Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Science and Technology of Future Light Sources: A White Paper

Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects (Figure 1.1). The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of electromagnetic origin, it is intuitively clear that electromagnetic radiation is the critical tool in the study of material properties. On the level of atoms, electrons, and spins, x-rays have proved especially valuable. Future advanced x-ray sources and instrumentation will extend the power of x-ray methods to reach greater spatial resolution, increased sensitivity, and unexplored temporal domains. The purpose of this document is threefold: (1) summarize scientific opportunities that are beyond the reach of today's x-ray sources and instrumentation; (2) summarize the requirements for advanced x-ray sources and instrumentation needed to realize these scientific opportunities, as well as potential methods of achieving them; and (3) outline the R&D required to establish the technical feasibility of these advanced x-ray sources and instrumentation.

43 PARTICLE ACCELERATORS↗

The Latent Dirichlet Allocation model applied to airborne LiDAR data: A case study on mapping forest degradation associated with fragmentation and fire in the Amazon region

1. LiDAR data are being increasingly used to provide a detailed characterization of the vertical profile of forests. This characterization enables the generation of new insights on the influence of environmental drivers and anthropogenic disturbances on forest structure as well as on how forest structure influences important ecosystem functions and services. Unfortunately, extracting information from LiDAR data in a way that enables the spatial visualization of forest structure, as well as its temporal changes, is challenging due to the high dimensionality of these data. 2. In this study, we show how the Latent Dirichlet Allocation model applied to LiDAR data (LidarLDA) can be used to identify forest structural types and how the relative abundance of these forest types changes throughout the landscape. The code to fit this model is made available through the open-source r package LidarLDA in github. We illustrate the use of LidarLDA both with simulated data and data from a large-scale fire experiment in the Brazilian Amazon region. 3. Using simulated data, we demonstrate that LidarLDA accurately identifies the number of forest types as well as their spatial distribution and absorptance probabilities. For the empirical data, we found that LidarLDA detects both landscape-level patterns in forest structure as well as the strong interacting effect of fire and forest fragmentation on forest structure based on the experimental fire plots. More specifically, LidarLDA reveals that proximity to forest edge exacerbates the impact of fires, and that burned forests remain structurally different from unburned areas for at least 7 years, even when burned only once. Importantly, LidarLDA generates insights on the 3D structure of forest that cannot be obtained using more standard approaches that just focus on top-of-the-canopy information (e.g. canopy height models based on LiDAR data). 4. By enabling the mapping of forest structure and its temporal changes, we believe that LidarLDA will be of broad utility to the ecological research community.

54 ENVIRONMENTAL SCIENCES↗

Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment quality. The performance of our automated method was evaluated by comparing the automatically identified best-quality segments identified by the computer to those selected by the observers. Results: For the 20 test cases, 254 groups of corresponding vessel segments were identified after multiple phase registration and recursive matching. The AI-BQ segments agreed with the radiologist’s top 2 ranked segments in 78.3% of the 254 groups (Cohen’s kappa 0.60), and with the 4 nonradiologist observers in 76.8%, 84.3%, 83.9%, and 85.8% of the 254 groups. In addition, 89.4% of the AI-BQ segments agreed with at least two observers’ top 2 rankings, and 96.5% agreed with at least one observer’s top 2 rankings. In comparison, agreement between the four observers’ top ranked segment and the radiologist’s top 2 ranked segments were 79.9%, 80.7%, 82.3%, and 76.8%, respectively, with kappa values ranging from 0.56 to 0.68. Conclusions: The performance of our automated method for selecting the best-quality coronary segments from a multiple-phase cCTA acquisition was comparable to the selection made by human observers. This study demonstrates the potential usefulness of the automated method in clinical practice, enabling interpreting physicians to fully utilize the best available information in cCTA for diagnosis of coronary disease, without requiring manual search through the multiple phases and minimizing the variability in image phase selection for evaluation of coronary artery segments across the diversity of human readers with variations in expertise.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-21: Deformation Mapping and Shape Prediction with 3D Tumor Volume Morphing

Purpose: To compare projection-based versus global correction that compensate for deadtime count loss in SPECT/CT images. Methods: SPECT/CT images of an IEC phantom (2.3GBq 99mTc) with ∼10% deadtime loss containing the 37mm (uptake 3), 28 and 22mm (uptake 6) spheres were acquired using a 2 detector SPECT/CT system with 64 projections/detector and 15 s/projection. The deadtime, Ti and the true count rate, Ni at each projection, i was calculated using the monitor-source method. Deadtime corrected SPECT were reconstructed twice: (1) with projections that were individually-corrected for deadtime-losses; and (2) with original projections with losses and then correcting the reconstructed SPECT images using a scaling factor equal to the inverse of the average fractional loss for 5 projections/detector. For both cases, the SPECT images were reconstructed using OSEM with attenuation and scatter corrections. The two SPECT datasets were assessed by comparing line profiles in xyplane and z-axis, evaluating the count recoveries, and comparing ROI statistics. Higher deadtime losses (up to 50%) were also simulated to the individually corrected projections by multiplying each projection i by exp(-a*Ni*Ti), where a is a scalar. Additionally, deadtime corrections in phantoms with different geometries and deadtime losses were also explored. The same two correction methods were carried for all these data sets. Results: Averaging the deadtime losses in 5 projections/detector suffices to recover >99% of the loss counts in most clinical cases. The line profiles (xyplane and z-axis) and the statistics in the ROIs drawn in the SPECT images corrected using both methods showed agreement within the statistical noise. The count-loss recoveries in the two methods also agree within >99%. Conclusion: The projection-based and the global correction yield visually indistinguishable SPECT images. The global correction based on sparse sampling of projections losses allows for accurate SPECT deadtime loss correction while keeping the study duration reasonable.

60 APPLIED LIFE SCIENCES↗

Automated compatibility checking of prefabricated components using 3D as-built models and BIM

There have been recent efforts to use reality capture technologies to perform remote quality control in construction. However, there is a lack of research efforts in detecting construction incompatibilities in modular construction using reality capture technologies. The construction incompatibilities in modular construction often cause reworks and delays in the project schedule. To address this issue, this paper presents a general compatibility analysis method that propose scanning the modules in manufacturing plant and construction site, and check module-to-module compatibility remotely, prior to the shipment and installation. This study provides three sample module-to-module compatibility scenarios to validate the proposed compatibility analysis. The case study results show that the compatibility analysis method was able to identify the compatibility issues with high accuracy. Lastly, the compatibility analysis method was validated in terms of accuracy and time performance in six scenarios that was defined on the modules.

42 ENGINEERING↗

Interior soft x-ray tomography with sparse global sampling

To investigate the feasibility of interior imaging reconstruction in soft X-ray tomography for higher-resolution cellular imaging, including whole-cell imaging, we develop an alignment and reconstruction algorithm that combines a small number of sparse whole-cell images with a high-resolution local interior scan. Based on numerical simulations, we demonstrate that combined reconstructions mitigate the depth-of-field limitation in high-resolution scans, enable radiation dose optimization, and yield quantitative X-ray absorption values with sparse sampling. We further validate our numerical approach using experimental data from two different cell types and show that the combined reconstruction reliably provides high spatial resolution within an interior region of interest of a whole cell. The resulting sparse reconstruction framework offers robust, faithful visualization of cellular organelles in soft X-ray tomography. This mesoscale imaging strategy allows one to ‘scout’ and zoom into selected subcellular volumes of interest, enabling increased spatial resolution without sacrificing larger-volume imaging and providing information on the relative positions of all organelles within a cell.

3D imaging↗

A new method for analyzing and visualizing plasma simulations using a phase-space tessellation

We apply a novel phase-space interpolation technique referred to as the simplex-in-cell (SIC) method to analyze two- and three-dimensional particle-in-cell (PIC) simulations of electromagnetic plasmas. SIC relies on a discretization of the initial phase-space distribution function into simplices, which allows an approximation to the full, continuously defined distribution function to be constructed at any later time in the simulation. This allows densities, currents, and even full momentum distribution functions to be measured at any point in the simulation domain without averaging over control volumes. The SIC approach applies to any PIC simulation for which a tessellation of the initial particle distribution can be constructed. In this study, we use outputs from standard PIC simulations of the Weibel instability and compare physical quantities such as charge and current densities calculated in postprocessing using SIC and standard particle deposits. Using 2D simulations with 1–65 536 particles-per-cell, we find that SIC eliminates discrete particle noise and in some cases can reach a given noise level using ~1000 times fewer simulation particles than with standard particle deposition schemes. In regions of low density, such as between current filaments, SIC is able to capture small amplitude features even with fewer particles than gridpoints due to the deformable nature of the SIC volume elements. Here, by calculating momentum distributions, we show how SIC can capture low density tails in the spectrum using far fewer particles than are necessary for standard particle deposits. We calculate the charge density on spatial grids of increasing resolution to demonstrate the ability of SIC to reveal fine-scale details that are not accessible with standard particle deposits. Finally, we show how SIC can be extended to 3D and give an example of its use to calculate the charge density from 3D PIC simulations of the Weibel instability. These results motivate the future implementation of SIC directly in the simulation force calculation for a novel low-noise electromagnetic plasma simulation method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiological data consolidation and 3D modeling of a building - 15473

A portion of a building at an industrial facility that conducted monazite sands-processing operations in the 1950's under contract to the Atomic Energy Commission (AEC) became contaminated. Subsequently the U.S. Department of Energy designated the facility for remedial action under the Formerly Used Sites Remedial Action Program (FUSRAP). Remedial investigation, remedial actions and post-remediation surveys have been conducted in portions of the building. Radiological data for the interior of the building were compiled, evaluated and presented in a three dimensional (3-D) model (the model) created by AMEC Foster Wheeler in order to identify areas that meet the Record of Decision (ROD) cleanup criteria, and identity areas that may require remedial action or may require additional investigation due to data gaps. The data from different phases of investigation and remediation cover different portions of the building and in some cases overlap. In addition, the data were collected over a period of more than ten years, for different objectives, and thus the instruments and methods for establishing efficiency were not necessarily consistent. The data consolidation process included determining the relative quality of data points to include in the model and the development of rationale associated with assigning a quality level (i.e. ranking) to each data point. The rationale for ranking data quality included, as the primary determining factors, chronological order of the data (most recent was ranked as more reliable), certainty of the sample locations within the building, and analytical data quality. A 3-D model of the building was created using a laser point cloud scan which was then converted into a 3-D design model. Sample locations were then entered into the model and linked with the analytical database to allow display of the radiological results in the model. The visual model allows both strategic and tactical decisions to be made, depending on the level of detail examined. The evaluation process allowed maximum use of the historical data set, rather than requiring older data to be disregarded, and provided at a minimum a qualitative sense of data quality/confidence in the data. The (authors)process also highlights the importance of collecting high quality data from the very beginning with a consistent locational coordinate system, and the need for a good visualization model in order to assess contaminant locations during remedial action or post-remediation surveys.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model, data, and code for paper "Modeling of streamflow in a 30-kilometer-long reach spanning 5 years using OpenFOAM 5.x"

The data package includes data, model, and code that support the analyses and conclusions in the paper titled “modeling of streamflow in a 30-kilometer-long reach spanning 5 years using OpenFOAM 5.x”. The primary goal of this paper is to demonstrate that key streamflow properties such as water depth, flow velocity, and dynamic pressure in a natural river at 30-kilometer scale over 5 years can be reliably and efficiently modeled using the computational framework presented in this paper. To support the paper, various data types from remote sensing, field observations, and computational models are used. Specific details are described as follows. Firstly, the river bathymetry data was obtained from a Light Detection and Ranging (LiDAR) survey. This data is then converted to a triangulated surface format, STL, for mesh generation in OpenFOAM. The STL data can be found in Model_Setups/BaseCase_2013To2015/constant/triSurface. The OpenFOAM mesh generated using this STL file can be found in constant/polyMesh. Other model setups, boundary and initial conditions can be found in /system and /0.org under folder BaseCase_2013To2015. A similar data structure can also be found in BaseCase_2018To2019 for the simulations during 2018 and 2019. Secondly, the OpenFOAM simulations need the upstream discharge and water depth information at the upstream boundary to drive the model. These data are generated from a one-dimensional hydraulic model and the data can be found under the folder Model_Setups /1D model Mass1 data. The mass1_65.csv and mass1_191.csv files include the results of the 1D model at the model inlet and outlet, respectively. The Matlab source code Mass1ToOFBC20182019.m is used to convert these data into OpenFOAM boundary condition setups.With the above OpenFOAM model, it can generate data for water surface elevation, flow velocity, and dynamic pressure. In this paper, the water surface elevation was measured at 7 locations during different periods between 2011 and 2019. The exact survey locations (see Fig1_SurveyLocations.txt) can be found in folder Fig_1. The variation of water stage over time at the 7 locations can be found in folder /Observation_WSE. The data type include .txt, .csv, .xlsx, and .mat. The .mat data can be loaded by Matlab.We also measured the flow velocities at 12 cross-sections along the river. At each cross-section, we recorded the x, y locations, depth, three velocity components u,v,w. These data are saved to a Matlab format which can be found under folder /Observation_Velocity and /Fig_1. The relative locations of velocity survey locations to the river bathymetry can be found in Figure 1c.The water stage data at the 7 locations from OpenFOAM, 1D, and 2D hydraulic models are also provided to evaluate the long-term performance of 3D models vs 1D/2D models. The water stage data for the 7 locations from OpenFOAM have been saved to .mat format and can be found in /OpenFOAM_WSE. The water stage data from the 1D model are saved in .csv format and can be found in /Mass1_WSE. The water stage from the 2D model is saved as .mat format and can be found in / Mass2_WSEIn addition, the OpenFOAM model outputs the information of hydrostatic and hydrodynamic pressure. They are saved as .mat format under folder /Fig_11/2013_1. As the files are too large, we only uploaded the data for January 2013. The area of different ratio of dynamic pressure to static pressure for all simulation range, i.e., 2013-2015, are saved to .mat format. They can be found in /Fig_11/PA. Further, the data of wall clock time versus the solution time of the OpenFOAM modeling are also saved to .mat format under folder /Fig_13/LogsMat. In summary, the data package contains seven data types, including .txt, .csv, .xlsx, .dat, .stl, .m, and .mat. The former 4 types can be directly open using a text editor or Microsoft Office. The .mat format needs to be read by Matlab. The Matlab source code .m files need to be run with Matlab. The OpenFOAM setups can be visualized in ParaView. The .stl file can be opened in ParaView or Blender. The data in subfolders Fig_1 to Fig_10 and Fig_12 are copied from the aforementioned data folders to generate specific figures for the paper. A readME.txt file is included in each subfolder to further describe how the data in each folder are generated and used to support the paper.Please use the data package's DOI to cite the data package. Please contact yunxiang.chen@pnnl.gov if you need more data related to the paper.

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-61: Electrodynamics and Nano-Scale Fluid Dynamics in Protein Localization of Nuclear Pore Complexes

Purpose: To develop a simulation to catalyze a reevaluation of common assumptions about 3 dimensional diffusive processes and help cell biologists gain a more nuanced, intuitive understanding of the true physical hurdles of protein signaling cascades. Furthermore, to discuss the possibility of intracellular electrodynamics as a critical, unrecognized component of cellular biology and protein dynamics that is necessary for optimal information flow from the cell membrane to the nucleus. Methods: The Unity 3D gaming physics engine was used to build an accurate virtual scale model of the cytoplasm within a few hundred nanometers of the nuclear membrane. A cloud of simulated pERK proteins is controlled by the physics simulation, where diffusion is based on experimentally measured values and the electrodynamics are based on theoretical nano-fluid dynamics. The trajectories of pERK within the cytoplasm and through the 1250 nuclear pores on the nuclear surface is recorded and analyzed. Results: The simulation quickly demonstrates that pERKs moving solely by diffusion will rarely locate and come within capture distance of a nuclear pore. The addition of intracellular electrodynamics between charges on the nuclear pore complexes and on pERKs increases the number of successful translocations by allowing the electro-physical attractive effects to draw in pERKs from the cytoplasm. The effects of changes in intracellular shielding ion concentrations allowed for estimation of the “capture radius” under varying conditions. Conclusion: The simulation allows a shift in perspective that is paramount in attempting to communicate the scale and dynamics of intracellular protein cascade mechanics. This work has allowed researchers to more fully understand the parameters involved in intracellular electrodynamics, such as shielding anion concentration and protein charge. As these effects are still far below the spatial resolution of currently available measurement technology this simulation is invaluable to researchers to visualize and study current hypotheses concerning protein dynamics.

60 APPLIED LIFE SCIENCES↗

Dynamic in situ imaging of methane hydrate formation in coal media

Fast 3D X-ray imaging has proved to provide crucial insights into multi-phase dynamic processes in various geomaterials. In particular, many in situ imaging experiments have been made to study gas-hydrate formation in porous sandy samples. Such imaging is challenging for the methane gas-hydrate formation in coal samples because of the coal micro-porosity structure and lower X-ray contrast. Here we present results of the first dynamic in situ micro-computed tomography experiment of methane-hydrate formation in coal samples. Synchrotron phase-contrast tomography techniques allowed to achieve necessary contrast levels to separate all the materials of interest (gas, water, coal, and gas hydrate) in reconstructed images with high spatial and temporal resolution. The imaging results are compared to the ones from a similar tomographic experiment with sand samples. Methane-hydrate formation is accompanied by the water movements caused by cryogenic water suction that happens in sequences of short fast movements with longer equilibrium states in between. Only one type of the hydrate formation was observed in coal (growth as shells on grain boundaries) as opposed to three types in sand (shells, growth into gas pockets, and inside water volumes). In particular, this leads to a slower hydrateformation speed in coal. For the coal sample, we also observed water extraction from grains, and interpreted it as competitive sorption of methane. Lastly, we visualized the dynamic behavior of this water extraction via microchannels inside the coal grains, and performed nano-tomography imaging of these channels for a better understanding of this phenomenon.

58 GEOSCIENCES↗

A Visual Understanding of Circular Dichroism Spectroscopy

Mapping chemical and structural properties to electronic and magnetic responses is critical to many applications such as quantum information science, where the precise storage and transmission of unique information is paramount. Specifically, constructing molecules and materials that provide strong polarized responses at tunable frequencies and with large anisotropies is key to optical processing of quantum information. Chiral molecules provide chiroptical response to circularly polarized light, making them attractive for quantum information science and other applications related to sensing, polarized photodetectors, and spintronics. Predicting a molecular design, a priori, with large anisotropies to circularly polarized light is challenging due to the complex interplay between electric and magnetic components of the optical response. In this work, we explore a visual representation of the electronic chiroptical response by decomposing the rotary strength into its constituent components. Here, we make use of the intuitive electronic oscillator framework to develop classical intuition regarding the rotary strength and its constituents. We explore three model chemical systems that exhibit local and global chirality. Our analysis reveals that local chirality necessarily exhibits competition between the local chiral center and chirality induced in other fragments of the molecule, resulting in both unexpected nonmonotonic trends and sign flips in chemically adjacent geometries. Furthermore, we can visually distinguish between local and global chirality via examination of the transition chiral tensor. Interestingly, we make strong connections to ferromagnetic and antiferromagnetic spin systems in that chiroptically inactive transitions exhibit antiferromagnetic-like alternating orbital patterns while active transitions show domain formation in an ferromagnetic-like alignment that produces a net chiroptical response.

36 MATERIALS SCIENCE↗

In-plane visibility of lesions using breast tomosynthesis and digital mammography

Purpose: The purpose of this work was to evaluate the visibility of simulated lesions in 2D digital mammography (DM) and breast tomosynthesis (BT) images of patients. Methods: Images of the same women were acquired on both a DM system (Mammomat Novation, Siemens Healthcare, Erlangen, Germany) and a BT prototype system adapted from the same type of DM system. Using the geometrical properties of the two systems, simulated lesions were projected and added to each DM image as well as to each BT projection image prior to 3D reconstruction. The same beam quality and approximately the same total absorbed dose to the glandular tissue were used for each breast image acquisition on the two systems. A series of four-alternative forced choice human observer experiments was conducted for each of five simulated lesion diameters: 0.2, 1, 3, 8, and 25 mm. An additional experiment was conducted for the 0.2 mm lesion in BT only at twice the dose level (BT{sub 2x}). Threshold signal was defined as the lesion signal intensity required for a detectability index (d{sup '}) of 2.5. Four medical physicists participated in all experiments. One experiment, consisting of 60 cases, was conducted per test condition (i.e., lesion size and signal combination). Results: For the smallest lesions (0.2 mm), the threshold signal for DM was 21% lower than for BT at equivalent dose levels, and BT{sub 2x} was 26% lower than DM. For the lesions larger than 1 mm, the threshold signal increased linearly (in log space) with the lesion diameter for both DM and BT, with DM requiring around twice the signal as BT. The difference in the threshold signal between BT and DM at each lesion size was statistically significant, except for the 0.2 mm lesion between BT{sub 2x} and DM. Conclusions: The results of this study indicate that low-signal lesions larger than 1.0 mm may be more visible in BT compared to DM, whereas 0.2 mm lesions may be better visualized with DM compared to BT, when compared at equal dose.

60 APPLIED LIFE SCIENCES↗

Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy

Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.

60 APPLIED LIFE SCIENCES↗

Laboratory micro- and nanoscale X-ray tomographic investigation of Al–7 at.%Cu solidification structures

X-ray computed tomography across multiple length scales provides an opportunity to non-destructively visualize and quantify the micro- to nano-scale microstructural features of solidification structures in three dimensions. Aluminum–7 at.%copper samples were directionally solidified at three cooling rates (0.44, 0.67, and 1.33 °C/s), resulting in systematic changes in the as-solidified microstructure, which are difficult to quantify using traditional microscopic techniques. The cooling rate of a material affects its ultimate microstructure, and characterizing that microstructure is key to predicting and understanding its bulk properties. Here, two different laboratory X-ray computed tomography instruments were used to characterize as-solidified microstructures, including micro-scale computed tomography with approximately 1 mm field-of-view, ∼ 1.7 μm resolution, and nano-scale X-ray computed tomography ∼ 65 μm FOV, 150 nm resolution. Micro-scale X-ray radiography and computed tomography enabled a quantitative investigation of changes in the primary dendritic solidification structure with increasing cooling rate. Nano-scale absorption contrast X-ray computed tomography resolved the distinct phases of the lamellar eutectic structure and three dimensional measurements of the ∼ 1 μm interlamellar spacing. It is found that the lamella eutectic structure thickness is inversely proportional to the cooling rate. Nano-scale Zernike phase contrast was also used to image voids at eutectic colony boundaries. The application and resolution of these two instruments are discussed with respect to the resolvable features of the solidification structures. - Highlights: • Al–Cu eutectic is a model system for studying solidification microstructure. • X-ray computed tomography provides a 3D picture of these complex structures. • Micro-scale tomography images the primary and secondary dendritic structures. • Nano-scale tomography images the eutectic lamella and measures its thickness. • The ∼ 1 micrometer thickness of the eutectic lamella correlates to the cooling rate.

36 MATERIALS SCIENCE↗

Coronary artery wall imaging in mice using osmium tetroxide and micro-computed tomography (micro-CT)

The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO{sub 4}) solution. As a tissue-staining contrast agent, OsO{sub 4} is retained in the vessel wall and surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO{sub 4} preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE{sup -/-}) mice at 10 {mu}m resolution. The results show that walls of coronary arteries as small as 45 {mu}m in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO{sub 4} and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts.

59 BASIC BIOLOGICAL SCIENCES↗

Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications

The authors are developing a computerized pulmonary vessel segmentation method for a computer-aided pulmonary embolism (PE) detection system on computed tomographic pulmonary angiography (CTPA) images. Because PE only occurs inside pulmonary arteries, an automatic and accurate segmentation of the pulmonary vessels in 3D CTPA images is an essential step for the PE CAD system. To segment the pulmonary vessels within the lung, the lung regions are first extracted using expectation-maximization (EM) analysis and morphological operations. The authors developed a 3D multiscale filtering technique to enhance the pulmonary vascular structures based on the analysis of eigenvalues of the Hessian matrix at multiple scales. A new response function of the filter was designed to enhance all vascular structures including the vessel bifurcations and suppress nonvessel structures such as the lymphoid tissues surrounding the vessels. An EM estimation is then used to segment the vascular structures by extracting the high response voxels at each scale. The vessel tree is finally reconstructed by integrating the segmented vessels at all scales based on a 'connected component' analysis. Two CTPA cases containing PEs were used to evaluate the performance of the system. One of these two cases also contained pleural effusion disease. Two experienced thoracic radiologists provided the gold standard of pulmonary vessels including both arteries and veins by manually tracking the arterial tree and marking the center of the vessels using a computer graphical user interface. The accuracy of vessel tree segmentation was evaluated by the percentage of the 'gold standard' vessel center points overlapping with the segmented vessels. The results show that 96.2% (2398/2494) and 96.3% (1910/1984) of the manually marked center points in the arteries overlapped with segmented vessels for the case without and with other lung diseases. For the manually marked center points in all vessels including arteries and veins, the segmentation accuracy are 97.0% (4546/4689) and 93.8% (4439/4732) for the cases without and with other lung diseases, respectively. Because of the lack of ground truth for the vessels, in addition to quantitative evaluation of the vessel segmentation performance, visual inspection was conducted to evaluate the segmentation. The results demonstrate that vessel segmentation using our method can extract the pulmonary vessels accurately and is not degraded by PE occlusion to the vessels in these test cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visualizing Interfacial Jamming Using an Aggregation-Induced-Emission Molecular Reporter

With the interfacial jamming of nanoparticles (NPs), a load-bearing network of NPs forms as the areal density of NPs increases, converting the assembly from a liquid-like into a solid-like assembly. Unlike vitrification, the lineal packing of the NPs in the network is denser, while the remaining NPs can remain in a liquid-like state. It is a challenge to determine the point at which the assemblies jam, since both jamming and vitrification lead to a solid-like behavior of the assemblies. Herein, we show a real-time fluorescence imaging method to probe the evolution of the interfacial dynamics of NP surfactants at the water/oil interface using aggregation-induced emission (AIE) as a reporter for the transition of the assemblies into the jammed state. The AIEgens show typical fluorescence behavior at densities at which they can move and rotate. However, when aggregation of these fluorophores occurs, the smaller intermolecular separation distance arrests rotation, and a significant enhancement in the fluorescence intensity occurs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗