Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

Goetz, Callie↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

Abstract—The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The very forward CASTOR calorimeter of the CMS experiment

The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located very close to the LHC beam line, at a radial distance of about 1 cm from the beam pipe, and at 14.4 m from the CMS interaction point, covering the pseudorapidity range of $-$6.6 $\lt\eta\lt$ $-$5.2. It was designed to withstand high ambient radiation and strong magnetic fields. The performance of the detector in measurements of forward energy density, jets, and processes characterized by rapidity gaps, is reviewed using data collected in proton and nuclear collisions at the LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Muon Neutrino Charged-Current Mesonless Cross Section Measurement in the NOvA Near Detector

NOvA is a long-baseline accelerator neutrino experiment at Fermilab whose physics goals include precision neutrino oscillation as well as cross-section measurements. We present the status of the measurement of a muon neutrino charged-current cross section with zero mesons in the final state at the NOvA near detector. This measurement is being made with respect to the kinematics of the final state muon. The chosen interaction channel is especially sensitive to quasielastic and meson exchange current interactions and aims to provide experimental constraints for the development of models of neutrino interactions. It will also provide a handle for constraining cross section systematic uncertainties in oscillation analyses in current and future experiments. For particle identification, we use a convolutional neural network (CNN) trained on individual particles simulated in the NOvA near detector that allows us to select the desired signal while reducing the potential bias from neutrino interaction modeling. Charged pion background constraining is further improved via Michel electron tagging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the Muon Neutrino Charged-Current Zero Mesons Cross Section at the NOvA Near Detector

NOvA is a long-baseline accelerator neutrino experiment at Fermilab whose physics goals include precision neutrino oscillation as well as cross-section measurements. We present the status of the measurement of a muon neutrino charged-current cross section with zero mesons in the final state at the NOvA near detector. This measurement is being made with respect to the kinematics of the final state muon. The chosen interaction channel is especially sensitive to quasielastic and meson exchange current interactions and aims to provide experimental constraints for the development of models of neutrino interactions. It will also provide a handle for constraining cross section systematic uncertainties in oscillation analyses in current and future experiments. For particle identification, we use a convolutional neural network (CNN) trained on individual particles simulated in the NOvA near detector that allows us to select the desired signal while reducing the potential bias from neutrino interaction modeling. Charged pion background constraining is further improved via Michel electron tagging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Direction-Sensitive Detector for Electron Antineutrinos

A modular design is proposed for an electron antineutrino detector based on boron-doped liquid scintillator. Tests have been carried out on small detector systems using neutrons to simulate the antineutrino detection signature. Results from these tests are reported, and the possibility of using a larger system of similar design to detect reactor antineutrinos is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-06: Development of a Formalism for Practical Dose Measurements in Brachytherapy in the German Standard DIN 6803

Purpose: In the steep dose gradients in the vicinity of a radiation source and due to the properties of the changing photon spectra, dose measurements in Brachytherapy usually have large uncertainties. Working group DIN 6803-3 is presently discussing recommendations for practical brachytherapy dosimetry incorporating recent theoretical developments in the description of brachytherapy radiation fields as well as new detectors and phantom materials. The goal is to prepare methods and instruments to verify dose calculation algorithms and for clinical dose verification with reduced uncertainties. Methods: After analysis of the distance dependent spectral changes of the radiation field surrounding brachytherapy sources, the energy dependent response of typical brachytherapy detectors was examined with Monte Carlo simulations. A dosimetric formalism was developed allowing the correction of their energy dependence as function of source distance for a Co-60 calibrated detector. Water equivalent phantom materials were examined with Monte Carlo calculations for their influence on brachytherapy photon spectra and for their water equivalence in terms of generating equivalent distributions of photon spectra and absorbed dose to water. Results: The energy dependence of a detector in the vicinity of a brachytherapy source can be described by defining an energy correction factor kQ for brachytherapy in the same manner as in existing dosimetry protocols which incorporates volume averaging and radiation field distortion by the detector. Solid phantom materials were identified which allow precise positioning of a detector together with small correctable deviations from absorbed dose to water. Recommendations for the selection of detectors and phantom materials are being developed for different measurements in brachytherapy. Conclusion: The introduction of kQ for brachytherapy sources may allow more systematic and comparable dose measurements. In principle, the corrections can be verified or even determined by measurement in a water phantom and comparison with dose distributions calculated using the TG43 dosimetry formalism. Project is supported by DIN Deutsches Institut fuer Normung.

60 APPLIED LIFE SCIENCES↗

Computing waveforms for spinning compact binaries in quasi-eccentric orbits

Several scenarios have been proposed in which the orbits of binary black holes enter the band of a gravitational wave detector with significant eccentricity. To avoid missing these signals or biasing parameter estimation it is important that we consider waveform models that account for eccentricity. The ingredients needed to compute post-Newtonian (PN) waveforms produced by spinning black holes inspiralling on quasi-eccentric orbits have been available for almost two decades at 2 PN order, and this work has recently been extended to 2.5 PN order. However, the computational cost of directly implementing these waveforms is high, requiring many steps per orbit to evolve the system of coupled differential equations. Here we employ the standard techniques of a separation of time scales and a generalized Keplerian parameterization of the orbits to produce efficient waveforms describing spinning black hole binaries with arbitrary masses and spins on quasi-eccentric orbits to 1.5 PN order. We separate the fast orbital time scale from the slow spin-orbit precession time scale by solving for the orbital motion in a noninterial frame of reference that follows the orbital precession. We outline a scheme for extending our approach to higher post-Newtonian order.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NaI (Tl) calorimeter calibration and simulation for Coulomb sum rule experiment in Hall-A at Jefferson Lab

A precision measurment of inclusive electron scattering cross sections is carried out at Jefferson Lab in the quasi-elastic region for 4 He, 12 C, 56 Fe and 208 Pb targets. The longitudinal (R L ) and transverse (R T ) response functions of the nucleon need to be extracted precisely in the momentum transfer range 0.55 GeV/c ≤ |q| ≤ 1.0 GeV/c. To achieve the above goal, a NaI (Tl) calorimeter is used to distinguish good electrons from background, including pions and low energy electrons rescattered from the walls of the spectrometer magnets. Due to a large set of kinematics and changes in HV settings, a number of calibrations are performed for the NaI (Tl) detector. Corrections for a few blocks of NaI (Tl) with bad or no signal are applied. The resolution of the NaI (Tl) detector after calibration reached ɤE/√E ≈ 3% at E = 1 GeV. The performance of the NaI (Tl) detector is compared with a simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evolution of DUNE’s Production System

The DUNE experiment will start running in 2029 and record 30 PB/year of raw waveforms from Liquid Argon TPCs and photon detectors. The size of individual readouts can range from 100 MB to a typical 8 GB full readout of the detector, and even 100 TB for extended readouts from supernova candidates. These data then need to be cataloged, stored and distributed for processing worldwide. This massive amount of data and a heterogeneous computing environment necessitates a powerful and robust distributed computing infrastructure. In the process of building up that infrastructure, DUNE’s production system has recently undergone an overhaul, in which it has integrated 1) a new workflow management system (justIN) 2) a new data catalog (MetaCat) and 3) a state-of-the-art data management system (Rucio). Simulations of DUNE’s Far Detector and its prototypes ProtoDUNE Horizontal Drift (ProtoDUNE-HD) and ProtoDUNE Vertical Drift (ProtoDUNE-VD), as well as data from ProtoDUNE-HD serve as the first tests of this infrastructure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modelling Z→TT processes in ATLAS with T-embedded Z →μμ data

We describe the concept, technical realisation and validation of a largely data-driven method to model events with Z→ττ decays. In Z→μμ events selected from proton-proton collision data recorded at √s=8 TeV with the ATLAS experiment at the LHC in 2012, the Z decay muons are replaced by τ leptons from simulated Z →ττ decays at the level of reconstructed tracks and calorimeter cells. The τ lepton kinematics are derived from the kinematics of the original muons. Thus, only the well-understood decays of the Z boson and τ leptons as well as the detector response to the τ decay products are obtained from simulation. All other aspects of the event, such as the Z boson and jet kinematics as well as effects from multiple interactions, are given by the actual data. This so-called τ-embedding method is particularly relevant for Higgs boson searches and analyses in ττ final states, where Z→ττ decays constitute a large irreducible background that cannot be obtained directly from data control samples. In this paper, we discuss the relevant concepts based on the implementation used in the ATLAS Standard Model H→ττ analysis of the full datataset recorded during 2011 and 2012.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SOLPOL: A Solar Polarimeter for Hard X-Rays and Gamma-Rays

Th goal of this project was to continue the development of a hard X-ray polarimeter for studying solar flares. In earlier work (funded by a previous SR&T grant), we had already achieved several goals, including the following: 1) development of a means of producing a polarized radiation source in the lab that could be used for prototype development; 2) demonstrated the basic Compton scatter polarimeter concept using a simple laboratory setup; 3) used the laboratory results to verify our Monte Carlo simulations; and 4) investigated various detector technologies that could be incorporated into the polarimeter design. For the current one-year program, we wanted to fabricate and test a laboratory science model based on our SOLPOL (Solar Polarimeter) design. The long-term goal of this effort is to develop and test a prototype design that could be used to study flare emissions from either a balloon- or space-borne platform. The current program has achieved its goal of fabricating and testing a science model of the SOLPOL design, although additional testing of the design (and detailed comparison with Monte Carlo simulations) is still desired. This one-year program was extended by six months (no-cost extension) to cover the summer of 1999, when undergraduate student support was available to complete some of the laboratory testing.

McConnell, Michael L.↗

Scaling studies for deep learning in Liquid Argon Time Projection Chamber event classification

Measurements in Liquid Argon Time Projection Chamber neutrino detectors feature large, high fidelity event images. Deep learning techniques have been extremely successful in classification tasks of photographs, but their application to these event images is challenging, due to the large size of the events, more two orders of magnitude larger than images found in classical chal- lenges like MNIST or ImageNet. This leads to extremely long training cycles, which slow down the exploration of new network architectures and hyperpa- rameter scans to improve the classification performance. We present studies of scaling an LArTPC classification problem on multiple architectures, spanning multiple nodes. The studies are carried out in simulated events in the MicroBooNE detector.

Strube, Jan F.↗

Performance of the Versatile Array of Neutron Detectors at Low Energy (VANDLE)

The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new, highly efficient plastic-scintillator array constructed for decay and transfer reaction experimental setups that require neutron detection. The versatile and modular design allows for customizable experimental setups including beta-delayed neutron spectroscopy and (d,n) transfer reactions in normal and inverse kinematics. The neutron energy and prompt-photon discrimination is determined through the time of flight technique. Fully digital data acquisition electronics and integrated triggering logic enables some VANDLE modules to achieve an intrinsic efficiency over 70% for 300-keV neutrons, measured through two different methods. A custom Geant4 simulation models aspects of the detector array and the experimental setups to determine efficiency and detector response. Lastly, a low detection threshold, due to the trigger logic and digitizing data acquisition, allowed us to measure the light-yield response curve from elastically scattered carbon nuclei inside the scintillating plastic from incident neutrons with kinetic energies below 2 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytic variance estimates of Swank and Fano factors

Purpose: Variance estimates for detector energy resolution metrics can be used as stopping criteria in Monte Carlo simulations for the purpose of ensuring a small uncertainty of those metrics and for the design of variance reduction techniques. Methods: The authors derive an estimate for the variance of two energy resolution metrics, the Swank factor and the Fano factor, in terms of statistical moments that can be accumulated without significant computational overhead. The authors examine the accuracy of these two estimators and demonstrate how the estimates of the coefficient of variation of the Swank and Fano factors behave with data from a Monte Carlo simulation of an indirect x-ray imaging detector. Results: The authors' analyses suggest that the accuracy of their variance estimators is appropriate for estimating the actual variances of the Swank and Fano factors for a variety of distributions of detector outputs. Conclusions: The variance estimators derived in this work provide a computationally convenient way to estimate the error or coefficient of variation of the Swank and Fano factors during Monte Carlo simulations of radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the effect of characteristic x-rays in cadmium zinc telluride detectors under breast computerized tomography operating conditions

A number of research groups have been investigating the use of dedicated breast computerized tomography (CT). Preliminary results have been encouraging, suggesting an improved visualization of masses on breast CT as compared to conventional mammography. Nonetheless, there are many challenges to overcome before breast CT can become a routine clinical reality. One potential improvement over current breast CT prototypes would be the use of photon counting detectors with cadmium zinc telluride (CZT) (or CdTe) semiconductor material. These detectors can operate at room temperature and provide high detection efficiency and the capability of multi-energy imaging; however, one factor in particular that limits image quality is the emission of characteristic x-rays. In this study, the degradative effects of characteristic x-rays are examined when using a CZT detector under breast CT operating conditions. Monte Carlo simulation software was used to evaluate the effect of characteristic x-rays and the detector element size on spatial and spectral resolution for a CZT detector used under breast CT operating conditions. In particular, lower kVp spectra and thinner CZT thicknesses were studied than that typically used with CZT based conventional CT detectors. In addition, the effect of characteristic x-rays on the accuracy of material decomposition in spectral CT imaging was explored. It was observed that when imaging with 50-60 kVp spectra, the x-ray transmission through CZT was very low for all detector thicknesses studied (0.5–3.0 mm), thus retaining dose efficiency. As expected, characteristic x-ray escape from the detector element of x-ray interaction increased with decreasing detector element size, approaching a 50% escape fraction for a 100 μm size detector element. The detector point spread function was observed to have only minor degradation with detector element size greater than 200 μm and lower kV settings. Characteristic x-rays produced increasing distortion in the spectral response with decreasing detector element size. If not corrected for, this caused a large bias in estimating tissue density parameters for material decomposition. It was also observed that degradation of the spectral response due to characteristic x-rays caused worsening precision in the estimation of tissue density parameters. It was observed that characteristic x-rays do cause some degradation in the spatial and spectral resolution of thin CZT detectors operating under breast CT conditions. These degradations should be manageable with careful selection of the detector element size. Even with the observed spectral distortion from characteristic x-rays, it is still possible to correctly estimate tissue parameters for material decomposition using spectral CT if accurate modeling is used.

36 MATERIALS SCIENCE↗

Position measurements in the de Broglie-Bohm interpretation of quantum mechanics

The de Broglie-Bohm interpretation of quantum mechanics assigns positions and trajectories to particles. We analyze the validity of a formula for the velocities of Bohmian particles which makes the analysis of these trajectories particularly simple. We apply it to particle detectors of four different types and show that the detectors of three of these types lead to 'surrealistic trajectories', i.e., leave a trace where the Bohmian particle was not present. - Highlights: Black-Right-Pointing-Pointer We perform computer simulation of Bohmian trajectories for position detectors. Black-Right-Pointing-Pointer A simplified velocity formula provides very precise (or exact) Bohmian trajectories. Black-Right-Pointing-Pointer Spin, phase, and Bohmian velocity type detectors exhibit surrealistic trajectories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗