Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Active Measurement of Plasma Parameters in Over-Dense MFE Reactor Plasma Using High Frequency Beat-Wave Resonantly Generated Thermal Bernstein Waves

UC Davis was funded to explore the combination of beat-wave excitation and laser scattering to make completely non-invasive determination of local plasma conditions. This involves the use of two high frequency mm-wave sources of differing frequencies (the pump waves) to excite plasma waves at the difference of the frequencies, which is known as the beat frequency. The difference frequency or the frequency of the beat wave is chosen so that we produce plasma waves whose fluctuating electron density is a sensitive function of plasma parameters at the location where the source waves overlap. This fluctuation can be detected from outside the plasma, by measuring the deflection of a probe beam directed at the overlap region between the two pump waves (i.e., collective scattering). This work is an extension of mm-wave frequencies of a 10 GHz beat-wave experiment conducted on the DDT toroidal device (see Fig. 1) in a magnetized plasma where the excited Langmuir wave is replaced by the magnetized upper hybrid wave. Here, two high power (> 1 kW) ~94 GHz pump sources will be employed to match the upper hybrid resonance. The primary envisioned experiment is to drive the electron Bernstein wave (EBW) in the interior of a magnetized plasma. The EBW is a hot-plasma electrostatic wave, which cannot propagate in vacuum. Roots of the EBW dispersion relation occur at frequencies slightly higher than harmonics of the electron cyclotron frequency. Use of the EBW has particular advantages for measuring plasma magnetic field in plasmas with relatively high density and low magnetic field, as is the case in spherical tokamaks. This is the “over dense” condition of future efficient high beta magnetic confinement fusion reactors such as the spherical tokamak (STs). The overarching goal of the proposed project is to demonstrate beat wave EBW excitation in low density and temperature parameters that are directly scalable to over-dense spherical tokamaks such as NSTX or MAST, where measurement of magnetic field by electron cyclotron emission (ECE) is experimentally complex, and requires models of plasma profiles in order to interpret results. In such experiments, availability of point measurements of magnetic field strength provided by a beat-wave diagnostic would serve as a powerful independent check on the ECE results, serving to validate the assumed profiles and wave-propagation models used. The first step was to assemble/modify the target chamber in which the beat-wave plasma experiments will take place. Here, the target chamber of the CTIX compact-toroid (spheromak) injector was chosen. At the time that the proposal was submitted, the aim was to conduct the experiments in the CTIX experimental facilities located at the Livermore campus of UC Davis using microwave/mm-wave equipment brought from the main campus., However, by the time DoE funds for this project were awarded, the CTIX experimental facilities located at the Livermore campus of UC Davis were in the process of being shut down due to the closure of the Livermore campus by Lawrence Livermore National Laboratory (LLNL). Consequently, the equipment needed for this project was crated up and shipped from Livermore to Davis as part of the laboratory shutdown after space on campus was secured and College of Engineering approval secured. Once it arrived in Davis on December 20, 2018, work on the project began in earnest with the initial efforts directed toward developing a new plasma target source. Because of the shutdown of the CTIX facility, the scope of the project thus had to be reduced due to the abbreviated amount of time allocated to the project once the shutdown/move had been completed. Chamber modifications have been completed, including the fabrication and installation of a 38 GHz interferometer, as described in Sec. 3. The thermionic plasma source has been tested and characterized. The magnetic field required for the EBW experiments will be generated by permanent magnets mounted on plates positioned above and below the chamber. Magnetic simulations have been performed, and show that a 3-ring magnet arrangement on each plate, with a plate separation of 50 cm, is required to achieve the ~100 G uniform magnetic field in the interaction region that we feel is necessary to ensure good EBW coupling. We proved unable to successfully revive either of Prof. Luhmann’s two high power (≥20 kW) 94 GHz millimeter-wave sources after their extended time in storage and decided to postpone further efforts and concentrate on slightly lower power sources. Consequently, we were successful in reviving a ~2 kW extended klystron amplifier (EIK), which together with a ~2 kW extended interaction oscillator (EIO) will provide the two pump sources required for the project. Safe operation of the EIO requires extensive modifications to one of Prof. Luhmann’s pulse modulators - these modulator modifications are ongoing, which has unfortunately delayed the planned beat-wave experiments. Details of this work are provided in Sec. 3. Even though project funding has now ended, we still plan to proceed to complete the EIO pulse modulator modifications, install the two ~94 GHz pump wave sources on the target chamber, and conduct unmagnetized tests of the beat-wave concept which involve coupling to unmagnetized electron plasma waves rather than magnetized EBWs. Should these experiments prove successful, we plan to submit a follow-up proposal for additional funding which would allow us to undertake the magnetized EBW experiments.

42 ENGINEERING↗

Luminescence properties in relation to controllable morphologies of the InBO{sub 3}:Eu{sup 3+} phosphor

Graphical abstract: Four kinds of morphologies of Eu{sup 3+} doped indium borate of InBO{sub 3} phosphors have been prepared via a facile flux method only by adjusting the kinds of reaction boron source materials[(a)B{sub 2}O{sub 3}, (b)NH{sub 4}B{sub 5}O{sub 8}·4H{sub 2}O, (c)Li{sub 2}B{sub 4}O{sub 7}, (d)K{sub 2}B{sub 4}O{sub 7}·4H{sub 2}O], in which the monodisperse octahedral sample prepared with K{sub 2}B{sub 4}O{sub 7}·4H{sub 2}O as the boron source and Eu{sup 3+} doping concentration being 5% possesses the higher PL intensity and color purity, which can be used as a potential orange luminescent material. - Highlights: • InBO{sub 3}:Eu{sup 3+} phosphor with four morphologies were prepared by adjusting the boron source. • The doping concentration also has a great influence on the morphology. • The fluorescence performance is strongly correlated with morphology. • The smooth octahedral sample possesses the higher PL intensity and color purity. • InBO{sub 3}:Eu{sup 3+} smooth octahedra can be used as a potential orange luminescent material. - Abstract: Four kinds of morphologies of Eu{sup 3+} doped indium borate of the InBO{sub 3} phosphors have been prepared via a facile flux method only by adjusting the kinds of reaction boron source materials, which have been characterized by XRD, EDS and SEM. In addition, the doping concentration also has a great influence on the morphology of samples. Furthermore, the luminescence properties of the prepared InBO{sub 3}:Eu{sup 3+} samples have been investigated by photoluminescence (PL) spectra. The results show that the fluorescence performance is strongly correlated with morphologies. The prepared InBO{sub 3}:Eu{sup 3+} phosphors show strong orange emissions under ultraviolet excitation at 237 nm, in which the monodisperse octahedra sample prepared with K{sub 2}B{sub 4}O{sub 7}·4H{sub 2}O as the boron source and Eu{sup 3+} doping concentration being 5% possesses the higher PL intensity and color purity, which can be used as a potential orange luminescent material.

36 MATERIALS SCIENCE↗

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

Novel methods for improvement of a Penning ion source for neutron generator applications

Penning ion source performance for neutron generator applications is characterized by the atomic ion fraction and beam current density, providing two paths by which source performance can be improved for increased neutron yields. We have fabricated a Penning ion source to investigate novel methods for improving source performance, including optimization of wall materials and electrode geometry, advanced magnetic confinement, and integration of field emitter arrays for electron injection. Effects of several electrode geometries on discharge characteristics and extracted ion current were studied. Additional magnetic confinement resulted in a factor of two increase in beam current density. First results indicate unchanged proton fraction and increased beam current density due to electron injection from carbon nanofiber arrays.

43 PARTICLE ACCELERATORS↗

SUBMILLIMETER AND MOLECULAR VIEWS OF THREE GALACTIC RING-LIKE H II REGIONS

We use SCUBA 850 {mu}m and CO observations to analyze the surroundings of three Galactic ring-like H II regions, KR 7, KR 81, and KR 120 (Sh 2-124, Sh 2-165, and Sh 2-187), with the aim of finding sites of triggered star formation. We find one prominent submillimeter (sub-mm) source for each region, located at the interface between the H II region and its neutral surroundings. Using Two Micron All Sky Survey photometry, we find that the prominent sub-mm source for KR 120 probably contains an embedded cluster of young stellar objects (YSOs), making it a likely site for triggered star formation. The KR 7 sub-mm source could possibly contain embedded YSOs, while the KR 81 sub-mm source likely does not. The mass column densities for these dominant sub-mm sources fall in the {approx}0.1-0.6 g cm{sup -2} range. The mass of the cold, dense material (clumps) seen as the three dominant sub-mm sources falls around {approx}100 M{sub sun}. We use the SCUBA Legacy catalog to characterize the populations of sub-mm sources around the H II regions, and compare them to the sources found around a previously studied similar ring-like H II region (KR 140) and near a massive star-forming region (W3). Finally, we estimate the IR luminosities of the prominent newly detected sub-mm sources and find that they are correlated with the clump mass, consistent with a previously known luminosity-mass relationship which this study shows to be valid over four orders of magnitude in mass.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray optics for the cavity-based X-ray free-electron laser

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

47 OTHER INSTRUMENTATION↗

Wind Plant Performance Prediction Benchmark Phase 1 (Technical Report)

Financial risk resulting from the uncertainty associated with developing, owning, and operating wind power plants remains a barrier to reducing the levelized cost of energy (LCOE). On average, modern wind power plants in the U.S. underperform their expected annual energy output by 3.5-4.5% , with many underperforming by over 10%. To compensate for this uncertainty, investors require a larger return on investment (ROI) and apply "knock-down" factors that mask much of the underlying sources of uncertainty. Wind energy projects thus have reduced access to low-cost capital. Furthermore, operating wind plants often take a simple approach to estimating operations & maintenance (O&M) costs (e.g. straight-line estimates based on similar plants), which can eat into profits. To overcome these issues, the wind industry must improve the models they use for estimating wind plant performance and operations. An industry consortium (IC) requested that the National Renewable Energy Laboratory (NREL) lead a Department of Energy (DOE) working group to benchmark the accuracy of wind power plant energy predictions against real operational data. The IC was also motivated by DOE and NREL's potential to characterize systematic energy underperformance, identify sources of uncertainty, and explore root causes. The Wind Plant Performance Prediction (WP3) project was created out of this request, and this report represents the successful completion of Phase 1 of the WP3 project. During the project, wind plant owners provided both pre-construction and operational data to NREL. The pre-construction data was provided to wind resource assessment (WRA) consultants so they could conduct energy yield assessments (EYA). NREL took all of the completed EYAs, along with the operational data, and conducted an operational assessment to benchmark the EYA results against actual operational data. Given the large amounts of sensitive data required for this effort, as well as historical opposition to sharing data within industry, successful completion of Phase 1 represents an unprecedented milestone for industry data sharing. To improve the accuracy and confidence of pre-construction EYAs, wind plant owners and investors need better, more certain, energy yield predictions. The WP3 Benchmark Project is an industry-driven response to this reality. For the first time, industry has taken the important step of working together at scale, sharing valuable operational data with DOE and NREL in order to investigate the sources of bias and uncertainty in these energy estimates. This IC provides wind plant preconstruction and operational data to NREL in an organized and documented fashion and provides guidance and feedback as needed. The IC also provides introspection of the design of experiment, key metrics of success, data challenges, analysis best practices, and quality of results.

17 WIND ENERGY↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

Flux and estimated spectra from a low-intensity laser-driven X-ray source

Laser-driven X-rays as probes for high-energy-density physics spans an extremely large parameter space with laser intensities varying by 8 orders of magnitude. We have built and characterized a soft X-ray source driven by a modest intensity laser of 4 × 10 13 W/cm 2 . Emitted X-rays were measured by diamond radiation detectors and a filtered soft X-ray camera. A material-dependence study on Al, Ti, stainless steel alloy 304, Fe, Cu and Sn targets indicated 5-μm-thick Cu foils produced the highest X-ray yield. X-ray emission in the laser direction and emission in the reverse direction depend strongly on the foil material and the thickness due to the opacity and hydrodynamic disassembly time. The time-varying X-ray signals are used to measure the material thinning rate and is found to be ~1.5 μm/ns for the materials tested implying thermal temperature around 0.6 eV. The X-ray spectra from Cu targets peaks at ~2 keV with no emission >4 keV and was estimated using images with eight different foil filters. One-dimensional hydrodynamic and spectral calculations using HELIOS-CR provide qualitative agreement with experimental results. Modest intensity lasers can be an excellent source for nanosecond bursts of soft X-rays.

47 OTHER INSTRUMENTATION↗

Crowd-based spatial risk assessment of urban flooding: Results from a municipal flood hotline in Detroit, MI

Climate change is increasing the frequency and intensity of extreme precipitation events, raising the risk of urban flood disasters. This study uses a crowd-sourced municipal call database to characterize the spatial distribution of flood risk in Detroit, MI. Call data including dates and addresses were obtained from the City of Detroit Department of Public Works for 2021. Calls were mapped and aggregated to census tract counts and merged with neighborhood-level data. Associations of predictors with flood calls were tested using spatial regression models. Flooding calls were located throughout the city but were concentrated in specific areas. Multivariate models of census tract level call counts indicated that increased poverty and Black, immigrant, and older residents were positively associated with flood calls, while increased elevation was associated with protective effects. Longer distances from waste water interceptors were associated with higher risk for calls. Crowd-sourced flood hotline call data can be used for effective spatial flood risk assessment. Though flooding occurs throughout the city of Detroit, infrastructural, neighborhood, and household factors influence flooding extent. Limitations included the self-reported nature of calls. Future modeling efforts might include input from local stakeholders to improve spatial risk assessment.

54 ENVIRONMENTAL SCIENCES↗

Characterization of high-quality kerfless epitaxial silicon for solar cells: Defect sources and impact on minority-carrier lifetime

We investigate the types and origins of structural defects in thin (<100 μm) kerfless epitaxial single crystal silicon grown on top of reorganized porous silicon layers. Although the structural defect density is low (has average defect density < 10 4 cm -2 ), localized areas with a defect density > 10 5 cm -2 are observed. Cross-sectional and systematic plan-view defect etching and microscopy reveals that the majority of stacking faults and dislocations originate at the interface between the porous silicon layer and the epitaxial wafer. Localised dislocation clusters are observed in regions of collapsed/deformed porous silicon and at decorated stacking faults. In localized regions of high extended defect density, increased minority-carrier recombination activity is observed. Evidence for impurity segregation to the extended defects (internal gettering), which is known to exacerbate carrier recombination is demonstrated. In conclusion, the impact of the defects on material performance and substrate re-use is also discussed.

14 SOLAR ENERGY↗

Synthesis and Characterization of Lignin-grafted-poly(ε-caprolactone) from Different Biomass Sources

Modification of lignin with poly(ε-caprolactone) is a promising approach to valorize industrial low-value lignins and to advance the bioeconomy. We have synthesized lignin grafted poly(ε-caprolactone) (lignin-g-PCL) copolymers via ring-opening polymerization of ε-caprolactone with different types of lignins of varying botanical sources (G-type pine lignin, S/G-type poplar lignin, and C-type Vanilla seeds lignin) and lignin extraction methods (Kraft and ethanol organosolv pulping). The lignin-g-PCL copolymer showed remarkably improved compatibility and dispersion in acetone, chloroform, and toluene in comparison to non-modified lignins. The structure and thermal properties of the lignin-g-PCL were investigated using Fourier-transform infrared spectroscopy (FTIR), 31 P nuclear magnetic resonance (NMR), 2D heteronuclear single quantum correlation (HSQC) NMR, gel permeation chromatography (GPC), and differential scanning calorimetry (DSC). Furthermore, we have found that all the technical lignins were reactive to the copolymerization reaction regardless of their plant source and isolation methods. The molecular weights of the synthesized lignin-g-PCL copolymers were positively correlated with the content of aliphatic lignin hydroxyls, suggesting that the copolymerization reaction tends to occur preferentially at the aliphatic hydroxyls rather than the phenolic hydroxyls of lignin. Thermal analyses of the lignin-g-PCL copolymers were studied, and in general, a reduction of melting temperature and crystallinity percentage in comparison to the neat PCL was observed. However, the thermal behavior of lignin-g-PCL copolymers varied depending on the lignin feedstocks employed in the copolymerization reaction.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Boron Contamination in Fluorine Implantation using Boron Trifluoride as a Source Material

Fluorine implantation process purity was considered on different types of high current implanters. It was found that implanters equipped with an indirectly heated cathode ion source show an enhanced deep boron contamination compared to a high current implanter using a cold RF-driven multicusp ion source when boron trifluoride is used for fluorine implantations. This contamination is directly related to the source technology and thus, should be considered potentially for any implanter design using hot cathode/hot filament ion source, independently of the manufacturer.The boron contamination results from the generation of double charged boron ions in the arc chamber and the subsequent charge exchange reaction to single charged boron ions taking place between the arc chamber and the extraction electrode. The generation of the double charged boron ions depends mostly on the source parameters, whereas the pressure in the region between the arc chamber and the extraction electrode is mostly responsible for the charge exchange from double charged to single charged ions. The apparent mass covers a wide range, starting at mass 11. A portion of boron ions with energies of (19/11) times higher than fluorine energy has the same magnetic rigidity as fluorine beam and cannot be separated by the analyzer magnet. The earlier described charge exchange effects between the extraction electrode and the entrance to the analyzer magnet, however, generates boron beam with a higher magnetic rigidity compared to fluorine beam and cannot cause boron contamination after mass-separation.The energetic boron contamination was studied as a function of the ion source parameters, such as gas flow, arc voltage, and source magnet settings, as well as analyzing magnet aperture resolution. This allows process optimization reducing boron contamination to the level acceptable for device performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fermi Large Area Telescope Bright Gamma-ray Source List

Following its launch in 2008 June, the Fermi Gamma-ray Space Telescope (Fermi) began a sky survey in August. The Large Area Telescope (LAT) on Fermi in three months produced a deeper and better resolved map of the {gamma}-ray sky than any previous space mission. We present here initial results for energies above 100 MeV for the 205 most significant (statistical significance greater than {approx}10{sigma}) {gamma}-ray sources in these data. These are the best characterized and best localized point-like (i.e., spatially unresolved) {gamma}-ray sources in the early mission data.

Astrophysics,ASTRO↗

FERMI/LARGE AREA TELESCOPE BRIGHT GAMMA-RAY SOURCE LIST

Following its launch in 2008 June, the Fermi Gamma-ray Space Telescope (Fermi) began a sky survey in August. The Large Area Telescope (LAT) on Fermi in three months produced a deeper and better resolved map of the {gamma}-ray sky than any previous space mission. We present here initial results for energies above 100 MeV for the 205 most significant (statistical significance greater than {approx}10{sigma}) {gamma}-ray sources in these data. These are the best characterized and best localized point-like (i.e., spatially unresolved) {gamma}-ray sources in the early mission data.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of Wastewater Treatment Plant Microbial Communities and the Effects of Carbon Sources on Diversity in Laboratory Models

We are developing a laboratory-scale model to improve our understanding and capacity to assess the biological risks of genetically engineered bacteria and their genetic elements in the natural environment. Our hypothetical scenario concerns an industrial bioreactor failure resulting in the introduction of genetically engineered bacteria to a downstream municipal wastewater treatment plant (MWWTP). As the first step towards developing a model for this scenario, we sampled microbial communities from the aeration basin of a MWWTP at three seasonal time points. Having established a baseline for community composition, we investigated how the community changed when propagated in the laboratory, including cell culture media conditions that could provide selective pressure in future studies. Specifically, using PhyloChip 16S-rRNA-gene targeting microarrays, we compared the compositions of sampled communities to those of inocula propagated in the laboratory in simulated wastewater conditionally amended with various carbon sources (glucose, chloroacetate, D-threonine) or the ionic liquid 1-ethyl-3-methylimidazolium chloride ([C2mim]Cl). Proteobacteria , Bacteroidetes , and Actinobacteria were predominant in both aeration basin and laboratory-cultured communities. Laboratory-cultured communities were enriched in γ- Proteobacteria . Enterobacteriaceae , and Aeromonadaceae were enriched by glucose, Pseudomonadaceae by chloroacetate and D-threonine, and Burkholderiacea by high (50 mM) concentrations of chloroacetate. Microbial communities cultured with chloroacetate and D-threonine were more similar to sampled field communities than those cultured with glucose or [C2mim]Cl. Although observed relative richness in operational taxonomic units (OTUs) was lower for laboratory cultures than for field communities, both flask and reactor systems supported phylogenetically diverse communities. These results importantly provide a foundation for laboratory models of industrial bioreactor failure scenarios.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Spall in Hard Rock from Observations and Simulations of the Source Physics Experiment Phase I

In this work, spall signals from the Source Physics Experiments are presented, analyzed, and modeled for insight to the explosion source. The observed signal is similar in nature to nearby historical nuclear explosions, and the surface force-time history or velocity can be interpreted with the same model. We use the models for peak spall velocity, spalled mass, and spall depth and radius derived from historical nuclear explosions to parameterize the physical force-time history model from Stump (1985) and show that this parameterized model can be used for spall prediction. The spall signal is also investigated with a numerical continuum model that incorporates gravity. Peak velocity and dwell time are well predicted, and the multiple slap-down phases are captured if one includes a weak near-surface layer similar to the geologic observation.

58 GEOSCIENCES↗