Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

An efficient low- and moderate-resolution spectrograph for the Hale telescope

A new low-to-moderate resolution spectrograph has been designed and built for the Cassegrain focus of the Hale 5.08-meter telescope. To maximize efficiency, resolution, and wavelength coverage the light is divided into two spectra regions by a dichroic filter behind the entrance slit, after which there are two completely separate spectrographs. The blue spectrograph operates from 3200 A to 5200 A while the red one goes from 5200 A to 10,000 A. The red detector is an 800 x 800 TI CCD while the blue detector is a 320 x 512 RCA CCD or a Shectrograph image pulse-counting system. A Boksenberg IPCS can also be mounted on the blue camera. The overall efficiency of the Cassegrain telescope, spectrographs, and CCD's combined, ranges from 5 percent to 13 percent between 3600 A and 8200 A. The spectrograph is usable from 3200 A to 10,400 A.

Oke, J. B.↗

Video Mosaicking for Inspection of Gas Pipelines

A vision system that includes a specially designed video camera and an image-data-processing computer is under development as a prototype of robotic systems for visual inspection of the interior surfaces of pipes and especially of gas pipelines. The system is capable of providing both forward views and mosaicked radial views that can be displayed in real time or after inspection. To avoid the complexities associated with moving parts and to provide simultaneous forward and radial views, the video camera is equipped with a wide-angle (>165 ) fish-eye lens aimed along the axis of a pipe to be inspected. Nine white-light-emitting diodes (LEDs) placed just outside the field of view of the lens (see Figure 1) provide ample diffuse illumination for a high-contrast image of the interior pipe wall. The video camera contains a 2/3-in. (1.7-cm) charge-coupled-device (CCD) photodetector array and functions according to the National Television Standards Committee (NTSC) standard. The video output of the camera is sent to an off-the-shelf video capture board (frame grabber) by use of a peripheral component interconnect (PCI) interface in the computer, which is of the 400-MHz, Pentium II (or equivalent) class. Prior video-mosaicking techniques are applicable to narrow-field-of-view (low-distortion) images of evenly illuminated, relatively flat surfaces viewed along approximately perpendicular lines by cameras that do not rotate and that move approximately parallel to the viewed surfaces. One such technique for real-time creation of mosaic images of the ocean floor involves the use of visual correspondences based on area correlation, during both the acquisition of separate images of adjacent areas and the consolidation (equivalently, integration) of the separate images into a mosaic image, in order to insure that there are no gaps in the mosaic image. The data-processing technique used for mosaicking in the present system also involves area correlation, but with several notable differences: Because the wide-angle lens introduces considerable distortion, the image data must be processed to effectively unwarp the images (see Figure 2). The computer executes special software that includes an unwarping algorithm that takes explicit account of the cylindrical pipe geometry. To reduce the processing time needed for unwarping, parameters of the geometric mapping between the circular view of a fisheye lens and pipe wall are determined in advance from calibration images and compiled into an electronic lookup table. The software incorporates the assumption that the optical axis of the camera is parallel (rather than perpendicular) to the direction of motion of the camera. The software also compensates for the decrease in illumination with distance from the ring of LEDs.

Magruder, Darby↗

The RIKEN Materials Science Beamline at SPring-8: Towards Visualization of Electrostatic Interaction

In order to visualize molecular interaction by the experimental electrostatic potential analysis we have optimized the optical parameters and developed the high-resolution Debye-Scherrer camera at the RIKEN materials science beamline, BL44B2 of SPring-8. For the purpose the camera was designed to be equipped with the hybrid X-ray detector system. One is the conventional detector, the imaging plate readout off-line to carry out high d(interplanar spacing)-resolution measurements and the other is the CCD detector, which can be operated in a camera at variable distances for high angle-resolution measurements. In addition we have been developing an in-situ properties measurement system to visualize the electrostatic interaction completely synchronized with material functions.

43 PARTICLE ACCELERATORS↗

Charge-coupled device camera for the Galileo Jupiter Orbiter spacecraft

A slow-scan television camera called the solid-state imaging subsystem (SSI), built for the Galileo Jupiter Orbiter, is described. The SSI consists of a 1500-mm focal-length telescope coupled to a camera head housing a 800 x 800-element charge-coupled device (CCD) detector based on 'virtual-phase' charge transfer technology. The CCD detector provides broadband sensitivity over 100 times that of a comparable vidicon-tube camera, while also yielding improved resolution, linearity, geometric fidelity, and spectral range. The system noise floor is 30 electrons, which results in a dynamic range of about 3500. Saturation of the detector with 9000-A light, followed by a high-speed erasure cycle prior to exposing each image, stabilizes the detector quantum efficiency at its maximum level for wavelengths beyond 7000 A. An optical schematic diagram of the SSI is included.

Klaasen, K. P.↗

A 5- μ m pitch charge-coupled device optimized for resonant inelastic soft X-ray scattering

Here, we have developed a charge-coupled device (CCD) with 5 μm × 45 μm pixels on high-resistivity silicon. The fully depleted 200 μm-thick silicon detector is back-illuminated through a 10 nm-thick in situ doped polysilicon window and is thus highly efficient for soft through > 8 keV hard X-rays. The device described here is a 1.5 megapixel CCD with 2496 × 620 pixels. The pixel and camera geometry was optimized for Resonant Inelastic X-ray Scattering (RIXS) and is particularly advantageous for spectrometers with limited arm lengths. In this article, we describe the device architecture, construction and operation, and its performance during tests at the Advance Light Source (ALS) 8.0.1 RIXS beamline. The improved spectroscopic performance, when compared with a current standard commercial camera, is demonstrated with a ~280 eV (C K ) X-ray beam on a graphite sample. Readout noise is typically 3-6 electrons and the point spread function for soft C K X-rays in the 5 μm direction is 4.0 μm ± 0.2 μm. Finally, the measured quantum efficiency of the CCD is greater than 75% in the range from 200 eV to 1 keV.

36 MATERIALS SCIENCE↗

Faint comet searching

Comets are usually discovered to a magnitude limit of about 19 at best. This can be improved by one magnitude with a blink-search technique that is described here. To find a new comet, the required search area near opposition is about 600 square degrees at a magnitude limit of about 20.0. Three faint comets were found this way; they are inconspicuous and would not have been discovered in any other manner. It therefore appears that the presently known statistics must be incomplete at the faint end due to incompleteness of the discovery observations. Another future method to find such inconspicuous comets is with electronically scanning cameras and computerized reduction. If such a CCD scannerscope were to have an aperture of about 1.8 m, it could discover at least 40 comets per year.

Gehrels, T.↗

Advanced X-ray Astrophysics Facility (AXAF) science instrumentation

AXAF is to be equipped with a high performance X-ray telescope for the conduction of detailed astrophysics research. The observatory is to be serviced by the Space Station or the Shuttle, depending on capabilities during the AXAF operational period. The AXAF is to utilize the wavelength band from 1.2 A to 120 A. Attention is given to the AXAF science team, the AXAF observatory characteristics, the AXAF science instrument definition program, the Advanced Charge Coupled Device (CCD) Imaging Spectrometer (ACIS), the High Resolution Camera (HRC), the Bragg Crystal Spectrometer (BCS), the X-ray Spectrometer (XRS), the transmission gratings, and the program schedule.

Dailey, C. C.↗

Modeling of internal contaminant deposition on a cold instrument sensor

A model is developed to predict the deposition of contaminants on the CCD sensors of the Wide Field Planetary Camera to determine expected performance parameters. Contaminant deposition due to internal instrument sources is considered as is the mechanism of transport to the CCDs themselves. The Contamination Analysis Program (CAP) model considers deposition and reemission kinetics, nodal containment sources, and internodal shape factors related to line-of-sight transport. Indirect transport is also accounted for in the CAP model by considering the effect of diffuse reflection at internodal exchanges. The effective total transport factors for each node-to-node exchange is precalculated to reduce the effective number of nodes and reducing run time of the CAP program. The method is applied to four distinct conditions and is found to be suitable for the analysis of internal self-contamination. Cold traps, venting, and vacuumlike design are factors which are found to be important for cold-sensitive sensors.

Barengoltz, Jack B.↗

NGC 4314. I - Visible and short-wavelength infrared surface photometry of the nucleus and bar

BVI (TI CCD) and JHK (University of Texas IR Camera) surface photometry of NGC 4314, an SB (rs)ap anemic spiral with a nuclear ring containing recent star formation, is presented. The shortwave IR (SWIR) frames reveal a nuclear bar of length 2 arcsec at PA of 0 deg. The nuclear ring and associated dust were detected in all SWIR color indices. A nuclear spiral was detected in the visible and SWIR just exterior to the ring. Extremely low-amplitude spiral-shaped deficits were found in the stellar distribution in the SWIR in this same region. These are attributed to dust, since CO is detectable at or near these locations. Average minor-axis profiles show this galaxy to have a nuclear bulge obeying the de Vaucouleurs r exp 1/4 law for values in the range 2-7 arcsec. The extinction and scattering characteristics of dust near the sites of recent star formation in the nuclear ring are discussed.

Benedict, G. F.↗

X-ray transmission microscope development

This report covers the third 6 month period, from February 28, 1995 to August 31, 1995, under this contract. The main efforts during this period were the construction of the X-ray furnace, evaluation and selection of the CCD technology for the X-ray camera, solidification experiments with Al alloys and Al-zirconia composites in the prototype furnace, evaluation of specimens for the particle pushing flight experiment - PEPSI, measurements of emitted spectra from X-ray source, testing of the high resolution X-ray test targets, and the establishment of criteria for and selection of peripheral equipment. In addition to these tasks, two presentations were prepared in this period; one for the AIAA Microgravity Symposium and another for the Gordon Conference on Gravitational Effects in Pyisico-Chemical Systems.

Kaukler, William F.↗

WFC3 Calibration and Data Processing

Wide Field Camera 3 (WFC3), a panchromatic imager being developed for the Hubble Space Telescope (HST), is now fully integrated and over the past year has completed first rounds of extensive ground testing at Goddard Space Flight Center (GSFC), in both ambient and thermal-vacuum test environments. This report summarizes the results of those tests and describes the pipeline processing methods that will be used to calibrate WFC3 data. WFC3 is designed to ensure that the superb imaging performance of HST is maintained through the end of the mission and takes advantage of recent developments in detector technology to provide new and unique capabilities for HST. WFC3 contains ultraviolet/visible (UVIS) and near-infrared (IR) imaging channels, offering high sensitivity and wide field of view over the broadest wavelength range of any HST instrument. It is slated to replace the current Wide Field and Planetary Camera 2 during Servicing Mission 4. The WFC3 UVIS channel is based on elements from the Advanced Camera for Surveys (ACS)Wide Field Camera (WFC), with a 4096x4096 pixel Marconi CCD covering a 160x160 arcsecond field of view. The WFC3 UVIS channel is optimized for maximum sensitivity in the near-UV and contains a complement of 48 spectral filters and a grism. The WFC3 IR channel uses a 1024x1024 pixel HgCdTe Hawaii-1R detector array covering a 135x135 arcsecond field of view. The array sensitivity is optimized in the 0.8-1.7micron spectral range. The IR channel accomodates 15 filters and 2 grisms for slitless spectroscopy.

Bushouse, H.↗

Detection of atomic and molecular mega-electron-volt projectiles using an x-ray charged coupled device camera

We show that an x-ray charge coupled device (CCD) may be used as a particle detector for atomic and molecular mega-electron-volt (MeV) projectiles of around a few hundred keV per atomic mass unit. For atomic species, spectroscopic properties in kinetic energy measurements (i.e., linearity and energy resolution) are found to be close to those currently obtained with implanted or surface barrier silicon particle detectors. For molecular species, in order to increase the maximum kinetic energy detection limit, we propose to put a thin foil in front of the CCD. This foil breaks up the molecules into atoms and spreads the charges over many CCD pixels and therefore avoiding saturation effects. This opens new perspectives in high velocity molecular dissociation studies with accelerator facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the CCD development for the Dark Energy Spectroscopic Instrument

We describe improvements in CCD performance that have been achieved on 4k×4k, (15 μm)(2)-pixel, fully depleted CCDs for the Dark Energy Spectroscopic Instrument (DESI) [1]. With respect to our previous work on CCDs for the Dark Energy Camera and the Baryon Oscillation Spectroscopic Survey, our goals for the DESI CCD development were to improve read noise and quantum efficiency, improve the astrometric precision, and decrease pixel-size variations. We report experimental results on recently fabricated CCDs to be used in DESI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental performance evaluation of an advanced-design solid-state television camera

The development of an advanced-design black-and-white solid-state television camera which can survive exposure to space environmental conditions was undertaken. A 380 x 488 element buried-channel CCD is utilized as the image sensor to ensure compatibility with 525-line transmission and display equipment. Specific camera design approaches selected for study and analysis included: (1) component and circuit sensitivity to temperature; (2) circuit board thermal and mechanical design; and (3) CCD temperature control. Preferred approaches were determined and integrated into the final design for two deliverable solid-state TV cameras. One of these cameras was subjected to environmental tests to determine stress limits for exposure to vibration, shock, acceleration, and temperature-vacuum conditions. These tests indicate performance at the design goal limits can be achieved for most of the specified conditions.

Source record↗

PSF and MTF Measurement Methods for Thick CCD Sensor Characterization

Knowledge of the point spread function (PSF) of the sensors to be used in the Large Synoptic Survey Telescope (LSST) camera is essential for optimal extraction of subtle galaxy shape distortions caused by gravitational weak lensing. We have developed a number of techniques for measuring the PSF of candidate CCD sensors to be used in the LSST camera, each with its own strengths and weaknesses. The two main optical PSF measurement techniques that we use are the direct Virtual Knife Edge (VKE) scan as developed by Karcher, et al. and the indirect interference fringe method after Andersen and Sorensen that measures the modulation transfer function (MTF) directly. The PSF is derived from the MTF by Fourier transform. Other non-optical PSF measurement techniques that we employ include {sup 55}Fe x-ray cluster image size measurements and statistical distribution analysis, and cosmic ray muon track size measurements, but are not addressed here. The VKE technique utilizes a diffraction-limited spot produced by a Point-Projection Microscope (PPM) that is scanned across the sensor with sub-pixel resolution. This technique closely simulates the actual operating condition of the sensor in the telescope with the source spot size having an f/number close to the actual telescope design value. The interference fringe method uses a simple equal-optical-path Michelson-type interferometer with a single-mode fiber source that produces interference fringes with 100% contrast over a wide spatial frequency range sufficient to measure the MTF of the sensor directly. The merits of each measurement technique and results from the various measurement techniques on prototype LSST sensors are presented and compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced optical position sensors for magnetically suspended wind tunnel models

A major concern to aerodynamicists has been the corruption of wind tunnel test data by model support structures, such as stings or struts. A technique for magnetically suspending wind tunnel models was considered by Tournier and Laurenceau (1957) in order to overcome this problem. This technique is now implemented with the aid of a Large Magnetic Suspension and Balance System (LMSBS) and advanced position sensors for measuring model attitude and position within the test section. Two different optical position sensors are discussed, taking into account a device based on the use of linear CCD arrays, and a device utilizing area CID cameras. Current techniques in image processing have been employed to develop target tracking algorithms capable of subpixel resolution for the sensors. The algorithms are discussed in detail, and some preliminary test results are reported.

Lafleur, S.↗

NASA's Orbital Debris Optical Program: MCAT Operational on Ascension

The Orbital Debris Program Office at NASA Johnson Space Center has a long history of an optical observational program. The Meter Class Autonomous Telescope, MCAT, was dedicated to Eugene Stansbery (now also known as ES-MCAT) in 2017. MCAT, a 1.3m DFM telescope, has a proven capability for tracking known objects from Low-Earth Orbits (LEO) out to Geosynchronous (GEO) orbits. Monitoring the population of the GEO belt is accomplished through surveys. A GEO survey statistically samples the GEO belt (0 to ~15 deg orbital inclinations) to detect both correlated and uncorrelated targets. A GEO survey, the initial focus for MCAT, will commence in 2019 to map out the current state of the GEO population as input for the ORbital Debris Engineering Model (ORDEM 4.x). If a break-up occurs, surveys of the break-up field can be followed for discovery and investigations of daughter debris fragments from the parent satellite. Discovery can be accomplished by surveying orbits near to and including the parent object’s orbit. Targeted observations of debris can be taken with a suite of broadband filters for characterizing individual objects by rate-tracking their known or calculated orbital elements (Two-Line Element sets, TLEs). These observations can be used in conjunction with NASA’s Standard Satellite Break-up Model (SSBM). In 2018, MCAT’s primary mirror was realuminized with a high-end protected, enhanced silver ZeCoat and the CCD chip was replaced in the Spectral Instruments camera. With these updates completed, MCAT is now well on track to reach Full Operational Capability (FOC) in 2019 for its survey and rate-track capabilities. A full overview of MCAT’s operational state, capabilities, and mission will be discussed.

Orbital Debris Program↗