Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Recovery Act: A Measurement -- Management Technology for Improving Energy Efficiency in Data Centers and Telecommunication Facilities (Final Technical Report)

Data center (DC) electricity use is increasing at an annual rate of over 20% and presents a concern for the Information Technology (IT) industry, governments, and the society. A large fraction of the energy use is consumed by the compressor cooling to maintain the recommended operating conditions for IT equipment. The most common way to improve the DC efficiency is achieved by optimally provisioning the cooling power to match the global heat dissipation in the DC. However, at a more granular level, the large range of heat densities of today's IT equipment makes the task of provisioning cooling power optimized to the level of individual computer room air conditioning (CRAC) units much more challenging. Distributed sensing within a DC enables the development of new strategies to improve energy efficiency, such as hot spot elimination through targeted cooling, matching power consumption at rack level with workload schedule, and minimizing power losses. The scope of Measurement and Management Technologies (MMT) is to develop a software tool and the underlying sensing technology to provide critical decision support and control for DC and telecommunication facilities (TF) operations. A key aspect of MMT technology is integration of modeling tools to understand how changes in one operational parameter affect the overall DC response. It is demonstrated that reduced ordered models for DC can generate, in less than 2 seconds computational time, a three dimensional thermal model in a 50 kft 2 DC. This rapid modeling enables real time visualization of the DC conditions and enables "0what if" scenarios simulations to characterize response to "disturbances". One such example is thermal zone modeling that matches the cooling power to the heat generated at a local level by identifying DC zones cooled by a specific CRAC. Turning off a CRAC unit can be simulated to understand how the other CRAC utilization changes and how server temperature responds. Several new sensing technologies were added to the existing MMT platform: (1) air contamination (corrosion) sensors, (2) power monitoring, and (3) a wireless environmental sensing network. All three technologies are built on cost effective sensing solutions that increase the density of sensing points and enable high resolution mapping of DCs. The wireless sensing solution enables Air Conditioning Unit (ACU) control while the corrosion sensor enables air side economization and can quantify the risk of IT equipment failure due to air contamination. Validation data for six test sites demonstrate that leveraging MMT energy efficiency solutions combined with industry best practices results in an average of 20% reduction in cooling energy, without major infrastructure upgrades. As an illustration of the unique MMT capabilities, a data center infrastructure efficiency (DCIE) of 87% (industry best operation) was achieved. The technology is commercialized through IBM System and Technology Lab Services that offers MMT as a solution to improve DC energy efficiency. Estimation indicates that deploying MMT in existing DCs can results in an 8 billion kWh savings and projection indicates that constant adoption of MMT can results in obtainable savings of 44 billion kWh in 2035. Negotiations are under way with business partners to commercialize/license the ACU control technology and the new sensor solutions (corrosion and power sensing) to enable third party vendors and developers to leverage the energy efficiency solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Energy Efficiency Potential of Cloud-Based Software: A U.S. Case Study

The energy use of data centers is a topic that has received much attention, given that data centers currently account for 1-2% of global electricity use. However, cloud computing holds great potential to reduce data center energy demand moving forward, due to both large reductions in total servers through consolidation and large increases in facility efficiencies compared to traditional local data centers. However, analyzing the net energy implications of shifts to the cloud can be very difficult, because data center services can affect many different components of society’s economic and energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clusters of galaxies up to z = 1.5 identified from photometric data of the Dark Energy Survey and unWISE

ABSTRACT Using photometric data from the Dark Energy Survey and the Wide-field Infrared Survey Explorer, we estimate photometric redshifts for 105 million galaxies using the nearest-neighbour algorithm. From such a large data base, 151 244 clusters of galaxies are identified in the redshift range of 0.1 < z ≲ 1.5 based on the overdensity of the total stellar mass of galaxies within a given photometric redshift slice, among which 76 826 clusters are newly identified and 30 477 clusters have a redshift z > 1. We cross-match these clusters with those in the catalogues identified from the X-ray surveys and the Sunyaev–Zel’dovich (SZ) effect by the Planck, South Pole Telescope and Atacama Cosmology Telescope surveys, and get the redshifts for 45 X-ray clusters and 56 SZ clusters. More than 95 per cent SZ clusters in the sky region have counterparts in our catalogue. We find multiple optical clusters in the line of sight towards about 15 per cent of SZ clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Modeling and Installation: Preprint

The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device, the thermosyphon cooler (TSC), with an open cooling tower. A combination of equipment and controls, this new heat rejection system embraces the 'smart use of water,' using evaporative cooling when it is most advantageous and then saving water and modulating toward increased dry sensible cooling as system operations and ambient weather conditions permit. Innovative fan control strategies ensure the most economical balance between water savings and parasitic fan energy. The unique low-pressure-drop design of the TSC allows water to be cooled directly by the TSC evaporator without risk of bursting tubes in subfreezing ambient conditions. Johnson Controls partnered with the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories to deploy the TSC as a test bed at NREL's high-performance computing (HPC) data center in the first half of 2016. Located in NREL's Energy Systems Integration Facility (ESIF), this HPC data center has achieved an annualized average power usage effectiveness rating of 1.06 or better since 2012. Warm-water liquid cooling is used to capture heat generated by computer systems direct to water; that waste heat is either reused as the primary heat source in the ESIF building or rejected using evaporative cooling. This data center is the single largest source of water and power demand on the NREL campus, using about 7,600 m3 (2.0 million gal) of water during the past year with an hourly average IT load of nearly 1 MW (3.4 million Btu/h) -- so dramatically reducing water use while continuing efficient data center operations is of significant interest. Because Sandia's climate is similar to NREL's, this new heat rejection system being deployed at NREL has gained interest at Sandia. Sandia's data centers utilize an hourly average of 8.5 MW (29 million Btu/h) and are also one of the largest consumers of water on Sandia's site. In addition to describing the installation of the TSC and its integration into the ESIF, this paper focuses on the full heat rejection system simulation program used for hourly analysis of the energy and water consumption of the complete system under varying operating scenarios. A follow-up paper will detail the test results. The evaluation of the TSC's performance at NREL will also determine a path forward at Sandia for possible deployment in a large-scale system not only for data center use but also possibly site wide.

97 MATHEMATICS AND COMPUTING↗

An improved method for direct incident solar radiation calculation from hourly solar insolation data in building energy simulation

Solar radiation considerably influences the energy consumption of buildings and the power production of building integrated photovoltaic (BIPV) systems. Hourly solar insolation (Wh/m 2 ), represented as the amount of solar irradiance collected on the ground during a 1-h period, is the most common solar radiation data available and widely used in weather files applied in building energy modeling programs (BEMPs). Because the solar beam and position vary over time, the use of hourly insolation data as the input might result in errors in the estimation of the direct incident solar radiation on a particular surface. In this study, methods used in BEMPs for direct incident solar radiation calculations are first analyzed, and an improved method adopting a new algorithm for estimating the solar irradiance is proposed. Furthermore, the algorithm assumes that the solar irradiance changes linearly within a 1-h period and can be estimated based on the solar irradiance at the half clock and slope. The collected direct normal solar irradiance data of 2016 from eight solar radiation stations in China were used to demonstrate the proposed method and evaluate its performance by comparing the results with those from three conventional methods used in BEMPs along with the ground truth measurements. In addition, in this study, factors affecting the accuracy of the calculation results are explored. The results of the estimated direct incident solar radiation show that the proposed method achieves the best accuracy, followed by the methods used in DOE-2, EnergyPlus, and DeST. The proposed method guarantees that the hourly direct solar insolation will remain the same and reflects the variation in the direct solar irradiance across a 1-h time frame. The proposed method can be adopted in BEMPs to improve the accuracy of the solar radiation calculation, thereby improving the accuracy of the simulated building performance and the BIPV production.

14 SOLAR ENERGY↗

Energy Emergency and Preparedness Data: Frequently Asked Questions (FAQs) and Quick Guidance on Crisis Communications

State Energy Offices and Public Utility Commissions rely on timely, accurate, and actionable information to perform their energy emergency response duties and execute their roles as state energy security planners. In support of this need, the National Association of State Energy Officials (NASEO) and the National Association of Regulatory Utility Commissions (NARUC) hosted an Energy Security and Data Analysis Workshop in Washington, DC to identify energy security response and planning data sources; and to share successful methods of data use and integration in state, federal, and private sector tools. Following the workshop, NASEO and NARUC hosted two topical data-centric webinars based on state priorities to identify best practices in Geographic Information Systems (GIS) and Crisis Communications programs leveraged in energy assurance planning and response. The Crisis Communications webinar covered best practice tactics for how states can respond during energy emergencies and other crises. Based on the workshop and webinars, this document summarizes commonly used data sources and includes frequently asked questions which may be used by state energy officials (i.e., consisting of staff from Public Utility Commissions and Governor-designated State Energy Offices) to help guide them in developing or improving their Crisis Communications capabilities. A strong public information program is a key crisis management tool. Timely and accurate information helps prevent confusion and uncertainty and encourages public support and cooperation. As energy subject matter experts, state energy officials are vital in the distilling, clarifying, and conveying energy sector information and implications to decision-makers and the public. Other participants in an effective public information program include the Governor’s Office, other state agencies, local governments, energy providers, local businesses, state legislature, and the federal government. It is essential to provide stakeholders and the public with information about the nature, severity, and duration of an emergency because inadequate understanding and awareness can lead to undesirable actions that could further exacerbate the situation. Before a state government can provide information to the public, it must gather information, describe the emergency accurately, and develop recommendations to manage the situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NLR HPC Eagle Jobs Data and Additional Energy Metrics

Overview: Anonymized job-level records from the Eagle high-performance computing (HPC) system at the National Laboratory of the Rockies (NLR). Each record represents a Slurm batch job with scheduling metadata, resource requests, resource utilization, CPU/GPU energy consumption, and efficiency metrics. Sensitive fields (user, account, job name) are replaced with cryptographic hashes. System & Timeframe: Eagle was a 2,000-node, 8-petaflop system operated at NLR from 2019–2024. Data covers the full operational lifetime of the system. Slurm data was processed nightly; timestamps are in Mountain Time. Funding provided by the U.S. Department of Energy, EERE. Files: esif.hpc.eagle.job-anon.zip — Core anonymized job records (Hive-partitioned Parquet) esif.hpc.eagle.job-anon-energy-metrics.zip — Same records with additional iLO and Ganglia energy metrics datacard.md — Full dataset documentation ~13.8 million rows, 62 variables. Readable with PyArrow, pandas, DuckDB, Apache Spark, or any Parquet-compatible tool. Data Collection: Jobs collected via sacct through a pipeline: Eagle Jobs API → Redpanda → StreamSets → HPCMON API → PostgreSQL. Node-level power from iLO (HP Integrated Lights-Out); GPU power from Ganglia monitoring, joined to jobs via node lists and time ranges. Preprocessing: Anonymization of name, user, and account fields via cryptographic hashing Derived columns: queue_wait, cpu_eff, max_mem_eff Simplified job state mapping (e.g., "CANCELLED BY 12345" → "CANCELLED") QoS accounting rules (buy-in, standby, or Slurm QoS value) CPU energy estimated from TDP (200W, Intel Xeon Gold 6154, 18 cores) Timezone-aware columns (_tz) sourced from LEX accounting database to correctly handle DST transitions Key Variables: Scheduling: job_id, partition, state_simple, submit_time_tz, start_time_tz, end_time_tz, queue_waitResources: nodes_req/used, processors_req/used, memory_req, wallclock_req/used, gpus_requested Efficiency: cpu_eff, max_mem_eff Energy: cpu_energy_tdp_estimated_max/used_watt_hours, node_energy_total_watt_hours (iLO), gpu0/1_energy_total_watt_hours (Ganglia) Partitions: bigmem, bigmem-8600, bigscratch, csc, dav, ddn, debug, gpu, haswell, long, mono, short, standard Job States: CANCELLED, COMPLETED, FAILED, NODE_FAIL, OUT_OF_MEMORY, PENDING, RUNNING, TIMEOUT QoS Levels: Unknown, normal, buy-in, debug, penalty, high, standby Important Notes: Non-_tz timestamp columns may be off by one hour across DST boundaries; use _tz columns for time difference calculations Energy fields are null for jobs without monitoring coverage Job step records and raw Slurm JSONB fields are excluded from this extract Do not attempt to re-identify individuals from hashed fields

97 MATHEMATICS AND COMPUTING↗

An Autonomous MCP Bridge to Rucio: Enhancing Data Management Accessibility for High Energy Physics

The Rucio Data Management System [1] is an important tool used by High Energy Physics experiments, including those at Fermi National Accelerator Laboratory, to store and manage exabyte-scale scientific datasets. Despite its central role in coordinating data across globally distributed storage sites, Rucio's command line interface (CLI) presents a steep learning curve, and makes it difficult for scientists to navigate through. To solve this issue, a containerized Model Context Protocol (MCP) [2] server was built that connects Large Language Models directly to Rucio, allowing AI agents to handle data tasks by using simple, natural language rather than memorized terminal commands. The core engineering focus of this project was moving the server away from slow terminal commands that require text parsing and replacing them with a native Python Client API toolset and a planned REST API framework. Moving to the Python API handles data operations directly in memory, which helps clear up formatting errors, provides the AI with clean, structured JSON data and speeds up tool execution. To prove that the system actually works, a benchmarking pipeline was also built with various questions to test the AI across four different model configurations. The questions included finding data scopes, tracking down specific datasets, and checking replication rules. Through benchmarking, early runs showed that with raw terminal text, the model would get confused and stuck, whereas switching to the Python API to feed the AI clean, structured data yielded massive improvement. By creating an intelligent and autonomous bridge to a storage network, this project shows how AI can be implemented in scientific data management, which ultimately helps scientists at Fermilab spend less time sorting through data and more time focusing on their experiments and analysis.

Akella, Kashyap [William Rainey Harper Coll.]↗

Annual Technology Baseline (Including Supporting Data); NREL (National Renewable Energy Laboratory)

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), National Renewable Energy Laboratory provides an organized and centralized dataset that was reviewed by internal and external experts. It uses the best information from the Department of Energy laboratory's renewable energy analysts and Energy Information Administration information for conventional technologies. The ATB will be updated annually in order to provide an up-to-date repository of current and future cost and performance data. Going forward, we plan to revise and refine the values using best available information. The ATB includes both a presentation with notes (PDF) and an associated Excel Workbook. The ATB includes the following electricity generation technologies: land-based wind; offshore wind; utility-scale solar PV; concentrating solar power; geothermal power; hydropower plants (upgrades to existing facilities, powering non-powered dams, and new stream-reach development); conventional coal; coal with carbon capture and sequestration; integrated gasification combined cycle coal; natural gas combustion turbines; natural gas combined cycle; conventional biopower. Nuclear laboratory's renewable energy analysts and Energy Information Administration information for conventional technologies. The ATB will be updated annually in order to provide an up-to-date repository of current and future cost and performance data. Going forward, we plan to revise and refine the values using best available information.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Brown dwarf census with the Dark Energy Survey year 3 data and the thin disc scale height of early L types

In this paper we present a catalogue of 11745 brown dwarfs with spectral types ranging from L0 to T9, photometrically classified using data from the Dark Energy Survey (DES) year 3 release matched to the Vista Hemisphere Survey (VHS) DR3 and Wide-field Infrared Survey Explorer (WISE) data, covering ≈2400 deg 2 up to i AB = 22. The classification method follows the same phototype method previously applied to SDSS-UKIDSS-WISE data. We note the most significant difference comes from the use of DES data instead of SDSS, which allow us to classify almost an order of magnitude more brown dwarfs than any previous search and reaching distances beyond 400 pc for the earliest types. Next, we also present and validate the GalmodBD simulation, which produces brown dwarf number counts as a function of structural parameters with realistic photometric properties of a given survey. We use this simulation to estimate the completeness and purity of our photometric LT catalogue down to i AB = 22, as well as to compare to the observed number of LT types. We put constraints on the thin disc scale height for the early L (L0–L3) population to be around 450 pc, in agreement with previous findings. For completeness, we also publish in a separate table a catalogue of 20863 M dwarfs that passed our colour cut with spectral types greater than M6. Both the LT and the late M catalogues are found at DES release page https://des.ncsa.illinois.edu/releases/other/y3-mlt.

79 ASTRONOMY AND ASTROPHYSICS↗

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nonparametric reconstruction of the dark energy equation of state from diverse data sets

The cause of the accelerated expansion of the Universe poses one of the most fundamental questions in physics today. In the absence of a compelling theory to explain the observations, a first task is to develop a robust phenomenological approach: If the acceleration is driven by some form of dark energy, then the phenomenology is determined by the form of the dark energy equation of state w(z) as a function of redshift. A major aim of ongoing and upcoming cosmological surveys is to measure w and its evolution at high accuracy. Since w(z) is not directly accessible to measurement, powerful reconstruction methods are needed to extract it reliably from observations. We have recently introduced a new reconstruction method for w(z) based on Gaussian process modeling. This method can capture nontrivial w(z) dependences and, most importantly, it yields controlled and unbiased error estimates. In this paper we extend the method to include a diverse set of measurements: baryon acoustic oscillations, cosmic microwave background measurements, and supernova data. We analyze currently available data sets and present the resulting constraints on w(z), finding that current observations are in very good agreement with a cosmological constant. In addition, we explore how well our method captures nontrivial behavior of w(z) by analyzing simulated data assuming high-quality observations from future surveys. We find that the baryon acoustic oscillation measurements by themselves already lead to remarkably good reconstruction results and that the combination of different high-quality probes allows us to reconstruct w(z) very reliably with small error bounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RE Data Explorer: Supporting Renewable Energy Zones to Enable Low Emission Development

This fact sheet overviews the benefits of using the RE Data Explorer tool to analyze and develop renewable energy zones. Renewable energy zones are developed through a transmission planning and approval process customized for renewable energy. RE Data Explorer analysis can feed into broader stakeholder discussions and allow stakeholders to easily visualize potential zones. Stakeholders can access pertinent data to inform transmission planning and enable investment.

54 ENVIRONMENTAL SCIENCES↗

A Search for Photons with Energies Above 2 × 10 17 eV Using Hybrid Data from the Low-Energy Extensions of the Pierre Auger Observatory

Ultra-high-energy photons with energies exceeding 10 17 eV offer a wealth of connections to different aspects of cosmic-ray astrophysics as well as to gamma-ray and neutrino astronomy. The recent observations of photons with energies in the 10 15 eV range further motivate searches for even higher-energy photons. In this paper, we present a search for photons with energies exceeding 2 × 10 17 eV using about 5.5 yr of hybrid data from the low-energy extensions of the Pierre Auger Observatory. The upper limits on the integral photon flux derived here are the most stringent ones to date in the energy region between 10 17 and 10 18 eV.

79 ASTRONOMY AND ASTROPHYSICS↗

Data and Analytics to Inform Energy Retrofit of High Performance Buildings

Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Analysis of Energy Code Compliance in Commercial Buildings

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Analysis of Energy Code Compliance in Commercial Buildings (Rev. 1)

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. The field study team implemented the pilot methodology, compiling a data set of 230 office and retail buildings in two climate zones. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This report is focused on the analysis of the collected data. The primary goal was to analyze the data collected during the field study and determine the actual energy cost impact of each measure in a non-compliance situation. The energy impact results allowed for ranking the measures to identify which have the highest potential for lost savings. These results combined with the time required to verify each measure will allow future compliance verification to focus on measures that had a large impact on energy use over the life of the building and those that have the greatest savings recovery potential per verification hour.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗