At least 865 records · Page 48

Modeling the interfacial failure and resulting mechanical properties of z-pinned additively manufactured composites

The mechanical properties of Fused Filament Fabrication (FFF) parts are limited in the build direction, albeit advantages such as design flexibility and in-house customization. Here, in this paper, a novel z-pinning approach that enhances mechanical properties in the build direction by depositing material across multiple layers within the part was investigated through numerical simulations and validated experimentally. A finite element model for z-pinned composite structures was developed by assigning fiber-orientation dependent material properties obtained using a micromechanics approach to beads and pins. The bead-to-bead and pin-to-pin adhesions within the z-pinned structures were modeled using a cohesive traction separation law. The properties of cohesive elements for carbon fiber-reinforced polylactic acid (CF-PLA) z-pinned composites were calibrated using tensile experiments. The elastic modulus and tensile strength of CF-PLA z-pinned composites in the build direction were predicted with the developed numerical model. The numerical investigation on various geometrical parameters revealed that the largest pin volume increases the stiffness and tensile strength by 40% and thus, has the greatest influence on the mechanical properties of the z-pinned composites. The effect of z-pin geometrical parameters on the mechanical properties was summarized to aid in the design of z-pinned additively manufactured composite structures.

36 MATERIALS SCIENCE↗

Development of multifunctional nylon 6,6-based nanocomposites with high electrical and thermal conductivities by scalable melt and dry blending methods for automotive applications

With the advent of intelligent automobile technology, the demand for multifunctional composites with higher electrical and thermal conductivities is increasing. We have herein reported for the first time the effect of polyolester on the dispersion of carbon nanotube (CNT) in the short-carbon fiber (CF)/nylon 6,6 (PA66) composite using a scalable melt-mixing and dry-blending method and its subsequent improvement in electrical and thermal conductivities. Masterbatches were prepared with a higher concentration of CNT (both untreated and polyolester-treated) followed by dry blended with reference composite (30 wt% CF and 10 wt% mineral fiber filled PA66) before making coupons via injection molding. A 500% and 63% improvements in electrical (3.14 S cm -1 ) and thermal conductivities (in-plane) (1.99 W m -1 K -1 ) conductivities were observed by adding 1.5 wt% treated CNT compared to the reference composite. The improvements were even higher than that of untreated CNT due to better dispersion. Furthermore, the electromagnetic shielding effectiveness reached 61 dB for 1.5 wt% treated CNT-filled composite (39% enhancement). In conclusion, these results are significant in imparting multiple functionalities to the automotive composite parts.

36 MATERIALS SCIENCE↗

Nuclear Data Sheets for A = 93

Nuclear structure data pertaining to all nuclei with mass number A=93 (Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo, Tc, Ru, Rh, Pd, Ag) have been compiled and evaluated and incorporated into the ENSDF data file. This publication for A=93 supersedes the previous publication by C.M. Baglin, Nuclear Data Sheets80, 1 (1997) (literature cutoff date November 1996) and subsequent revisions by C.M. Baglin of the ENSDF files for 93Br and {sup 93}Kr (literature cutoff 26 February 2001) and for {sup 93}Rh (literature cutoff 27 February 2001); it includes all data available prior to 15 December 2010. Significant changes since prior evaluations include the following: 2010Hw03 identified several high-spin states in {sup 93}Kr in {sup 252}Cf SF decay; in addition to the many low-spin levels already known in {sup 93}Rb from {beta}{sup -} decay, several higher-spin states have now been identified in a {sup 252}Cf SF decay study (2009Hw03); this SF decay has also been used to identify additional states in {sup 93}Sr (2003Hw01) and the {sup 238}U({sup 82}Se,X{gamma}) reaction (2007Bu35) has provided new information on {sup 93}Y. (HI,xn{gamma}) reaction studies have expanded our knowledge of the structure of {sup 93}Zr (2002Fo03, 2005Pa48), {sup 93}Nb (2007Wa45), {sup 93}Mo (2005Fu01), {sup 93}Tc (2003Ha22) and {sup 93}Pd (2004So04,2004Ru02). Considerable information on {sup 93}Nb was provided by a (p,2n{gamma}) study (2010Or01, 2006Or09, 2007Or01). The level schemes of {sup 93}Ru, {sup 93}Rh and {sup 93}Pd have undergone the most extensive revision thanks to studies of {sup 93}Rh {epsilon} decay (2004De40), {sup 94}Ag {epsilon}p decay (2004Mu30) and {sup 94}Ag p decay (2005Mu15, 2005Mu30), respectively. The half-life of the Zr member of this chain is of particular interest because of {sup 93}Zr's large contribution to long-term activity of nuclear reactor waste and also due to its potential as a supernova chronometer. During 2010, two new well-documented measurements of T{sub 1/2}({sup 93}Zr) were published (2010Ya01 and 2010Ca01); one agrees well with an earlier, undocumented measurement but, unfortunately, the other is many standard deviations lower for reasons which are not immediately apparent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VII.1 Nuclear Data for Science and Technology: Cross Sections, Covariances, Fission Product Yields and Decay Data

The ENDF/B-VII.1 library is our latest recommended evaluated nuclear data file for use in nuclear science and technology applications, and incorporates advances made in the five years since the release of ENDF/B-VII.0. These advances focus on neutron cross sections, covariances, fission product yields and decay data, and represent work by the US Cross Section Evaluation Working Group (CSEWG) in nuclear data evaluation that utilizes developments in nuclear theory, modeling, simulation, and experiment. The principal advances in the new library are: (1) An increase in the breadth of neutron reaction cross section coverage, extending from 393 nuclides to 423 nuclides; (2) Covariance uncertainty data for 190 of the most important nuclides, as documented in companion papers in this edition; (3) R-matrix analyses of neutron reactions on light nuclei, including isotopes of He, Li, and Be; (4) Resonance parameter analyses at lower energies and statistical high energy reactions for isotopes of Cl, K, Ti, V, Mn, Cr, Ni, Zr and W; (5) Modifications to thermal neutron reactions on fission products (isotopes of Mo, Tc, Rh, Ag, Cs, Nd, Sm, Eu) and neutron absorber materials (Cd, Gd); (6) Improved minor actinide evaluations for isotopes of U, Np, Pu, and Am (we are not making changes to the major actinides {sup 235,238}U and {sup 239}Pu at this point, except for delayed neutron data and covariances, and instead we intend to update them after a further period of research in experiment and theory), and our adoption of JENDL-4.0 evaluations for isotopes of Cm, Bk, Cf, Es, Fm, and some other minor actinides; (7) Fission energy release evaluations; (8) Fission product yield advances for fission-spectrum neutrons and 14 MeV neutrons incident on {sup 239}Pu; and (9) A new decay data sublibrary. Integral validation testing of the ENDF/B-VII.1 library is provided for a variety of quantities: For nuclear criticality, the VII.1 library maintains the generally-good performance seen for VII.0 for a wide range of MCNP simulations of criticality benchmarks, with improved performance coming from new structural material evaluations, especially for Ti, Mn, Cr, Zr and W. For Be we see some improvements although the fast assembly data appear to be mutually inconsistent. Actinide cross section updates are also assessed through comparisons of fission and capture reaction rate measurements in critical assemblies and fast reactors, and improvements are evident. Maxwellian-averaged capture cross sections at 30 keV are also provided for astrophysics applications. We describe the cross section evaluations that have been updated for ENDF/B-VII.1 and the measured data and calculations that motivated the changes, and therefore this paper augments the ENDF/B-VII.0 publication 'ENDF/B-VII.0: Next Generation Evaluated Nuclear Data Library for Nuclear Science and Technology,' Nuclear Data Sheets 107, 2931 (2006).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a new method for measurement of neutron detector efficiency up to 20 MeV

A new approach to neutron detector efficiency has been taken. A neutron detector has been calibrated with a 252 Cf source at low energy. The calibration can be extended to energies above 8 MeV based on the 252 Cf results. The techniques uses the fact that the cross section for a symmetric reaction with nucleus of atomic number A yielding a final nucleus with atomic number (2A-1) and a neutron A + A → (2A – 1) + n. This reaction must be symmetric about 90° in the center-of-mass system. Furthermore, the laboratory energies for the neutrons at the paired energies differ substantially. Thus, an efficiency known at one of the two angles can be used to determine the efficiency to higher energies or, for a negative Q, to lower neutron energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A=243

We present available information pertaining to the nuclear structure of all nuclei with mass numbers A=243. Various decay and reaction data are evaluated and compared. Adopted data, levels, spin, parity and configuration assignments are given. When there are insufficient data, expected values from systematics of nuclear properties or/and theoretical calculations are quoted. Unexpected or discrepant experimental results are also noted. A summary and compilation of the discovery of various isotopes in this mass region is given in 2013Fr02 ( 243 Np, 243 Pu, 243 Am, 243 Cm, 243 Bk, and 243 Cf), 2011Me01 ( 243 Es), and 2013Th02 ( 243 Fm).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 235

Spectroscopic data and level schemes from radioactive decay and nuclear reaction studies are presented here for all nuclei with mass number A=235. The highlight of this evaluation consists of the precise and comprehensive Coulomb excitation study (2012Wa35) on {sup 235}U, which in addition to the 7/2[743] ground state rotational band, extended the 1/2[631], 5/2[622], 5/2[752], and 3/2[631] rotational bands up to Jπ=53/2+, 49/2+, 441/2−, and 43/2+, respectively. This evaluation presents a study (2010Hu02) of the {sup 237}Np({sup 116}Sn, {sup 118}Snγ) reaction where the ground state rotational band 5/2[642] was observed up to Jπ=(53/2+). It is worth for historical knowledge to mention the report on the “Discovery of isotopes of the transuranium elements with 93≤Z≤98” (2013Fr02), where the information for elements Np, Pu, and Am with mass number A=235 is given. {sup 235}Cf has not been observed. The alpha hindrance factors (HF) presented in this evaluation were calculated using values of the radius parameter (r{sub 0}) interpolated from those for even–even adjacent nuclei given by 1998Ak04.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 239

Spectroscopic data and level schemes from radioactive decay and nuclear reaction studies are presented here for all nuclei with mass number A=239. In general, a relatively small amount of new data on this mass chain has been reported since the previous evaluation in 2003. However, special evaluations, such as ''Database of prompt gamma rays from slow neutron–capture from elemental analysis'' (2007ChZX), have provided additional precise data for levels in 29 U. Also, new Coulomb excitation measurements in 239 Pu have extended the knowledge of the 1/2[631] rotational band up to Jπ=(55/2+)Jπ=(55/2+), and that of the octupole vibrational band up to Jπ=(53/2-)Jπ=(53/2-). For historical knowledge it is worth mentioning the report on the “Discovery of isotopes of the transuranium elements with 93 <= Z <= 98'' (2013Fr02), where the information for elements Np, Pu, Am, and Cf with mass number A=239 is presented. The alpha hindrance factors (HF) presented in this evaluation were calculated using values of the radius parameter (r 0 ) interpolated from those for even–even adjacent nuclei given by 1998Ak04.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Need for Precise and Well-documented Experimental Data on Prompt Fission Neutron Spectra from Neutron-induced Fission of {sup 239}Pu

The spectrum of neutrons emitted promptly after {sup 239}Pu(n,f)—a so-called prompt fission neutron spectrum (PFNS)—is a quantity of high interest, for instance, for reactor physics and global security. However, there are only few experimental data sets available that are suitable for evaluations. In addition, some of those data sets differ by more than their 1-σ uncertainty boundaries. We present the results of MCNP studies indicating that these differences are partly caused by underestimated multiple scattering contributions, over-corrected background, and inconsistent deconvolution methods. A detailed uncertainty quantification for suitable experimental data was undertaken including these effects, and test-evaluations were performed with the improved uncertainty information. The test-evaluations illustrate that the inadequately estimated effects and detailed uncertainty quantification have an impact on the evaluated PFNS and associated uncertainties as well as the neutron multiplicity of selected critical assemblies. A summary of data and documentation needs to improve the quality of the experimental database is provided based on the results of simulations and test-evaluations. Given the possibly substantial distortion of the PFNS by multiple scattering and background effects, special care should be taken to reduce these effects in future measurements, e.g., by measuring the {sup 239}Pu PFNS as a ratio to either the {sup 235}U or {sup 252}Cf PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stand-alone and Network Capable Pocket Radiation Detection System

A multi-functional and networked pocket radiation detection system has been developed at the Idaho National Laboratory (INL) capable of detecting and storing gamma ray and neutron data. The device can be used as a stand-alone device or in conjunction with an array to cover a small or large area. The device has programmable alarm trigger levels that can be modified for specific applications. The data is stored with a date/time stamp and can be transferred and viewed on a PDA via direct connection or, in networked configuration, wireless connection to a remote central facility upon request. Data functional/bench tests have been completed successfully and the device was demonstrated to detect radiation from a 55.6 uCi Cf-252 source at 5 meters and from 1.4 mCi Cf-252 source at 10 meters which exceeds both ANSI and IAEA standards for pocket radiation detection. In terms of sensitivity, this detection system detects neutron and gamma-ray fields down to 10 micro rem/hr levels and therefore can find the location of the radioactive source quickly. The detection system is small enough to be put in a pocket or clipped to a belt.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A method to measure prompt fission neutron spectrum using gamma multiplicity tagging

In order to improve on current prompt fission neutron spectrum measurements, a gamma multiplicity tagging method was developed at the Rensselaer Polytechnic Institute Gearttner Linear Accelerator Center. This method involves using a coincidence requirement on an array of BaF 2 gamma detectors to determine the timing of a fission event. This allows for much larger fission samples to be used due to the higher penetrability of gammas compared to fission fragments. Additionally, since the method relies on gammas as opposed to fission fragments, the effects of the low level discriminator, used in fission chambers to eliminate alpha events, are not seen. A 252 Cf fission chamber was constructed in order to determine the viability of this method as well as the efficiency when compared to a fission chamber. The implemented multiple gamma tagging method was found to accurately reproduce the prompt fission neutron spectrum for the spontaneous fission of 252 Cf and to detect 30% of fission events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic liquid scintillation detector shape and volume impact on radiation portal monitors

We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3 He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm “paddle” shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. As a result, a small number of organic liquid scintillation detectors could therefore be a valid alternative to 3 He in some RPM applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron angular distribution in plutonium-240 spontaneous fission

Nuclear safeguards applications require accurate fission models that exhibit prompt neutron anisotropy. We observed an anisotropic neutron angular distribution, in the laboratory reference frame, because prompt fission neutrons carry momentum from fully accelerated fission fragments. Furthermore, a liquid organic scintillation detector array was used with pulse shape discrimination techniques to produce neutron-neutron cross-correlation time distributions and angular distributions from spontaneous fission in a 252 Cf, a 0.84 g 240 Pu eff metal, and a 1.63 g 240 Pu eff metal sample. The effect of cross-talk, estimated with MCNPX-PoliMi simulations, is removed from neutron-neutron coincidences as a function of the angle between detector pairs. Fewer coincidences were observed at detector angles near 90°, relative to higher and lower detector angles. As light output threshold increases, the observed anisotropy increases due to spectral effects arising from fission fragment momentum transfer to emitted neutrons. Stronger anisotropy was observed in Cf-252 spontaneous fission prompt neutrons than in Pu-240 neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated fission data measurements with DANCE and NEUANCE

To enhance the capabilities of the DANCE array, a new detector array NEUANCE was developed to enable simultaneous measurements of prompt fission neutrons and γ rays. NEUANCE was designed and constructed using 21 stilbene organic scintillator crystals. It was installed in the central cavity of the DANCE array. Signals from the 160 BaF 2 detectors of DANCE and the 21 detectors of NEUANCE were merged into a newly designed high-density high-throughput data acquisition system. The excellent pulse shape discrimination properties of stilbene enabled detection of neutrons with energy thresholds as low as 30–40 keVee. A fission reaction tagging method was developed using a NEUANCE γ-ray or neutron signal. The probability of detecting a neutron from the spontaneous fission of 252 Cf using NEUANCE is 47%. New correlated data for prompt fission neutrons and prompt fission rays were obtained for 252 Cf using this high detection efficiency experimental setup. In conclusion, average properties of prompt fission neutron emission as a function of prompt fission γ-ray quantities were also obtained, suggesting that neutron and γ-ray emission in fission are correlated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors

The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum 252Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is 4.8+0.7-0.9% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at ~4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to ~75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.

dark matter, detector calibration, ionization yiel↗

Event-by-event neutron–photon multiplicity correlations in 252Cf(sf)

Excited nuclear fragments are emitted during nuclear fission. The de-excitation of these fission fragments takes place as sequential emission of neutrons followed by photons. A correlation between neutron and photon multiplicities accompanying fission is thus expected. Fission event generators based on established statistical nuclear physics models predict a negative event-by-event correlation in neutron-photon multiplicity. A survey of published experimental results of an event-by-event covariance between the neutron - photon multiplicities emitted following the spontaneous fission of 252 Cf is presented. Analytic unfolding expressions are developed in this work to determine the bias introduced by background sources, particle misclassification, pulse pileup, and inelastic photon production. The published experimental data are re-analyzed using these unfolding techniques and are found to be in qualitative agreement with the predictions of model-based calculations. Finally, in particular, we have concluded that there exists a significant event-by-event neutron-photon emission competition following the spontaneous fission of 252 Cf.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗