Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

SISTec: Mathematical Calibration of Large Clearance Monitors - 18265

One major path for clearance of large amount of waste arising from the decommission of nuclear power plants is based on measurement with large clearance monitors (also known as free release measurement facilities). These devices utilize multi-detector plastic scintillator arrays (large clearance monitors can consist of up to 24 plastic scintillators) to offer both, extremely low minimum detectable activities (MDA) and short measurement times for waste packages weighing up to one metric ton. However, a major problem with these devices is to obtain nuclide specific efficiencies, especially for geometrically complex large waste packages. Normal procedure for estimating the efficiency is to device dummy waste packages and attach point sources with well-known activities to unfavourable positions in these packages. In accordance with this procedure, calibration factors can be derived in a radiological conservative way. Devising such test dummies is not always possible and the procedure is prone to generating large measurement uncertainties. In this publication, we propose a new method to derive calibration factors by means of the Los Alamos National Laboratory (LANL) simulation tool Monte Carlo N-Particle (MCNP) and a statistical-phenomenological model for the detector characterization. In a multi-step approach, first the detector response for a distribution of activity in a waste package is calculated and subsequently the detectors are mathematically characterized. Applying state of the art statistical and optimizing procedures, parameters for the detector response are derived in a self-consistent way. This also allows to rigorously propagate the uncertainties to the final calculated calibration factors according to the Guide to the Expression of Uncertainty in Measurement (GUM supplement 1). To validate the derived parameters for the detector characterization a minimally invasive experimental setup was devised and installed into the large clearance monitor. It consisted of an aluminum swivel arm which could position point sources to the relevant coordinates. The so collected measurement data not only allowed to investigate the precision of the calculated calibration factors, but also to probe the location of concentrated activity sources in the waste package. Furthermore, data on measurements with dummy waste packages were collected to test the reproducibility of well-known calibration factors. We present the software tool SIStec, which will provide an intuitive user-interface to generate and simulate waste package models and execute the above-mentioned method. Using SIStec, different scenarios for the distribution of activity in the waste package can be probed. This will also allow to optimize the clearance process on various levels. For example, measurement time for pre-measurements can be reduced in exchange for unfavourable calibration factors, which would still allow to meet the regulator limits for clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calibration of Raman Spectrometer for Gas Phase Measurements

Raman spectroscopy is currently used at SRNL to measure the concentration of gaseous species evolved from chemical reactions. This report documents the methods used to calibrate the spectroscopic systems in both frequency and intensity spaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Solar Radiation Research Laboratory (SRRL) Final Report: Fiscal Years 2019-2021

The Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m 2 ) for the United States, which is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two International Organization for Standardization (ISO)/International Electrotechincal Commission (IEC) 17025 calibration facilities that provide unique, high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop: improved methods for the calibration of solar radiometers; new standards through the ISO, the IEC, and ASTM International; models; advanced instrumentation and methods for operating solar measurement stations. The SRRL data sets are also critical for the validation of new models and data sets, such as the National Solar Radiation Database (NSRDB).

14 SOLAR ENERGY↗

Comparison of Analytical Methods for the Determination of Uranium in Seawater Using Inductively Coupled Plasma Mass Spectrometry

Trace element determinations in seawater by inductively coupled plasma mass spectrometry are analytically challenging due to the typically very low concentrations of the trace elements and the potential interference of the salt matrix. In this study, we did a comparison for uranium analysis using inductively coupled plasma mass spectrometry (ICP-MS) of Sequim Bay seawater samples and three seawater certified reference materials (SLEW-3, CASS-5 and NASS-6) using seven different analytical approaches. The methods evaluated include: direct analysis, Fe/Pd reductive precipitation, standard addition calibration, online automated dilution using an external calibration with and without matrix matching, and online automated pre-concentration. The method which produced the most accurate results was the method of standard addition calibration, recovering uranium from a Sequim Bay seawater sample at 101 ± 1.2%. The on-line preconcentration method and the automated dilution with matrix-matched calibration method also performed well. The two least effective methods were the direct analysis and the Fe/Pd reductive precipitation using sodium borohydride

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within {+-}1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A NEW METHOD TO QUANTIFY X-RAY SUBSTRUCTURES IN CLUSTERS OF GALAXIES

We present a new method to quantify substructures in clusters of galaxies, based on the analysis of the intensity of structures. This analysis is done in a residual image that is the result of the subtraction of a surface brightness model, obtained by fitting a two-dimensional analytical model ({beta}-model or Sersic profile) with elliptical symmetry, from the X-ray image. Our method is applied to 34 clusters observed by the Chandra Space Telescope that are in the redshift range z in [0.02, 0.2] and have a signal-to-noise ratio (S/N) greater than 100. We present the calibration of the method and the relations between the substructure level with physical quantities, such as the mass, X-ray luminosity, temperature, and cluster redshift. We use our method to separate the clusters in two sub-samples of high- and low-substructure levels. We conclude, using Monte Carlo simulations, that the method recuperates very well the true amount of substructure for small angular core radii clusters (with respect to the whole image size) and good S/N observations. We find no evidence of correlation between the substructure level and physical properties of the clusters such as gas temperature, X-ray luminosity, and redshift; however, analysis suggest a trend between the substructure level and cluster mass. The scaling relations for the two sub-samples (high- and low-substructure level clusters) are different (they present an offset, i.e., given a fixed mass or temperature, low-substructure clusters tend to be more X-ray luminous), which is an important result for cosmological tests using the mass-luminosity relation to obtain the cluster mass function, since they rely on the assumption that clusters do not present different scaling relations according to their dynamical state.

79 ASTRONOMY AND ASTROPHYSICS↗

Practical Weak-lensing Shear Measurement with Metacalibration

Metacalibration is a recently introduced method to accurately measure weak gravitational lensing shear using only the available imaging data, without need for prior information about galaxy properties or calibration from simulations. The method involves distorting the image with a small known shear, and calculating the response of a shear estimator to that applied shear. The method was shown to be accurate in moderate-sized simulations with galaxy images that had relatively high signal-to-noise ratios, and without significant selection effects. In this work we introduce a formalism to correct for both shear response and selection biases. We also observe that for images with relatively low signal-to-noise ratios, the correlated noise that arises during the metacalibration process results in significant bias, for which we develop a simple empirical correction. To test this formalism, we created large image simulations based on both parametric models and real galaxy images, including tests with realistic point-spread functions. We varied the point-spread function ellipticity at the five-percent level. In each simulation we applied a small few-percent shear to the galaxy images. We introduced additional challenges that arise in real data, such as detection thresholds, stellar contamination, and missing data. We applied cuts on the measured galaxy properties to induce significant selection effects. Using our formalism, we recovered the input shear with an accuracy better than a part in a thousand in all cases.

79 ASTRONOMY AND ASTROPHYSICS↗

Uncertainty Quantification via Stable Distribution Propagation

We propose a new approach for propagating stable probability distributions through neural networks. Our method is based on local linearization, which we show to be an optimal approximation in terms of total variation distance for the ReLU non-linearity. This allows propagating Gaussian and Cauchy input uncertainties through neural networks to quantify their output uncertainties. To demonstrate the utility of propagating distributions, we apply the proposed method to predicting calibrated confidence intervals and selective prediction on out-of-distribution data. The results demonstrate a broad applicability of propagating distributions and show the advantages of our method over other approaches such as moment matching.

Artificial Intelligence (cs.AI)↗

Semi-Empirical Calibration Technique for the MSE Diagnostic on the JET and DIII-D Tokamaks

Calibration of the MSE diagnostic is technically straightforward but complicated by a number of practical considerations that potentially introduce systematic errors. We have developed a semi-empirical method to optimize calibrations that is based on constraining the calibration to agree with equilibria derived from simple current-ramp discharges. The optimized calibrations quantitatively improve the equilibrium reconstructions and yield good agreement between the onset of a variety of MHD phenomena and the predicted appearance of corresponding mode rational surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NSLS-II Storage Ring BPM Calibration via LOCO

In the following, we describe a method of the beam based calibration of the beam position monitor (BPM) system in the NSLS-II storage ring (SR) via the LOCO (Linear Optics from Closed Orbits) technique. This method measures the orbit response matrix (ORM) and the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Therefore, BPM gains and rolls are obtained.

36 MATERIALS SCIENCE↗

Solar Radiation Research Laboratory (SRRL) Core Project Final Report: Fiscal Years 2022-2024

The Solar Radiation Research Laboratory (SRRL) at the National Laboratory of the Rockies (NLR) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m2) for the United States that is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two calibration facilities that meet International Standards Organization-17025 (ISO-17025) standards and provide unique high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System (BMS) at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop (1) improved methods for the calibration of solar radiometers; (2) new standards through the ISO, the International Electrotechnical Commission (IEC), and the American Standards for Testing of Materials (ASTM) International; (c) solar radiation and meteorological models; and (d) advanced instrumentation and methods for operating solar measurement stations. The SRRL datasets are also critical for the validation of new models and datasets, such as the National Solar Radiation Database (NSRDB). The research and development of solar radiation measurement systems and resource modeling techniques are essential for advancing the scientific basis for producing reliable resource data. Specifically, the spatial, temporal, and spectral (wavelength dependency) characteristics of the solar resource are required in several different time frames for various project phases.

14 SOLAR ENERGY↗

Overdestabilization vs Overstabilization in the Theoretical Analysis of f-Orbital Covalency

The complex nature of the f-orbital electronic structures and their interaction with the chemical environment pose significant computational challenges. Advanced computational techniques that variationally include scalar relativities and spin–orbit coupling directly at the molecular orbital level have been developed to address this complexity. Among these, variational relativistic multiconfigurational multireference methods stand out for their high accuracy and systematic improvement in studies of f-block complexes. Additionally, these advanced methods offer the potential for calibrating low-scaling electronic structure methods such as density functional theory. However, studies on the Cl K-edge X-ray absorption spectra of the [Ce(III)Cl 6 ] 3– and [Ce(IV)Cl 6 ] 2– complexes show that time-dependent density functional theory with approximate exchange–correlation kernels can lead to inaccuracies, resulting in an overstabilization of 4f orbitals and incorrect assessments of covalency. In contrast, approaches utilizing small active space wave function methods may understate the stability of these orbitals. The results herein demonstrate the need for large active space, multireference, and variational relativistic methods in studying f-block complexes.

chemical calculations↗

Monitoring the Caustic Dissolution of Aluminum Alloy in a Radiochemical Hot Cell Using Raman Spectroscopy

Chemical processing of highly radioactive materials commonly takes place in heavily shielded hot cells. The remote, real-time monitoring of chemical processing streams via optical spectroscopic techniques in hot cells may be particularly useful. Here in this paper, we describe the implementation of Raman spectroscopy and chemometric analysis to monitor the dissolution of aluminum-clad targets containing irradiated aluminum–neptunium oxide cermet pellets in caustic solutions in a hot cell environment. Partial least squares regression analysis was used to generate calibration models to quantify the concentration of dissolved aluminum, nitrate, and hydroxide in solutions within the radiochemical hot cell. This work explored a systematic approach to optimize a matrix of calibration standards using a D-optimal experimental design. The Design of Experiments-based regression model, in comparison to more traditional analytical approaches, was found to be the more practical method for building calibration models, with fewer samples, to obtain informative analytical data from Raman spectra.

36 MATERIALS SCIENCE↗

Recalibrating Best Practices, Challenges, and Limitations of Estimating Tree Transpiration Via Sap Flow

Purpose: Transpiration dominates hydrologic fluxes from terrestrial ecosystems to the atmosphere. Sap flow is the most widely used method to quantify transpiration, and calibrations can improve the accuracy of these estimates. Despite numerous suggestions to perform and apply sap flow calibrations, seemingly few reports apply these recommendations. Here, we sought to determine the prevalence of calibration across sap flow methodology. Recent Findings: In this work, we reviewed tree sap flow literature over the past nine years and determined that only 5.3% of these publications documented the performance of calibrations, the application of coefficients from previous calibrations, or the application of correction factors using calibration data to ensure or improve accuracy of transpiration estimates. These data indicate that calibration has not been adopted as a best practice. However, these data may also reflect challenges to the performance and application of calibration indicating fundamental limitations of sap flow methods. Summary: We highlight the need for testing critical assumptions regarding calibration; specifically, that coefficients derived from calibrations on small stems are suitable for application to large stems and that different calibration approaches yield similar transpiration estimates. We encourage researchers to adopt calibration as a best practice for sap flow data and to explain how calibration was performed, how calibration data were applied, and to acknowledge and justify circumstances that preclude or do not necessitate calibration. Without the adoption of calibration and an improved understanding of its limitations, our understanding of transpiration and ability to quantify it using this technology will remain inadequate.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-263: Development of Dose Monitor Unit Calculation Using Clarkson Integration for Proton Beam Therapy Using Beam-Wobbling System

Purpose: The purpose of the present study is to develop a calculation method of dose-calibration-factor using Clarkson integration for proton therapy employing the wobbling system and to evaluate accuracy of the calculation by comparison between calculations and measurements. Methods: CF and CALF stand for a dose-calibration-factor and a dose per monitor unit (MU), respectively. A measured dose-calibration-factor CFmeas is defined as a ratio of the measured dose per monitor unit in a patient-specific condition CALFpat to the measured dose per MU in a reference beam condition CALFref. The CFcalc is a product of three factors: CF1, CF2 and CF3. The CF1 and CF2 are a factor reflecting the effect of common beam delivery devices and that of patient specific devices and parameter (an aperture collimator, a range compensator and an air gap), respectively. The CF1 was obtained by interpolation using measured data. The CF2 was calculated using the Simplified Monte Carlo (SMC) method. The SMC method calculates a dose distribution by tracing individual protons and by using a measured Bragg curve in water. The CF3 representing the correction factor of field size effect was obtained by using the Clarkson integration. We compared the calculated and measured CF values for 20 prostate cases. Results: Field size correction was found to be important. The calculations reproduce the measurement results within an error of ±2.0%, except for a few cases. The error was about –3.1% for the small field area of less than19 square centimeters. Conclusion: We have developed a calculation method of dose-calibration-factor. Calculations agreed with measurements within ±2.0% for 90% of 20 prostate cases. Except for a small field size cases, the calculation method can be applied to determine the dose-calibration–factor for majority cases of prostate cancer.

60 APPLIED LIFE SCIENCES↗

Ultrasonic in-situ water-cut measurement using ultrasonic oil-water separation for affecting sound speed calibration

An apparatus and method for the separation of an oil-water mixture into its components are described. An acoustic radiation force moves oil droplets to the nodes of an acoustic standing wave generated in a vertical column containing the oil-water mixture. Once the droplets are sufficiently close together, attractive forces become dominant and the droplets may coalesce to form larger droplets, which have greater buoyancy, and separation of the mixture into a layer of oil and a layer of water occurs, not possible by simple gravitational separation. Acoustically-driven oil-water separation may be used for water-cut measurements in oil production wells, since separation of the oil from the water permits accurate sound speed measurements to be made for both the oil and the water, thereby allowing frequent in situ calibrations of the apparatus to determine whether sound speed measurements on the mixture are accurate in the event that one or both of the mixture constituents is changing.

02 PETROLEUM↗