Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Long-Term Cr Poisoning Effect on LSCF-GDC Composite Cathodes Sintered at Different Temperatures

Here, the impact of sintering temperature on Cr-poisoning of solid oxide fuel cell (SOFC) cathodes was systematically studied. La 0.6 Sr 0.4 Fe 0.8 Co 0.2 O 3-δ - Ce 0.9 Gd 0.1 O 2-δ symmetric cells were aged at 750°C in synthetic air with the presence of Crofer 22 APU, a common high temperature interconnect, over 200 hours and electrochemical impedance spectroscopy (EIS) was used to determine the degradation process. Both the ohmic resistance (R Ω ) and polarization resistance (R P ) of LSCF-GDC cells, extracted from EIS spectra, for different sintering temperatures increase as a function of aging time. Furthermore, the Cr-related degradation rate increases with decreased cathode sintering temperature. The polarization resistance of cathode sintered at lower temperature (950°C) increases dramatically while aging with the presence of Cr and also significantly decreases the oxygen partial pressure dependence after aging. The degradation rate shows a positive correlation to the concentration of Cr. The results indicate that decreased sintering temperature increases the total surface area, leading to more available sites for Sr-Cr-O nucleation and thus greater Cr degradation.

30 DIRECT ENERGY CONVERSION↗

Hanford low-activity waste glass composition-temperature-melt viscosity relationships

This study developed a model for predicting viscosity of alkali-alumino-borosilicate glass melts as functions of composition and temperature. The model is based on a total of 3935 viscosity-temperature data from 574 glasses with viscosity values ranging from 2.53 to 7260 Poise (P) in the temperature range of 900–1260°C. Several different model forms were surveyed, including those based on Arrhenius, Vogel-Fulcher-Tammann, Avramov-Milchev, and Mauro-Yue-Ellison-Gupta-Allen. For each of these models, combinations of the temperature-independent parameters were fitted to composition. It was found that generally fitting more than one temperature-independent parameter as functions of composition resulted in overfitting. The Avramov-Milchev-based model was found to best represent the Hanford low-activity waste glass melt viscosity data based on model fit and validation statistics. A 21-term partial quadratic mixture model was recommended for use. This model predicts melt viscosity with a root-mean square error of .1736 ln(P), which is similar to the error in viscosity measurements from replicate glass analyses of .1383 ln(P). Viscosity was found to be most increased by SiO 2 > Al 2 O 3 > ZrO 2 > SnO 2 and most decreased by Li 2 O > Na 2 O > B 2 O 3 > CaO > K 2 O > MgO, at temperatures from 900 to 1260°C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Merging high resolution geophysical and geochemical surveys to reduce exploration risk at glass buttes, Oregon

The engineering and studies phase of the Glass Buttes project was aimed at reducing risk during the early stages of geothermal project development. The project’s inclusion of high resolution geophysical and geochemical surveys allowed Ormat to evaluate the value of these surveys both independently and in combination to quantify the most valuable course of action for exploration in an area where structure, permeability, and temperature are the most pressing questions. The sizes of the thermal anomalies at Glass Buttes are unusually large. Over the course of Phase I Ormat acquired high resolution LIDAR data to accurately map fault manifestations at the surface and collected detailed gravity and aeromagnetic surveys to map subsurface structural features. In addition, Ormat collected airborne hyperspectral data to assist with mapping the rock petrology and mineral alteration assemblages along Glass Buttes faults and magnetotelluric (MT) survey to try to better constrain the structures at depth. Direct and indirect identification of alteration assemblages reveal not only the geochemical character and temperature of the causative hydrothermal fluids but can also constrain areas of upflow along specific fault segments. All five datasets were merged along with subsurface lithologies and temperatures to predict the most likely locations for high permeability and hot fluids. The Glass Buttes temperature anomalies include 2 areas, totaling 60 km2 (23 mi2) of measured temperature gradients over 165° C/km (10° F/100ft). The Midnight Point temperature anomaly includes the Strat-1 well with 90°C (194 °F) at 603 m (1981 ft) with a 164 °C/km (10°F/100ft) temperature gradient at bottom hole and the GB-18 well with 71°C (160 °F) at 396 m (1300 ft) with a 182°C/km (11°F/100ft) gradient. The primary area of alteration and elevated temperature occurs near major fault intersections associated with Brothers Fault Zone and Basin and Range systems. Evidence for faulting is observed in each data set as follows. Field observations include fault plane orientations, complicated fault intersections, and hydrothermal alteration apparently pre-dating basalt flows. Geophysical anomalies include large, linear gradients in gravity and aeromagnetic data with magnetic lows possibly associated with alteration. Resistivity low anomalies also appear to have offsets associated with faulting. Hyperspectral and XRF identified alteration and individual volcanic flow units, respectively. When incorporated into a 3D geologic model, the fault intersections near the highest proven temperature and geophysical anomalies provide the first priority targets at Midnight Point. Ormat geologists selected the Midnight Point 52-33 drilling target based on a combination of pre-existing drilling data, geologic field work, geophysical interpretation, and geochemical analysis. Deep temperatures of well 52-33 was lower than anticipated. Temperature gradients in the well mirrored those found in historical drilling, but they decreased below 1500 ft and were isothermal below 2000 ft.

15 GEOTHERMAL ENERGY↗

Emissions from carpet combustion in a pilot-scale rotary kiln: comparison with coal and particle-board combustion

The use of post-consumer carpet as a potential fuel substitute in cement kilns and other high-temperature processes is being considered to address the problem of huge volumes of carpet waste and the opportunity of waste-to-energy recovery. Carpet represents a high volume waste stream, provides high energy value, and contains other recoverable materials for the production of cement. This research studied the emission characteristics of burning 0.46-kg charges of chopped nylon carpet squares, pulverized coal, and particle-board pellets in a pilot-scale natural gas-fired rotary kiln. Carpet was tested with different amounts of water added. Emissions of oxygen, carbon dioxide, nitric oxide (NO), sulfur dioxide (SO{sub 2}), carbon monoxide (CO), and total hydrocarbons and temperatures were continuously monitored. It was found that carpet burned faster and more completely than coal and particle board, with a rapid volatile release that resulted in large and variable transient emission peaks. NO emissions from carpet combustion ranged from 0.06 to 0.15 g/MJ and were inversely related to CO emissions. Carpet combustion yielded higher NO emissions than coal and particleboard combustion, consistent with its higher nitrogen content. S{sub 2} emissions were highest for coal combustion, consistent with its higher sulfur content than carpet or particle board. Adding water to carpet slowed its burn time and reduced variability in the emission transients, reducing the CO peak but increasing NO emissions. Results of this study indicate that carpet waste can be used as an effective alternative fuel, with the caveats that it might be necessary to wet carpet or chop it finely to avoid excessive transient puff emissions due to its high volatility compared with other solid fuels, and that controlled mixing of combustion air might be used to control NO emissions from nylon carpet. 13 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Rocket measurements of conjugate photoelectrons during the total solar eclipse of 7 March 1970 over Wallops Island.

Results of measurements made with a retarding potential analyzer on a Nike-Tomahawk rocket during the totality of the solar eclipse, showing definite evidence for the existence of photoelectrons from the conjugate hemisphere. Photoelectrons are observed in the altitude range from 120 to 260 km. The observed flux in the energy range from 2 to 30 eV is relatively constant above about 200 km, but decreased below that altitude. The flux of 5-eV energy electrons above 200 km altitude is about 10 to the 7th power electrons/cm/sec/eV. Higher-energy electrons were also observed, and it is possible that the energy content of these observed fluxes of conjugate-point photoelectrons is sufficient to maintain the observed electron densities and temperatures during the total eclipse.

Maier, E. J.↗

Yakima River Basin Temporal Study: Sensor and Sample Data from Wenas Creek following the Evans Canyon Fire in Washington, USA

The Evans Canyon Fire occurred in Washington in August 2020 and burned 76,000 acres of the semi-arid shrub-steppe landscape at low to moderate severities. This fire burned across the Wenas Creek watershed, allowing for a sampling design that included a portion of the stream within the burned area and a reference site upstream of the burn. Monthly data was collected at an unburned (W10) and burned (W20) site from November 2020 to August 2022 for in situ hydrological and water chemistry sensor data, handheld sensor water chemistry data, general environmental context photos, and field metadata. This dataset is comprised of one folder with field photos and one main data folder containing (1) sensor and sample field protocols; (2) file-level metadata (flmd); (3) data dictionary (dd); (4) international geo-sample number (IGSN) mapping file; (5) field metadata; (6) readme; (7) methods codes; (8) dissolved organic carbon (DOC; measured as non-purgeable organic carbon; NPOC); (9) total nitrogen (TN); (10) total suspended solids (TSS); (11) sensor data (specific conductance, pH, total dissolved solids, temperature, pressure, dissolved oxygen, and turbidity) averages; and (12) sensor installation methods. All files are .csv, .jpg, .jpeg, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

Prospects and Limitations of Predicting Fuel Ignition Properties from Low-Temperature Speciation Data

Using chemical kinetic modeling and statistical analysis, we investigate the possibility of correlating key chemical “markers”–typically small molecules–formed during very lean (φ ~ 0.001) oxidation experiments with near-stoichiometric (φ ~ 1) fuel ignition properties. One goal of this work is to evaluate the feasibility of designing a fuel-screening platform, based on small laboratory reactors that operate at low temperatures and use minimal fuel volume. Buras et al. [Combust. Flame2020,216, 472–484] have shown that convolutional neural net (CNN) fitting can be used to correlate first-stage ignition delay times (IDTs) with OH/HO2 measurements during very lean oxidation in low-T flow reactors with better than factor-of-2 accuracy. In this work, we test the limits of applying this correlation-based approach to predict the low-temperature heat release (LTHR) and total IDT, including the sensitivity of total IDT to the equivalence ratio, φ. We demonstrate that first-stage IDT can be reliably correlated with very lean oxidation measurements using compressed sensing (CS), which is simpler to implement than CNN fitting. LTHR can also be predicted via CS analysis, although the correlation quality is somewhat lower than for first-stage IDT. In contrast, the accuracy of total IDT prediction at φ = 1 is significantly lower (within a factor of 4 or worse). Furthermore, these results can be rationalized by the fact that the first-stage IDT and LTHR are primarily determined by low-temperature chemistry, whereas total IDT depends on low-, intermediate-, and high-temperature chemistry. Oxidation reactions are most important at low temperatures, and therefore, measurements of universal molecular markers of oxidation do not capture the full chemical complexity required to accurately predict the total IDT even at a single equivalence ratio. As a result, we find that φ-sensitivity of ignition delay cannot be predicted at all using solely correlation with lean low-T chemical speciation measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Regulation of CO 2 Activation Pathways via Interfacial Water Restructuring Enables Ampere-Level, Near-Unity CO Electrosynthesis

Electrochemical reduction of CO 2 to CO is a key step in carbon utilization technologies, yet maintaining high CO selectivity under elevated temperatures relevant to industrial membrane-electrode-assembly (MEA) electrolyzers remains challenging due to the competing hydrogen evolution reaction (HER). Additionally, the temperature dependence of CO selectivity on Cu-based catalysts has remained largely unexplored. Here, we demonstrate that incorporating atomic In or Sn into Cu fundamentally reshapes the selectivity of Cu catalysts at elevated temperatures. Dilute alloy catalysts, In 1 Cu and Sn 1 Cu, achieve >95% FE of CO over a broad current-density window (0.1−1.1 A cm −2 ) at 60 °C in MEA electrolyzers, far exceeding their performance at ambient temperature. In situ attenuated total reflection surface-enhanced infrared absorption spectroscopy suggests that elevating temperature depletes interfacial water activity, which favors a shift in CO 2 activation from a proton-coupled *COOH pathway toward an electron-driven *COO − -associated pathway, while also suppressing HER and CO hydrogenation. In contrast, benchmark CO-selective catalysts such as Ag exhibit minimal temperature-induced changes in CO production at 20−60 °C. These findings identify temperature as an unavoidable yet previously underutilized operating parameter in MEA electrolyzers for high-rate, selective CO production on Cubased catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photocatalytic post-treatment in waste water reclamation systems

A photocatalytic water purification process is described which effectively oxidizes organic impurities common to reclaimed waste waters and humidity condensates to carbon dioxide at ambient temperatures. With this process, total organic carbon concentrations below 500 ppb are readily achieved. The temperature dependence of the process is well described by the Arrhenius equation and an activation energy barrier of 3.5 Kcal/mole. The posttreatment approach for waste water reclamation described here shows potential for integration with closed-loop life support systems.

Cooper, Gerald↗

Temperature Crosstalk Sensitivity of the Kummerow Rainfall Algorithm

Even though the signal source for passive microwave retrievals is thermal emission, retrievals of non-temperature geophysical parameters typically do not explicitly take into account the effects of temperature change on the retrievals. For global change research, changes in geophysical parameters (e.g. water vapor, rainfall, etc.) are referenced to the accompanying changes in temperature. If the retrieval of a certain parameter has a cross-talk response from temperature change alone, the retrievals might not be very useful for climate research. We investigated the sensitivity of the Kummerow rainfall retrieval algorithm to changes in air temperature. It was found that there was little net change in total rainfall with air temperature change. However, there were non-negligible changes within individual rain rate categories.

Spencer, Roy W.↗

Advanced Hydrogen Turbine Development

Siemens has developed a roadmap to achieve the DOE goals for efficiency, cost reduction, and emissions through innovative approaches and novel technologies which build upon worldwide IGCC operational experience, platform technology, and extensive experience in G-class operating conditions. In Phase 1, the technologies and concepts necessary to achieve the program goals were identified for the gas turbine components and supporting technology areas and testing plans were developed to mitigate identified risks. Multiple studies were conducted to evaluate the impact in plant performance of different gas turbine and plant technologies. 2015 gas turbine technologies showed a significant improvement in IGCC plant efficiency, however, a severe performance penalty was calculated for high carbon capture cases. Thermodynamic calculations showed that the DOE 2010 and 2015 efficiency targets can be met with a two step approach. A risk management process was instituted in Phase 1 to identify risk and develop mitigation plans. For the risks identified, testing and development programs are in place and the risks will be revisited periodically to determine if changes to the plan are necessary. A compressor performance prediction has shown that the design of the compressor for the engine can be achieved with additional stages added to the rear of the compressor. Tip clearance effects were studied as well as a range of flow and pressure ratios to evaluate the impacts to both performance and stability. Considerable data was obtained on the four candidate combustion systems: diffusion, catalytic, premix, and distributed combustion. Based on the results of Phase 1, the premixed combustion system and the distributed combustion system were chosen as having the most potential and will be the focus of Phase 2 of the program. Significant progress was also made in obtaining combustion kinetics data for high hydrogen fuels. The Phase 1 turbine studies indicate initial feasibility of the advanced hydrogen turbine that meets the aggressive targets set forth for the advanced hydrogen turbine, including increased rotor inlet temperature (RIT), lower total cooling and leakage air (TCLA) flow, higher pressure ratio, and higher mass flow through the turbine compared to the baseline. Maintaining efficiency with high mass flow Syngas combustion is achieved using a large high AN2 blade 4, which has been identified as a significant advancement beyond the current state-of-the-art. Preliminary results showed feasibility of a rotor system capable of increased power output and operating conditions above the baseline. In addition, several concepts were developed for casing components to address higher operating conditions. Rare earth modified bond coat for the purpose of reducing oxidation and TBC spallation demonstrated an increase in TBC spallation life of almost 40%. The results from Phase 1 identified two TBC compositions which satisfy the thermal conductivity requirements and have demonstrated phase stability up to temperatures of 1850 C. The potential to join alloys using a bonding process has been demonstrated and initial HVOF spray deposition trials were promising. The qualitative ranking of alloys and coatings in environmental conditions was also performed using isothermal tests where significant variations in alloy degradation were observed as a function of gas composition. Initial basic system configuration schematics and working system descriptions have been produced to define key boundary data and support estimation of costs. Review of existing materials in use for hydrogen transportation show benefits or tradeoffs for materials that could be used in this type of applications. Hydrogen safety will become a larger risk than when using natural gas fuel as the work done to date in other areas has shown direct implications for this type of use. Studies were conducted which showed reduced CO{sub 2} and NOx emissions with increased plant efficiency. An approach to maximize plant output is needed in order to address the DOE turbine goal for 20-30% reduction of combined cycle cost from the baseline. A customer advisory board was instituted during Phase 1 to obtain important feedback regarding the future direction of the project. he technologies being developed for the Hydrogen Turbine will also be utilized, as appropriate, in the 2010 time frame engine and the FutureGen Plant. These new technologies and concepts also have the potential to accelerate commercialization of advanced coal-based IGCC plants in the U. S. and around the world, thereby reducing emissions, water use, solid waste production and dependence on scarce, expensive and insecure foreign energy supplies. Technology developments accomplished in Phase 1 provide a solid foundation for ensuring successful completion in Phase 2 and providing that the challenging program goals will be achieved.

03 NATURAL GAS↗

Special observations

The wind or temperature profiler is a new special observation device designed to supplement traditional atmospheric measurement and provide more accurate middle-range forecasts, including aviation and space applications. Radar is most useful in the short, nowcast time frame. Satellites and surface observations are also most useful for short-range forecasts but have less impact on the longer range. The radiosonde network, on the other hand, only starts to be very important after about six hours and has greatest impact at lead times of 12 hours or more. In the wind profiler, wind is measured by using clear-air Doppler radar principles, Two fixed beams, pointing 15 deg to the north and 15 deg to the east, sense the Doppler shift. The resulting wind vectors are then rotated to the horizontal and combined to give total wind. The temperature profiler measures temperature and humidity by using passive radiometers. Development on the profiler is 95 percent complete, and on the temperature profiler 75 percent complete.

Beran, Donald↗

Ion Temperature and Hydrodynamic-Energy Measurements in a Z-Pinch Plasma at Stagnation

The time history of the local ion kinetic energy in a stagnating plasma was determined from Doppler-dominated line shapes. Using independent determination of the plasma properties for the same plasma region, the data allowed for inferring the time-dependent ion temperature, and for discriminating the temperature from the total ion kinetic energy. It is found that throughout most of the stagnation period the ion thermal energy constitutes a small fraction of the total ion kinetic energy; the latter is dominated by hydrodynamic motion. Both the ion hydrodynamic and thermal energies are observed to decrease to the electron thermal energy by the end of the stagnation period. It is confirmed that the total ion kinetic energy available at the stagnating plasma and the total radiation emitted are in balance, as obtained in our previous experiment. The dissipation time of the hydrodynamic energy thus appears to determine the duration (and power) of the K emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid fragility maximum in lithium borate glass‐forming melts related to the local structure

Abstract The structure of liquid lithium pyroborate, Li 4 B 2 O 5 ( J = Li/B = 2), has been measured over a wide temperature range by high‐energy X‐ray diffraction, and compared to that of its glass and borate liquids of other compositions. The results indicate a gradual increase in tetrahedral boron fraction from 3(1)% to 6(1)% during cooling from T = 1271(15) to 721(8) K, consistent with the larger N 4 = 10(1)% found for the glass, and literature 11 B nuclear magnetic resonance measurements. van't Hoff analysis based on a simple boron isomerization reaction BØ 3 O 2 – ⇌ BØO 2 2– yields Δ H = 13(1) kJ mol –1 and Δ S = 40(1) J mol –1 K –1 for the boron coordination change from 4 to 3, which are, respectively, smaller and larger than found for singly charged isomers for J ≤ 1. With these, we extend our model for N 4 ( J , T ), nonbridging oxygen fraction f nbr ( J , T ), configurational heat capacity , and entropy S conf ( J , T ) contributions up to J = 3. A maximum is revealed in at J = 1, and shown semi‐quantitatively to lead to a corresponding maximum in fragility contribution, akin to that observed in the total fragilities by temperature‐modulated differential scanning calorimetry. Lithium is bound to 4.6(2) oxygen in the pyroborate liquid, with 2.7(1) bonds centered around 1.946(8) Å and 1.9(1) around 2.42(1) Å. In the glass, n LiO = 5.4(4), the increase being due to an increase in the number of short Li–O bonds.

36 MATERIALS SCIENCE↗

Electrostatic contribution from solvent in modulating single-walled carbon nanotube association

We perform all-atom molecular dynamics simulations to compute the potential of mean force (PMF) between two (10,10) single-walled carbon nanotubes solvated in pure nonpolarizable SPC/E and polarizable TIP4P-FQ water, at various temperatures. In general, the reversible work required to bring two nanotubes from a dissociated state (free energy reference) to contact state (free energy minimum) is more favorable and less temperature-dependent in TIP4P-FQ than in SPC/E water models. In contrast, molecular properties and behavior of water such as the spatially-resolved water number density (intertube, intratube, or outer regions), for TIP4P-FQ are more sensitive to temperature than SPC/E. Decomposition of the solvent-induced PMF into different spatial regions suggests that TIP4P-FQ has stronger temperature dependence; the opposing destabilizing/stabilizing contributions from intertube water and more distal water balance each other and suppress the temperature dependence of total association free energy. Further investigation of hydrogen bonding network in intertube water reveals that TIP4P-FQ retains fewer hydrogen bonds than SPC/E, which correlates with the lower water number density in this region. This reduction of hydrogen bonds affects the intertube water dipoles. As the intertube volume decreases, TIP4P-FQ dipole moment approaches the gas phase value; the distribution of dipole magnitude also becomes narrower due to less average polarization/perturbation from other water molecules. Our results imply that the reduction of water under confinement may seem trivial, but underlying effects to structure and free energetics are non-negligible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lunar base heat pump, phase 1

This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were analyzed in ideal single and two-stage thermodynamic cycles. Top candidates were analyzed assuming realistic component limits and system pressure drops, and were evaluated for other considerations such as safety, environmental impact, and commercial availability. A maximum coefficient of performance (COP) of 56 percent of the Carnot ideal was achievable for a three-stage CFC-11 cycle operating under the flight conditions above. The program was completed by defining a control scheme and by researching and selecting the major components, compressor and heat exchangers, that could be used to implement the thermodynamic cycle selected. Special attention was paid to using similar technologies for the SIRF and flight heat pumps resulting in the commercially available equivalent of the flight unit. A package concept was generated for the components selected and mass and volume estimated.

Goldman, Jeffrey H.↗

Comparison of Fission Product Release Predictions using PARFUME and BISON with Results from the AGR-3/4 Irradiation Experiment

The PARFUME (PARticle Fuel ModEl) fuel performance modeling code and the BISON nuclear fuel performance application built on the Multiphysics Object-Oriented Simulation Environment (MOOSE) finite element library were used to predict the fission product release from tristructural isotropic (TRISO) coated fuel particles and compacts during the third and fourth irradiation experiment of the Advanced Gas Reactor (AGR-3/4) Fuel Development and Qualification Program. The fuel performance modeling codes PARFUME and BISON modeled the AGR-3/4 irradiation experiment using the fuel compact time-averaged volume averaged (TAVA) daily temperatures for a total irradiation duration of 369.1 effective full power days (EFPD) to predict the release fraction of the fission product silver (Ag-110m) from a representative TRISO-coated fuel particle from AGR-3/4 compacts. Post-irradiation examination (PIE) measurements provided data on the release of these fission products in the compacts outside of the silicon carbide (SIC) layer. The PARFUME and BISON results were then compared to the silver release measured from compact gamma scanning. The results showed good agreement between PARFUME and BISON but both codes under-predicted the silver release fraction for all the compacts. In addition, BISON was used to model and predict the fission product concentration radial profile outside of the compacts in capsules’ inner and outer rings. These rings were either comprised of matrix and/or structural graphite. To obtain the concentration profiles of silver, cesium, and strontium, a sorption isotherm model was developed in BISON to capture the effects of fission product transport across the gaps between the concentric rings. The general shape of the concentration radial profiles as calculated by BISON were similar in the inner ring (IR) but varied in the outer ring (OR) depending on the fission product of interest or capsule temperature. Using this methodology and model, BISON now has the capability to aid in developing new fission product diffusion coefficients for matrix or structural graphite materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗