Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Modified formulation of a rate-dependent damage model for ductile materials

A modification to the rate-dependent damage and failure model developed by Addessio and Johnson [J. Appl. Phys. 74, 1640 (1993)] for ductile materials under high-rate loading is presented. In the current formulation the equilibrium stress, which is used to calculate the plastic strain rate and damage in the material, is defined as the orthogonal projection of the final stress onto an equilibrium yield surface, instead of being a projection of the trial stress onto the yield surface as is done in the original formulation. The modification makes the current formulation fully consistent with the viscoplasticity theory. An implicit algorithm is also presented for the modified model and numerical results of copper under uniaxial strain loading are given to show the features of the model and the algorithm. Comparisons with the results of the original formulation are also presented.

36 MATERIALS SCIENCE↗

Multimodal 3D characterization of voids in shock-loaded tantalum: Implications for ductile spallation mechanisms

Predicting the failure of crystalline materials at high strain rates requires knowledge of the underlying failure mechanisms and their dependence on microstructure. However, little experimental consensus exists on the underlying micromechanics of spallation. In this study, a 3D-EBSD characterization experiment is performed on tantalum prior to and after partial spallation by plate impact, which allowed for the statistical assessment of the microstructural neighborhoods surrounding incipient voids. In analyzing the resulting dataset containing 5884 grains and 467 voids, it is observed that the voids were roughly spherical and consistent in size throughout the spalled material. The voids mostly resided at quadruple points, at triple junctions, at grain boundaries, and within grains, in decreasing order of prevalence. Moreover, voids tended to form at grain boundaries with high degrees of plastic incompatibility, growing into the plastically soft grain but orienting primarily with or perpendicular to the loading direction. Here, the statistics from these analyses of 3D microstructural data support dynamic cavitation models for ductile spallation.

36 MATERIALS SCIENCE↗

A detailed investigation of the micromechanisms of compressive failure in open hole composite laminates

Micromechanisms responsible for compressive failure in open-hole composite laminates were investigated. Specimens containing circular center holes were loaded in compression to failure at a slow rate, and the surface damage development during loading was monitored. Several coupon compression tests were interrupted prior to catastrophic failure to allow for the assessment of fiber shear crippling and/or fiber microbuckling by NDE techniques. From these sectioning studies, the extent and mode of failure were determined, and a three-dimensional schematic of the shear crippling zone was developed. Results show that the majority of the damage in compression-loaded open-hole composite laminates is shear crippled or microbuckled 0-deg fibers; in many cases, however, the shear crippling damage within the 0-deg plies produced shear strains and damage in the adjacent off-axis plies.

Guynn, E. Gail↗

Material Testing of PH13-8MO H950 Steel for Xue-Wierzbicki Fracture Criterion Determination

Four tensile coupon designs of PH13-8Mo H950 steel were tested to failure using quasi-static rates to obtain data to calibrate the Xue-Wierzbicki failure model for ductile fracture. The tests recorded the force-displacement, location of the first crack, displacement to fracture, area reduction, and crack propagation path. The test method and coupon designs were adopted from Tomasz Wierzbicki’s “Calibration and evaluation of seven fracture models” report. The XueWierzbicki model predicts fracture based on accumulated equivalent plastic strain, stress triaxiality, and deviatoric state parameter. Calibrating the Xue-Wierzbicki failure model required testing four coupon designs to calculate the four free parameters in the model. The coupon designs tested a range of stress triaxialities with two axisymmetric tests, one shear test, and one plane stress test. The data obtained and presented in this report can be used to develop a Xue-Wierzbicki fracture model for PH13-8Mo H950 steel.

36 MATERIALS SCIENCE↗

Detailed Study of Emergency Diesel Generator Performance Using EPIX/RADS Database

A recent report was published by the U.S. Nuclear Regulatory Commission – Industry-Average Performance for Components and Initiating Events at U.S. Commercial Nuclear Power Plants, NUREG/CR-6928. That report characterized industry performance (generally covering 1998 – 2002) for 51 component types found in commercial nuclear power plants. For example, for emergency diesel generators, three failure modes were identified: fail to start and reach rated speed and voltage, fail to load and run for one hour, and fail to run beyond one hour. Data from the U.S. industry contained in the Equipment Performance and Information Exchange (EPIX) database maintained by The Institute for Nuclear Power Operations were used to evaluate the failure probabilities and rates for these failure modes, covering 1998 – 2002. The software package Reliability and Availability Database System (RADS) was used to search and process the EPIX data. In addition, train test and maintenance unavailability was characterized for 34 train types. As a follow-on effort to this report, several components will be analyzed in more detail each year. These detailed studies include more recent data and analyze various subcategories such as manufacturer, system, size and type (as applicable). In addition, engineering insights such as piece part contribution to each failure mode and failure cause will be determined. This paper summarizes the preliminary results for emergency diesel generators. EPIX data coverage was expanded to include 1998 – 2007 and reliability results were compared with unplanned demand performance (bus under voltage events requiring the emergency diesel generator to start, load and run) over the same period. In addition, performance by manufacturer was evaluated. Finally, piece part contributions and failure causes were determined for each failure mode.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Twenty-Five-Year Experience With Radical Chemoradiation for Anal Cancer

Purpose: To evaluate the prognostic factors, patterns of failure, and late toxicity in patients treated with chemoradiation (CRT) for anal cancer. Methods and Materials: Consecutive patients with nonmetastatic squamous cell carcinoma of the anus treated by CRT with curative intent between February 1983 and March 2008 were identified through the institutional database. Chart review and telephone follow-up were undertaken to collect demographic data and outcome. Results: Two hundred eighty-four patients (34% male; median age 62 years) were identified. The stages at diagnosis were 23% Stage I, 48% Stage II, 10% Stage IIIA, and 18% Stage IIIB. The median radiotherapy dose to the primary site was 54 Gy. A complete clinical response to CRT was achieved in 89% of patients. With a median follow-up time of 5.3 years, the 5-year rates of locoregional control, distant control, colostomy-free survival, and overall survival were 83% (95% confidence interval [CI] 78-88), 92% (95% CI, 89-96), 73% (95% CI, 68-79), and 82% (95% CI, 77-87), respectively. Higher T stage and male sex predicted for locoregional failure, and higher N stage predicted for distant metastases. Locoregional failure occurred most commonly at the primary site. Omission of elective inguinal irradiation resulted in inguinal failure rates of 1.9% and 12.5% in T1N0 and T2N0 patients, respectively. Pelvic nodal failures were very uncommon. Late vaginal and bone toxicity was observed in addition to gastrointestinal toxicity. Conclusions: CRT is a highly effective approach in anal cancer. However, subgroups of patients fare relatively poorly, and novel approaches are needed. Elective inguinal irradiation can be safely omitted only in patients with Stage I disease. Vaginal toxicity and insufficiency fractures of the hip and pelvis are important late effects that require prospective evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concomitant Cisplatin and Hyperfractionated Radiotherapy in Locally Advanced Head and Neck Cancer: 10-Year Follow-Up of a Randomized Phase III Trial (SAKK 10/94)

Purpose: To compare the long-term outcome of treatment with concomitant cisplatin and hyperfractionated radiotherapy versus treatment with hyperfractionated radiotherapy alone in patients with locally advanced head and neck cancer. Methods and Materials: From July 1994 to July 2000, a total of 224 patients with squamous cell carcinoma of the head and neck were randomized to receive either hyperfractionated radiotherapy alone (median total dose, 74.4 Gy; 1.2 Gy twice daily; 5 days per week) or the same radiotherapy combined with two cycles of cisplatin (20 mg/m{sup 2} for 5 consecutive days during weeks 1 and 5). The primary endpoint was the time to any treatment failure; secondary endpoints were locoregional failure, metastatic failure, overall survival, and late toxicity assessed according to Radiation Therapy Oncology Group criteria. Results: Median follow-up was 9.5 years (range, 0.1-15.4 years). Median time to any treatment failure was not significantly different between treatment arms (hazard ratio [HR], 1.2 [95% confidence interval {l_brace}CI{r_brace}, 0.9-1.7; p = 0.17]). Rates of locoregional failure-free survival (HR, 1.5 [95% CI, 1.1-2.1; p = 0.02]), distant metastasis-free survival (HR, 1.6 [95% CI, 1.1-2.5; p = 0.02]), and cancer-specific survival (HR, 1.6 [95% CI, 1.0-2.5; p = 0.03]) were significantly improved in the combined-treatment arm, with no difference in major late toxicity between treatment arms. However, overall survival was not significantly different (HR, 1.3 [95% CI, 0.9-1.8; p = 0.11]). Conclusions: After long-term follow-up, combined-treatment with cisplatin and hyperfractionated radiotherapy maintained improved rates of locoregional control, distant metastasis-free survival, and cancer-specific survival compared to that of hyperfractionated radiotherapy alone, with no difference in major late toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Cohort Study to Compare Treatment Results Between 2 Fractionation Schedules of High-Dose-Rate Intracavitary Brachytherapy (HDR-ICBT) in Patients With Cervical Cancer

Purpose: To compare the treatment results of 2 fractionation schedules for high-dose-rate intracavitary brachytherapy (HDR-ICBT) in patients with cervical cancer. Methods and Materials: From June 2001 through January 2008, 267 patients with stage IB-IVA cervical cancer were enrolled in the study. All patients underwent 4-field pelvic irradiation and HDR-ICBT. The median central and parametrial doses were 39.6 Gy and 45 Gy, respectively. Patient underwent either 6 Gy Multiplication-Sign 4 (HDR-4) (n=144) or 4.5 Gy Multiplication-Sign 6 (HDR-6) (n=123) to point A of ICBT using {sup 192}Ir isotope twice weekly. The rates of overall survival, locoregional failure, distant metastasis, proctitis, cystitis, and enterocolitis were compared between HDR-4 and HDR-6. Results: There were no significant differences in the demographic data between HDR-4 and HDR-6 except for total treatment time. The 5-year proctitis rates were 23.0% and 21.5% in HDR-4 and HDR-6 (P=.399), respectively. The corresponding rates of grade 2-4 proctitis were 18.7% and 9.6% (P=.060). The corresponding rates of grades 3-4 proctitis were 5.2% and 1.3% (P=.231). Subgroup analysis revealed that HDR-4 significantly increased grade 2-4 proctitis in patients aged {>=}62 years old (P=.012) but not in patients aged <62 years (P=.976). The rates of overall survival, locoregional failure, distant metastasis, cystitis, and enterocolitis were not significantly different between HDR-4 and HDR-6 schedules. Conclusion: The small fraction size of HDR-ICBT is associated with grade 2 proctitis without compromise of prognosis in elderly patients. This schedule is suggested for patients who tolerate an additional 2 applications of HDR-ICBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conversion of Questionnaire Data

During the survey, respondents are asked to provide qualitative answers (well, adequate, needs improvement) on how well material control and accountability (MC&A) functions are being performed. These responses can be used to develop failure probabilities for basic events performed during routine operation of the MC&A systems. The failure frequencies for individual events may be used to estimate total system effectiveness using a fault tree in a probabilistic risk analysis (PRA). Numeric risk values are required for the PRA fault tree calculations that are performed to evaluate system effectiveness. So, the performance ratings in the questionnaire must be converted to relative risk values for all of the basic MC&A tasks performed in the facility. If a specific material protection, control, and accountability (MPC&A) task is being performed at the 'perfect' level, the task is considered to have a near zero risk of failure. If the task is performed at a less than perfect level, the deficiency in performance represents some risk of failure for the event. As the degree of deficiency in performance increases, the risk of failure increases. If a task that should be performed is not being performed, that task is in a state of failure. The failure probabilities of all basic events contribute to the total system risk. Conversion of questionnaire MPC&A system performance data to numeric values is a separate function from the process of completing the questionnaire. When specific questions in the questionnaire are answered, the focus is on correctly assessing and reporting, in an adjectival manner, the actual performance of the related MC&A function. Prior to conversion, consideration should not be given to the numeric value that will be assigned during the conversion process. In the conversion process, adjectival responses to questions on system performance are quantified based on a log normal scale typically used in human error analysis (see A.D. Swain and H.E. Guttmann, 'Handbook of Human Reliability Analysis with Emphasis on Nuclear Power Plant Applications,' NUREG/CR-1278). This conversion produces the basic event risk of failure values required for the fault tree calculations. The fault tree is a deductive logic structure that corresponds to the operational nuclear MC&A system at a nuclear facility. The conventional Delphi process is a time-honored approach commonly used in the risk assessment field to extract numerical values for the failure rates of actions or activities when statistically significant data is absent.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Power Goals for NASA's Exploration Program

Exciting Future Programs ahead for NASA. Power is needed for all Exploration vehicles and for the missions. For long term missions as in Lunar and Mars programs, safe, high energy/ultra high energy batteries are required. Safety is top priority for human-rated missions. Two-fault tolerance to catastrophic failures is required for human-rated safety To meet power safety goals -inherent cell safety may be required; it can lessen complexity of external protective electronics and prevents dependency on hardware that may also have limitations. Inherent cell safety will eliminate the need to carry out screening of all cells (X-rays, vibration, etc.)

Jeevarajan, Judith A.↗

Phenomenological Studies of Macroscale Failure in Metals

Highlights of recent phenomenological studies of metal failure are given. Failure leading to spallation and fragmentation are typically of interest. The current ‘best model’ includes the following; a full history stress in tension; nucleation initiating dynamic relaxation; toward a tensile yield function; failure dependent on strain, strain rate, and temperature; a mean-preserving ‘macrodefect’ is introduced when failure occurs in tension; and multifield theoretical refinements

36 MATERIALS SCIENCE↗

Wind Turbine Main Bearing Rating Lives as Determined by IEC 61400-1 and ISO 281

This presentation studies the rating lives of wind turbine main bearings, as determined by the IEC 61400-1 and ISO 281 standards. A brief review of relevant bearing life theory and turbine design requirements is provided. This includes a discussion on possible shortcomings, including the existence (or not) of the bearing fatigue load limit and the validity of assuming linear damage accumulation. A detailed study is then undertaken to determine rating lives for two models of main bearing in a 1.5 MW wind turbine. Rating life assessment is carried out under different conditions, including various combinations of main bearing temperature, wind field characteristics, lubricant viscosity and contamination levels. Rating lives are found to be sufficiently above the desired 20 year design life for both bearing models under expected operating conditions. For the larger bearing, operational loads are shown to be below or close to the bearing fatigue load limit a vast majority of the time. Key sensitivities for rating life values are shown to be the temperature and contamination. Overall, the results of this study suggest that rating life assessment does not account for reported rates of main bearing failures in 1 to 3 MW wind turbines. In future work, it is recommended that efforts be undertaken to identify principal root causes of main bearing failures, possibly leading to a new application standard specific to this component. It is also recommended that impacts of partial wake impingement on main bearing rating lives are investigated.

ENGINEERING,WIND ENERGY↗

Numerical modeling of injection, stress and permeability enhancement during shear stimulation at the Desert Peak Enhanced Geothermal System

Creation of an Enhanced Geothermal System relies on stimulation of fracture permeability through self-propping shear failure that creates a complex fracture network with high surface area for efficient heat transfer. In 2010, shear stimulation was carried out in well 27-15 at Desert Peak geothermal field, Nevada, by injecting cold water at pressure less than the minimum principal stress. An order-of-magnitude improvement in well injectivity was recorded. In this work, we describe a numerical model that accounts for injection-induced stress changes and permeability enhancement during this stimulation. We use the coupled thermo-hydrological–mechanical simulator FEHM to (i) construct a wellbore model for non-steady bottom-hole temperature and pressure conditions during the injection, and (ii) apply these pressures and temperatures as a source term in a numerical model of the stimulation. A Mohr–Coulomb failure criterion and empirical fracture permeability is developed to describe permeability evolution of the fractured rock. The numerical model is calibrated using laboratory measurements of material properties on representative core samples and wellhead records of injection pressure and mass flow during the shear stimulation. The model captures both the absence of stimulation at low wellhead pressure (WHP ≤1.7 and ≤2.4 MPa) as well as the timing and magnitude of injectivity rise at medium WHP (3.1 MPa). Results indicate that thermoelastic effects near the wellbore and the associated non-local stresses further from the well combine to propagate a failure front away from the injection well. Elevated WHP promotes failure, increases the injection rate, and cools the wellbore; however, as the overpressure drops off with distance, thermal and non-local stresses play an ongoing role in promoting shear failure at increasing distance from the well.

15 GEOTHERMAL ENERGY↗

Helium release rates and ODH calculations from RHIC magnet cooling line failure

A catastrophic failure of the magnet cooling lines, similar to the LHC superconducting bus failure incident, could discharge cold helium into the RHIC tunnel and cause an Oxygen Deficiency Hazard (ODH) problem. A SINDA/FLUINT{reg_sign} model, which simulated the 4.5K/4 atm helium flowing through the magnet cooling system distribution lines, then through a line break into the insulating vacuum volumes and discharging via the reliefs into the RHIC tunnel, had been developed. Arc flash energy deposition and heat load from the ambient temperature cryostat surfaces are included in the simulations. Three typical areas: the sextant arc, the Triplet/DX/D0 magnets, and the injection area, had been analyzed. Results, including helium discharge rates, helium inventory loss, and the resulting oxygen concentration in the RHIC tunnel area, are reported. Good agreement had been achieved when comparing the simulation results, a RHIC sector depressurization test measurement, and some simple analytical calculations.

43 PARTICLE ACCELERATORS↗

Value of Duplex Ultrasound Assistance for Thromboaspiration and Dilation of Thrombosed Native Arterio-Venous Fistulae

Purpose: To evaluate the value of duplex ultrasound assistance during thromboaspiration of thrombosed arteriovenous fistulae for haemodialysis. Materials and Methods: We prospectively studied 54 thrombosed native fistulae (23 with total thrombosis and 31 with partial thrombosis), in which we performed manual thromboaspiration guided by ultrasonography associated with fluoroscopy. Results: The fistulae were located in the forearm (n = 39) or in the upper arm (n = 15) of 46 patients. Mean patient age was 65 years, and hypertension was the most common risk factor (74 %). Mean access age was 928 days (range 69-2,290), and most fistulae were on the left side (41 cases, 75.92 %). The success rate was 83 % in the total thrombosis group and 100 % in the partial thrombosis group. Including initial failures, the respective primary patency rates in the total thrombosis group and the partial thrombosis group were, respectively, 83 {+-} 8 % (n = 20) and 87 {+-} 6 % (n = 28) at 1 month, 39 {+-} 10 % (n = 10) and 61 {+-} 8 % (n = 20) at 6 months, and 17 {+-} 8 % (n = 5) and 26 {+-} 8 % (n = 9) at 1 year. The mean decrease of fluoroscopy time with ultrasound was 3 min (range 1-5). The mean decrease of radiation dose was 2.6 Gy cm Superscript-Two (range 0.9-4.3]. Conclusion: Ultrasound is a feasible and useful tool in the management of thrombosed native fistulae, thus decreasing radiation exposure, and has no detrimental effect on success rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization Of Flow Stress Of Different AA6082 Alloys By Means Of Hot Torsion Test

FEM simulations are become the most powerful tools in order to optimize the different aspects of the extrusion process and an accurate flow stress definition of the alloy is a prerequisite for a reliable effectiveness of the simulation. In the paper the determination of flow stress by means of hot torsion test is initially presented and discussed: the several approximations that are usually introduced in flow stress computation are described and computed for an AA6082 alloy in order to evidence the final effect on curves shapes. The procedure for regressing the parameters of the sinhyperbolic flow stress definition is described in detailed and applied to the described results. Then four different alloys, extracted by different casting batches but all namely belonging to the 6082 class, were hot torsion tested in comparable levels of temperature and strain rate up to specimen failure. The results are analyzed and discussed in order to understand if a mean flow stress behavior can be identified for the whole material class at the different tested conditions or if specific testing conditions (chemical composition of the alloy, specimen shape, etc) influence the materials properties to a higher degree.

36 MATERIALS SCIENCE↗