Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface breakdown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Building the next high voltage dc photogun polarized source for the ILC at JLab

During the ILC Global Design Effort (2007) two 200 kV high voltage photoguns based on an inverted insulator geometry were developed in 2010 and successfully tested at Jefferson Lab (JLab). One of the photoguns has been operated at 130 kV in the CEBAF accelerator for the JLab nuclear physics program. The inverted insulator replaces the electrode support structure, consequently significantly less metal prone to field emission is biased and surfaces contributing to the vacuum load are significantly reduced. Implementing a biased anode, and using a larger laser spot size has made this the state of the art polarized beam source with ~200 C charge lifetime from SSL GaAs photocathodes. However, operating at the design 200 kV voltage has been hindered by field emission at ~190 kV. To reliably operate without field emission requires lengthy conditioning applying 50-100 kV beyond the voltage needed for beam operations, without breakdown or damage to the insulator. Over the past decade, JLab has developed two photoguns with a larger version of the commercial inverted insulators used in the ILC design. One photogun operated at 300 kV for magnetized beam studies, and the concept has been implemented in the BNL polarized photogun. The second photogun has recently been installed in CEBAF to operate at 200 kV field emission free. Higher voltage photoguns help the ILC and CLIC achieve higher bunch charge (2013 TDR), and additionally provide margin for operating with shorter laser pulse length and/or smaller laser spot size (better emittance at higher peak current). Such photogun designs need to reach ~400 kV without breakdown or insulator damage to operate field emission free at > 300 kV. This also allows for direct injection into a SRF booster. JLab submitted a proposal to HEP for developing in partnership with industry an inverted geometry insulator to fit commercial 400 kV cables. This contribution describes JLab experience developing and testing high voltage photoguns, and what is needed to sufficiently condition for voltage levels higher than beam operational voltage.

Hernandez-Garcia, Carlos↗

Radiative properties of an artificial atom coupled to a Josephson-junction array

We study the radiative properties—the Lamb shift, Purcell decay rate, and spontaneous emission dynamics—of an artificial atom coupled to a long, multimode cavity formed by an array of Josephson junctions. Introducing a tunable coupling element between the atom and the array, we demonstrate that such a system can exhibit a crossover from a perturbative to a nonperturbative regime of light-matter interaction as one strengthens the coupling between the atom and the Josephson-junction array. As a consequence, the concept of spontaneous emission as the occupation of the local atomic site being governed by a single complex-valued exponent breaks down. This breakdown, we show, can be interpreted in terms of formation of hybrid atom-resonator modes with radiative losses that are nontrivially related to the effective coupling between individual modes. We develop a singular function expansion approach for the description of the open quantum system dynamics in such a multimode nonperturbative regime. This modal framework generalizes the normal-mode description of quantum fields in a finite volume, incorporating exact radiative losses and incident quantum noise at the delimiting surface. Our results are pertinent to recent experiments with Josephson atoms coupled to high-impedance Josephson-junction arrays.

42 ENGINEERING↗

High Temperature Erosion In Particle Based CSP Systems

Particle based concentrated solar power plants are increasingly being considered as an alternative to molten salts. Although these particle based systems provide the inherent safety and enhanced lifetime from reduced corrosion compared to molten salt systems, they bring in complexities associated with surface erosion from falling particle impact and sliding motion along the surfaces. Past research on particle related erosion has been limited to high velocity applications and doesn’t necessarily coincide with the operating conditions in CSP systems. In our work, we evaluate characterize the rate of erosion for particles and containment materials at 800ºC. Three different types of erosion resulting from a) impact of solid particles on receiver, particle storage, and heat exchanger walls; b) abrasion erosion from particle sliding motion along walls; and c) attrition erosion as the particles breakdown from particle-to-particle contact and particle-to-wall interactions are evaluated and compared across a varied spectrum of particle and containment material spectrum. From the results, It is noted that temperature plays a key role in the rate of erosion experienced by any material. With the increase in temperature, materials become more ductile and are more readily sheared away from particle impinging or sliding motion. Furthermore, the particles themselves have higher susceptibility to breakdown which also lowers particle thermal absorptance and thus efficiency as heat transfer fluid.

14 SOLAR ENERGY↗

Plume flowfield analysis of the shuttle primary Reaction Control System (RCS) rocket engine

A solution was generated for the physical properties of the Shuttle RCS 4000 N (900 lb) rocket engine exhaust plume flowfield. The modeled exhaust gas consists of the five most abundant molecular species, H2, N2, H2O, CO, and CO2. The solution is for a bare RCS engine firing into a vacuum; the only additional hardware surface in the flowfield is a cylinder (=engine mount) which coincides with the nozzle lip outer corner at X = 0, extends to the flowfield outer boundary at X = -137 m and is coaxial with the negative symmetry axis. Continuum gas dynamic methods and the Direct Simulation Monte Carlo (DSMC) method were combined in an iterative procedure to produce a selfconsistent solution. Continuum methods were used in the RCS nozzle and in the plume as far as the P = 0.03 breakdown contour; the DSMC method was used downstream of this continuum flow boundary. The DSMC flowfield extends beyond 100 m from the nozzle exit and thus the solution includes the farfield flow properties, but substantial information is developed on lip flow dynamics and thus results are also presented for the flow properties in the vicinity of the nozzle lip.

Hueser, J. E.↗

High Temperature Erosion In Particle Based CSP Systems

Particle based concentrated solar power plants are increasingly being considered as an alternative to molten salts. Although these particle based systems provide the inherent safety and enhanced lifetime from reduced corrosion compared to molten salt systems, they bring in complexities associated with surface erosion from falling particle impact and sliding motion along the surfaces. Past research on particle related erosion has been limited to high velocity applications and doesn’t necessarily coincide with the operating conditions in CSP systems. In our work, we evaluate characterize the rate of erosion for particles and containment materials at 800ºC. Three different types of erosion resulting from a) impact of solid particles on receiver, particle storage, and heat exchanger walls; b) abrasion erosion from particle sliding motion along walls; and c) attrition erosion as the particles breakdown from particle-to-particle contact and particle-to-wall interactions are evaluated and compared across a varied spectrum of particle and containment material spectrum. From the results, It is noted that temperature plays a key role in the rate of erosion experienced by any material. With the increase in temperature, materials become more ductile and are more readily sheared away from particle impinging or sliding motion. Furthermore, the particles themselves have higher susceptibility to breakdown which also lowers particle thermal absorptance and thus efficiency as heat transfer fluid.

14 SOLAR ENERGY↗

Computer System for Unattended Control of Negative Ion Source

The computer system for control of cw surface-plasma source of negative ions is described. The system provides an automatic handling of source parameters by the specified scenario. It includes the automatic source start and long-term operation with switching and control of the power supplies blocks, setting and reading of source parameters like hydrogen feed, cesium seed, electrodes' temperature, checking of the protection and blockings elements like vacuum degradation, absence of cooling water, etc. The semi-automatic mode of control is also available, where the order of steps and magnitude of parameters, included to scenario, is corrected in situ by the operator. Control system includes the main controller and a set of peripheral local controllers. Commands execution is carried out by the main controller. Each peripheral controller is driven by the stand-alone program, stored in its ROM. Control system is handled from PC via Ethernet. The PC and controllers are connected by fiber optic lines, which provide the high voltage insulation and the stable system operation in spite the breakdowns and electromagnetic noise of cross-field discharge. The PC program for data setting and information display is developed under the LabView.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Breakdown and Discharge Characteristics of High Repetition Frequency Nanosecond Pulsed Air Dielectric Barrier Discharge

This study explores the breakdown characteristics and discharge modes in a parallel plate air dielectric barrier discharge system using repetitive nanosecond pulses, with pulse repetition frequencies (PRFs) from 0.1 to 100 kHz. It examines how pulse parameters—PRF, pulse number and gas pressure—affect the memory effect, leveraging current and voltage measurements, fast imaging and optical emission spectroscopy. The findings show that higher PRFs lead to a reduction in breakdown voltage well below the streamer breakdown threshold. We argue that this effect may be attributed to the cumulative buildup of metastable species and negative ions in the discharge gap which could sustain free electrons in‐between the voltage pulses. Despite observing increased energy deposition with higher PRFs, the impact on filament formation was minimal, highlighting a strong dependence of discharge morphology on the accumulation of plasma‐produced species. This research studies provides valuable insights for controlling discharge regimes in applications such as plasma‐assisted combustion, surface treatment and air treatment by clarifying the interactions between discharge mechanisms at different PRFs and pressures.

42 ENGINEERING↗

Exploration of LIBS as a novel and rapid elemental mapping technique of nuclear fuels in the form of surrogate TRISO particles

Laser-induced breakdown spectroscopy (LIBS) was employed to characterize coatings on surrogate fuel particles. Tri-structural isotropic (TRISO) particles are a proposed nuclear fuel alternative for high temperature reactors. These particles are constructed of a ZrO 2 kernel (as a surrogate to uranium), surrounded by an inner pyrolytic carbon layer and are surrounded by an outer carbide layer (ZrC, presented here) to act as a barrier to fission products generated during nuclear reactions. These particles are embedded within a graphite compact and housed within the reactor core. Simply put, due to their robust nature, performing elemental analysis of these particles poses a challenge. Presented here, LIBS is explored as a method for characterizing elemental constituents of these particles, with the focus being on rapid elemental mapping and depth profiling. Different from traditional elemental analysis techniques (e.g., inductively coupled plasma – based methods), LIBS is advantageous because it can directly analyze the sample surface and can detect light elements such as C and O, making it a viable technique for the analysis of small, multilayered particles as spatial elemental information is warranted in the production of these particles. In the work presented here, LIBS was successfully used for discerning small layers (30–50 μm), detecting the location of carbon and oxygen layers, providing fast 2-D mapping (<5 min per particle) and rapid depth profiling (10 s per particle).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of plasma temperature and electron density on nanosecond laser ablation of Cu and nano-Cu

Laser-induced breakdown spectroscopy is performed through the collection of spectra by spectral detection equipment at different delay times and distances from targets composed of Cu and nano-Cu, which are ablated using a Nd:YAG laser (532 nm, 10 ns, 10 Hz) in our experiments. The measured wavelength range is from 475 nm to 525 nm. Using the local thermodynamic equilibrium model, we analyze the characteristics of the plasma temperature and the electron number density for different distances between the target surface and the lens. The results show that when compared with the nano-Cu plasma case, the temperature of the Cu plasma is higher, while its electron number density is lower.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing the antenna system of a microwave space power station: Implications for the selection of operating power, frequency and antenna size

A design for a space power station that is to transmit power to the surface of a planet via high powered microwaves should commence with the optimum design of the transmitting and receiving antenna combination to be employed. Once one has assured that the desired amount of power has been transferred (which, after all, is the prupose of any power transmission system), one can, from the constraints imposed by such a design, taylor other parameters of the system such as antenna sizes and weights, power density in the planet's atmosphere (e.g., to avoid electrical breakdown), and frequency of operation. It is the purpose of this brief analysis to provide the working equations of such an optimized antenna system, and to give examples of their use. Related problems that should be analyzed in the future will then be discussed and a flow chart of the indicated order of priority presented. The analysis given here differs from previous work on this subject in that the development given will allow analytical expressions to be obtained for the relevant parameters. This is made possible by employing an approximation procedure to be given during the exposition.

Manning, Robert M.↗

Vortex pattern development on the upper surface of a swept wing at high angle of attack

An experimental study, based on a swept wing, was undertaken in the water tunnel and the wind tunnel at low speeds, with a view to improving the understanding of the intervening phenomena and to make easier their modelling. The vortex flow effects on the wing are first illustrated from global effort measurements and static pressure distributions. The domain of existence of this type of flow is deduced as a function of both sweep angle and angle of attack. By a phenomenological study in the water tunnel, an attempt is made to describe the physical pattern of the vortex flow, from its formation near the apex to its breakdown at the trailing edge. Lastly, by means of a clinometric probe, the flow field over the wing is determined.

Mirande, J.↗

The formation of peroxonitrites and oxygen on Mars

When Martian regolith samples are moistened with water, a strong oxidant and oxygen gas are released. The many possible oxidants which have been suggested as present, including superoxide (O2(-)) hydrogen peroxide (H2O2(-)), and manganese (IV) oxide (MnO2), as well as peroxonitrite (ONOO(-)), can be distinguished by their ability to account for the numerous observations of the Viking Labelled Release (LR) and Gas Exchange (GEX) experiments. The magnitudes, kinetics, and heat labilities of the LR experiments and the magnitudes and heat labilities of the GEX experiments have been quantitatively replicated with peroxonitrites. Further, it is to be expected from information about the photochemistry of nitrogen in the atmosphere, the calculated fluxes of the NO(x) to the surface, the known reactions of NO(x) with carbonates to produce nitrates and photolysis studies of nitrates, that peroxonitrites are present on Mars. However, considerable uncertainty has existed about the form in which oxygen is stored in photolyzed nitrate crystals. Models have ranged from micropores of O2 to chemically bound oxygen as peroxonitrite (O2NOO(-)), as well as peroxonitrite. Studies of the solution chemistry and solid state photochemistry were completed, which show that much of the oxygen evolved on wetting comes from thermal breakdown of peroxonitrite after it is dissolved. A chemical model is developed for the photochemical processes occurring during UV irradiation of solid nitrates which resolves the several contradictory models discussed in the literature in recent years.

Plumb, Robert C.↗

Copper enrichments in the Kimberley formation in Gale crater, Mars: Evidence for a Cu deposit at the source

Copper quantification with laser induced breakdown spectroscopy (LIBS) using a univariate calibration model enables the ChemCam instrument onboard the Curiosity rover to measure unusually elevated Cu concentrations in potassic sandstones and Mn-oxide-bearing fracture fills in the Kimberley region of Gale crater, Mars. Mostly, the copper phases occurring in sedimentary bedrock are associated with detrital silicates, including feldspars, pyroxenes and K-phyllosilicates, likely coming from a potassic igneous source near the northern crater rim, while those present in the fractures are likely adsorbed on the surface of manganese oxides. These two different mineralogical associations imply at least two distinct processes: Cu enrichment in bedrock at the source, likely during crystallization of the igneous silicates, and adsorption of Cu on Mn-oxides precipitated from groundwater that encountered oxidizing conditions within fractures in the bedrock. Finally, the potassic sediments enriched in copper may be evidence of a porphyry copper deposit or an impact-induced hydrothermal deposit in the source region.

58 GEOSCIENCES↗

On the Hunt for Detectable Biosignatures in Jezero Crater: What to Look for and Where

Introduction: The Perseverance rover, which is currently exploring Jezero crater on Mars, is equipped with seven instruments that allow for observation of textures, minerals, color, structure, and chemistry of rocks and sediments in order to search for signs of ancient life, understand the geologic history of the crater, and identify candidates for sample return (Farley et al. 2020). The first of these aims includes the direct detection of potential biosignatures, including textures, organic molecules, minerals, and elemental chemistries that are of biogenic origin (Mustard et al. 2013). The presence of these biosignatures will be constrained by the habitability of the local region, the preservation potential of the host rocks, and the sensitivity of the instrument suite, and their biogenicity will be investigated after return to Earth as part of the Mars Sample Return campaign. Here, we examine key targets on the three planned campaigns, potential biosignatures that may be present, and the capabilities of key rover instruments. High Potential Biosignature Sites in Jezero: To date, measurements have been made on multiple sites that both contain minerals known in terrestrial settings to preserve biosignatures and likely were habitable settings (Williford et al. 2021). Two examples include the fine-grained rocks at the base of the delta fan and the NW inner margin of the crater. Fine-grained Rocks at Base of Delta Fan. Fine-grained, clay-bearing rocks may have been deposited as muddy lake sediments that could have hosted life and preserved biosignatures settling out of the water column. The report of organic molecules by the Curiosity rover in the Sheepbed mudstone and Murray formation has highlighted this site in particular. Potential biosignatures in mudstones, especially those rich in silica (McMahon et al. 2018), microbialites and complex organics. NW Inner Margin of Crater. This unit, located along the inner margin of the crater, contains strong carbonate signatures and may have been the littoral zone of a lake (Horgan et al. 2020). The potential biosignatures here include microfossils, microbialites, biominerals, and complex organics. Detectability of Biosignatures by the Mars 2020 Instrument Suite: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument comprises a Deep UV spectrometer, context imager, and color camera to generate spatially resolved chemical maps (Bhartia et al. 2020). It is sensitive to trace organics as well as a range of minerals and can detect native fluorescence from aromatic organics; the WATSON and ACI cameras can be used to observe morphologies such as stromatolitic laminations or filaments ranging from the tens of micron to millimeter scale. SHERLOC can detect organics that may be present in either of the high potential biosignature targets, as well as detect carbonates in the latter. However, the presence of high amounts of iron, such as in iron-rich clays, would cause attenuation of spectral response through UV absorption. The Planetary Instrument for X-ray Lithochemistry (PIXL) comprises an X-ray fluorescence spectrometer and camera that can scan rock surfaces to generate elemental maps (Allwood et al. 2020). PIXL can detect chemical biosignatures such as spatial variations of elemental abundances that may have resulted from biological activity. PIXL would be particularly useful in detecting fine textures and elemental chemistries in either high potential biosignature target, but cannot directly detect minerals such as carbonate. The SuperCam instrument performs three types of spectroscopy, color imaging, and acoustic recording to remotely examine elemental composition, minerals, organics, and textures (Maurice et al. 2021). Using laser induced breakdown spectroscopy and time resolved luminescence spectroscopy, SuperCam can detect major elemental building blocks of organics (i.e., C, H, N, O, P, S) and conjugated organic structures, respectively, which may be found in either site. While in other contexts, luminescence is a useful tool for biosignature identification, luminescence generated by the 532 nm laser may obscure the Raman signal. Conclusion: The three instruments discussed can be used collaboratively to establish the presence of potential biosignatures in samples. These high-priority samples may then be returned to Earth for detailed laboratory analysis.

S. Sharma↗

The Stability of SiO{sub 2} Fe{sub 3}O{sub 4} Nanoparticles for Uranium Extraction in Acidic Media - 20189

This comprehensive study has shown that the proposed strategy of SiO{sub 2} coating of Fe{sub 3}O{sub 4} nanoparticles (NPs) for the use of uranium (U) extraction in acidic media was successful. The breakdown of Fe{sub 3}O{sub 4} in acidic media has proven to be a challenge when applying to a nuclear waste removal scenario, leading to the dissolution of Fe{sub 3}O{sub 4} and preventing uptake of U ions in the waste. To overcome this a SiO{sub 2} passivating layer was grafted to the Fe{sub 3}O{sub 4} NPs, to which an acid stability test was conducted between pH 3 and pH 4. It has been shown via Transmission Electron Microscopy (TEM) and zeta potential measurements that the uncoated Fe{sub 3}O{sub 4} NPs exhibit rapid coagulation when exposed to acidic conditions, moving from a stable zeta potential of -44 mV to an unstable zeta potential of +6 mV. SiO{sub 2} coated Fe{sub 3}O{sub 4} on the other hand can remain stable for several hours and continue to be stable beyond that. Throughout acid exposure the zeta potential of these NPs remained at ∼ -38 mV, showing great stability. As a functionality is needed on the surface of the NPs for separation and extraction, the phosphate complex used was also tested for its acid stability. It was determined that with a constant zeta potential of ∼ -20 mV, the phosphate functionality was able to remain stable in the acidic conditions simulating the environment of certain nuclear wastes. Overall SiO{sub 2} coated (PO)x-Fe{sub 3}O{sub 4} NPs show great promise for application in separation and removal of U in acid media. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microscopic Origins of the Nonlinear Behavior of Particle-Filled Rubber Probed with Dynamic Strain XPCS

The underlying microscopic response of filler networks in reinforced rubber to dynamic strain is not well understood due to the experimental difficulty of directly measuring filler network behavior in samples undergoing dynamic strain. This difficulty can be overcome with in situ X-ray photon correlation spectroscopy (XPCS) measurements. The contrast between the silica filler and the rubber matrix for X-ray scattering allows us to isolate the filler network behavior from the overall response of the rubber. This in situ XPCS technique probes the microscopic breakdown and reforming of the filler network structure, which are responsible for the nonlinear dependence of modulus on strain, known in the rubber science community as the Payne effect. These microscopic changes in the filler network structure have consequences for the macroscopic material performance, especially for the fuel efficiency of tire tread compounds. In this work, we elucidate the behavior with in situ dynamic strain XPCS experiments on industrially relevant, vulcanized rubbers filled (13 vol %) with novel air-milled silica of ultrahigh-surface area (UHSA) (250 m 2 /g). The addition of a silane coupling agent to rubber containing this silica causes an unexpected and counterintuitive increase in the Payne effect and decrease in energy dissipation. For this rubber, we observe a nearly two-fold enhancement of the storage modulus and virtually equivalent loss tangent compared to a rubber containing a coupling agent and conventional silica. Interpretation of our in situ XPCS results simultaneously with interpretation of traditional dynamic mechanical analysis (DMA) strain sweep experiments reveals that the debonding or yielding of bridged bound rubber layers is key to understanding the behavior of rubber formulations containing the silane coupling agent and high-surface area silica. These results demonstrate that the combination of XPCS and DMA is a powerful method for unraveling the microscale filler response to strain which dictates the dynamic mechanical properties of reinforced soft matter composites. With this combination of techniques, we have elucidated the great promise of UHSA silica when used in concert with a silane coupling agent in filled rubber. Such composites simultaneously exhibit large moduli and low hysteresis under dynamic strain.

36 MATERIALS SCIENCE↗

Development and Optical Testing of the Camera, Hand Lens, and Microscope Probe with Scannable Laser Spectroscopy (CHAMP-SLS)

Conducting high resolution field microscopy with coupled laser spectroscopy that can be used to selectively analyze the surface chemistry of individual pixels in a scene is an enabling capability for next generation robotic and manned spaceflight missions, civil, and military applications. In the laboratory, we use a range of imaging and surface preparation tools that provide us with in-focus images, context imaging for identifying features that we want to investigate at high magnification, and surface-optical coupling that allows us to apply optical spectroscopic analysis techniques for analyzing surface chemistry particularly at high magnifications. The camera, hand lens, and microscope probe with scannable laser spectroscopy (CHAMP-SLS) is an imaging/spectroscopy instrument capable of imaging continuously from infinity down to high resolution microscopy (resolution of approx. 1 micron/pixel in a final camera format), the closer CHAMP-SLS is placed to a feature, the higher the resultant magnification. At hand lens to microscopic magnifications, the imaged scene can be selectively interrogated with point spectroscopic techniques such as Raman spectroscopy, microscopic Laser Induced Breakdown Spectroscopy (micro-LIBS), laser ablation mass-spectrometry, Fluorescence spectroscopy, and/or Reflectance spectroscopy. This paper summarizes the optical design, development, and testing of the CHAMP-SLS optics.

Fluorescence↗

Multi-Point Line Focused Laser Differential Interferometer for High-Speed Flow Fluctuation Measurements

A multi-point focused laser differential interferometer (FLDI) has been developed to measure density fluctuations at 16 points along a line. A pair of cylindrical lenses on the transmitter side of a conventional single-point FLDI instrument form two closely spaced (≤200 μm), orthogonally polarized, parallel laser lines at the instrument’s focus. On the receiver side of the instrument, the interference of the beams on a 16-element photodiode array results in a single line of measurements. The further addition of a Nomarski prism creates two separate measurement lines, and the addition of a second photodiode array to the instrument enables simultaneous measurements of density fluctuations along the two lines separated by several millimeters. These two lines of measurement can be conveniently oriented at any azimuthal angle relative to the instrument’s optical axis on the measurement plane, coinciding with the instrument’s focus. Two experiments were performed to demonstrate the capabilities of the instrument. In the first experiment, a laser-induced breakdown spark generated a traveling spherical shock wave, and measurements of the resulting density disturbance and wave velocity were obtained. These results were compared to high-speed schlieren images of the shock wave acquired at 400 kHz. In the second experiment, the multi-point FLDI instrument was used to measure density disturbances in the boundary layer of a flat plate in a Mach 6 freestream flow. The measurements were made along two lines, both approximately 6 mm in length, extending from the surface of the plate through the boundary layer. High-speed schlieren images were acquired at 100 kHz during separate wind tunnel runs at matching unit Reynolds numbers to visualize the unsteady boundary layer flow and compare to the FLDI measurements.

Laser beam shaping↗