compared to bulk processes. We report a plasmon-induced route to plasmonic-polymer hybrid nanomaterials using in operando single-particle spectroelectrochemistry. An energy transfer efficiency of 40% is achievable when the spectral overlap between gold nanorod scattering and polymer absorption is maximized. We also show that PIRET-initiated polymerization proceeds through a different mechanism than bulk polymerization, supported by spectroscopic evidence and density functional theory calculations, highlighting efficient energy cascading from photon to plasmon to exciton and, lastly, to unconventional light-initiated chemistry.

Oh, Hyuncheol [University of Illinois Urbana-Champ↗

Role of water vapour in the absorption of nanosecond 266-nm laser pulses by atmospheric air

The absorption of the Nd : YAG fourth harmonic in air and binary mixtures of water vapour with nitrogen and oxygen at atmospheric pressure has been measured as a function of pulse energy (peak intensity). The mixtures obtained by adding equal amounts of water vapour to dry nitrogen and oxygen have been found to differ significantly in absorption. Preliminary quantitative data have been obtained for two- and three-photon absorption cross sections of water and oxygen molecules: σ{sup (2)}(H{sub 2}O) = (4 ± 1) ± 10{sup –49} cm{sup 4} s and σ{sup (3)}(O{sub 2}) = (5.6 ± 1.4) ± 10{sup –78} cm{sup 6} s{sup 2}. The absorption of 266-nm pulses with peak intensities from 0.05 to 2 GW cm{sup –2} in the near-surface atmosphere has been shown to be determined by two-photon absorption in water vapour and three-photon absorption in oxygen. In moist air containing 1 % water vapour, the absorption coefficient for 266-nm laser pulses exceeds that in dry air by four to five times. There is no absorption in nitrogen. We have developed a technique for photoacoustic measurements of multiphoton absorption cross sections in single-component gases and gas mixtures. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Invited Review Article: Pump-probe microscopy

Multiphoton microscopy has rapidly gained popularity in biomedical imaging and materials science because of its ability to provide three-dimensional images at high spatial and temporal resolution even in optically scattering environments. Currently the majority of commercial and home-built devices are based on two-photon fluorescence and harmonic generation contrast. These two contrast mechanisms are relatively easy to measure but can access only a limited range of endogenous targets. Recent developments in fast laser pulse generation, pulse shaping, and detection technology have made accessible a wide range of optical contrasts that utilize multiple pulses of different colors. Molecular excitation with multiple pulses offers a large number of adjustable parameters. For example, in two-pulse pump-probe microscopy, one can vary the wavelength of each excitation pulse, the detection wavelength, the timing between the excitation pulses, and the detection gating window after excitation. Such a large parameter space can provide much greater molecular specificity than existing single-color techniques and allow for structural and functional imaging without the need for exogenous dyes and labels, which might interfere with the system under study. In this review, we provide a tutorial overview, covering principles of pump-probe microscopy and experimental setup, challenges associated with signal detection and data processing, and an overview of applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗