Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Subcriticality Measurements with HEU (93.2) Metal Annular Storage Castings

These carefully performed and documented measurements with unreflected and unmoderated highly enriched uranium (HEU) castings can be used to benchmark calculational methods for the time decay of the fission chain multiplication process as measured with small (1 x 1 x 6 in. thick plastic scintillators with 1/4-in.-thick lead on all detector surfaces) detectors adjacent to the tightly fitting stainless steel cans that contained the HEU ({approx}93 wt%) metal. Prompt time decay measurements were performed stimulating the fission chain multiplication process with a timed, tagged Cf spontaneous fission source that emitted fission-spectrum neutrons and a time and directionally tagged 14.1-MeV neutrons from the DT reaction in a steady state generator with an embedded alpha detector. Time decay measurements were performed with HEU masses varying from 18 to 90 kg for a wide variety of source-detector-casting configurations. The use of a DT generator provided no addition information about the fission chain behavior beyond that provided by a time-tagged Cf spontaneous fission source. The main quantities obtained in the measurements were (1) the time distribution of the counts in a detector after a neutron fission in the Cf source or after the alpha detection coincident with the emission of a neutron from the DT generator (the equivalent of a pulsed neutron measurement with a randomly pulsed source) and (2) the time distribution of counts in one detector after a count in another detector (the equivalent of a two-detector Rossi-alpha measurement). Monte Carlo calculations using the MCNP-PoliMi coupled gamma-neutron transport code generally agreed with the measurement results except for some differences early in the fission chain decay process. The measurements that were performed with the HEU about 1 m above the floor were considerably affected by room return neutrons at times as early as 100 ns, and at times after 300 ns, a major portion of the time response was associated with the interaction of the HEU assemblies with the floor. This room-return effect increased with the size of the assembly because the larger assemblies subtend a larger solid angle to a neutron returning from the floor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-201-08: Flexible Dosimeter Bands for Whole-Body Dosimetry

Purpose: The two commonly used radiotherapy techniques are total body irradiation (TBI) and the total skin irradiation (TSI). In order to ensure the accuracy of the prescription beams, the dose received throughout the entire body must be checked using dosimetry. However, the available number of data points is limited as the dosimeters are manually placed on the patient. We developed a flexible and wearable dosimeter that can collect 1D continuous dose information around the peripheral of the patients’ body, including areas obscured from the beam path. Methods: The flexible dosimeter bands are fabricated by embedding storage phosphor powders in a thin layer of non-toxic silicone based elastomer (PDMS). An additional elastomer layer is formed on top of the phosphor layer to provide additional mechanical support for the dosimeter. Once the curing process is complete, the dosimeter is cut into multiple bands and rolled into spools prior to use. Results: The dose responses are tested using a preclinical cabinet X-ray system, where the readout is performed with a storage phosphor reader. Results show that the dose calibration factor is ∼1400 (A.U./Gy) from the beam center. Also, 1-D dose distribution experiment was performed in water phantoms, where preliminary results demonstrate that the dose in water is indeed attenuated compared to in air. Conclusion: Dose response and high-resolution 1-D dosimetry is demonstrated using the flexible dosimeters. By providing a detailed spatial description of the beam dose profile, we expect that the dosimeter bands may aid in enhancing the current existing modality in dosimetry. Since the dosimeter is flexible (can retract back to its original length), they can be comfortably worn around the patient. Potentially, multiple 1-D dose information can be stitched together and extrapolated to provide a coarse 3-D image of the dose distribution. This work was supported by funding from the Cutaneous Lymphoma Foundation under the CLARIONS grant.

60 APPLIED LIFE SCIENCES↗

Designing MOFs-Derived FeS 2 @Carbon Composites for High-Rate Sodium Ion Storage with Capacitive Contributions

We present that sodium-ion batteries suffer the disadvantages of poor rate performance and cycling stability due to its sluggish sodiation kinetics. A rational design strategy for both materials compositions and structures has been proposed to meet these challenges. Herein, a triple-component composite derived from metal organic frameworks, comprising FeS 2 , nitrogen sulfur co-doped porous carbon, and reduced graphene oxide (FeS 2 @NSC/G), has been successfully synthesized. With the capacities contributions from different sodium storage routes (diffusion-controlled processes and surface capacitive processes) at varies rate conditions, it is aiming to make full use of each component in the electrode composite and their unique porous structures. Expected electrode properties have been achieved and related electrochemical could behaviors have also been investigated. Finally, the strategy would present a promising thought for composites design, which enhance high-rate electrochemical energy storage performances.

25 ENERGY STORAGE↗

Revealing the dynamics of ultrarelativistic non-equilibrium many-electron systems with phase space tomography

The description of physical processes with many-particle systems is a key approach to the modeling of numerous physical systems. For example in storage rings, where ultrarelativistic particles are agglomerated in dense bunches, the modeling and measurement of their phase-space distribution is of paramount importance: at any time the phase-space distribution not only determines the complete space-time evolution but also provides fundamental performance characteristics for storage ring operation. Here, we demonstrate a non-destructive tomographic imaging technique for the 2D longitudinal phase-space distribution of ultrarelativistic electron bunches. For this purpose, we utilize a unique setup, which streams turn-by-turn near-field measurements of bunch profiles at MHz repetition rates. To demonstrate the feasibility of our method, we induce a non-equilibrium state and show that the phase-space distribution microstructuring as well as the phase-space distribution dynamics can be observed in great detail. Our approach offers a pathway to control ultrashort bunches and supports, as one example, the development of compact accelerators with low energy footprints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preliminary Thermal Stress Analysis of a High-Pressure Cryogenic Storage Tank

The thermal stresses on a cryogenic storage tank strongly affect the condition of the tank and its ability to withstand operational stresses. These thermal stresses also affect the growth of any surface damage that might occur in the tank walls. These stresses are particularly of concern during the initial cooldown period for a new tank placed into service, and during any subsequent thermal cycles. A preliminary thermal stress analysis of a high-pressure cryogenic storage tank was performed. Stresses during normal operation were determined, as well as the transient temperature distribution. An elastic analysis was used to determine the thermal stresses in the inner wall based on the temperature data. The results of this elastic analysis indicate that the inner wall of the storage tank will experience thermal stresses of approximately 145,000 psi (1000 MPa). This stress level is well above the room-temperature yield strength of 304L stainless steel, which is about 25,000 psi (170 MPa). For this preliminary analysis, several important factors have not yet been considered. These factors include increased strength of 304L stainless steel at cryogenic temperatures, plastic material behavior, and increased strength due to strain hardening. In order to more accurately determine the thermal stresses and their affect on the tank material, further investigation is required, particularly in the area of material properties and their relationship to stress.

Baker, J. Mark↗

Robust Atomic-Resolution Imaging of Lithium in Battery Materials by Center-of-Mass Scanning Transmission Electron Microscopy

The performance of energy storage materials is often governed by their structure at the atomic scale. Conventional electron microscopy can provide detailed information about materials at these length scales, but direct imaging of light elements such as lithium presents a challenge. While several recent techniques allow lithium columns to be distinguished, these typically either involve complex contrast mechanisms that make image interpretation difficult or require significant expertise to perform. In this work, we demonstrate how center-of-mass scanning transmission electron microscopy (CoM-STEM) provides an enhanced ability for simultaneous imaging of lithium and heavier element columns in lithium ion conductors. Through a combination of experiments and multislice electron scattering calculations, we show that CoM-STEM is straightforward to perform and produces directly interpretable contrast for thin samples, while being more robust to variations in experimental parameters than previously demonstrated techniques. As a result, CoM-STEM is positioned to become a reliable and facile method for directly probing all elements within energy storage materials at the atomic scale.

25 ENERGY STORAGE↗

FY 2014 Status Report: of Vibration Testing of Clad Fuel (M4FT-14OR0805033)

The DOE Used Fuel Disposition Campaign (UFDC) tasked Oak Ridge National Laboratory (ORNL) to investigate the behavior of light-water-reactor (LWR) fuel cladding material performance related to extended storage and transportation of UNF. ORNL has been tasked to perform a systematic study on UNF integrity under simulated normal conditions of transportation (NCT) by using the recently developed hot-cell testing equipment, Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT). To support the testing on actual high-burnup UNF, fast-neutron irradiation of pre-hydrided zirconium-alloy cladding in the High Flux Isotope Reactor (HFIR) at elevated temperatures will be used to simulate the effects of high-burnup on fuel cladding for help in understanding the cladding materials properties relevant to extended storage and subsequent transportation. The irradiated pre-hydrided metallic materials testing will generate baseline data to benchmark hot-cell testing of the actual high-burnup UNF cladding. More importantly, the HFIR-irradiated samples will be free of alpha contamination and can be provided to researchers who do not have hot cell facilities to handle highly contaminated high-burnup UNF cladding to support their research projects for the UFDC.t

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems [Slides]

The study performed two related analyses using data from a new-construction residential community equipped with rooftop solar and storage (S+S) in Arizona. The study analyzed the factors that determine customer electricity cost savings from S+S adoption. The research compared the Arizona case study data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, NREL explored ways to improve such models and, conversely, use modeled results to suggest improvements to S+S dispatches.

14 SOLAR ENERGY↗