Search NASA⌕ Search

SEARCH · Search NASA

Results for “Depth sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Satellite and aircraft measurements of stratospheric aerosol particles

Data on the characteristics of the stratospheric aerosol as measured with sensors on the SAM II and SAGE I satellites and with ground-based and airborne lidar are discussed. Emphasis is placed on the impact of the El Chichon eruptions. The volcanic cloud was tracked to an altitude of 30 km, and was observed to travel around the earth in 3 weeks. The maximum stratospheric loading is estimated at 12 Mtons, which increased the stratospheric optical depth to 0.15-2.0 at the peak period. The particulate loading was predicted to lower the Northern Hemisphere average temperatures by 0.4-0.5 C in 1984-85.

Mccormick, M. P.↗

Direct Aerosol Radiative Forcing Based on Combined A-Train Observations: Towards All-sky Estimates and Attribution to Aerosol Type

We describe a technique for combining CALIOP aerosol backscatter, MODIS spectral AOD (aerosol optical depth), and OMI AAOD (absorption aerosol optical depth) measurements for the purpose of estimating full spectral sets of aerosol radiative properties, and ultimately for calculating the 3-D distribution of direct aerosol radiative forcing. We present results using one year of data collected in 2007 and show comparisons of the aerosol radiative property estimates to collocated AERONET retrievals. Initial calculations of seasonal clear-sky aerosol radiative forcing based on our multi-sensor aerosol retrievals compare well with over-ocean and top of the atmosphere IPCC-2007 model-based results, and with more recent assessments in the "Climate Change Science Program Report: Atmospheric Aerosol Properties and Climate Impacts" (2009). We discuss some of the challenges that exist in extending our clear-sky results to all-sky conditions. On the basis of comparisons to suborbital measurements, we present some of the limitations of the MODIS and CALIOP retrievals in the presence of adjacent or underlying clouds. Strategies for meeting these challenges are discussed. We also discuss a methodology for using the multi-sensor aerosol retrievals for aerosol type classification based on advanced clustering techniques. The combination of research results permits conclusions regarding the attribution of aerosol radiative forcing to aerosol type.

AOD↗

Multi-Layer RF Tissue Phantoms for Mimicking a Human Core

This work presents the design recipe, fabrication process and characterization of tissue-simulating materials, configured as a physical model to mimic the electrical and some physical properties of an abdominal cavity. The complete three layer design is called the human core model (HCM). To our knowledge, presented is the first hybrid skin-muscle phantom developed to mimic the electrical properties of the intervening tissue layers of an abdominal cavity within the frequency band of 1 GHz 2 GHz, a band of interest for human body sensing due to its deep detection depth. To complete the model, a liquid blood phantom was also developed and characterized in this frequency band. The phantoms were characterized with respect to complex dielectric constant using the Agilent 85070E dielectric probe kit, and the results compared to the Gabriel model, which is used as the standard for human tissue characterization. Since the tissue impedance is an important parameter for characterizing on-body sensors and near field antenna performance, the impedance of the phantoms were also calculated and presented in the analysis.

Bonds, Quenton↗

Legacy surface change analyses of the 1993 Rock Valley earthquake sequence for direct comparison to planned NA-22 underground conventional high-explosive experiments (Source Physics Experiment 3 (SPE3) - RV/DC Task 1.3 FY22 Final Report)

Recent work under two previous phases of the NNSA NA-22 Source Physics Experiment (SPE) have shown that underground chemical high-explosive experiments can produce detectable surface changes that differ in spatial extent and vertical magnitude depending on the geologic media at the site (Schultz-Fellenz et al., 2018; 2020; Crawford et al., 2021). Neither of these two prior phases of SPE identified natural earthquake-related surface effects in the same region that occurred at a similar depth as the explosive experiments for direct comparison. While earthquakes can also produce surface changes that are detectable using remote sensing data analyses, it is expected that the pattern and spatial extent of surface changes would vary between earthquakes and explosions. However, no direct-observed surface-change signature comparison between earthquakes and explosions has ever been performed. The SPE Phase 3 Rock Valley/Direct Comparison (RV/DC) program presents a unique opportunity to investigate and characterize co-occurrence of both earthquakes and explosions. In this project, we worked to address five tasks in a workflow, as follows: 1. Identify and obtain existing high-resolution legacy satellite and aerial imagery as close in time before and after the 1993 Rock Valley earthquake sequence to temporally constrain the analyses. 2. Transform these pre-earthquake and post-earthquake datasets into digital elevation models (DEMs) using geospatial analysis software packages (e.g., ArcGIS, Agisoft Metashape, and Google Earth Engine). 3. Perform DEM differencing analyses to assess and quantify earthquake-related changes from the 1993 sequence, and develop map products that visualize these analyses. 4. Use the analyses from (3) to: (a) assess spatial distribution and magnitude of surface changes due to the 1993 Rock Valley earthquake sequence, and (b) determine parameters of forthcoming, planned explosion-related surface change data collection from sensors mounted on unmanned aerial vehicles (UAVs) (e.g., spatial extent of collection, design and density of survey control, sensors to deploy, forward speed and line spacing of UAV flight lines, flight altitude). 5. Develop a summary report on the analyses, including how the analyses define parameters and identify focus areas for any future surface change analytical field campaigns related to the explosive experiment. Analyzing these legacy data and identifying whether they can detect any surface changes related to the earthquake sequence facilitates opportunities for direct signature comparison of surface change from explosions at one location, which has never previously been performed. Comparing the surface change signatures from a co-located and depth-equivalent earthquake and an explosion could help to advance remote sensing event discrimination techniques. This report summarizes the work completed toward this ambitious goal.

42 ENGINEERING↗

AstroPix: A pixelated HVCMOS sensor for space-based gamma-ray measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25–700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 μ m. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 ± 3.2% at 59.5 keV and 94 ± 6 μ m depletion in a low-resistivity test silicon substrate.

Astrophysics instrumentation↗

Calibration, Reconstruction, and Rendering of Cylindrical Millimeter-Wave Image Data

Cylindrical millimeter-wave imaging systems and technology have been under development at the Pacific Northwest National Laboratory for many years. This technology has been commercialized, and systems are currently being deployed widely across the United States and internationally. These systems are effective at screening for concealed items of all types, however, new sensor designs, image reconstruction techniques, and image rendering algorithms, could potentially improve performance. At PNNL, a number of specific techniques have been developed recently to improve cylindrical imaging methods including wideband techniques, combining data from full 360 degree scans, polarimetric imaging techniques, calibration methods, and 3-D data visualization techniques. Many of these techniques exploit the three-dimensionality of the cylindrical imaging technique by optimizing the depth resolution of the system and using this information to enhance detection. Other techniques, such as polarimetric methods, exploit scattering physics of the millimeter-wave interaction with concealed targets on the body. In this paper, calibration, reconstruction, and three-dimensional rendering techniques will be described that optimize the depth information in these images and the display of the images to the operator.

concealed-weapon detection↗

Selected micrometeorological and soil data from the Manaus ZF2 K34 eddy covariance tower for the 2015/16 El Niño event

The K34 tower site (2.609 S, 60.209 W, 130 masl), located within the Tropical Silviculture Experimental Station (EEST, also known as ZF2) research station, in an area of undisturbed tropical forest (Araújo et al. 2002). It features long term measurements using micrometeorological, eddy covariance, and soil instrumentation, among others. This dataset covers January 2012 to December 2017, and includes air temperature (TA, ℃) and air relative humidity (RH, %), measured with thermohygrometers (HC2S3, Campbell Scientific, Logan, UT, USA) deployed above the canopy at the top of the tower (at 51.1 m height), and net radiation (NETRAD, W m-2) using an NR-LITE sensor (Kipp & Zonen, Delft, Netherlands), also at the top of the tower (at 35.0 m above the canopy). The soil moisture data included here is from a soil profile located approximately 12 m from the tower, and covers the period between February 2015 and September 2016. Volumetric soil water content (SWC, m3 m-3) measurements used Water Content Reflectometers (CS655 Campbell Scientific, Logan, UT, USA) at six depths: 10 cm, 20 cm, 30 cm, 40 cm, 60 cm, and 100 cm. Data are included in .csv files, and the text file ZF2-K34_Tower_headers.txt provides descriptions of data file headers.

54 ENVIRONMENTAL SCIENCES↗

Deep Controlled Source Electro-Magnetic Sensing: A Cost Effective, Long-Term Tool for Sequestration Monitoring

The proposed system was designed to operate as a permanent, autonomous monitoring and data collection system that can provide much higher temporal data density than can be achieved economically with 3-Dimensional (3D) seismic surveys. It can operate over broad areas for long periods of time providing full 3D data sets on a monthly basis at a very low cost. By borrowing techniques commonly used in marine CSEM, structural information from background seismic surveys can be incorporated into the CSEM modeling to provide high resolution models of CO 2 progression within reservoirs. The system uses borehole-based vertical-electric-dipole sources placed at reservoir depths in the formation. The electric and magnetic fields induced by this source are received on the surface using an array of stations. The project was conducted in three phases. Phase I demonstrated the feasibility of the system to collect static/reference data at the Ketzin CO 2 storage pilot site in Germany. In Phase I, numerical modeling was used to determine the optimal configurations and requirements for sensor sensitivity and data accuracy. Based on the model results, existing hardware and software were modified. The CSEM system was then field tested at the Ketzin site. The data were imaged and the results were compared with independent studies of the reservoir and overburden geo-electrical characteristics. Phase II demonstrated the ability to provide sensitive, cost-effective measurement of changes in reservoir properties and changes in the overlying formations using a second round of measurements at the Ketzin site. A prototype autonomous recording system was developed and tested as a subset of the measurement points. Phase III of the project quantified the advantages (and disadvantages) of the fully autonomous data collection subsystems by comparing them with repeated measurements made with mobile stations. The Phase III also provided an additional time point in measuring post-closure changes in and above the Ketzin CO 2 injection site. Validation of the CSEM field survey results were completed using a method such as other alternative and available field site data.

58 GEOSCIENCES↗

Ultraviolet observations of the transient X-ray sources A0535 + 26 and A0620-00

Observations of A0535+26 (HDE 245770) by the ANS in September 1975 and March 1976 when it was at the X-ray low state are discussed. Also observed were 58 early-type stars lying within 10 deg of HDE 245770; these stars are used to derive a localized extinction curve. On the basis of the depth of the 2200 A interstellar absorption feature observed in the ANS flux distribution of HDE 245770 and the shape of the localized extinction curve, an E(B-V) = 0.72 is derived for HDE 245770. Observations were made of this system during its X-ray flare-up (October 1980) and quiescent (November 1981) states by the IUE. It is noted that the fine error sensor on board the IUE detected an increase in the optical brightness of HDE 245770 during the X-ray outburst. This greatly corroborates the identification of HDE 245770 as the optical counterpart of A0535+26. No significant change in the absorption-line profiles during the X-ray high and low periods is found, indicating that there was no significant increase in the stellar wind density when the X-ray flare-up occurred. The UV continuum level increased by less than 6 percent when it was near peak X-ray luminosity. The UV spectrum of HDE 245770 suggests that it is a B0 V or a B0 III star with its dereddened continuum slope slightly in favor of being a giant.

Wu, C.-C.↗

SAM 2 measurements of the polar stratospheric aerosol, volume 2

The Stratospheric Aerosol Measurement (SAM) 2 sensor aboard Nimbus 7 is providing extinction measurements of Antarctic and Arctic stratospheric aerosols with a vertical resolution of 1 km. Representative examples and weekly averages including corresponding temperature profiles provided by NOAA for the time and place of each SAM 2 measurement (Oct. 1981 - Apr. 1982) are presented. Contours of aerosol extinction as a function of altitude and longitude or time are plotted, and aerosol optical depths are calculated for each week. Typical values of aerosol extinction at 1.0 micron in the main lower stratospheric aerosol layer for this time period are 2 to 4 times 10 to the -4 power/km. for the Antarctic region and 0.5 to 1 times 10 to the -3 power/km. for the Arctic region. Stratospheric optical depths are about 0.001 to 0.004 for the Antarctic region and 0.003 to 0.004 at the beginning to about 0.006 at the end of the time period for the Arctic region. Polar stratospheric clouds (PSC's) were observed during the Arctic winter, as expected. This report provides, in a ready-to-use format, a representative sample of the seventh semester of data to be used in atmospheric and climatic studies.

Mccormick, M. P.↗

SAM 2 measurements of the polar stratospheric aerosol, volume 8

The Stratospheric Aerosol Measurement (SAM) 2 sensor aboard Nimbus 7 is providing extinction measurements of Antarctic and Arctic stratospheric aerosols with a vertical resolution of 1 km. Representative examples and weekly averages including corresponding temperature profiles provided by NOAA for the time and place of each SAM 2 measurement (Apr. 1982 - Oct. 1982) are presented. Contours of aerosol extinction as a function of altitude and longitude or time are plotted, and aerosol optical depths are calculated for each week. Typical values of aerosol extinction at 1.0 microns in the main stratospheric aerosol layer are approximately 4 to 6 times .0001/km at the beginning to 1 to 2 times .001/km at the end of the time period for the Antarctic region and approximately 1 to 3 times .001/km for the Arctic region throughout the time period. Stratospheric optical depths are about 0.002 to 0.009 for the Antarctic region and about 0.007 at the beginning to 0.024 at the end of the time period for the Arctic region. Polar stratospheric clouds were observed during the Antarctic winter, as expected. This report provides, in a ready-to-use format, a representative sample of the eighth 6 months of data to be used in atmospheric and climatic studies.

Mccormick, M. P.↗

Atmospheric optical depth effects on angular anisotropy of plant canopy reflectance

The effects of varying atmospheric aerosol optical depth on the bidirectional reflectance distribution of vegetation canopies is investigated. The reflectance distributions of two pasture grass canopies and one soya bean canopy under different sky irradiance distributions were measured, and the data were analyzed in the visible and IR spectral bands. It is observed that, for the pasture grass canopies, the change in reflectance is due to the percentage of shadowed area viewed by the sensor, and for the soya bean, the specular reflection effect and increased diffuse irradiance penetration into the canopy cause reflectance changes. It is detected that the reflectivity for the soya bean canopy on a hazy day is lower than on a clear day; however, the opposite change is observed for the pasture grass. It is also detected that the normalized difference vegetation index values differ under clear and hazy conditions for the same vegetation canopy conditions.

Deering, Donald W.↗

Expansion-based passive ranging

A new technique of passive ranging which is based on utilizing the image-plane expansion experienced by every object as its distance from the sensor decreases is described. This technique belongs in the feature/object-based family. The motion and shape of a small window, assumed to be fully contained inside the boundaries of some object, is approximated by an affine transformation. The parameters of the transformation matrix are derived by initially comparing successive images, and progressively increasing the image time separation so as to achieve much larger triangulation baseline than currently possible. Depth is directly derived from the expansion part of the transformation. To a first approximation, image-plane expansion is independent of image-plane location with respect to the focus of expansion (FOE) and of platform maneuvers. Thus, an expansion-based method has the potential of providing a reliable range in the difficult image area around the FOE. In areas far from the FOE the shift parameters of the affine transformation can provide more accurate depth information than the expansion alone, and can thus be used similarly to the way they were used in conjunction with the Inertial Navigation Unit (INU) and Kalman filtering. However, the performance of a shift-based algorithm, when the shifts are derived from the affine transformation, would be much improved compared to current algorithms because the shifts - as well as the other parameters - can be obtained between widely separated images. Thus, the main advantage of this new approach is that, allowing the tracked window to expand and rotate, in addition to moving laterally, enables one to correlate images over a very long time span which, in turn, translates into a large spatial baseline - resulting in a proportionately higher depth accuracy.

Barniv, Yair↗

Regional Characteristics of the Relationship Between Columnar AOD and Surface PM2.5: Application of Lidar Aerosol Extinction Profiles over Baltimore-Washington Corridor During DISCOVER-AQ

The first field campaign of DISCOVER-AQ (Deriving Information on Surface conditions from COlumn and VERtically resolved observations relevant to Air Quality) took place in July 2011 over Baltimore-Washington Corridor (BWC). A suite of airborne remote sensing and in-situ sensors was deployed along with ground networks for mapping vertical and horizontal distribution of aerosols. Previous researches were based on a single lidar station because of the lack of regional coverage. This study uses the unique airborne HSRL (High Spectral Resolution Lidar) data to baseline PM2.5 (particulate matter of aerodynamic diameter less than 2.5 μm) estimates and applies to regional air quality with satellite AOD (Aerosol Optical Depth) retrievals over BWC (∼6500 sq. km). The linear approximation takes into account aerosols aloft above AML (Aerosol Mixing Layer) by normalizing AOD with haze layer height (i.e., AOD/HLH). The estimated PM2.5 mass concentrations by HSRL AOD/HLH are shown within 2 RMSE (Root Mean Square Error ∼9.6 μg/cu. m) with correlation ∼0.88 with the observed over BWC. Similar statistics are shown when applying HLH data from a single location over the distance of 100 km. In other words, a single lidar is feasible to cover the range of 100 km with expected uncertainties. The employment of MPLNET-AERONET (MicroPulse Lidar NETwork - AErosol RObotic NETwork) measurements at NASA GSFC produces similar statistics of PM2.5 estimates as those derived by HSRL. The synergy of active and passive remote sensing aerosol measurements provides the foundation for satellite application of air quality on a daily basis. For the optimal range of 10 km, the MODIS-estimated PM2.5 values are found satisfactory at 27 (out of 36) sunphotometer locations with mean RMSE of 1.6-3.3 μg/cu. m relative to PM2.5 estimated by sunphotometers. The remaining 6 of 8 marginal sites are found in the coastal zone, for which associated large RMSE values ∼4.5-7.8 μg/cu. m are most likely due to overestimated AOD because of water-contaminated pixels.

DISCOVER-AQ↗

Design of an unmanned Martian polar exploration system

The design of an unmanned Martian polar exploration system is presented. The system elements include subsystems for transportation of material from earth to Mars, study of the Martian north pole, power generation, and communications. Early next century, three Atlas 2AS launch vehicles will be used to insert three Earth-Mars transfer vehicles, or buses, into a low-energy transfer orbit. Capture at Mars will be accomplished by aerobraking into a circular orbit. Each bus contains four landers and a communications satellite. Six of the twelve total landers will be deployed at 60 deg intervals along 80 deg N, and the remaining six landers at 5 deg intervals along 30 deg E from 65 deg N to 90 deg N by a combination of retrorockets and parachutes. The three communications satellites will be deployed at altitudes of 500 km in circular polar orbits that are 120 deg out of phase. These placements maximize the polar coverage of the science and communications subsystems. Each lander contains scientific equipment, two microrovers, power supplies, communications equipment, and a science computer. The lander scientific equipment includes a microweather station, seismometer, thermal probe, x-ray spectrometer, camera, and sounding rockets. One rover, designed for short-range (less than 2 km) excursions from the lander, includes a mass spectrometer for mineral analysis, an auger/borescope system for depth profiling, a deployable thermal probe, and charge coupled device cameras for terrain visualization/navigation. The second rover, designed for longer-range (2-5 km) excursions from the lander, includes radar sounding/mapping equipment, a seismometer, and laser ranging devices. Power for all subsystems is supplied by a combination of solar cells, Ni-H batteries, and radioisotope thermoelectric generators. Communications are sequenced from rovers, sounding rockets, and remote sensors to the lander, then to the satellites, through the Deep Space Network to and from earth.

Baldwin, Curt↗

Gyro Evaluation for the Mission to Jupiter

As an important component in NASA's New Frontiers Program, the Jupiter Polar Orbiter (Juno) mission is designed to investigate in-depth physical properties of Jupiter. It will include the giant planet's ice-rock core and atmospheric studies as well as exploration of its polar magnetosphere. It will also provide the opportunity to understand the origin of the Jovian magnetic field. Due to severe radiation environment of the Jovian system, this mission inherently presents a significant technical challenge to Attitude Control System (ACS) design since the ACS sensors must survive and function properly to reliably maneuver the spacecraft throughout the mission. Different gyro technologies and their critical performance characteristics are discussed, compared and evaluated to facilitate a choice of appropriate gyro-based inertial measurement unit to operate in a harsh Jovian environment to assure mission success.

physical properties↗

Superconducting Effects in Optimization of Magnetic Penetration Thermometers for X-ray Microcalorimeters

We have made high resolution x-ray microcalorimeters using superconducting MoAu bilayers and Nb meander coils. The temperature sensor is a Magnetic Penetration Thermometer (MPT). Operation is similar to metallic magnetic calorimeters, but instead of the magnetic susceptibility of a paramagnetic alloy, we use the diamagnetic response of the superconducting MoAu to sense temperature changes in an x-ray absorber. Flux-temperature responsivtty can be large for small sensor heat capacity, with enough dynamic range for applications. We find models of observed flux-temperature curves require several effects to explain flux penetration or expulsion in the microscopic devices. The superconductor is non-local, with large coherence length and weak pinning of flux. At lowest temperatures, behavior is dominated by screening currents that vary as a result of the temperature dependence of the magnetic penetration depth, modified by the effect of the nonuniformity of the applied field occurring on a scale comparable to the coherence length. In the temperature regime where responslvity is greatest, spadal variations in the order parameter become important: both local variations as flux enters/leaves the film and an intermediate state is formed, and globally as changing stability of the electrical circuit creates a Meissner transition and flux is expelled/penetrates to minimize free energy.

Stevenson, Thomas R.↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗