Search NASA⌕ Search

SEARCH · Search NASA

Results for “validation data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

WE-H-207B-00: MRgRT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-01: Commissioning and QC

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-02: MR-Driven RT Planning

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-03: MRI Guidance in the Radiation Therapy Clinic: Site-Specific Discussions

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-04: Strategies for Adaptive RT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

Accelerated discovery of metallic glasses through iteration of machine learning and high-throughput experiments

With more than a hundred elements in the periodic table, a large number of potential new materials exist to address the technological and societal challenges we face today; however, without some guidance, searching through this vast combinatorial space is frustratingly slow and expensive, especially for materials strongly influenced by processing. We train a machine learning (ML) model on previously reported observations, parameters from physiochemical theories, and make it synthesis method–dependent to guide high-throughput (HiTp) experiments to find a new system of metallic glasses in the Co-V-Zr ternary. Experimental observations are in good agreement with the predictions of the model, but there are quantitative discrepancies in the precise compositions predicted. We use these discrepancies to retrain the ML model. The refined model has significantly improved accuracy not only for the Co-V-Zr system but also across all other available validation data. We then use the refined model to guide the discovery of metallic glasses in two additional previously unreported ternaries. Although our approach of iterative use of ML and HiTp experiments has guided us to rapid discovery of three new glass-forming systems, it has also provided us with a quantitatively accurate, synthesis method–sensitive predictor for metallic glasses that improves performance with use and thus promises to greatly accelerate discovery of many new metallic glasses. We believe that this discovery paradigm is applicable to a wider range of materials and should prove equally powerful for other materials and properties that are synthesis path–dependent and that current physiochemical theories find challenging to predict.

36 MATERIALS SCIENCE↗

Tulane virus protease as a structural surrogate for inhibitor screening of human norovirus proteases

Human norovirus (HuNoV) is a significant cause of gastroenteritis worldwide, affecting people of all age groups. There are currently no vaccines or drugs available, leaving susceptible populations vulnerable to severe or protracted illness. A HuNoV cultivation system is pivotal for screening norovirus antivirals. While the human intestinal enteroid cultivation system allows robust replication of multiple HuNoV strains, it presents technical and cost barriers. Tulane virus (TV), a surrogate for HuNoV, replicates well in monkey kidney cell lines and is closely related to norovirus in cellular biology. Here, we determined the structures of TV protease (TV-Pro) alone and in complex with rupintrivir, a picornavirus inhibitor that also inhibits HuNoV proteases (HuNoV-Pro). Our data validate TV as an efficient surrogate system for rapid screening of HuNoV protease inhibitors. The TV protease structure exhibits significant backbone similarity to the GI.1 HuNoV protease in the substrate-binding domain, with the BII-CII loop in an open conformation stabilized by hydrogen bonds as present in the GI.1 protease. Structural differences in the S2 pocket and two amino acid changes in the S4 pocket result in slightly altered P2 and P4 substrate and inhibitor conformations. Despite these differences, we confirm previous findings that the TV protease can cleave the GI.1 and GII HuNoV polyprotein substrates with high and moderate efficiency, respectively. We found that rupintrivir efficiently inhibits TV protease in vitro and inhibits TV replication in cell culture with similar efficacy in combination with P-glycoprotein efflux pump inhibitors. We conclude that TV is a valuable surrogate for HuNoV protease inhibitor screening and outline strategies to improve its compatibility as such.

crystal structures↗

Machine learning based design space exploration for hybrid main-memory design

We develop a machine learning (ML) based design space exploration (DSE) method that builds predictive models for various responses of a hybrid main-memory system. To overcome the challenges associated with latency, capacity, and power of memory systems in future extreme-scale machines, the hybrid memory architectures are being considered in which novel non-volatile memory (NVM) systems augment the traditional DRAM. However, way before their actual design and implementation, these emerging hybrid memory systems need to be simulated and analyzed to fully understand their capabilities and limitations. As the conventional architectural-level memory simulators require significant amounts of computational costs and time, we propose to utilize ML techniques for developing various memory-response models that can instantly provide a predicted response corresponding to any new memory configuration. Specifically, in this work, we apply four supervised ML techniques to build regression models for memory latency, bandwidth, power, and total read/write responses. The training and validation data for the ML methods are generated using NVMain memory simulator for DRAM, NVM, and their hybrid combinations. We demonstrate the results of the ML based memory-DSE method in terms of the learning curve characteristics for hyperparameter tuning and the statistical error analyses of the designed predictive models.

Sen, Satyabrata↗

Adapting CLUTCH methodology to multigroup TSUNAMI-3D for eigenvalue sensitivity calculations

The sensitivity of the eigenvalue to uncertainties in nuclear data and its evaluation are important for nuclear criticality safety. TSUNAMI-3D sequences within the SCALE code system offer several options to the user community for calculating eigenvalue sensitivity coefficients with multigroup (MG) and continuous energy (CE) 3D transport capabilities. TSUNAMI-3D sequences implement the adjoint-based perturbation theory with MG KENO code, the Contributon Linked eigenvalue sensitivity/Uncertainty estimation via Track length importance CHaracterization (CLUTCH) method with CE KENO code, and the Iterated Fission Probability (IFP) method with CE KENO and Shift codes. Each method has benefits and limitations depending on the problem that is run. The work presented here aims to adapt the CLUTCH method, which enables the Contributon method's mesh-free, memory-efficient approach for calculating adjoint-weighted tallies for sensitivity calculations, to the MG TSUNAMI-3D sequence. This application would eliminate the explicit adjoint KENO calculation, as well as the memory-consuming mesh flux moment tallies required by the conventional MG TSUNAMI-3D. Smaller memory footprints in the CLUTCH methodology and relatively shorter runtimes in MG KENO transport can make MG TSUNAMI-3D a viable method for some complex problems. Moreover, this adaptation allows MG sensitivity calculations with Shift, ORNL's next-generation high-performance Monte Carlo transport code, which currently does not offer any sensitivity capabilities with MG particle transport simulations. Initial implementation of the new MG TSUNAMI-3D sequence and its preliminary results with a selected critical benchmark experiment in the Verified, Archived Library of Inputs and Data (VALID) are presented in this study.

KENO↗

Statistical Simulation of the Performance and Degradation of a PEMFC Membrane Electrode Assembly

A 1-D MEA Performance model was developed that considered transport of liquid water, agglomerate catalyst structure, and the statistical variation of the MEA characteristic parameters. The model was validated against a low surface area carbon supported catalyst across various platinum loadings and operational conditions. The statistical variation was found to play a significant role in creating noise in the validation data and that there was a coupling effect between movement in material properties with liquid water transport. Further, in studying the low platinum loaded catalyst layers it was found that liquid water played a significant role in the increasing the overall transport losses. The model was then further applied to study platinum dissolution via potential cycling accelerated stress tests, in which the platinum was found to dissolve nearest the membrane effectively resulting in reaction distribution shifts within the layer.

08 HYDROGEN↗

Clearance Tracker

The manual process of managing security clearance was cumbersome and inefficient, involving the emailing of a fillable PDF from person to person. There was no visibility into the progress of a clearance submission. Clearance Tracker provides an automated workflow with data validation and notifications to manage the clearance process. The automated workflow routes notifications to individuals when their input is required. All participants can track the progress of clearance requests.

Short, RickyD↗

A Representative Democracy to Reduce Interdependency in a Multimodel Ensemble

The collection of Earth system models available in the archive of phase 5 of CMIP (CMIP5) represents, at least to some degree, a sample of uncertainty of future climate evolution. The presence of duplicated code as well as shared forcing and validation data in the multiple models in the archive raises at least three potential problems: biases in the mean and variance, the overestimation of sample size, and the potential for spurious correlations to emerge in the archive because of model replication. Analytical evidence is presented to demonstrate that the distribution of models in the CMIP5 archive is not consistent with a random sample, and a weighting scheme is proposed to reduce some aspects of model codependency in the ensemble. A method is proposed for selecting diverse and skillful subsets of models in the archive, which could be used for impact studies in cases where physically consistent joint projections of multiple variables (and their temporal and spatial characteristics) are required.

54 ENVIRONMENTAL SCIENCES↗

Two-Stream Multi-Channel Convolutional Neural Network for Multi-Lane Traffic Speed Prediction Considering Traffic Volume Impact

Traffic speed prediction is a critically important component of intelligent transportation systems. Recently, with the rapid development of deep learning and transportation data science, a growing body of new traffic speed prediction models have been designed that achieved high accuracy and large-scale prediction. However, existing studies have two major limitations. First, they predict aggregated traffic speed rather than lane-level traffic speed; second, most studies ignore the impact of other traffic flow parameters in speed prediction. To address these issues, the authors propose a two-stream multi-channel convolutional neural network (TM-CNN) model for multi-lane traffic speed prediction considering traffic volume impact. In this model, the authors first introduce a new data conversion method that converts raw traffic speed data and volume data into spatial–temporal multi-channel matrices. Then the authors carefully design a two-stream deep neural network to effectively learn the features and correlations between individual lanes, in the spatial–temporal dimensions, and between speed and volume. Accordingly, a new loss function that considers the volume impact in speed prediction is developed. A case study using 1-year data validates the TM-CNN model and demonstrates its superiority. This paper contributes to two research areas: (1) traffic speed prediction, and (2) multi-lane traffic flow study.

97 MATHEMATICS AND COMPUTING↗

Linear system identification of a cold flow circulating fluidized bed

Knowledge of the solids circulation rate (SCR) is essential to the control and improved performance of a circulating fluidized bed system. In the present work, the noise model is derived using the prediction error method considering process and measurement noises acting on the cold flow circulating fluidized bed (CFCFB) with a cork particulate material. The outputs of the initial model are the total pressure drop across the riser, the pressure drop across the crossover, the pressure drop across the primary cyclone, the total pressure drop across the stand-pipe, the pressure drop across the loop seal, and the SCR. The stochastic estimate of SCR is determined from the noise model using the stochastic pressure drop estimates. The deterministic estimate is obtained through the inputs taken as move air flow, riser aeration, and loop seal fluidization air that are all independent variables of the given setup and under the control of the user. The theory has been developed to convert a complete blackbox model to a grey box model through the output-to-state transformation such that both the models of the CFCFB consists of all these output variables as the states of the system, and only pressure drops across the system as the output measurements. Thus, the final models do not include any fictitious terms and they are defined only in terms of physical parameters of the given system. Both components of SCR are separately analysed. The combined SCR response of both the noise model and deterministic model is compared with the validation data set of this state variable in terms of modelfit, and the results are shown.

42 ENGINEERING↗

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the Initial Implementation of the Shift Monte Carlo Code in SCALE 6.3

The Shift Monte Carlo code will be introduced in SCALE 6.3 as an alternative to the KENO V.a, KENO-VI, and Monaco codes. Calculations were performed to establish the performance of Shift for criticality safety analyses within the criticality safety analyses sequence (CSAS) based on models in the Verified, Archived Library of Inputs and Data (VALID). This test suite contains over 600 critical experiment models covering a broad range of fissile materials and neutron energy spectra. The comparisons presented include calculated k eff values and runtime performance for serial calculations and a selection of parallel calculations. Comparisons are presented for multigroup (MG) and continuous-energy (CE) calculations for KENO V.a and KENO-VI models. Results generated with a beta version of SCALE 6.3 indicate excellent agreement in k eff values between KENO and Shift. The largest differences in the average k eff value calculated for the 15 categories of KENO V.a models are 0.00020 ± 0.00011 Δ k for MG calculations and 0.00011 ± 0.00005 Δ k for CE calculations. Similar comparisons in three categories using KENO-VI result in the largest differences for MG calculations: as 0.00004 ± 0.00003 Δ k , and -0.00002 ± 0.00003 Δ k for CE. The preliminary results also indicate that Shift is faster than KENO on a per particle basis, especially for fast spectrum systems. The uncertainty per history is also higher, however, so the Monte Carlo figure of merit is higher for KENO for thermal and intermediate spectrum systems. As expected, Shift generally has better speedup than KENO for parallel calculations, regardless of neutron energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Completion of Surrogate Testing for Low-Temperature TEX and a Look Towards the Future

To address the mounting need for below room temperature nuclear data validation, the Low-Temperature Thermal Epithermal eXperiments (LT-TEX) have been designed. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A single inactivating amino acid change in the SARS-CoV-2 NSP3 Mac1 domain attenuates viral replication in vivo

Despite unprecedented efforts, our therapeutic arsenal against SARS-CoV-2 remains limited. The conserved macrodomain 1 (Mac1) in NSP3 is an enzyme exhibiting ADP-ribosylhydrolase activity and a possible drug target. To determine the role of Mac1 catalytic activity in viral replication, we generated recombinant viruses and replicons encoding a catalytically inactive NSP3 Mac1 domain by mutating a critical asparagine in the active site. While substitution to alanine (N40A) reduced catalytic activity by ~10-fold, mutations to aspartic acid (N40D) reduced activity by ~100-fold relative to wild-type. Importantly, the N40A mutation rendered Mac1 unstable in vitro and lowered expression levels in bacterial and mammalian cells. When incorporated into SARS-CoV-2 molecular clones, the N40D mutant only modestly affected viral fitness in immortalized cell lines, but reduced viral replication in human airway organoids by 10-fold. In mice, the N40D mutant replicated at >1000-fold lower levels compared to the wild-type virus while inducing a robust interferon response; all animals infected with the mutant virus survived infection. Our data validate the critical role of SARS-CoV-2 NSP3 Mac1 catalytic activity in viral replication and as a promising therapeutic target to develop antivirals.

60 APPLIED LIFE SCIENCES↗