Search NASA⌕ Search

SEARCH · Search NASA

Results for “Color Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Technical Note: Homogeneity of Gafchromic EBT2 film

Purpose: The self-developing Gafchromic EBT film is a radiochromic film, widely used for relative photon dosimetry. Recently, the manufacturer has replaced the well-investigated EBT film by the new Gafchromic EBT2 film. It has the same sensitive component and, in addition, it contains a yellow marker dye in order to protect the film against ambient light exposure and to serve as a base for corrections of small differences in film response. Furthermore, the configuration of the film layers as well as the binder material have been changed in comparison to the EBT film. When investigating the properties of EBT2 film, all characteristics were found to be similar to those of EBT film, except for the film response homogeneity. Thus, in this article special focus was put on examining the homogeneity of EBT2 film. Methods: A scan protocol established for EBT film and published previously was used. The uniformity of the film coloration was investigated for unirradiated and irradiated EBT2 film sheets. The dose response of EBT2 film was measured and the influence of film inhomogeneities on dose determination was evaluated. Results: Inhomogeneities in pixel values of up to {+-}3.7% within one film were detected. The relative inhomogeneities were found to be approximately independent of the dose. Nonuniformities of the film response lead to uncertainties in dose determination of {+-}8.7% at 1 Gy. When using net optical densities for dose calibration, uncertainties in dose determination amount to more than {+-}6%. Conclusions: EBT2 films from the lot investigated in this study show response inhomogeneities, which lead to uncertainties in dose determination exceeding the commonly accepted tolerance levels. It is important to test further EBT2 lots regarding homogeneity before using the film in clinical routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-453: Image-Guided Patient-Specific Quality Assurance for Multi-Target Single Isocenter Intracranial VMAT Radiosurgery

Purpose: To demonstrate a patient specific, image-guided quality assurance method that tests both dosimetric and geometric accuracy for single-isocenter multiple-target VMAT radiosurgery (SIMT-VMAT-SRS) Method: We used a new film type, EBT-XD (optimal range 0.4–40Gy), and an in-house PMMA phantom having a coronal plane for film and a 0.125 cm3 ionization chamber (IC). The phantom contained fiducial features for kV image guided setup and for accurate film marking. Five patient plans with multiple targets sizes ranging from 3 to 21mm in diameter and prescribed doses from 14 to 18 Gy were selected. Two verification plans were generated for each case with the film plane passing through the center of the largest and smallest targets. For the four largest targets we obtained an IC measurement. For each case, a calibration film was irradiated using a custom designed step pattern. The films were scanned using a flatbed color scanner and converted to dose using the calibration film and the three channel calibration method. Image registration was performed between film and treatment planning system calculations to evaluate the geometric accuracy. Results: The mean registration vector had an average magnitude of 0.47 mm (range from 0.13mm to 0.64 mm). For the four largest targets, the mean ratio of the IC and film measurement to expected dose was 0.990 (range 0.968 to 1.009) and 1.032 (1.021 to 1.046), respectively. The fraction of pixels having gamma index < 1 for criteria of 3%/3mm, 3%/2mm, 3%/1mm was 98.8%, 97.5% and 87.2% before geometric registration and 99.1%, 98.3% and 94.8% after registration. Conclusion: We have demonstrated an image-guided QA method can assess both geometric and dosimetric accuracy. The phantom was positioned with sub-millimeter accuracy. Absolute film dosimetry using EBT-XD film was sufficiently accurate for assessment of dose to multi-targets too small for IC measurement in SRS VMAT plans.

60 APPLIED LIFE SCIENCES↗

Experiment to evaluate feasibility of utilizing Skylab-EREP remote sensing data for tectonic analysis of the Bighorn Mountains region, Wyoming-Montana

The author has identified the following significant results. Analysis of SL-3, S-190A, and S-190B color frames indicates two sets of linears obliquely cutting across the east-west trending Owl Creek-Bridger uplifts. A northwest set of faults and folds has been mapped previously but the imagery indicates some changes and addition of detail can be made. A less pronounced east-northeast set of linear alignments (drainage segments, lithologic contacts, possible faults) extends into the southeast part of the Big Horn Basin.

Hoppin, R. A.↗

Video systems for real-time oil-spill detection

Three airborne television systems are being developed to evaluate techniques for oil-spill surveillance. These include a conventional TV camera, two cameras operating in a subtractive mode, and a field-sequential camera. False-color enhancement and wavelength and polarization filtering are also employed. The first of a series of flight tests indicates that an appropriately filtered conventional TV camera is a relatively inexpensive method of improving contrast between oil and water. False-color enhancement improves the contrast, but the problem caused by sun glint now limits the application to overcast days. Future effort will be aimed toward a one-camera system. Solving the sun-glint problem and developing the field-sequential camera into an operable system offers potential for color 'flagging' oil on water.

Millard, J. P.↗

Remote sensing of effects of land use practices on water quality

An intensive study was conducted to determine the utility of manual densitometry and color additive viewing of aircraft and LANDSAT transparencies for monitoring land use and land use change. The relationship between land use and selected water quality parameters was also evaluated. Six watersheds located in the Cumberland Plateau region of eastern Kentucky comprised the study area for the project. Land uses present within the study area were reclaimed surface mining and forestry. Fertilization of one of the forested watersheds also occurred during the study period.

Graves, D. H.↗

A comparison of remote sensing techniques for Minnesota wetlands classification

A wetland classification study in a typically complex 650 sq km test site in east central Minnesota compared the time, cost and accuracy of manually interpreted 1:24,000 scale color infrared aerial photographs with digital analysis of Landsat data. The comparison was between the same general wetland and non-wetland classes; accuracy of both systems was evaluated with intensive ground verification. For the same general classes, the overall mapping accuracy was 96 percent for the aerial photo interpretation and 71 percent for Landsat double-date classification. Results with maximum likelihood and SECHO classifiers were the same, 71 percent, while mapping accuracy with a layered classifier was only 66 percent. Compared to a general geometric correction and a single-date data set, geographic position and classification accuracy improved when a precision geometric correction and a double-date data set were used. Landsat digital analysis was faster, 24 vs. 90 days, but photointerpretation was more economical at $0.15/hectare (including all costs of procurement, processing and analysis), compared with Landsat costs of $0.35/hectare (not including costs of data procurement, processing prior to delivery to user and related overhead).

Werth, L. F.↗

Pulse-echo ultrasonic imaging method for eliminating sample thickness variation effects

A pulse-echo, immersion method for ultrasonic evaluation of a material is discussed. It accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer, automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjusments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.

Roth, Don J.↗

Development of an Automated Reader for Analysis and Storage of Personnel Dosimeter Badge Data

The collection and archiving of data from personnel dosimeters has become increasingly important in light of the lowered Threshold Limit Values (TLV) for HydraZine (HZ), MonoMethylHydrazine (MMH), and Unsymmetrical DiMethylHydrazine (UDMH). The American Conference of Government Industrial Hygienists (ACGIH) lowered the TLV from 100 parts per billion (ppb) to IO ppb and has caused increased concern over long term exposures of personnel to trace levels of these hypergols and other potentially harmful chemicals. An automated system of reading the exposure levels of personnel dosimeters and storing exposure data for subsequent evaluation has been developed. The reading of personnel dosimeter badges for exposure to potentially harmful vapor concentrations of hydrazines or other chemicals is performed visually by comparing the color developed by the badge with a calibrated color comparator. The result obtained using visual comparisons of the developed badge color with the comparator may vary widely from user to user. The automated badge reader takes the variability out of the dosimeter reading by accurately comparing the reflectance obtained from a colored spot on the badge with a reading on the same spot prior to any exposure to chemical vapors. The observed difference between the reflectance values is used as part of a calculation of the dose value for the badge based on a stored calibration curve. The badge reader also stores bar-code data unique to each badge, as well as bar-code information on the user, as part of the permanent badge record. The start and stop exposure times for each badge are recorded and can be used as part of the calculated concentration, in ppm, for each badge logged during a recording period. The badge reader is equipped with a number of badge holders, each of which is unique to a specific type of personnel dosimeter badge. This gives the reader maximum flexibility to allow for the reading of several different types of badges. Test results of the badge reader for several different types of personnel dosimeter badges are presented within the body of this paper.

Meneghelli, B. J.↗

Development of an Automated Reader for Analysis and Storage of Personnel Dosimeter Badge Data

The collection and archiving of data from personnel dosimeters has become increasingly important in light of the lowered threshold limit values (TLV) for hydrazine (HZ), monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH). The American Conference of Government Industrial Hygienists (ACGIH) lowered the TLV from 100 parts per billion (ppb) to 10 ppb and has caused increased concern over long term exposures of personnel to trace levels of these hypergols and other potentially harmful chemicals. An automated system of reading the exposure levels of personnel dosimeters and storing exposure data for subsequent evaluation has been developed. The reading of personnel dosimeter badges for exposure lo potentially harmful vapor concentrations of hydrazines or other chemicals is performed visually by comparing the color developed by the badge with a calibrated color comparator. The result obtained using visual comparisons of the developed badge color with the comparator may vary widely from user to user. The automated badge reader takes the variability out of the dosimeter reading by accurately comparing the reflectance obtained from a colored spot on the badge with a reading on the same spot prior to any exposure to chemical vapors. The observed difference between the reflectance values is used as part of a calculation of the dose value for the badge based on a stored calibration curve. The badge reader also stores bar-code data unique to each badge, as well as bar-code information on the user, as part of the permanent badge record. The start and stop exposure times for each badge are recorded and can be used as part of the calculated concentration, in ppm, for each badge logged during a recording period. The badge reader is equipped with a number of badge holders, each of which is unique to a specific type of personnel dosimeter badge. This gives the reader maximum flexibility to allow for the reading of several different types of badges. Test results of the badge reader for several different types of personnel dosimeter badges are presented within the body of this paper.

Meneghelli, B. J.↗

Pulse-Echo Ultrasonic Imaging Method for Eliminating Sample Thickness Variation Effects

A pulse-echo, immersion method for ultrasonic evaluation of a material which accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer and automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjustments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.

Roth, Don J.↗

OCTS and SeaWiFS Bio-Optical Algorithm and Product Validation and Intercomparison in US Coastal Waters

Monitoring the health of US coastal waters is an important goal of the National Oceanic and Atmospheric Administration (NOAA). Satellite sensors are capable of providing daily synoptic data of large expanses of the US coast. Ocean color sensors, in particular, can be used to monitor the water quality of coastal waters on an operational basis. To appraise the validity of satellite-derived measurements, such as chlorophyll concentration, the bio-optical algorithms used to derive them must be evaluated in coastal environments. Towards this purpose, over 21 cruises in diverse US coastal waters have been conducted. Of these 21 cruises, 12 have been performed in conjunction with and under the auspices of the NASA/Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project. The primary goal of these cruises has been to obtain in-situ measurements of downwelling irradiance, upwelling radiance, and chlorophyll concentrations in order to evaluate bio-optical algorithms that estimate chlorophyll concentration. In this Technical Memorandum, we evaluate the ability of five bio-optical algorithms, including the current Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) algorithm, to estimate chlorophyll concentration in surface waters of the South Atlantic Bight (SAB). The SAB consists of a variety of environments including coastal and continental shelf regimes, Gulf Stream waters, and the Sargasso Sea. The biological and optical characteristics of the region is complicated by temporal and spatial variability in phytoplankton composition, primary productivity, and the concentrations of colored dissolved organic matter (CDOM) and suspended sediment. As such, the SAB is an ideal location to test the robustness of algorithms for coastal use.

Brown, Christopher W.↗

Dynamic color mapping with a multi-scale histogram: A design study with physical scientists

Many research and development activities for scientific data analysis have focused on scalability challenges and data-driven features. Conversely, data visualization that focus on models requiring human interaction rarely involve practical and largescale scientific data analysis. Therefore, a gap exists between interactive data visualization and scientific data analysis applications. In this paper, we present a design study of interactive data visualization to support scientists who visually analyze data from neutron scattering experiments. This study was conducted in multiple phases: 1) problem characterization; 2) initial design and formative evaluation; and 3) iterative design. We characterize the problems and the design requirements for the analysis of the specific physical science data. We discuss the design, development, evaluation of our visual analytics tool and as well as our iterative developments with physical scientists. We show how to bridge the gap between the two disciplines uncovering new potential to solve their challenges in this design study. We focus on a specific challenge, finding an optimal color mapping, which plays a critical role in neutron scattering science and is broadly applicable to other scientific domains. To address the challenge, we propose two interactive visualization techniques: a dynamic color scale bar (DCSB) and a multi-scale histogram (MSH).

Chae, Junghoon↗

Image Provenance Analysis

The literature of multimedia forensics is mainly dedicated to the analysis of single assets (such as sole image or video files), aiming at individually assessing their authenticity. Different from this, image provenance analysis is devoted to the joint examination of multiple assets, intending to ascertain their history of edits, by evaluating pairwise relationships. Each relationship, thus, expresses the probability of one asset giving rise to the other, through either global or local operations, such as data compression, resizing, color-space modifications, content blurring, and content splicing. The principled combination of these relationships unveils the provenance of the assets, also constituting an important forensic tool for authenticity verification. This chapter introduces the problem of provenance analysis, discussing its importance and delving into the state-of-the-art techniques to solve it.

Moreira, Daniel↗

A tracking system to calculate patient skin dose in real-time during neurointerventional procedures using a biplane x-ray imaging system

Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. Conclusions: The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries.

60 APPLIED LIFE SCIENCES↗

Processing corrections for Skylab photographic imagery

Camera filters were inadvertently omitted from the six-channel multispectral photographic camera (S190A) during the exposure of the first roll of film from each channel on the final manned Skylab mission. Each of the films was overexposed and degraded as a result of the filter omissions. Explained are the techniques used by the NASA/JSC Photographic Technology Division to evaluate and process those films. These or similar techniques can be used in other photographic multispectral remote sensing applications in which black-and-white infrared and panchromatic or color infrared film are degraded due to loss of filtration or to overexposure. Results prove that data may be salvaged after camera exposure errors are made thus saving the expense of reacquiring data.

Lockwood, H. E.↗

Skylab experiment M487 habitability/crew quarters

Results of Skylab experiment M487 (habitability/crew quarters), which was designed to evaluate the habitability features of Skylab, were presented. General observations and conclusions drawn from the data obtained are presented in detail. The objectives of the experiment, the manner in which data was acquired, and the instruments used to support the experiments are described. Illustrations and photographs of the living and work areas of Skylab and some of the habitability features are provided. Samples of the subjective evaluation questionnaires used by the crewmen are included. Habitability-related documents, crewmen biographies, functional characteristics and photographs of the instruments used, and details of Skylab compartment sizes and color schemes are included as appendixes.

Johnson, C. C.↗

Breadboard wash water renovation system

A total wash water renovation system concept was developed for removing objectionable materials from spacecraft wash water in order to make the water reusable. The breadboard model system described provides for pretreatment with ferric chloride to remove soap by chemical precipitation, carbon adsorption to remove trace dissolved organics, and ion exchange for removal of dissolved salts. The entire system was put into continuous operation and carefully monitored to assess overall efficiency and equipment maintenance problems that could be expected in actual use. In addition, the capacity of the carbon adsorbers and the ion-exchange resin was calculated and taken into consideration in the final evaluation of the system adequacy. The product water produced was well within the Tentative Wash Water Standards with regard to total organic carbon, conductivity, urea content, sodium chloride content, color, odor, and clarity.

Source record↗

Development, implementation and evaluation of satellite-aided agricultural monitoring systems

Research supporting the use of remote sensing for inventory and assessment of agricultural commodities is summarized. Three task areas are described: (1) corn and soybean crop spectral/temporal signature characterization; (2) efficient area estimation technology development; and (3) advanced satellite and sensor system definition. Studies include an assessment of alternative green measures from MSS variables; the evaluation of alternative methods for identifying, labeling or classification targets in an automobile procedural context; a comparison of MSS, the advanced very high resolution radiometer and the coastal zone color scanner, as well as a critical assessment of thematic mapper dimensionally and spectral structure.

Cicone, R.↗