Search NASA⌕ Search

SEARCH · Search NASA

Results for “slicing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

SU-G-IeP4-02: Application of Changs Attenuation Correction Technique for SPECT Partial Angle Acquisition of Jaszczak Phantom

Purpose: Chang’s mathematical formulation is a common method of attenuation correction applied on reconstructed Jaszczak phantom images. Though Chang’s attenuation correction method has been used for 360° angle acquisition, its applicability for 180° angle acquisition remains a question with one vendor’s camera software producing artifacts. The objective of this work is to ensure that Chang’s attenuation correction technique can be applied for reconstructed Jaszczak phantom images acquired in both 360° and 180° mode. Methods: The Jaszczak phantom filled with 20 mCi of diluted Tc-99m was placed on the patient table of Siemens e.cam™ (n = 2) and Siemens Symbia™ (n = 1) dual head gamma cameras centered both in lateral and axial directions. A total of 3 scans were done at 180° and 2 scans at 360° orbit acquisition modes. Thirty two million counts were acquired for both modes. Reconstruction of the projection data was performed using filtered back projection smoothed with pre reconstruction Butterworth filter (order: 6, cutoff: 0.55). Reconstructed transaxial slices were attenuation corrected by Chang’s attenuation correction technique as implemented in the camera software. Corrections were also done using a modified technique where photon path lengths for all possible attenuation paths through a pixel in the image space were added to estimate the corresponding attenuation factor. The inverse of the attenuation factor was utilized to correct the attenuated pixel counts. Results: Comparable uniformity and noise were observed for 360° acquired phantom images attenuation corrected by the vendor technique (28.3% and 7.9%) and the proposed technique (26.8% and 8.4%). The difference in uniformity for 180° acquisition between the proposed technique (22.6% and 6.8%) and the vendor technique (57.6% and 30.1%) was more substantial. Conclusion: Assessment of attenuation correction performance by phantom uniformity analysis illustrated improved uniformity with the proposed algorithm compared to the camera software.

60 APPLIED LIFE SCIENCES↗

Use of High-Frequency Jet Ventilation for Percutaneous Tumor Ablation

Purpose: To report feasibility and potential benefits of high-frequency jet ventilation (HFJV) in tumor ablations techniques in liver, kidney, and lung lesions. Methods: This prospective study included 51 patients (14 women, mean age 66 years) bearing 66 tumors (56 hepatic, 5 pulmonary, 5 renal tumors) with a median size of 16 ± 8.7 mm, referred for tumor ablation in an intention-to-treat fashion before preoperative anesthesiology visit. Cancellation and complications of HFJV were prospectively recorded. Anesthesia and procedure duration, as well as mean CO{sub 2} capnea, were recorded. When computed tomography guidance was used, 3D spacial coordinates of an anatomical target <2 mm in diameter on 8 slabs of 4 slices of 3.75-mm slice thickness were registered. Results: HFJV was used in 41 of 51 patients. Of the ten patients who were not candidate for HFJV, two patients had contraindication to HFJV (severe COPD), three had lesions invisible under HFJV requiring deep inspiration apnea for tumor targeting, and five patients could not have HFJV because of unavailability of a trained anesthetic team. No specific complication or hypercapnia related to HFJV were observed despite a mean anesthetic duration of 2 h and ventilation performed in procubitus (n = 4) or lateral decubitus (n = 6). Measured internal target movement was 0.3 mm in x- and y-axis and below the slice thickness of 3.75 mm in the z-axis in 11 patients. Conclusions: HFJV is feasible in 80 % of patients allowing for near immobility of internal organs during liver, kidney, and lung tumor ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast Tomography: A Study Of Image Quality

We present tomographic slices of fast X-ray computed microtomography, focusing on one hand on the comparison of scans with identical scan time but varying experimental settings, on the other hand on comparing scans with total scan times that are two orders of magnitude apart. We show that streaks in the Fourier-space of the transformed images appear when the number of projections is reduced. These streaks exhibit spacing by the same angle as the one that is covered by the sample during the exposure time of one projection. Further a method for the estimation of information loss in fast scans is presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-78: Improving Prostatic Delineation Using Dual-Energy CT

Purpose: Visual prostatic definition is difficult using conventional CT. This is because the prostate is surrounded closely with tissue of similar electron density. Definition is further hindered when the region contains high-Z material (such as fiducial markers). Dual-energy CT (DECT) is a technique where images are rendered using two tube voltages during a single scan session. This study evaluates DECT as a means of improving prostatic volume delineation for radiation oncology. Methods: The patients were scanned using a Definition AS20 (Siemens Healthcare, Malvern, PA). This device uses a single-tube configuration, where two scans of differing energies are performed in serial. The scans are acquired with tube voltage of 80kVp and 140kVp. Following acquisition, these scan data were used to generate effective monoenergetic scans ranging from 40keV to 190keV. In the current study, the data were presented to observers using a novel program, which allows real-time adjustment of window, level, and effective keV; all while scrolling through volumetric slices. Three patients were scanned, each with a different high-contrast material in or around the prostate: I-125 seeds, gold fiducial markers, and prostatic calcifications. These images are compared to a weighted average of the 80kVp and 140kVP scans, which yield a scan similar to that of a 120 kVp scan, which is a common tube voltage in radiation oncology. Results: Prostatic definition improved in each case. Differentiation of soft tissue from surrounding adipose improved with lower keV, while higher keV provided a reduction of high-z artifacts. Furthermore, the dynamic adjustment of the keV allowed observers to better recognize regions of differing tissue composition within this relatively homogeneous area. Conclusion: By simultaneously providing the observer with the benefits of high-energy images and low-energy images, and allowing adjustment in real-time, improved imaging in highly homogeneous regions such as the male pelvis is achievable.

60 APPLIED LIFE SCIENCES↗

Magnetic Resonance Imaging (MRI) of skeletal muscles in astronauts after 9 days of space flight

Skylab data indicated that prolonged exposure of human subjects to microgravity environment causes significant muscle atrophy accompanied by reduced muscle strength and fatigue resistance. The objective of this study was to determine decrements in muscle size, if any, in the soleus and gastrocnemius muscles of male and female astronauts after 9 days of space flight. Methods: Eight astronauts, one female and seven male, between the ages of 31 and 59 years 59-84 kg in body weight were examined by MRI 2-3 times preflight within 16 days before launch, and 2 days, (n=6) and seven days (n=3) after landing. The right leg muscles (gastroc-soleus) were imaged with a lower extremity coil in magnets operating at 1.0 or 1.5 Tsela. The imaging protocol consisted of spin echo with a Tr of 0.70 - 1.5 sec. Thirty to forty 3-5 mm thick slices were acquired in 256 x 128 or 256 x 256 matrices. Acquisition time lasted 20-40 minutes. Multiple slices were measured by computerized planimetry. Results: Compared to the preflight, the cross-sectoral areas (CSA) of the soleus, gastrocnemius, and the leg, at 2 days after landing were reduced (at least p less than 0.05) 8.9 percent, 13.2 percent, and 9.5 percent respectively. The soleus and the leg of three astronauts evaluated at 7 days postflight did not show full recovery compared to the preflight values. Conclusions: It is concluded that l9-days of space flight may cause significant decreases in CSA of the leg muscles. The factors responsible for this loss need further determination.

Jaweed, M.↗

Automated Recognition of 3D Features in GPIR Images

A method of automated recognition of three-dimensional (3D) features in images generated by ground-penetrating imaging radar (GPIR) is undergoing development. GPIR 3D images can be analyzed to detect and identify such subsurface features as pipes and other utility conduits. Until now, much of the analysis of GPIR images has been performed manually by expert operators who must visually identify and track each feature. The present method is intended to satisfy a need for more efficient and accurate analysis by means of algorithms that can automatically identify and track subsurface features, with minimal supervision by human operators. In this method, data from multiple sources (for example, data on different features extracted by different algorithms) are fused together for identifying subsurface objects. The algorithms of this method can be classified in several different ways. In one classification, the algorithms fall into three classes: (1) image-processing algorithms, (2) feature- extraction algorithms, and (3) a multiaxis data-fusion/pattern-recognition algorithm that includes a combination of machine-learning, pattern-recognition, and object-linking algorithms. The image-processing class includes preprocessing algorithms for reducing noise and enhancing target features for pattern recognition. The feature-extraction algorithms operate on preprocessed data to extract such specific features in images as two-dimensional (2D) slices of a pipe. Then the multiaxis data-fusion/ pattern-recognition algorithm identifies, classifies, and reconstructs 3D objects from the extracted features. In this process, multiple 2D features extracted by use of different algorithms and representing views along different directions are used to identify and reconstruct 3D objects. In object linking, which is an essential part of this process, features identified in successive 2D slices and located within a threshold radius of identical features in adjacent slices are linked in a directed-graph data structure. Relative to past approaches, this multiaxis approach offers the advantages of more reliable detections, better discrimination of objects, and provision of redundant information, which can be helpful in filling gaps in feature recognition by one of the component algorithms. The image-processing class also includes postprocessing algorithms that enhance identified features to prepare them for further scrutiny by human analysts (see figure). Enhancement of images as a postprocessing step is a significant departure from traditional practice, in which enhancement of images is a preprocessing step.

Park, Han↗

CFD SIMULATION OF PROPOSED VALIDATION DATA FOR A FLOW PROBLEM RECONFIGURED TO ELIMINATE AN UNDESIRABLE FLOW INSTABILITY

The U. S. Department of Energy (DOE) is supporting the development of a next generation nuclear plant (NGNP), which will be based on a very high temperature reactor (VHTR) design. The VHTR is a single-phase helium-cooled reactor wherein the helium will be heated initially to 750 °C and later to temperatures approaching 1000 °C. The high temperatures are desired to increase reactor efficiency and to provide a heat source for the manufacture of hydrogen and other applications. While computational fluid dynamics (CFD) has not been used in the past to design or license nuclear reactors in the U. S., it is expected that CFD will be used in the design and safety analysis of forthcoming designs. This is partly because of the maturity of CFD and partly because detailed information is desired of the flow and heat transfer inside the reactor to avoid hot spots and other conditions that might compromise reactor safety. Numerical computations of turbulent flow should be validated against experimental data for flow conditions that contain some or all of the physics expected in the thermal fluid machinery of interest. To this end, a scaled model of a narrow slice of the lower plenum of the prismatic VHTR was constructed and installed in the Idaho National Laboratory’s (INL) matched index of refraction (MIR) test facility and data were taken. The data were then studied and compared to CFD calculations to help determine their suitability for validation data. One of the main findings was that the inlet data, which were measured and controlled by calibrated mass flow rotameters and were also measured using detailed stereo particle image velocimetry (PIV) showed considerable discrepancies in mass flow rate between the two methods. The other finding was that a randomly unstable recirculation zone occurs in the flow. This instability has a very significant effect on the flow field in the vicinity of the inlet jets. Because its time scale is long and because it is apparently a random instability, it was deemed undesirable for a validation data set. It was predicted using CFD that by eliminating the first of the four jets, the recirculation zone could be stabilized. The present paper reports detailed results for the three-jet case with comparisons to the four-jet data inasmuch as three-jet data are still unavailable. Hence, the present simulations are true or blind predictions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

National Cancer Institute Think-Tank Meeting Report on Proteomic Cartography and Biomarkers at the Single-Cell Level: Interrogation of Premalignant Lesions

A Think-Tank Meeting was convened by the National Cancer Institute (NCI) to solicit experts’ opinion on the development and application of multi-omic single-cell analyses, and especially single-cell proteomics, to improve the development of a new generation of biomarkers for cancer risk, early detection, diagnosis, prognosis as well as to discuss the discovery of new targets for prevention and therapy. It is anticipated that such markers and targets will be based on cellular, subcellular, molecular and functional aberrations within the lesion and within individual cells. Additionally, single-cell proteomic data will be essential for the establishment of new tools that with searchable and scalable features that include spatial and temporal cartographies of premalignant and malignant lesions. Challenges and potential solutions that were discussed included: • The best way/s to analyze single-cells from fresh and preserved tissue • Detection and analysis of secreted molecules and from single cells, especially from a tissue slice • Detection of new, previously undocumented cell type/s in the premalignant and early stage cancer tissue microenvironment • Multi-omic integration of data to support and inform proteomic measurements • Subcellular organelles – identifying abnormal structure, function, distribution and location within individual premalignant and malignant cells • How to improve the dynamic range of single-cell proteomic measurements for discovery of differentially expressed proteins and their post translational modifications (PTM) • The depth of coverage measured concurrently using single-cell techniques • Quantitation - absolute or semiquantitative? • Single methodology or multiplexed combinations? • Application of analytical methods for identification of biologically significant subsets • Data visualization of N-dimensional datasets • How to construct intercellular signaling networks in individual cells within premalignant tumor microenvironments (TME) • Associations between intrinsic cellular processes and extrinsic stimuli • How to predict cellular responses to stress inducing stimuli • Identification of new markers for prediction of progression from precursor, benign and localized lesions to invasive cancer, based on spatial and temporal changes within individual cells • Identification of new targets for immunoprevention or immunotherapy – identification of neoantigens and surfactome of individual cells within a lesion

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGR sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3.2±1.6mm in patients with no endorectal coil, 2.3±0.8mm in patients with 30cc-PFC-filled endorectal-coil and 5.0±1.8mm in patients with 50cc-PFC-filled endorectal-coil. Conclusion: An MR protocol to visualize positive-contrast Sirius markers to assist in the identification of negative-contrast seeds was demonstrated. S Frank is a co-founder of C4 Imaging LLC, the manufacturer of the MRI markers.

60 APPLIED LIFE SCIENCES↗

Investigation of Vapor Cooling Enhancements for Applications on Large Cryogenic Systems

The need to demonstrate and evaluate the effectiveness of heat interception methods for use on a relevant cryogenic propulsion stage at a system level has been identified. Evolvable Cryogenics (eCryo) Structural Heat Intercept, Insulation and Vibration Evaluation Rig (SHIIVER) will be designed with vehicle specific geometries (SLS Exploration Upper Stage (EUS) as guidance) and will be subjected to simulated space environments. One method of reducing structure-born heat leak being investigated utilizes vapor-based heat interception. Vapor-based heat interception could potentially reduce heat leak into liquid hydrogen propulsion tanks, increasing potential mission length or payload capability. Due to the high number of unknowns associated with the heat transfer mechanism and integration of vapor-based heat interception on a realistic large-scale skirt design, a sub-scale investigation was developed. The sub-project effort is known as the Small-scale Laboratory Investigation of Cooling Enhancements (SLICE). The SLICE aims to study, design, and test sub-scale multiple attachments and flow configuration concepts for vapor-based heat interception of structural skirts. SLICE will focus on understanding the efficiency of the heat transfer mechanism to the boil-off hydrogen vapor by varying the fluid network designs and configurations. Various analyses were completed in MATLAB, Excel VBA, and COMSOL Multiphysics to understand the optimum flow pattern for heat transfer and fluid dynamics. Results from these analyses were used to design and fabricate test article subsections of a large forward skirt with vapor cooling applied. The SLICE testing is currently being performed to collect thermal mechanical performance data on multiple skirt heat removal designs while varying inlet vapor conditions necessary to intercept a specified amount of heat for a given system. Initial results suggest that applying vapor-cooling provides a 50 heat reduction in conductive heat transmission along the skirt to the tank. The information obtained by SLICE will be used by the SHIIVER engineering team to design and implement vapor-based heat removal technology into the SHIIVER forward skirt hardware design.

small scale testing↗

SU-E-T-208: Comparison of MR Image Quality of Various Brachytherapy Applicators for Cervical Cancer

Purpose: To compare the quality of Magnetic Resonance (MR) images of a recently-proposed novel direction-modulated brachytherapy (DMBT) tandem applicator against two conventional clinical applicators, using the current MRI clinical protocol. Methods: Three tandem applicators were compared: (1) tungsten-based DMBT applicator, (2) conventional plastic applicator and (3) conventional stainless steel applicator. Physical dimensions were 5.4, 3.8 and 3.2 for tandems (1), (2) and (3), respectively. Each applicator was placed in the same water-phantom and independently scanned using the same parameters and coil settings on a 1.5 T 450w GE scanner. Images were acquired using T2-weighted turbo-spin-echo (TSE) with 8-channel body coil. Acquisition parameters were TR/TE =7000/108 ms; acquisition matrix = 320 x 256; 30 slices with 4 mm thickness and 0.5 gap; pixel bandwidth = 122 Hz and voxel size = 0.5 x 0.625 mm2 and number of excitations (NEX) = 4. Multiple acquisitions were obtained in para-sagittal and para-axial views (with respect to the tandem axis) for each applicator. Diameters of the tandem were measured at multiple angles and multiple locations and compared to the physical dimensions of the corresponding tandems. Results: Minimal susceptibility artifact was observed with the DMBT and the plastic tandems. The stainless steel tandem produced significantly larger artifact than the first two tandems. The average diameter of the DMBT applicator measured 5.94 ± 0.3 mm. The average diameter of the plastic tandem measured 3.9 ± 0.1 mm. The maximum extent of artifact was 1.5 mm and 0.7 mm for DMBT and plastic tandems, respectively. The susceptibility artifact induced by the stainless steel tandem prevented the measurement of its diameter, and the edges of the tandem could not be identified in any acquisition. Conclusion: This work demonstrated that the plastic and the tungsten-based DMBT tandem applicators are both suitable for MRI-guided brachytherapy of cervical cancer.

60 APPLIED LIFE SCIENCES↗

Geometric and Dosimetric Approach to Determine Probability of Late Cardiac Mortality in Left Tangential Breast Irradiation: Comparison Between Wedged Beams and Field-in-Field Technique

Purpose: To evaluate the probability of late cardiac mortality resulting from left breast irradiation planned with tangential fields and to compare this probability between the wedged beam and field-in-field (FIF) techniques and to investigate whether some geometric/dosimetric indicators can be determined to estimate the cardiac mortality probability before treatment begins. Methods and Materials: For 30 patients, differential dose-volume histograms were calculated for the wedged beam and FIF plans, and the corresponding cardiac mortality probabilities were determined using the relative seriality model. As a comparative index of the dose distribution uniformity, the planning target volume (PTV) percentages involved in 97-103% of prescribed dose were determined for the two techniques. Three geometric parameters were measured for each patient: the maximal length, indicates how much the heart contours were displaced toward the PTV, the angle subtended at the center of the computed tomography slice by the PTV contour, and the thorax width/thickness ratio. Results: Evaluating the differential dose-volume histograms showed that the gain in uniformity between the two techniques was about 1.5. With the FIF technique, the mean dose sparing for the heart, the left anterior descending coronary artery, and the lung was 15% (2.5 Gy vs. 2.2 Gy), 21% (11.3 Gy vs. 9.0 Gy), and 42% (8.0 Gy vs. 4.6 Gy) respectively, compared with the wedged beam technique. Also, the cardiac mortality probability decreased by 40% (from 0.9% to 0.5%). Three geometric parameters, the maximal length, angle subtended at the center of the computed tomography slice by the PTV contour, and thorax width/thickness ratio, were the determining factors (p = .06 for FIF, and p = .10 for wedged beam) for evaluating the cardiac mortality probability. Conclusion: The FIF technique seemed to yield a lower cardiac mortality probability than the conventional wedged beam technique. However, although our study demonstrated that FIF technique improved the dose coverage of the PTV, the restricted number of patients enrolled and the short follow-up did not allow us to evaluate and compare the breast cancer survival rates of the patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-642: Sub Millimeter Accurate Setup of More Than Three Vertebrae in Spinal SBRT with 6D Couch

Purpose: To assess the initial setup accuracy in treating more than 3 vertebral body levels in spinal SBRT using a 6D couch. Methods: We retrospectively analyzed last 20 spinal SBRT patients (4 cervical, 9 thoracic, 7 lumbar/sacrum) treated in our clinic. These patients in customized immobilization device were treated in 1 or 3 fractions. Initial setup used ExacTrac and Brainlab 6D couch to align target within 1 mm and 1 degree, following by a cone beam CT (CBCT) for verification. Our current standard practice allows treating a maximum of three continuous vertebrae. Here we assess the possibility to achieve sub millimeter setup accuracy for more than three vertebrae by examining the residual error in every slice of CBCT. The CBCT had a range of 17.5 cm, which covered 5 to 9 continuous vertebrae depending on the patient and target location. In the study, CBCT from the 1st fraction treatment was rigidly registered with the planning CT in Pinnacle. The residual setup error of a vertebra was determined by expanding the vertebra contour on the planning CT to be large enough to enclose the corresponding vertebra on CBCT. The margin of the expansion was considered as setup error. Results: Out of the 20 patients analyzed, initial setup accuracy can be achieved within 1 mm for a span of 5 or more vertebrae starting from T2 vertebra to inferior vertebra levels. 2 cervical and 2 upper thoracic patients showed the cervical spine was difficult to achieve sub millimeter accuracy for multi levels without a customized immobilization headrest. Conclusion: If the curvature of spinal columns can be reproduced in customized immobilization device during treatment as simulation, multiple continuous vertebrae can be setup within 1 mm with the use of a 6D couch.

60 APPLIED LIFE SCIENCES↗

Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods

Purpose: For nonlinear iterative image reconstructions (IR), the computed tomography (CT) noise and resolution properties can depend on the specific imaging conditions, such as lesion contrast and image noise level. Therefore, it is imperative to develop a reliable method to measure the noise and resolution properties under clinically relevant conditions. This study aimed to develop a robust methodology to measure the three-dimensional CT noise and resolution properties under such conditions and to provide guidelines to achieve desirable levels of accuracy and precision. Methods: The methodology was developed based on a previously reported CT image quality phantom. In this methodology, CT noise properties are measured in the uniform region of the phantom in terms of a task-based 3D noise-power spectrum (NPS{sub task}). The in-plane resolution properties are measured in terms of the task transfer function (TTF) by applying a radial edge technique to the rod inserts in the phantom. The z-direction resolution properties are measured from a supplemental phantom, also in terms of the TTF. To account for the possible nonlinearity of IR, the NPS{sub task} is measured with respect to the noise magnitude, and the TTF with respect to noise magnitude and edge contrast. To determine the accuracy and precision of the methodology, images of known noise and resolution properties were simulated. The NPS{sub task} and TTF were measured on the simulated images and compared to the truth, with criteria established to achieve NPS{sub task} and TTF measurements with <10% error. To demonstrate the utility of this methodology, measurements were performed on a commercial CT system using five dose levels, two slice thicknesses, and three reconstruction algorithms (filtered backprojection, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 5, SAFIRE5). Results: To achieve NPS{sub task} measurements with <10% error, the number of regions of interest needed to be greater than 65. To achieve TTF measurements with <10% error, the contrast-to-noise ratio of the edge needed to be ≥15, achievable by averaging multiple slices across the same edge. The NPS{sub task} measured on a commercial CT system showed IR's reduced noise (IRIS, 30% and SAFIRE5, 55%) and “waxier” texture (peak frequencies: FBP, 0.25 mm{sup −1}; IRIS, 0.23 mm{sup −1}; and SAFIRE5, 0.16 mm{sup −1}). The TTF measured within the axial plane showed improved in-plane resolution with SAFIRE5 at the TTF 50% frequency, f{sub 50} (FBP, 0.36–0.41 mm{sup −1}; SAFIRE5, 0.37–0.46 mm{sup −1}). The TTF measured along the axial direction showed improved z-direction resolution with thinner slice thickness (f{sub 50}: 0.6 mm, 0.35–0.79 mm{sup −1}; 1.5 mm, 0.22–0.3 mm{sup −1}) and with SAFIRE5 (f{sub 50}: FBP, 0.35–0.52 mm{sup −1}; SAFIRE5, 0.42–0.79 mm{sup −1}). Both in-plane and z-direction resolution of SAFIRE5 showed strong dependency on contrast, reflecting SAFIRE5's nonlinearity. Conclusions: A methodology was developed to measure three-dimensional CT noise and resolution properties for iterative reconstruction, especially at challenging measurement conditions with low contrast and high image noise. The methodology also demonstrated its utility for evaluating commercial CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Macroscopic Pathology Measurements With Magnetic Resonance Imaging and Assessment of Microscopic Pathology Extension for Colorectal Liver Metastases

Purpose: To compare pathology macroscopic tumor dimensions with magnetic resonance imaging (MRI) measurements and to establish the microscopic tumor extension of colorectal liver metastases. Methods and Materials: In a prospective pilot study we included patients with colorectal liver metastases planned for surgery and eligible for MRI. A liver MRI was performed within 48 hours before surgery. Directly after surgery, an MRI of the specimen was acquired to measure the degree of tumor shrinkage. The specimen was fixed in formalin for 48 hours, and another MRI was performed to assess the specimen/tumor shrinkage. All MRI sequences were imported into our radiotherapy treatment planning system, where the tumor and the specimen were delineated. For the macroscopic pathology analyses, photographs of the sliced specimens were used to delineate and reconstruct the tumor and the specimen volumes. Microscopic pathology analyses were conducted to assess the infiltration depth of tumor cell nests. Results: Between February 2009 and January 2010 we included 13 patients for analysis with 21 colorectal liver metastases. Specimen and tumor shrinkage after resection and fixation was negligible. The best tumor volume correlations between MRI and pathology were found for T1-weighted (w) echo gradient sequence (r{sub s} = 0.99, slope = 1.06), and the T2-w fast spin echo (FSE) single-shot sequence (r{sub s} = 0.99, slope = 1.08), followed by the T2-w FSE fat saturation sequence (r{sub s} = 0.99, slope = 1.23), and the T1-w gadolinium-enhanced sequence (r{sub s} = 0.98, slope = 1.24). We observed 39 tumor cell nests beyond the tumor border in 12 metastases. Microscopic extension was found between 0.2 and 10 mm from the main tumor, with 90% of the cases within 6 mm. Conclusions: MRI tumor dimensions showed a good agreement with the macroscopic pathology suggesting that MRI can be used for accurate tumor delineation. However, microscopic extensions found beyond the tumor border indicate that caution is needed in selecting appropriate tumor margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanisms of deterioration of nutrients phase 1

Experimental methods are studied by which freeze-dried foods of improved quality are produced. Considered are: (1) Factors effecting the loss of butanol from frozen aqueous food solutions during storage; (2) a freeze-drying microscope system for observing solidification processes in organic mixtures and aqueous inorganic salt solutions; (3) browning of high quality freeze-dried foods with minimal organoleptic and nutritional detoriation; (4) retention of PVP-n-propanol in freeze-dried food models; and (5) effects of freezing rate and sucrose immersion on taste and texture of freeze-dried apple slices.

Karel, M.↗

Investigation of cloud properties and atmospheric stability with MODIS

The work accomplished with the MAS (MODIS Airborne Simulator) during the TOGA-COARE (Tropical Ocean Global Atmosphere - Coupled Ocean Atmosphere Response Experiment) from January through June 1993 included cloud investigations with longwave CO2 channels (out to 13.9 microns) that reconfigured spectral channels. The comparison data was used with HIRS (high resolution Infrared Radiation Sounder) data from FIRE (First ISSCP Regional Experiment), CEPEX, and SCAR (Smoke Clouds, Aerosol and Radiation) data for the development of a two layer cloud CO2 slicing algorithm and the development of multi-spectral cloud detection algorithms (specifically tri-spectral) for cloud identification. Regarding the latter, a clustering analysis was added to improve cloud identification within the scatter diagram of tri-spectral (8, 11, and 12 microns) brightness temperatures. Via the regressions of the 8 - 11 and the 11 - 12 micron brightness temperature differences versus precipitable water, the problem of clear sky identification in the scatter diagram was further addressed. Comparison of the tri-spectral technique and visible channel reflectance ratioing indicate the tri-spectral infrared method distinguishes cloud phase more consistently in mixed cloud scenes rather than single phase cloud scenes where visible ratioing performs best.

Menzel, Paul↗

Compensator models for fluence field modulated computed tomography

Purpose: Fluence field modulated computed tomography (FFMCT) presents a novel approach for acquiring CT images, whereby a patient model guides dynamically changing fluence patterns in an attempt to achieve task-based, user-prescribed, regional variations in image quality, while also controlling dose to the patient. This work aims to compare the relative effectiveness of FFMCT applied to different thoracic imaging tasks (routine diagnostic CT, lung cancer screening, and cardiac CT) when the modulator is subject to limiting constraints, such as might be present in realistic implementations.Methods: An image quality plan was defined for a simulated anthropomorphic chest slice, including regions of high and low image quality, for each of the thoracic imaging tasks. Modulated fluence patterns were generated using a simulated annealing optimization script, which attempts to achieve the image quality plan under a global dosimetric constraint. Optimization was repeated under different types of modulation constraints (e.g., fixed or gantry angle dependent patterns, continuous or comprised of discrete apertures) with the most limiting case being a fixed conventional bowtie filter. For each thoracic imaging task, an image quality map (IQM{sub sd}) representing the regionally varying standard deviation is predicted for each modulation method and compared to the prescribed image quality plan as well as against results from uniform fluence fields. Relative integral dose measures were also compared.Results: Each IQM{sub sd} resulting from FFMCT showed improved agreement with planned objectives compared to those from uniform fluence fields for all cases. Dynamically changing modulation patterns yielded better uniformity, improved image quality, and lower dose compared to fixed filter patterns with optimized tube current. For the latter fixed filter cases, the optimal choice of tube current modulation was found to depend heavily on the task. Average integral dose reduction compared to a uniform fluence field ranged from 10% using a bowtie filter to 40% or greater using an idealized modulator.Conclusions: The results support that FFMCT may achieve regionally varying image quality distributions in good agreement with user-prescribed values, while limiting dose. The imposition of constraints inhibits dose reduction capacity and agreement with image quality plans but still yields significant improvement over what is afforded by conventional dose minimization techniques. These results suggest that FFMCT can be implemented effectively even when the modulator has limited modulation capabilities.

61 RADIATION PROTECTION AND DOSIMETRY↗