Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Objectives and design of the Echo 6 electron beam experiment - Large ionospheric perturbations and energetic particle patterns

The data from the March 30, 1983 launching of Echo 6 are presented. Echo 6 contained duplex accelerators and a system of four throw away detectors to detect and analyze conjugate electron echoes. The model used to calculate the proper trajectory of the rocket and the reason for not detecting echoes are discussed. The components of the plasma diagnostic package which was used to study the electron beam interactions with the ionospheric plasma, and the functions of the two controllable electron guns and the two sets of orthogonal electric probes are described. The signal-mode potentials between each probe and the plasma diagnostic payload are investigated. The signals produced by the gun pulses are analyzed and the interpretation of the electric field probe response is examined.

Winckler, J. R.↗

Icing Research Tunnel

The Icing Research Tunnel in Building 11 at the NASA Glenn Research Center is committed to researching the effects of in flight icing on aircraft and testing ways to stop the formation of hazardous icing conditions on planes. During this summer, I worked here with Richard DelRosa, the lead engineer for this area. address one of the major concerns of aviation: icing conditions. During the war, many planes crashed (especially supply planes going over the.Himalayas) because ice built up in their wings and clogged the engines. To this day, it remains the largest ice tunnel in the world, with a test section that measures 6 feet high, 9 feet long, and 20 feet wide. It can simulate airspeeds from 50 to 300 miles per hour at temperatures as low as -50 Fahrenheit. Using these capabilities, IRT can simulate actual conditions at high altitudes. The first thing I did was creating a cross reference in Microsoft Excel. It lists commands for the DPU units that control the pressure and temperature variations in the tunnel, as well as the type of command (keyboard, multiplier, divide, etc). The cross reference also contains the algorithm for every command, and which page it is listed in on the control sheet (visual Auto-CAD graphs, which I helped to make). I actually spent most of the time on the computer using Auto-CAD. I drew a diagram of the entire icing tunnel and then drew diagrams of its various parts. Between my mentor and me, we have drawings of every part of it, from the spray bars to the thermocouples, power cabinets, input-output connectors for power systems, and layouts of various other machines. I was also responsible for drawing schematics for the Escort system (which controls the spray bars), the power system, DPUs, and other electrical systems. In my spare time, I am attempting to build and program the "toddler". Toddler is a walking robot that I have to program in PBASIC language. When complete, it should be able to walk on level terrain while avoiding obstacles in real-time. It features an infrared detector that can keep it from falling over edges, as well as follow or avoid a light source. The toddler is giving me a much better understanding of the basics of electronic circuitry and computer programming.

Chennault, Jonathan↗

Optical Communications Link to Airborne Transceiver

An optical link from Earth to an aircraft demonstrates the ability to establish a link from a ground platform to a transceiver moving overhead. An airplane has a challenging disturbance environment including airframe vibrations and occasional abrupt changes in attitude during flight. These disturbances make it difficult to maintain pointing lock in an optical transceiver in an airplane. Acquisition can also be challenging. In the case of the aircraft link, the ground station initially has no precise knowledge of the aircraft s location. An airborne pointing system has been designed, built, and demonstrated using direct-drive brushless DC motors for passive isolation of pointing disturbances and for high-bandwidth control feedback. The airborne transceiver uses a GPS-INS system to determine the aircraft s position and attitude, and to then illuminate the ground station initially for acquisition. The ground transceiver participates in link-pointing acquisition by first using a wide-field camera to detect initial illumination from the airborne beacon, and to perform coarse pointing. It then transfers control to a high-precision pointing detector. Using this scheme, live video was successfully streamed from the ground to the aircraft at 270 Mb/s while simultaneously downlinking a 50 kb/s data stream from the aircraft to the ground.

Regehr, Martin W.↗

Poster — Thur Eve — 02: Measurement of CT radiation profile width using Fuji CR imaging plate raw data

Measuring the CT collimation width and assessing the shape of the overall profile is a relatively straightforward quality control (QC) measure that impacts both image quality and patient dose, and is often required at acceptance and routine testing. Most CT facilities have access to computed radiography (CR) systems, so performing CT collimation profile assessments using CR plates requires no additional equipment. Previous studies have shown how to effectively use CR plates to measure the radiation profile width. However, a major limitation of the previous work is that the full dynamic range of CR detector plates are not used, since the CR processing technology reduces the dynamic range of the DICOM output to 2{sup 10}, requiring the sensitivity and latitude settings of CR reader to be adjusted to prevent clipping of the CT profile data. Such adjustments to CR readers unnecessarily complicate the QC procedure. These clipping artefacts hinder the ability to accurately assess CT collimation width because the full-width at half maximum value of the penumbras are not properly determined if the maximum dose of the profile is not available. Furthermore, any inconsistencies in the radiation profile shape are lost if the profile plateau is clipped off. In this work we developed an opensource Matlab script for straightforward CT profile width measurements using raw CR data that also allows assessment of the profile shape without clipping, and applied this approach during CT QC.

60 APPLIED LIFE SCIENCES↗

D0 Silicon Detector Moisture Injection

The system is designed to increase water content in dry air used to purge DO silicon detector. Moisture will not be added to fiber tracker purge. Currently, the air is dried to -85 deg. C (-120 deg. F). The goal is to increase Dew point of the air to about -40 C to -20 C range. This is done by redirecting a portion of dry air (about 10%) through a bubbler, and then return it to main stream. Air is taken upstream of PRV-6231-I pressure regulator (90 psi) and going to the bubbler (BU-6404-I) through the flow regulator, permitting controlled moisture addition. Water separator (FI-6411-I) and auto drain (MV-6412-I) prevent water break-trough in case of bubbler's overflowing. Moist air (saturated with water) is returned to main flow of purge air downstream of PRV-6231-I (55 psi). Water is taken from DO LCW system. Initial pressure of 110 psi is reduced to 60 psi (PRV-6421-I); expected fill rate is 1 Umin. with 55 psi in the bubbler.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-313: Clinical Results of a New Customer Acceptance Test for Elekta VMAT

Purpose: To report the results of a customer acceptance test (CAT) for VMAT treatments for two matched Elekta linear accelerators. Methods: The CAT tests were performed on two clinically matched Elekta linear accelerators equipped with a 160-leaf MLC. Functional tests included performance checks of the control system during dynamic movements of the diaphragms, MLC, and gantry. Dosimetric tests included MLC picket fence tests at static and variable dose rates and a diaphragm alignment test, all performed using the on-board EPID. Additionally, beam symmetry during arc delivery was measured at the four cardinal angles for high and low dose rate modes using a 2D detector array. Results of the dosimetric tests were analyzed using the VMAT CAT analysis tool. Results: Linear accelerator 1 (LN1) met all stated CAT tolerances. Linear accelerator 2 (LN2) passed the geometric, beam symmetry, and MLC position error tests but failed the relative dose average test for the diaphragm abutment and all three picket fence fields. Though peak doses in the abutment regions were consistent, the average dose was below the stated tolerance corresponding to a leaf junction that was too narrow. Despite this, no significant differences in patient specific VMAT quality assurance measured were observed between the accelerators and both passed monthly MLC quality assurance performed with the Hancock test. Conclusion: Results from the CAT showed LN2 with relative dose averages in the abutment regions of the diaphragm and MLC tests outside the tolerances resulting from differences in leaf gap distances. Tolerances of the dose average tests from the CAT may be small enough to detect MLC errors which do not significantly affect patient QA or the routine MLC tests.

60 APPLIED LIFE SCIENCES↗

NASA Tech Briefs, March 2007

Topics include: Advanced Systems for Monitoring Underwater Sounds; Wireless Data-Acquisition System for Testing Rocket Engines; Processing Raw HST Data With Up-to-Date Calibration Data; Mobile Collection and Automated Interpretation of EEG Data; System for Secure Integration of Aviation Data; Servomotor and Controller Having Large Dynamic Range; Digital Multicasting of Multiple Audio Streams; Translator for Optimizing Fluid-Handling Components; AIRSAR Web-Based Data Processing; Pattern Matcher for Trees Constructed From Lists; Reducing a Knowledge-Base Search Space When Data Are Missing; Ground-Based Correction of Remote-Sensing Spectral Imagery; State-Chart Autocoder; Pointing History Engine for the Spitzer Space Telescope; Low-Friction, High-Stiffness Joint for Uniaxial Load Cell; Magnet-Based System for Docking of Miniature Spacecraft; Electromechanically Actuated Valve for Controlling Flow Rate; Plumbing Fixture for a Microfluidic Cartridge; Camera Mount for a Head-Up Display; Core-Cutoff Tool; Recirculation of Laser Power in an Atomic Fountain; Simplified Generation of High-Angular-Momentum Light Beams; Imaging Spectrometer on a Chip; Interferometric Quantum-Nondemolition Single-Photon Detectors; Ring-Down Spectroscopy for Characterizing a CW Raman Laser; Complex Type-II Interband Cascade MQW Photodetectors; Single-Point Access to Data Distributed on Many Processors; Estimating Dust and Water Ice Content of the Martian Atmosphere From THEMIS Data; Computing a Stability Spectrum by Use of the HHT; Theoretical Studies of Routes to Synthesis of Tetrahedral N4; Estimation Filter for Alignment of the Spitzer Space Telescope; Antenna for Measuring Electric Fields Within the Inner Heliosphere; Improved High-Voltage Gas Isolator for Ion Thruster; and Hybrid Mobile Communication Networks for Planetary Exploration.

Source record↗

Status Update: Uranyl Nitrate Calibration Loop Equipment (UNCLE) at ORNL

The successful completion of a field trial of safeguards monitoring equipment at a natural uranium conversion plant (NUCP) demonstrated the need for a facility in which to perform full-scale equipment testing under controlled conditions prior to field deployment of safeguards systems at additional plants. Oak Ridge National Laboratory has developed a Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility to simulate the full-scale operating conditions for a purified uranium-bearing aqueous stream exiting the solvent extraction process conducted in an NUCP. In addition to calibrating instruments such as the neutron detector developed at Los Alamos National Laboratory, UNCLE will be used to test other in-line instruments (mass and volumetric flowmeters, spectrophotometers, etc.). UNCLE will be able to test commercially available equipment, such as the Endress+Hauser Promass 83F Coriolis meter that was used in the field test and other equipment that is presently under development. UNCLE is designed to accommodate different pipe sizes, flow rates, solution concentrations, and other variables of interest. Construction is expected to be completed by the end of September 2008 with initial testing beginning later that year. The design and current status of UNCLE will be presented, along with the capabilities of the facility and the proposed test plans.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte Carlo N-Particle Transport Performance of Predicting Digital Radiographic IQI Inspection

The identification of porosity, geometric noncompliance, and other defect types are critical to the qualification of materials and components. X-ray radiographic nondestructive testing is a common industrial inspection method for process quality control and component qualification and certification. Digital radiography provides a quick and efficient alternative when compared to traditional film-based inspection. The quality of radiographic inspection is dependent on equipment specifications, such as the source spot size and detector pixel size, and the specific parameters selected for use for the radiographic technique. To evaluate if an x-ray system and technique is sufficient for a given requirement, a radiographic image quality indicator (IQI) can be used. Radiographic IQIs in hard to machine materials or hard to manufacture defects can be time consuming and expensive to manufacture. This study was conducted to evaluate current Savannah River National Laboratory (SRNL) x-ray imaging systems with a custom tantalum IQI and using Monte Carlo simulations to predict the performance of future systems. The tantalum IQI was tested using a Siefert Isovolt 420 keV x-ray tube with a Perkin Elmer XRD 1611 flat panel with 100-micron pixels. Using the Monte Carlo N-Particle transport software, the radiographic tally was used to simulate the photon flux through an identical tantalum IQI. These simulations provided a benchmark as to the best theoretical identification on a given system using our tantalum IQI. The simulations were refined to match SRNL’s current systems’ noise levels, leading to confidence in their ability to predict the performance of other systems that may be purchased and deployed in the future at the Savannah River Site. Future studies will be conducted to prove this research can be extended to artificially evaluate the ability for systems to identify critical defect sizes through x-ray radiographic inspection, drastically reducing the cost and time burdens of producing high-fidelity radiographic test articles.

digital X-ray radiography↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Final Review of the Performance of the CDF Run II Data Acquisition System

The CDF Collider Detector at Fermilab ceased data collection on September 30, 2011 after over twenty-five years of operation. We review the performance of the CDF Run II data acquisition systems over the last ten of these years while recording nearly 10 inverse femtobarns of proton-antiproton collisions with a high degree of efficiency - exceeding 83%. Technology choices in the online control and configuration systems and front-end embedded processing have impacted the efficiency and quality of the data accumulated by CDF, and have had to perform over a large range of instantaneous luminosity values and trigger rates. We identify significant sources of problems and successes. In particular, we present our experience computing and acquiring data in a radiation environment, and attempt to correlate system technical faults with radiation dose rate and technology choices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative Velocity Field Measurements in Reduced-Gravity Combustion Science and Fluid Physics Experiments

Systems have been developed and demonstrated for performing quantitative velocity measurements in reduced gravity combustion science and fluid physics investigations. The unique constraints and operational environments inherent to reduced-gravity experimental facilities pose special challenges to the development of hardware and software systems. Both point and planar velocimetric capabilities are described, with particular attention being given to the development of systems to support the International Space Station laboratory. Emphasis has been placed on optical methods, primarily arising from the sensitivity of the phenomena of interest to intrusive probes. Limitations on available power, volume, data storage, and attendant expertise have motivated the use of solid-state sources and detectors, as well as efficient analysis capabilities emphasizing interactive data display and parameter control.

Greenberg, Paul S.↗

Post-CDR Thermal Design and Analysis of the Starburst Instrument

The StarBurst Multimessenger Pioneer is a small satellite serving as a wide-field gamma-ray observatory designed to detect the initial emissions of short gamma ray bursts, electromagnetic indicators of neutron star mergers. This paper will detail the thermal design and analysis of the instrument, which includes both the control electronics and crystal detector units (CDUs). The CDUs are a critical component essential to mission success and have the narrowest temperature range, however the CDU thermal model is low fidelity at the time of Critical Design Review (CDR) before a final CDU design is completed. Therefore, a more detailed CDU model is created for post-CDR analysis to update the passive Thermal Control System (TCS) design and efficiently maintain the operational and survival temperature limits with minimal heater power. Including the additional detail is necessary to determine the final Multilayer Insulation (MLI) design, including material selection and coverage, coating selection, and required heater power.

thermal design↗

Post-CDR Thermal Design and Analysis of the Starburst Instrument

The StarBurst Multimessenger Pioneer is a small satellite serving as a wide-field gamma-ray observatory designed to detect the initial emissions of short gamma ray bursts, electromagnetic indicators of neutron star mergers. This paper will detail the thermal design and analysis of the instrument, which includes both the control electronics and crystal detector units (CDUs). The CDUs are a critical component essential to mission success and have the narrowest temperature range, however the CDU thermal model is low fidelity at the time of Critical Design Review (CDR) before a final CDU design is completed. Therefore, a more detailed CDU model is created for post-CDR analysis to update the passive Thermal Control System (TCS) design and efficiently maintain the operational and survival temperature limits with minimal heater power. Including the additional detail is necessary to determine the final Multilayer Insulation (MLI) design, including material selection and coverage, coating selection, and required heater power.

thermal design↗

Comparing Control Performance Between Simulation and Experiment using the Microreactor Automated Control System Testbed

In the advanced reactor domain, a flexible and scalable software/hardware infrastructure is crucial for integrating and validating various control technologies. This study used the Microreactor Automated Control System (MACS) hardware platform as a testbed. MACS was originally designed to mirror Idaho National Laboratory (INL)'s Microreactor Applications Research Validation and Evaluation (MARVEL), a 85-kW thermal fission microreactor. It features control drums for simulated reactivity control; lights that function as a surrogate reactor core, with the brightness being proportional to the reactor power; and light sensors that emulate neutron detectors. To transform MACS into a physical twin of MARVEL for evaluating control methods, the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software was employed. This software integrated the hardware with two models of the MARVEL core, based on Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The study aimed to demonstrate the gap between control theory and actual practice—a gap that often necessitates empirical adjustments such as control gain retuning, filters, time discretization, and integrator anti-windup measures. Controllers were developed based on increasingly complex simulations without hardware, starting from the base MARVEL model and then introducing actuator saturation constraints and sensor noise. The final control strategy was then tested using MACS, and a comparative performance analysis was conducted.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Intelligent experiments through real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and future EIC detectors (Phase-I)

With an ever increasing demand for high precision data from modern detectors for discovery science and precision measurements, all major high energy nuclear and particle experiments, current and future, are facing the challenge on how to deal with the large volume of raw data generated from sophisticated state-of-the-art detectors in high rate collisions. These goals need to be balanced with available hardware and cost limits on DAQ (Data AcQuisition system) bandwidth and offline computing resources to capture, store and process the signal events. Two prototypical examples are the upcoming sPHENIX experiment, the DOE next generation heavy ion physics experiment at the Relativistic Heavy Ion Collider at BNL, and the future EIC experiments that are planned to be online circa 2030.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CMS ECAL database services for detector control and monitoring

In this paper we give a description of the database services for the control and monitoring of the electromagnetic calorimeter of the CMS experiment at LHC. After a general description of the software infrastructure, we present the organization of the tables in the database, that has been designed in order to simplify the development of software interfaces. This feature is achieved including in the database the description of each relevant table. We also give some estimation about the final size and performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗