Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

INTEGRAL Long-Term Monitoring of the Supergiant Fast X-Ray Transient XTE J1739-302

Context. In the past few years, a new class of High Mass X-Ray Binaries (HMXRB) has been claimed to exist, the Supergiant Fast X-ray Transients (SFXT). These are X-ray binary systems with a compact companion orbiting a supergiant star which show very short and bright outbursts in a series of activity periods overimposed on longer quiescent periods. Only very recently the first attempts to model the behaviour of these sources have been published, some of them within the framework of accretion from clumpy stellar winds. Aims. Our goal is to analyze the properties of XTE J1739-302/IGR J17391-3021 within the context of the clumpy structure of the supergiant wind. Methods. We have used INTEGRAL and RXTE/PCA observations in order to obtain broad band (1 - 200 keV) spectra and light curves of XTE J1739-302 and investigate its X-ray spectrum and temporal variability. Results. We have found that XTE J1739-302 follows a much more complex behaviour than expected. Far from presenting a regular variability pattern, XTE J1739-302 shows periods of high, intermediate, and low flaring activity.

Blay, P.↗

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own. While the integration issues span numerous timescales (from microseconds to many months), this article focuses on reliability and stability challenges on short timescales (microseconds to seconds). In other words, we seek to answer (to the extent that it is currently known) how to ensure the frequency and voltage stability in an island power system with very high instantaneous levels of wind and PVs. And because island power systems are often among the first to reach these very high instantaneous levels of wind and PV generation, we note that they are forging a path for larger interconnected power systems to follow.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Impact of Generator Flexibility on Electric System Costs and Integration of Renewable Energy

Flexibility of traditional generators plays an important role in accommodating the increased variability and uncertainty of wind and solar on the electric power system. Increased flexibility can be achieved with changes to operational practices or upgrades to existing generation. One challenge is in understanding the value of increasing flexibility, and how this value may change given higher levels of variable generation. This study uses a commercial production cost model to measure the impact of generator flexibility on the integration of wind and solar generators. We use a system that is based on two balancing areas in the western United States with a range of wind and solar penetrations between 15% and 60%, where instantaneous penetration of wind and solar is limited to 80%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal Size of Energy Storage to Accommodate High Penetration of Renewable Resources in WECC

The variability and intermittence of wind power will cause the large imbalance power that demands more expensive ancillary service. Energy storage, fast response but costly, is a viable solution to suppress the fluctuation of wind power. However, the determination of energy storage is a great challenge given the load demand and wind power uncertainties This paper proposes to use Discrete Fourier Transform (DFT) to decompose the imbalance power into different time-varying components, i.e., intra-week, intra-day, intra-hour and real-time. Therefore, the imbalance power required to be compensated by energy storage can be quantified. By compensating the fast-changing imbalance power (the slowly changing power is provided by the conventional generators), the size of energy storage can be optimized in order to accommodate integration of high penetration of wind power. The simulation results on the 2030 Western Electricity Coordinating Council (WECC) system demonstrate effectiveness and efficiency of this approach.

Makarov, Yuri V.↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.9, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

13 HYDRO ENERGY↗

Renewable Energy Zones for the Africa Clean Energy Corridor

Multi-criteria Analysis for Planning Renewable Energy (MapRE) is a study approach developed by the Lawrence Berkeley National Laboratory with the support of the International Renewable Energy Agency (IRENA). The approach combines geospatial, statistical, energy engineering, and economic methods to comprehensively identify and value high-quality wind, solar PV, and solar CSP resources for grid integration based on techno-economic criteria, generation profiles (for wind), and socio-environmental impacts. The Renewable Energy Zones for the Africa Clean Energy Corridor study sought to identify and comprehensively value high-quality wind, solar photovoltaic (PV), and concentrating solar power (CSP) resources in 21 countries in the East and Southern Africa Power Pools to support the prioritization of areas for development through a multi-criteria planning process. These countries include Angola, Botswana, Burundi, Djibouti, Democratic Republic of Congo, Egypt, Ethiopia, Kenya, Lesotho, Libya, Malawi, Mozambique, Namibia, Rwanda, South Africa, Sudan, Swaziland, Tanzania, Uganda, Zambia, and Zimbabwe. The study includes the methodology and the key results including renewable energy potential for each region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ramping Performance Analysis of the Kahuku Wind-Energy Battery Storage System

High penetrations of wind power on the electrical grid can introduce technical challenges caused by resource variability. Such variability can have undesirable effects on the frequency, voltage, and transient stability of the grid. Energy storage devices can be an effective tool in reducing variability impacts on the power grid in the form of power smoothing and ramp control. Integrating anenergy storage system with a wind power plant can help smooth the variable power produced from wind. This paper explores the fast-response, megawatt-scale, wind-energy battery storage systems that were recently deployed throughout the Hawaiian islands to support wind and solar projects.

17 WIND ENERGY↗

Exploring Novel Configuration Designs Alternatives for Lazy Wave Submarine Power Cables

Floating offshore wind turbines require a complex integrated design to balance the platform response and station-keeping requirements in a highly dynamic environment. Dynamic subsea power cables are one of the critical components that have to be considered in detail to ensure both extreme, as well as repeated operational conditions do not exceed the cable design limits. This paper presents the design feasibility limits of a 66kV dynamic cable for a lazy wave configuration. The work explores an innovative staggered cable configuration that has the potential to provide additional compliance in shallow water conditions. Both configurations are evaluated using the motions of a representative floating wind platform under development for deployment in relatively shallow water depth of 150m. The assessment was conducted using the hydrodynamic software Orcaflex, incorporating a range of design inputs and design variations. Key parameters analysed include cable curvature and effective tension and bending stress. The alternative cable configuration provides a more gradual crossing of the water column, which would allow to support increased platform excursions in shallow water depths. The design uses a combined buoyancy and bend protection element, offering designers additional options for challenging operational conditions. The paper will be of interest to designers and developers of floating wind projects, providing a comparative assessment between the conventional lazy wave configuration and an innovative alternative that enables larger cable and mooring excursion envelopes in challenging conditions.

16 TIDAL AND WAVE POWER↗

Subsonic and transonic hinge moment and wing bending/torsion characteristics of .015 scale space shuttle models 49-0 and 67-TS in the Rockwell International trisonic wind tunnel (IA70), volume 1

Experimental aerodynamic investigations were conducted on an 0.015-scale representation of the integrated space shuttle launch vehicle in the trisonic wind tunnel. The primary test objective was to obtain subsonic and transonic elevon and bodyflap hinge moments and wing bending-torsion moments in the presence of the launch vehicle. Wing pressures were also recorded for the upper and lower right wing surfaces at two spanwise stations. The hinge moment, wing bending/torsion moments and wing pressure data were recorded over an angle-of-attack (alpha) range from -8 deg to +8 deg, and angle-of-sideslip (beta) range from -8 deg to +8 deg and at Mach numbers of 0.90, 1.12, 1.24 and 1.50. Tests were also conducted to determine the effects of the orbiter rear attach cross beam and the forward attach wedge and strut diameter. The orbiter alone was tested at 0.90 and 1.24 Mach number only.

Hughes, M. T.↗

Sodar Data from Oyster Bay at Winyah Bay National Estuarine Research Reserve in South Carolina

The SecondWind Triton® is a SODAR (SOnic Detection and Ranging) sonic wind profiler (Triton® sodar) system capable of profiling the wind characteristics up to 200m above the instrument. SODAR systems transmit acoustic chirps into the atmosphere and measure the backscattered signal returned to the device. The primary source of acoustic scattering is variations in air temperature, which cause changes in the refractive index of sound. By measuring the Doppler-shifted frequency of these returned signals, the Triton® can calculate the wind’s speed and direction for the volume of air above the instrument, measured at ten fixed heights, known as station heights. The Triton® is specifically designed for the purpose of wind energy resource assessment as it can remotely capture wind data at heights above ground where wind turbine rotors operate. The measurements made include horizontal wind speed and direction, vertical wind speed, and turbulence. Other integrated sensors provide time and location via GPS, barometric pressure, humidity, and the tilt of the instrument. The study area is located east of Georgetown, South Carolina in North Inlet - Winyah Bay National Estuarine Research Reserve. The monitoring period for data in this report begins 5/14/2009 9:30:00 AM EST and ends 8/2/2010 11:40:00 AM EST.

17 WIND ENERGY↗

A systems engineering vision for floating offshore wind cost optimization

The U.S. offshore wind resource potential is immense, and often in close proximity to densely-populated coastal load centers. In many U.S. coastal areas, water depths favor the deployment of floating over fixed-bottom offshore wind technology. Floating offshore wind plants have the potential to be cost-competitive with fixed-bottom installations, but because the technology has not yet been deployed at commercial scale, it is not clear when and with what configurations this potential cost parity can be achieved. This article first reviews the state of floating offshore wind technology and deployments to identify key gaps that must be addressed to bring down the overall cost of energy produced. The article then puts forth a long-term vision for a research program and design methodology that may be able to push floating wind plants toward a lower levelized cost of energy than fixed-bottom offshore wind. The method involves a fully integrated systems-engineering and techno-economic design approach to capture the complex interactions between the physics, manufacturing, installation, and operation of floating wind turbines to achieve transformational cost reductions. The approach also envisions multifidelity and uncertainty management strategies to examine the most robust and viable concepts in the design trade-space. To better focus the computational resources, engineering lessons learned from existing offshore wind systems and concept studies are used to develop a set of criteria that can be applied to prefilter candidate technology building blocks that have the greatest cost reduction potential.

17 WIND ENERGY↗

Incorporation of the Rotor-Equivalent Wind Speed into the Weather Research and Forecasting Model’s Wind Farm Parameterization

Wind power installations have been increasing in recent years. Because wind turbines can influence local wind speeds, temperatures, and surface fluxes, weather forecasting models should consider their effects. Wind farm parameterizations do currently exist for numerical weather prediction models. They generally consider two turbine impacts: elevated drag in the region of the wind turbine rotor disk and increased turbulent kinetic energy production. The wind farm parameterization available in the Weather Research and Forecasting (WRF) Model calculates this drag and TKE as a function of hub-height wind speed. However, recent work has suggested that integrating momentum over the entire rotor disk [via a rotor-equivalent wind speed (REWS)] is more appropriate, especially for cases with high wind shear. In this study, we implement the REWS in the WRF wind farm parameterization and evaluate its impacts in an idealized environment, with varying amounts of wind speed shear and wind directional veer. Specifically, we evaluate three separate cases: neutral stability with low wind shear, high stability with high wind shear, and high stability with nonlinear wind shear. For most situations, use of the REWS with the wind farm parameterization has marginal impacts on model forecasts. However, for scenarios with highly nonlinear wind shear, the REWS can significantly affect results.

17 WIND ENERGY↗

Synergistic Integration of Multiple Wave Energy Converters with Adaptive Resonance and Offshore Floating Wind Turbines through Bayesian Optimization

We developed a synergistic ocean renewable system where an array of Wave Energy Converters (WEC) with adaptive resonance was collocated with a Floating Offshore Wind Turbine (FOWT) such that the WECs, capturing wave energy through the resonance adapting to varying irregular waves, consequently reduced FOWFT loads and turbine motions. Combining Surface-Riding WECs (SR-WEC) individually designed to feasibly relocate their natural frequency at the peak of the wave excitation spectrum for each sea state, and to obtain the highest capture width ratio at one of the frequent sea states for annual average power in a tens of kilowatts scale with a 15 MW FOWT based on a semi-submersible, Bayesian Optimization is implemented to determine the arrangement of WECs that minimize the annual representation of FOWT’s wave excitation spectra. The time-domain simulation of the system in the optimized arrangement is performed, including two sets of interactions: one set is the wind turbine dynamics, mooring lines, and floating body dynamics for FOWT, and the other set is the nonlinear power-take-off dynamics, linear mooring, and individual WECs’ floating body dynamics. Those two sets of interactions are further coupled through the hydrodynamics of diffraction and radiation. For sea states comprising Annual Energy Production, we investigate the capture width ratio of WECs, wave excitation on FOWT, and nacelle acceleration of the turbine compared to their single unit operations. We find that the optimally arranged SR-WECs reduce the wave excitation spectral area of FOWT by up to 60% and lower the turbine’s peak nacelle acceleration by nearly 44% in highly occurring sea states, while multiple WECs often produce more than the single operation, achieving adaptive resonance with a larger wave excitation spectra for those sea states. The synergistic system improves the total Annual Energy Production (AEP) by 1440 MWh, and we address which costs of Levelized Cost Of Energy (LCOE) can be reduced by the collocation.

Engineering↗

A split explicit reformulation of the regional numerical weather prediction model of the Japan Meteorological Agency

The split explicit integration scheme for numerical weather prediction models is employed in a version of the regional numerical weather prediction model of the Japan Meteorological Agency. The finite-difference scheme of the model is designed in the manner proposed by Okamura (1975). The horizontal advection terms in the governing equations are integrated with a time step limited by the wind speed while the terms which describe inertial-gravity oscillations are integrated in a succession of shorter time steps. The physical processes included within the model are precipitation, small-scale convection, surface exchanges of sensible and latent heat, and radiative heating and cooling. An example of a surface pressure forecast over Europe is shown for initial data observed at 0000 GMT 29 December 1979. Quantitative precipitation forecasts over Europe and North America for the 24 h period beginning at 0000 GMT 30 December 1979 are also shown. It is concluded that the model is capable of realistically depicting the evolution of synoptic-scale systems.

Duffy, D. G.↗

Analysis methods for wind turbine control and electrical system dynamics

The integration of new energy technologies into electric power systems requires methods which recognize the full range of dynamic events in both the new generating unit and the power system. Since new energy technologies are initially perceived as small contributors to large systems, little attention is generally paid to system integration, i.e. dynamic events in the power system are ignored. As a result, most new energy sources are only capable of base-load operation, i.e. they have no load following or cycling capability. Wind turbines are no exception. Greater awareness of this implicit (and often unnecessary) limitation is needed. Analysis methods are recommended which include very low penetration (infinite bus) as well as very high penetration (stand-alone) scenarios.

Hinrichsen, E. N.↗

Comparative Assessment of Direct Drive High Temperature Superconducting Generators in Multi-Megawatt Class Wind Turbines

This paper summarizes the work completed under the CRADA between NREL and American Superconductor (AMSC). The CRADA combined NREL and AMSC resources to benchmark high temperature superconducting direct drive (HTSDD) generator technology by integrating the technologies into a conceptual wind turbine design, and comparing the design to geared drive and permanent magnet direct drive (PMDD) windturbine configurations. Analysis was accomplished by upgrading the NREL Wind Turbine Design Cost and Scaling Model to represent geared and PMDD turbines at machine ratings up to 10 MW and then comparing cost and mass figures of AMSC's HTSDD wind turbine designs to theoretical geared and PMDD turbine designs at 3.1, 6, and 10 MW sizes. Based on the cost and performance data supplied by AMSC,HTSDD technology has good potential to compete successfully as an alternative technology to PMDD and geared technology turbines in the multi megawatt classes. In addition, data suggests the economics of HTSDD turbines improve with increasing size, although several uncertainties remain for all machines in the 6 to 10 MW class.

17 WIND ENERGY↗