Search NASA⌕ Search

SEARCH · Search NASA

Results for “DISPLAY DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Donor–acceptor polymers with tunable infrared photoresponse

Donor–acceptor (DA) conjugated polymers provide an important platform for the development of solution-processed optoelectronic devices. The complex interrelation between electronic properties and conformational disorder in these materials complicates the identification of design guidelines to control the bandgap at low energies, limiting the design of new optoelectronic and device functionalities. Here, we demonstrate that DA polymers comprised of exocyclic olefin substituted cyclopentadithiophene donors, in combination with conventional electron acceptors, display very narrow optical bandgaps (1.2 > E opt g > 0.7 eV) and primary photoexcitations extending into the shortwave infrared. Theoretical calculations reveal fundamental structure–property relationships toward bandgap and energy level control in these spectral regions. Bulk heterojunction photodiodes fabricated using these new materials demonstrate a detectivity (D*) of > 10 11 Jones within a spectral range of 0.6–1.43 μm and measurable D* to 1.8 μm, the longest reported to date for conjugated polymer based systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Q silicon photonic crystal cavity for enhanced optical nonlinearities

We fabricate and experimentally characterize an H0 photonic crystal slab nanocavity with a design optimized for maximal quality factor, Q = 1.7 × 10{sup 6}. The cavity, fabricated from a silicon slab, has a resonant mode at λ = 1.59 μm and a measured Q-factor of 400 000. It displays nonlinear effects, including high-contrast optical bistability, at a threshold power among the lowest ever reported for a silicon device. With a theoretical modal volume as small as V = 0.34(λ/n){sup 3}, this cavity ranks among those with the highest Q/V ratios ever demonstrated, while having a small footprint suited for integration in photonic circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct measurement of the transition from edge to core power coupling in a light-ion helicon source

Here, we present time-resolved measurements of an edge-to-core power transition in a light-ion (deuterium) helicon discharge in the form of infra-red camera imaging of a thin stainless steel target plate on the Proto-Material Exposure eXperiment device. The time-resolved images measure the two-dimensional distribution of power deposition in the helicon discharge. The discharge displays a mode transition characterized by a significant increase in the on-axis electron density and core power coupling, suppression of edge power coupling, and the formation of a fast-wave radial eigenmode. Although the self-consistent mechanism that drives this transition is not yet understood, the edge-to-core power transition displays characteristics that are consistent with the discharge entering a slow-wave anti-resonant regime. RF magnetic field measurements made across the plasma column, together with the power deposition results, provide direct evidence to support the suppression of the slow-wave in favor of core plasma production by the fast-wave in a light-ion helicon source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Web Extensible Display Manager

Jefferson Lab's Web Extensible Display Manager (WEDM) allows staff to access EDM control system screens from a web browser in remote offices and from mobile devices. Native browser technologies are leveraged to avoid installing and managing software on remote clients such as browser plugins, tunnel applications, or an EDM environment. Since standard network ports are used firewall exceptions are minimized. To avoid security concerns from remote users modifying a control system, WEDM exposes read-only access and basic web authentication can be used to further restrict access. Updates of monitored EPICS channels are delivered via a Web Socket using a web gateway. The software translates EDM description files (denoted with the edl suffix) to HTML with Scalable Vector Graphics (SVG) following the EDM's edl file vector drawing rules to create faithful screen renderings. The WEDM server parses edl files and creates the HTML equivalent in real-time allowing existing screens to work without modification. Alternatively, the familiar drag and drop EDM screen creation tool can be used to create optimized screens sized specifically for smart phones and then rendered by WEDM.

Slominski, Ryan↗

The Last Big Bang

As one of the very few people in the world to give the “go/no go” decision to detonate a nuclear device, Austin “Mac” McGuire holds a very special place in the history of both the Los Alamos National Laboratory and the world. As Commander of Joint Task Force Unit 8.1.1, on Christmas Island in the spring and summer of 1962, Mac directed the Los Alamos data collection efforts for twelve of the last atmospheric nuclear detonations conducted by the United States. Since data collection was at the heart of nuclear weapon testing, it fell to Mac to make the ultimate decision to detonate each test device. He calls his experience THE LAST BIG BANG, since these tests, part of Operation Dominic, were characterized by the dramatic displays of the heat, light, and sounds unique to atmospheric nuclear detonations – never, perhaps, to be witnessed again.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Flight management - Pilot procedures and system interfaces for the 1980-1990's

In the air transportation system of the 1980-1990's, aircraft must perform with greater precision in time and position than is possible today. Rapid development in electronics technology makes renovation in airborne-system concepts feasible. The Ames Research Center is conducting research on pilot procedures and pilot-system interfaces for such systems. Research on various pilot-system interface devices and manned simulations was conducted to study rules of distributed decision making authority among pilots and controllers with various airborne display concepts, and a pilot-oriented command logic for the control of avionic systems was studied. Results are summarized, and ongoing work and future research plans described.

Wempe, T. E.↗

Temperature coefficients and radiation induced DLTS spectra of MOCVD grown n(+)p InP solar cells

The effects of temperature and radiation on n(+)p InP solar cells and mesa diodes grown by metallorganic chemical vapor deposition (MOCVD) were studied. It was shown that MOCVD is capable of consistently producing good quality InP solar cells with Eff greater than 19 percent which display excellent radiation resistance due to minority carrier injection and thermal annealing. It was also shown that universal predictions of InP device performance based on measurements of a small group of test samples can be expected to be quite accurate, and that the degradation of an InP device due to any incident particle spectrum should be predictable from a measurement following a single low energy proton irradiation.

Walters, Robert J.↗

Monitoring dynamic loads on wind tunnel force balances

Two devices have been developed at NASA Langley to monitor the dynamic loads incurred during wind-tunnel testing. The Balance Dynamic Display Unit (BDDU), displays and monitors the combined static and dynamic forces and moments in the orthogonal axes. The Balance Critical Point Analyzer scales and sums each normalized signal from the BDDU to obtain combined dynamic and static signals that represent the dynamic loads at predefined high-stress points. The display of each instrument is a multiplex of six analog signals in a way that each channel is displayed sequentially as one-sixth of the horizontal axis on a single oscilloscope trace. Thus this display format permits the operator to quickly and easily monitor the combined static and dynamic level of up to six channels at the same time.

Ferris, Alice T.↗

Summary Report of Mission Acceleration Measurements for STS-65, Launched 8 July 1994

The second flight of the International Microgravity Laboratory (IML-2) payload on board the STS-65 mission was supported by three accelerometer instruments: The Orbital Acceleration Research Experiment (OARE) located close to the orbiter center of mass; the Quasi-Steady Acceleration Measurement experiment, and the Space Acceleration Measurement System (SAMS), both in the Spacelab module. A fourth accelerometer, the Microgravity Measuring Device recorded data in the middeck in support of exercise isolation tests.Data collected by OARE and SAMS during IML-2 are displayed in this report. The OARE data represent the microgravity environment below 1 Hz. The SAMS data represent the environment in the 0.01 Hz to 100 Hz range. Variations in the environment caused by unique activities are presented. Specific events addressed are: crew activity, crew exercise, experiment component mixing activities, experiment centrifuge operations, refrigerator/freezer operations and circulation pump operations. The analyses included in this report complement analyses presented in other mission summary reports.

Rogers, Melissa J. B.↗

Bringing Control System User Interfaces to the Web

With the evolution of web based technologies, especially HTML5 [1], it becomes possible to create web-based control system user interfaces (UI) that are cross-browser and cross-device compatible. This article describes two technologies that facilitate this goal. The first one is the WebOPI [2], which can seamlessly display CSS BOY [3] Operator Interfaces (OPI) in web browsers without modification to the original OPI file. The WebOPI leverages the powerful graphical editing capabilities of BOY and provides the convenience of re-using existing OPI files. On the other hand, it uses generic JavaScript and a generic communication mechanism between the web browser and web server. It is not optimized for a control system, which results in unnecessary network traffic and resource usage. Our second technology is the WebSocket-based Process Data Access (WebPDA) [4]. It is a protocol that provides efficient control system data communication using WebSocket [5], so that users can create web-based control system UIs using standard web page technologies such as HTML, CSS and JavaScript. WebPDA is control system independent, potentially supporting any type of control system.

Chen, Xihui↗

Solution Phase Exciton Diffusion Dynamics of a Charge-Transfer Copolymer PTB7 and a Homopolymer P3HT

Using ultrafast polarization-controlled transient absorption (TA) measurements, dynamics of the initial exciton states were investigated on the time scale of tens of femtoseconds to about 80 ps in two different types of conjugated polymers extensively used in active layers of organic photovoltaic devices. These polymers are poly(3-fluorothienothiophenebenzodithiophene) (PTB7) and poly-3-hexylthiophene (P3HT), which are charge-transfer polymers and homopolymers, respectively. In PTB7, the initial excitons with excess vibrational energy display two observable ultrafast time constants, corresponding to coherent exciton diffusion before the vibrational relaxation, and followed by incoherent exciton diffusion processes to a neighboring local state after the vibrational relaxation. In contrast, P3HT shows only one exciton diffusion or conformational motion time constant of 34 ps, even though its exciton decay kinetics are multiexponential. Based on the experimental results, an exciton dynamics mechanism is conceived taking into account the excitation energy and structural dependence in coherent and incoherent exciton diffusion processes, as well as other possible deactivation processes including the formation of the pseudo-charge-transfer and charge separate states, as well as interchain exciton hopping or coherent diffusion.

36 MATERIALS SCIENCE↗

SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-optical active plasmonic devices with memory and power-switching functionalities based on {epsilon}-near-zero nonlinear metamaterials

We theoretically propose and numerically investigate an active plasmonic device made up of a nonlinear {epsilon}-near-zero metamaterial slab of thickness smaller than 100 nm lying on a linear {epsilon}-near-zero metamaterial substrate. We predict that in free-space coupling configuration the system operating at low intensity displays plasmon mediated hysteresis behavior. The phase difference between the reflected and the incident optical waves turns out to be multivalued and dependent on the history of the excitation process. Such an hysteresis behavior allows the proposed system to be regarded as a memory device whose state is accessible by measuring either the mentioned phase difference or the power, which is multivalued as well, carried by the nonlinear plasmon wave. Since multiple plasmon powers comprise both positive and negative values, the device also operates as a switch of the plasmon power direction at each jump along an hysteresis loop.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metal–Organic Framework-Derived CoWP@C Composite Nanowire Electrocatalyst for Efficient Water Splitting

Practical application of electrochemical water splitting demands durable, efficient, and non-noble metal catalysts for both hydrogen evolution reaction (HER) and oxygen evolution reaction (OER). Herein, we report a new hydrogen evolution nanowire electrocatalyst, consisting of S-doped CoWP nanoparticles embedded in S- and N-doped carbon matrix (S-CoWP@(S,N)-C), which is in situ transformed from Hofmann-type (Co, W)-based metal–organic framework (MOF) nanowires. Because of S and N doping to the carbon matrix and the S doping to CoWP nanoparticles, the obtained S-CoWP@(S,N)-C catalyst reaches a current density of -10 mA cm –2 at -35 and -67 mV (vs RHE) in acidic and alkaline electrolytes, respectively. Powered by a lead halide perovskite solar cell, an unassisted two-electrode solar water-splitting device using MOF-derived S-CoWP@(S,N)-C HER electrocatalysts and S-CoW@(S,N)-C OER electrocatalysts displays a solar-to-hydrogen conversion efficiency of 10.98%. Our method is highly applicable for developing robust electrocatalysts toward efficient and low-cost solar-driven water splitting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Size and Structural Control of Mechanoluminescent ZnS:Mn 2+ Nanocrystals for Optogenetic Neuromodulation

Mechanoluminescent materials hold immense potential for various transformative applications, from medical imaging and diagnostics to health monitoring and wearable displays. Conventionally produced as bulk powders or microparticles, they face significant size limitations for advanced applications, particularly in biological systems and microscale devices. Here, this work presents an approach to ZnS:Mn 2+ nanocrystal synthesis that involves self-assembly and subsequent calcination. In addition to effective size control within the nanoscale, this approach promotes the formation of abundant stacking faults, significantly enhancing piezoelectric and mechanoluminescent properties by increasing trap density and reducing trap depth. Unlike mechanoluminescent materials produced using conventional methods, these nanocrystals demonstrate strong mechanoluminescence without requiring UV pre-excitation, and the light emission persists even after mechanical stress is removed. These advantageous properties make them promising candidates for optogenetic neuromodulation, as they can effectively trigger electrical signals in neurons upon ultrasound stimulation both with and without UV pre-excitation. The persistent mechanoluminescence prolongs the duration of neuronal electrical activity, providing an extended temporal window for neuromodulation compared to conventional mechanoluminescent materials. This study provides a scalable method for producing efficient mechanoluminescent nanoparticles and reveals the crucial role of particle size and defect structures in determining their mechanoluminescent behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing the Effects of Electrode Crystallographic Orientation on Battery Electrochemistry via the Anisotropic Lithiation and Sodiation of ReS 2

Practical application of electrochemical water splitting demands durable, efficient, and non-noble metal catalysts for both hydrogen evolution reaction (HER) and oxygen evolution reaction (OER). Herein, we report a new hydrogen evolution nanowire electrocatalyst, consisting of S-doped CoWP nanoparticles embedded in S- and N-doped carbon matrix (S-CoWP@(S,N)-C), which is in situ transformed from Hofmann-type (Co, W)-based metal–organic framework (MOF) nanowires. Because of S and N doping to the carbon matrix and the S doping to CoWP nanoparticles, the obtained S-CoWP@(S,N)-C catalyst reaches a current density of -10 mA cm –2 at -35 and -67 mV (vs RHE) in acidic and alkaline electrolytes, respectively. Powered by a lead halide perovskite solar cell, an unassisted two-electrode solar water-splitting device using MOF-derived S-CoWP@(S,N)-C HER electrocatalysts and S-CoW@(S,N)-C OER electrocatalysts displays a solar-to-hydrogen conversion efficiency of 10.98%. Our method is highly applicable for developing robust electrocatalysts toward efficient and low-cost solar-driven water splitting.

25 ENERGY STORAGE↗

Numerical and laboratory simulations of auroral acceleration

The existence of parallel electric fields is an essential ingredient of auroral physics, leading to the acceleration of particles that give rise to the auroral displays. An auroral flux tube is modelled using electrostatic Vlasov simulations, and the results are compared to simulations of a proposed laboratory device that is meant for studies of the plasma physical processes that occur on auroral field lines. The hot magnetospheric plasma is represented by a gas discharge plasma source in the laboratory device, and the cold plasma mimicking the ionospheric plasma is generated by a Q-machine source. In both systems, double layers form with plasma density gradients concentrated on their high potential sides. The systems differ regarding the properties of ion acoustic waves that are heavily damped in the magnetosphere, where the ion population is hot, but weakly damped in the laboratory, where the discharge ions are cold. Ion waves are excited by the ion beam that is created by acceleration in the double layer in both systems. The efficiency of this beam-plasma interaction depends on the acceleration voltage. For voltages where the interaction is less efficient, the laboratory experiment is more space-like.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-162: Quality Assurance Procedures for MR Guided Focused Ultrasound Treatment of Bone Metastasis

Purpose: The purpose of this work is to develop and verify our quality assurance (QA) procedures to ensure the safety and efficacy of MR-guided focused ultrasound (MRgFUS) treatment of bone metastases. Methods: A practical QA program was developed. Monthly and daily QA (DQA) procedures were performed. The major QA items included the checks of the machine hardware, software and patient safety features. Briefly, these checks/tests include: 1) the cooling system reservoir and treatment table; 2) power to the treatment table; 3) the MR coil; 4) the transducer position with MRI; 5) image display on the treatment work station; 6) the effective focal spot in 3 directions using MR thermometry; and 7) all the safety devices including a sonication lamp, and the emergency stop-sonication switches. In order to avoid patient skin burn, it is important to remove gas bubbles in the interfaces between the treatment table and the gel pad, and the gel pad and patients skin during the patient setup. Our QA procedures have been verified and evaluated through patient treatments. Seven patients with scapula, humeral head, sacrum, ilium, pubic ramus and acetabular bone metastases were treated using MRgFUS. Results: Our study showed that all seven patients tolerated the MRgFUS treatment well. No skin toxicity or other complications were observed. The pain score (0–10) using the visual analog scale (VAS) was significantly reduced from 8.0 ± 1.1 before treatment to 4.7 ± 3.0, 3.0 ± 1.5, 3.2 ± 2.8 and 3.4 ± 1.5 at one day, one month, two months and three months after the MRgFUS treatment, respectively. Conclusion: We demonstrated that with the appropriate QA procedures, MRgFUS is a safe, effective and noninvasive treatment modality for palliation of bone metastases.

60 APPLIED LIFE SCIENCES↗