Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMATICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Tune Determination of Strongly Coupled Betatron Oscillations in a Fast-Ramping Synchrotron

Tune identification -- i.e. attribution of the spectral peak to a particular normal de of oscillations -- can present a significant difficulty in the presence of strong transverse coupling when the normal mode with a lower damping rate dominates spectra of Turn-by-Turn oscillations in both planes. The introduced earlier phased sum algorithm helped to recover the weaker normal mode signal from the noise, but by itself proved to be insufficient for automatic peak identification in the case of close phase advance distribution in both planes. To resolve this difficulty we modified the algorithm by taking and analyzing Turn-by-Turn data for two different ramps with the beam oscillation excited in each plane in turn. Comparison of relative amplitudes of Fourier components allows for correct automatic tune identification. The proposed algorithm was implemented in the Fermilab Booster B38 console application and successfully used for tune, coupling and chromaticity measurements.

43 PARTICLE ACCELERATORS↗

Kinetics of Solid-Solid Phase Transition in Iron (u)

Previously, dynamic experiments on iron have observed a non-zero transition time and width in the solid-solid {alpha}-{var_epsilon} phase transition. Using Proton Radiography at the los Alamos Neutron Science Center, we have performed plate impact experiments on iron to further study the {alpha}-{var_epsilon} phase transition which occurs at 13GPa. A 40mm bore powder gun was coupled to a proton radiography beam line and imaging system and synchronized to the impact of the projectile on the target sample with the proton beam pattern. A typical experimental configuration for the iron study, as shown below in 3 color-enhanced radiographs, is a 40mm diameter aluminum sabot impacting a 40mm diameter of polycrystalline ARMCO iron. The iron is backed by a sapphire optical window for velocimetry measurements. The aluminum flyer on the left of the iron is barely visible for visual display purposes. Direct density jumps were measured which corresponded to calculations to within 1% using a Wondy multi-phase equation of state model. In addition, shock velocities were measured using an edge fitting technique and followed that edge movement from radiograph to radiograph, where rad iographs are separated in time by 500 ns. Preliminary measurements give a shock velocity (P1 wave) of 5.251 km/s. The projectile velocity was 0.725 km/s which translate to a peak stress of 17.5 GPa. Assuming the P1 wave is instantaneous, we are able to calibrate the chromatic, motion, object and camera blur by measuring the width of the P1 wave. This approximation works in this case since each of the two density jumps are small compared to the density of the object. Subtracting the measured width of the P1 wave in quadrature from the width of the P2 wave gives a preliminary measurement of the transition length of 265 {micro}m. Therefore, a preliminary measured phase transition relaxation time {tau} = transition length/u{sub s} = 265 {micro}m/5.251 km/s = 50 ns. Both Boettger1 & Jensen2 conclude that the transition rate and likely the transition mechanisms depend on the impact stress and the sample thickness. Since Proton Radiography can measure directly the transition length as well as the shock velocity, a transition time can be directly calculated. We propose to perform a series of experiments to measure the phase transition relaxation time, 1, as a function of drive, sample size and crystal orientation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Saltstone Oxidation Study: Leaching Method

Cementitious waste forms can be designed to chemically stabilize selected contaminants, such as Tc{sup +7} and Cr{sup +6}, by chemically reduction to lower valance states, Tc{sup +4} and Cr{sup +3}, respectively, and precipitation of these species in alkaline media as low solubility solid phases. Data for oxidation of this type of cementitious waste form cured under field conditions as a function of time is required for predicting the performance of the waste form and disposal facility. The rate of oxidation (oxidation front advancement) is an important parameter for predicting performance because the solubilities of some radionuclide contaminants, e.g., technetium, are a function of the oxidation state. A non-radioactive experiment was designed for quantifying the oxidation front advancement using chromium, as an approximate redox-sensitive surrogate (Cr{sup +6} / Cr{sup +3}) for technetium (Tc{sup +7} / Tc{sup +4}). Nonradioactive cementitious waste forms were prepared in the laboratory and cured under both laboratory and ?field conditions.? Laboratory conditions were ambient temperature and sealed sample containers. Field conditions were approximated by curing samples in open containers which were placed inside a plastic container stored outdoors at SRS. The container had a lid and was instrumented with temperature and humidity probes. Subsamples as thin as 0.2 mm were taken as a function of distance from the exposed surface of the as-cast sample. The subsamples were leached and the leachates were analyzed for chromium, nitrate, nitrite and sodium. Nitrate, nitrite, and sodium concentrations were used to provide baseline data because these species are not chemically retained in the waste form matrix to any significant extent and are not redox sensitive. ?Effective? oxidation fronts for Cr were measured for samples containing 1000, 500 and 20 mg/kg Cr added as soluble sodium chromate, Na{sub 2}CrO{sub 4}. For a sample cured for 129 days under field conditions, leachable Cr (assumed to be the oxidized form, i.e., Cr{sup +6} was detected in the top 15 to 20 mm of the sample spiked with 1000 mg/kg Cr. Below about 20 mm, the Cr concentrations in leachates were below the detection limit (< 0.010 mg/L) which indicates that the oxidation as the result of exposure to air was limited to the top 20 mm of the sample after exposure for 129 days and that the bulk of the waste form was not affected, i.e., the Cr was stabilized and insoluble. For samples cured in the laboratory, leachable Cr was detected in the top 8 mm of the Cr 1000 sample cured in the laboratory for 37 days. Between 8 and 14 mm, the concentration Cr in the leachate dropped by a factor of about 20 to just above the detection limit. These depth of penetration results indicate that the rate of advancement of the oxidation front for samples spiked with 1000 mg/kg Cr cured under ?field conditions? for 129 days is less than that for the sample cured in the laboratory for 37 days, i.e., 0.156 and 0.216 mm/day, respectively. Additional data are presented for samples spiked with 500 and 20 mg/kg Cr. In summary, cementitious waste forms are porous solids with a network of interconnected pores ranging in diameter from 10E-10 m to greater than a few mm. The oxidation process is assumed to occur as the result of oxygen transport through the interconnected porosity which may be filled with air, aqueous salt solution, or both. Upon oxidation, the Cr becomes soluble and can be transported in solution through aqueous pore fluid or leachate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spatial Brightness Perception of Trichromatic Stimuli

An experiment was conducted to examine the effect of tuning optical radiation on brightness perception for younger (18-25 years of age) and older (50 years of age or older) observers. Participants made forced-choice evaluations of the brightness of a full factorial of stimulus pairs selected from two groups of four metameric stimuli. The large-field stimuli were created by systematically varying either the red or the blue primary of an RGB LED mixture. The results indicate that light stimuli of equal illuminance and chromaticity do not appear equally bright to either younger or older subjects. The rank-order of brightness is not predicted by any current model of human vision or theory of brightness perception including Scotopic to Photopic or Cirtopic to Photopic ratio theory, prime color theory, correlated color temperature, V(λ)-based photometry, color quality metrics, linear brightness models, or color appearance models. Age may affect brightness perception when short-wavelength primaries are used, especially those with a peak wavelength shorter than 450 nm. The results suggest further development of metrics to predict brightness perception is warranted, and that including age as a variable in predictive models may be valuable.

Brightness perception↗

Charged Particle Optics in Circular Higgs Factory

Similar to a super B-factory, a circular Higgs factory will require strong focusing systems near the interaction points and a low-emittance lattice in arcs to achieve a factory luminosity. At electron beam energy of 120 GeV, beamstrahlung effects during the collision pose an additional challenge to the collider design. In particular, a large momentum acceptance at 2 percent level is necessary to retain an adequate beam lifetime. This turns out to be the most challenging aspect in the design of circular Higgs factory. In this paper, an example will be provided to illustrate the beam dynamics in circular Higgs factory, emphasizing on the chromatic optics. Basic optical modules and advanced analysis will be presented. Most important, we will show that 2% momentum aperture is achievable

43 PARTICLE ACCELERATORS↗

Failure Mechanisms and Color Stability in Light-Emitting Diodes during Operation in High- Temperature Environments in Presence of Contamination

The energy efficiency of light-emitting diode (LED) technology compared to incandescent light bulbs has triggered an increased focus on solid state luminaries for a variety of lighting applications. Solid-state lighting (SSL) utilizes LEDs, for illumination through the process of electroluminescence instead of heating a wire filament as seen with traditional lighting. The fundamental differences in the construction of LED and the incandescent lamp results in different failure modes including lumen degradation, chromaticity shift and drift in the correlated color temperature. The use of LED-based products for safety-critical and harsh environment applications necessitates the characterization of the failure mechanisms and modes. In this paper, failure mechanisms and color stability has been studied for commercially available vertical structured thin film LED (VLED) under harsh environment conditions with and without the presence of contaminants. The VLED used for the study was mounted on a ceramic starboard in order to connect it to the current source. Contamination sources studied include operation in the vicinity of vulcanized rubber and adhesive epoxies in the presence of temperature and humidity. Performance of the VLEDs has been quantified using the measured luminous flux and color shift of the VLEDs subjected to both thermal and humidity stresses under a forward current bias of 350 mA. Results indicate that contamination can result in pre-mature luminous flux degradation and color shift in LEDs.

Lall, Pradeep↗

Method and apparatus for control of coherent synchrotron radiation effects during recirculation with bunch compression

A modulated-bending recirculating system that avoids CSR-driven breakdown in emittance compensation by redistributing the bending along the beamline. The modulated-bending recirculating system includes a) larger angles of bending in initial FODO cells, thereby enhancing the impact of CSR early on in the beam line while the bunch is long, and 2) a decreased bending angle in the final FODO cells, reducing the effect of CSR while the bunch is short. The invention describes a method for controlling the effects of CSR during recirculation and bunch compression including a) correcting chromatic aberrations, b) correcting lattice and CSR-induced curvature in the longitudinal phase space by compensating T.sub.566, and c) using lattice perturbations to compensate obvious linear correlations x-dp/p and x'-dp/p.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical conversion coating for protecting magnesium alloys from corrosion

A chromate-free, self-healing conversion coating solution for magnesium alloy substrates, composed of 10-20 wt. % Mg(NO.sub.3).sub.2.6H.sub.2O, 1-5 wt. % Al(NO.sub.3).sub.3.9H.sub.2O, and less than 1 wt. % of [V.sub.10O.sub.28].sup.6- or VO.sub.3.sup.- dissolved in water. The corrosion resistance offered by the resulting coating is in several hundreds of hours in salt-spray testing. This prolonged corrosion protection is attributed to the creation of a unique structure and morphology of the conversion coating that serves as a barrier coating with self-healing properties. Hydroxoaluminates form the backbone of the barrier protection offered while the magnesium hydroxide domains facilitate the "slow release" of vanadium compounds as self-healing moieties to defect sites, thus providing active corrosion protection.

36 MATERIALS SCIENCE↗

Parameter Estimation of Gaussian-Damped Sinusoids from a Geometric Perspective

The five parameter gaussian damped sinusoid equation is a reasonable model for betatron motion with chromatic decoherence of the proton bunch centroid signal in the ring at the Spallation Neutron Source. A geometric method for efficiently fitting this equation to the turn by turn signals to extract the betatron tune and damping constant will be presented. This method separates the parameters into global and local parameters and allows the use of vector arithmetic to eliminate the local parameters from the parameter search space. Furthermore, this method is easily generalized to reduce the parameter search space for a larger class of problems.

97 MATHEMATICS AND COMPUTING↗

Resistive Wall Growth Rate Measurements in the Fermilab Recycler

Impedance could represent a limitation of running high intensity beams in the Fermilab recycler. With high intensity upgrades foreseen, it is important to quantify the impedance. To do this,studies have been performed measuring the growth rate of presumably the resistive wall instability. The growth rates at varying intensities and chromaticities are shown. The measured growth rates are compared to ones calculated with the resistive wall impedance.

Ainsworth, R.↗

Influence of Magnet Multipole Field Components on Beam Dynamics in the JLEIC Ion Collider Ring

To get a luminosity level of a few 10 33 cm -2 ses ₋1 at all design points of the Jefferson Lab Electron Ion Collider (JLEIC) project, small β* values in both horizontal and vertical planes are necessary at the Interaction Point (IP) in the ion collider ring. This also means large β in the final focus area, chromaticity correction sections, etc. which sets a constraint on the field quality of magnets in large beta areas, in order to ensure a large enough dynamic aperture (DA). In this context, limiting multipole field components of magnets are surveyed to find a possible compromise between the requirements and what can be realistically achieved by a magnet manufacturer. This paper describes that work. Moreover, non-linear field dedicated correctors are also studied to provide semi-local corrections of specific multipole field components.

Wei, Guohui↗

Final 6D Muon Ionization Colling using Strong Focusing Quadrupoles

Abstract Low emittance muon beam lines and muon colliders are potentially a rich source of BSM physics for future exper- imenters. A muon beam normalized emittance of ax,y,z = (280, 280, 1570)µm has been achieved in simulation with short solenoids and a betatron function of 3 cm. Here we use ICOOL and MAD-X to explore using a 400 MeV/c muon beam and strong focusing quadrupoles to achieve a normalized transverse emittance of 100 µm and complete 6D cooling. The low beta regions, as low as 5 mm, produced by the quadrupoles are occupied by dense, low Z absorbers, such as lithium hydride or beryllium, that cool the beam transversely. Equilibrium transverse emittance is linearly proportional to the transverse betatron function. Reverse emittance exchange with septa and/or wedges is then used to decrease transverse emittance from 100 to 25 µm at the expense of longitudinal emittance for a high energy lepton collider. Cooling challenges include chromaticity correction, ssband overlap, quadrupole acceptance, and staying in phase with RF.

43 PARTICLE ACCELERATORS↗

Design Considerations for Proposed Fermilab Integrable RCS

Integrable optics is an innovation in particle accelerator design that provides strong nonlinear focusing while avoiding parametric resonances. One promising application of integrable optics is to overcome the traditional limits on accelerator intensity imposed by betatron tune-spread and collective instabilities. The efficacy of high-intensity integrable accelerators will be undergo comprehensive testing over the next several years at the Fermilab Integrable Optics Test Accelerator (IOTA) and the University of Maryland Electron Ring (UMER). We propose an integrable Rapid-Cycling Synchrotron (iRCS) as a replacement for the Fermilab Booster to achieve multi-MW beam power for the Fermilab high-energy neutrino program. We provide a overview of the machine parameters and discuss an approach to lattice optimization. Integrable optics requires arcs with integer-pi phase advance followed by drifts with matched beta functions. We provide an example integrable lattice with features of a modern RCS - long dispersion-free drifts, low momentum compaction, superperiodicity, chromaticity correction, separate-function magnets, and bounded beta functions.

43 PARTICLE ACCELERATORS↗

Preliminary Experimental Investigation of Quasi Achromat scheme at Advanced Photon Source

Next generation storage rings require weaker dipolemagnets and stronger quadrupole focusing to achieve very low emittance. To suppress the geometric and chromatic optics aberrations introduced by the strong sextupoles, achromat and quasi achromat schemes are applied in the lattice design to improve the beam dynamics performance. In this paper, some preliminary experimental investigation of the quasi achromat scheme at the Advanced Photon Source (APS) are presented. Three different operation lattices are compared on their beam dynamics performance. Although none of these operation lattices achieve ideal quasi achromat condition, they have certain relevant features. It is observed that fewer resonances are present in the nominal operation lattice which is most close to quasi achromat required conditions.

Sun, Yipeng↗

LAMP2GO

The app is a unique image analysis software and acts as a fluorescence reader for multiplexed nucleic acid amplification reactions. If the reaction is positive, a bright fluorescent signal is emitted from the solution depending on the choice of fluorophore molecule. The app reads the Red, blue and green (RGB) channels of the emitted signal and transforms it to yield the chromaticity (x and y) and luminance of the signal. This new representation of signal is far superior to the RGB system in determining the signal color and intensity.

Priye, Aashish↗

Generating Low Beta Regions with Quadrupoles for Final Muon Cooling

Muon beams and colliders are rich sources of new physics, if muons can be cooled. A normalized rms transverse muon emittance of 280 microns has been achieved in simulation with short solenoids and a betatron function of 3 cm. Here we use ICOOL, G4beamline, and MAD-X to explore using a 400 MeV/c muon beam and strong focusing quadrupoles to approach a normalized transverse emittance of 100 microns and finish 6D muon cooling. The low beta regions produced by the quadrupoles are occupied by dense, low Z absorbers, such as lithium hydride or beryllium, that cool the beam. Equilibrium transverse emittance is linearly proportional to the beta function. Reverse emittance exchange with septa and/or wedges is then used to decrease transverse emittance from 100 to 25 microns at the expense of longitudinal emittance for a high energy lepton collider. Work remains to be done on chromaticity correction.

43 PARTICLE ACCELERATORS↗

An Overview of Broadband Laser Ranging (BLR) Architecture and Measurement Considerations

Broadband Laser Ranging (BLR) is a developmental diagnostic intended to measure the position of rapidly moving surfaces in combination with optical velocimetry. Design and employment of a BLR diagnostic on dynamic experiments requires consideration for both the inherent measurement system tradeoffs as well as architectural choices appropriate to the nature of investigation. The diagnostic uses spectral interferometry to measure distance by mapping femtosecond laser pulses to the time domain via chromatic dispersion within the fiber-optic architecture. The system parameters and governing equations that describe measurement range, resolution, and Doppler sensitivity will be discussed. We will also briefly review the impact of diagnostic architectural choices including: nature of interferometer, Interferometric dispersion matching, optical amplification, integration of optical velocimetry, BLR calibration, and field operability. To summarize we will present the architectural and operational approach currently being pursued by NSTec within an on-going collaboration between NSTec, Lawrence Livermore and Los Alamos National Labs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostic Use of Neutron-Sensitive Image Plates at ORNL Neutron Facilities

Neutron facilities at the ORNL provide a versatile suite of instruments to the neutron scattering community. Neutron-sensitive imaging plates are useful when characterizing neutron beamlines at the SNS and HFIR facilities. We describe a number of characterization, commissioning, and troubleshooting measurements in which we use neutron-sensitive image plates to better understand and improve instrument performance. We have used image plates to characterize neutron beams in many ways: to determine absolute beam size, assess transverse beam distribution, and to measure absolute intensity. During the initial radiation survey of the new US/Japan Cold Triple Axis instrument (CTAX), images of the beam footprint were taken multiple monochromator assembly angles. Images of the CTAX beam footprint showed a secondary beam spot, indicating a misalignment in the monochromator. Measurements at the Fine-Resolution Fermi Chopper Spectrometer (SEQUOIA) instrument for 400, 300, 250 and 120meV provide beam size and relative intensity. We frequently use image plates to verify sample alignment within a neutron beam prior to data acquisition. Finally, we measured the absolute intensity across a very large (20cm by 30cm) mono- chromatic beam with a combination of image plates and a conventional beam monitor on the Fundamental Physics beam line. While there are limitations to the data obtained from image plates, especially on pulsed sources, when combined with other tools, they can provide more depth to beamline analysis and development.

Geoghegan, Ceris↗