Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

LDRD 227829: Multifunctional Composite LDRD: Radiation Effect on CeO 2 -HDPE Composites

Commercial high-density polyethylene (HDPE) is lightweight with excellent mechanical properties but has limited thermal stability. To enhance this, lanthanide-based nanomaterials like CeO 2 were mixed with HDPE. Using a twin-screw extruder improved dispersion. This study examines the effects of neutron, X-rays and gamma radiation on the crystallinity of polymer of CeO 2 -HDPE composites.

36 MATERIALS SCIENCE↗

Radioisotope identification method for poorly resolved gamma-ray spectrum of nuclear security concern

Gamma-ray signal can be used as a fingerprint for radioisotope identification. In the context of radioactive and nuclear materials security at the border control point, the detection task can present a significant challenge due to various constraints such as the limited measurement time, the shielding conditions, and the noise interference. This study proposes a novel method to identify the signal of one or several radioisotopes from a poorly resolved gamma-ray spectrum. In this method, the noise component in the raw spectrum is reduced by the wavelet decomposition approach, and the removal of the continuum background is performed using the baseline determination algorithm. Finally, the identification of radioisotope is completed using the matrix linear regression method. The proposed method has been verified by experiments using the poorly resolved gamma-ray signals from various scenarios including single source, mixing of natural uranium with five of the most common industrial radioactive sources (57Co, 60Co, 133Ba, 137Cs, and 241Am). The preliminary results show that the proposed algorithm is comparable with the commercial method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of gamma irradiation on structural, thermal and antibacterial properties of HPMC/ZnO nanocomposites

This work was carried out to evaluate the effect of gamma irradiation on the structural, thermal and antibacterial properties of HPMC/ZnO nanocomposite films exposed to Cobalt-60 (Average energy: 1.25 MeV). The X-ray diffraction study revealed that the crystallite size (L in Å) decreased as irradiation dose increased. The crystallinity (X{sub c}) of the nanocomposites initially increased and at higher doses it was decreased. The thermal stability of the nanocomposites increased up to 50 kGy and after that decreased as the irradiation dose increased. But, HPMC/ZnO nanocomposite films, showed a promising range of antimicrobial activity against tested micro-organisms making nanocomposites suitable for food packing and other biomedical applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A LAST LOOK AT THE MICROWAVE HAZE/BUBBLES WITH WMAP

The microwave 'haze' was first discovered with the initial release of the full sky data from the Wilkinson Microwave Anisotropy Probe (WMAP). It is diffuse emission toward the center of our Galaxy with spectral behavior that makes it difficult to categorize as any of the previously known emission mechanisms at those wavelengths. With now seven years of WMAP data publicly available, we have learned much about the nature of the haze, and with the release of data from the Fermi Gamma-Ray Space Telescope and the discovery of the gamma-ray haze/bubbles, we have had a spectacular confirmation of its existence at other wavelengths. As the WMAP mission winds down and the Planck mission prepares to release data, I take a last look at what WMAP has to tell us about the origin of this unique Galactic feature. Much like the gamma rays, the microwave haze/bubbles is/are elongated in latitude with respect to longitude by a factor of roughly two, and at high latitudes, the microwave emission cuts off sharply above {approx}35 Degree-Sign (compared to {approx}50 Degree-Sign in the gammas). The hard spectrum of electrons required to generate the microwave synchrotron is consistent with that required to generate gamma-ray emission via inverse Compton scattering, though it is likely that these signals result from distinct regions of the spectrum ({approx}10 GeV for the microwaves and {approx}1 TeV for the gammas). While there is no evidence for significant haze polarization in the seven-year WMAP data, I demonstrate explicitly that it is unlikely such a signal would be detectable above the noise.

79 ASTRONOMY AND ASTROPHYSICS↗

GAMSOR: Gamma Source Preparation and DIF3D Flux Solution

Nuclear reactors that rely upon the fission reaction have two modes of thermal energy deposition in the reactor system: neutron absorption and gamma absorption. The gamma rays are typically generated by neutron absorption reactions or during the fission process which means the primary driver of energy production is of course the neutron interaction. In conventional reactor physics methods, the gamma heating component is ignored such that the gamma absorption is forced to occur at the gamma emission site. For experimental reactor systems like EBR-II and FFTF, the placement of structural pins and assemblies internal to the core leads to problems with power heating predictions because there is no fission power source internal to the assembly to dictate a spatial distribution of the power. As part of the EBR-II support work in the 1980s, the GAMSOR code was developed to assist analysts in calculating the gamma heating. The GAMSOR code is a modified version of DIF3D and actually functions within a sequence of DIF3D calculations. The gamma flux in a conventional fission reactor system does not perturb the neutron flux and thus the gamma flux calculation can be cast as a fixed source problem given a solution to the steady state neutron flux equation. This leads to a sequence of DIF3D calculations, called the GAMSOR sequence, which involves solving the neutron flux, then the gamma flux, then combining the results to do a summary edit. In this manuscript, we go over the GAMSOR code and detail how it is put together and functions. We also discuss how to setup the GAMSOR sequence and input for each DIF3D calculation in the GAMSOR sequence. With the GAMSOR capability, users can take any valid steady state DIF3D calculation and compute the power distribution due to neutron and gamma heating. The MC2-3 code is the preferable companion code to use for generating neutron and gamma cross section data, but the GAMSOR code can accept cross section data from other sources. To further this aspect, an additional utility code was created which demonstrates how to merge the neutron and gamma cross section data together to carry out a simultaneous solve of the two systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dosimetry for radiobiological studies of the human hematopoietic system

A system for estimating individual bone marrow doses in therapeutic radiation exposures of leukemia patients was studied. These measurements are used to make dose response correlations and to study the effect of dose protraction on peripheral blood cell levels. Three irradiators designed to produce a uniform field of high energy gamma radiation for total body exposures of large animals and man are also used for radiobiological studies.

Beck, W. L.↗

The response of a 0.03-cm silicon detector to a mixed neutron and gamma field as a function of shield material and thickness

The neutron and gamma radiation from a MHW-RTG was used to evaluate the total response of a shielded 0.3-mm silicon detector. The generator employs a 2200 W(th) PuO2 heat source concept known as the HELIPAK. The total integrated neutron and gamma ray fluxes at 100 cm away from the source along the radial direction were 1.67 x 1,000 n/sq cm/s and 1.49 x 10,000 gamma sq cm/s, respectively. Experimental values of the response function of the shielded silicon detector were used to determine the total counting rates due to photons at bias energies ranging from 50 to 200 keV. For neutrons, analytically computed response functions were used to determine the total counting rates at the same bias energies. It was found that for an aluminum shield the neutrons are not significant, regardless of the thickness of the shield. However, the magnitude of the total counting rate due to neutrons increases with increased atomic number of the shield and becomes comparable to the counting rate due to photons for a platinum shield thickness of 5 cm.

Taherzadeh, M.↗

Preliminary Evaluation of Commercial Off the Shelf (COTS) Packing Materials for Flight Medication Dispenser (FMD) Technology Development

With the advent of longer duration space missions, pharmaceutical use in space has increased. During the first 33 space shuttle missions, crew members took more than 500 individual doses of 31 different medications . Anecdotal reports from crew members described medications as generally "well tolerated" and "effective". However, reported use of increased medication doses and discrepancies in ground vs. flight efficacy may result from reduced potency or altered bioavailability due to changes in chemical and/or physical parameters of pharmaceutical stability. Based on preliminary results from a ground-based irradiation and an inflight study on pharmaceutical stability, three susceptible medications, Amoxicillin/Clavulanate and Sulfamethoxazole/trimethoprim antibiotics tablets and promethazine (PMZ), an antihistamine were selected for testing using two types of Oliver-Tolas bags, TPC-1475(Clear) and TPF-0599B (Foil) for radiation Shielding effectiveness. The material composition of the bags included aluminum coated Mylar sheathing coated with multifunctional nanocomposities based on polyethylene with dispersed boron-rich nanophases. Two bags of each medication were irradiated for different time intervals with 14.6 rad/min to achieve 0.1 Gy, 1 Gy and 10 Gy of cumulative radiation dose. Active pharmaceutical content (API) in each medication was determined and results analyzed. No significant difference in API content was observed between control and irradiated samples for both antibiotic tablets suggesting both types of bags may offer protection against gamma radiation; results with PMZ were inconclusive. These preliminary results suggest that Oliver-Tolas TPL-1475 and TPF-0599B materials may possess characteristics suitable for protection against ionizing radiation and can be considered for designing and further testing of FMD technology.

Du, Brian↗

Channeling and radiation experiments at SLAC

Since 2014, a SLAC-Aarhus-Ferrara-CalPoly collaboration augmented by members of ANL and MIT has performed electron and positron channeling experiments using bent silicon crystals at the SLAC End Station A Test Beam as well as the FACET accelerator test facility. These experiments have revealed a remarkable channeling efficiency of about 24% under our conditions. Volume reflection is even more efficient with almost the whole beam taking part in the reflection process. A positron experiment demonstrated quasi-channeling oscillations for the first time at high beam energy. In our most recent experiment we measured the spectrum of gamma radiation for crystal orientations covering channeling and volume reflection. We report this series of experiments supports the development of more advanced crystalline devices capable e.g. of producing narrow-band gamma rays with electron beams or studying the interaction of the electrons with the wakefields generated in the crystal at high beam intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CGRO Observations

This final report presents an investigation of the CGRO (Compton Gamma Ray Observatory) observations. The investigation includes: Diffuse Gamma-Ray Emission at High Latitudes; and Echoes in X-Ray Novae; A Localized Excess of Gamma-Radiation; Transient Hard X-Ray Emission from Globular Clusters; and A Search for Be/X-Ray Binaries in Hard X-Rays; Hard X-Ray Emission from X-Ray Bursters; X-Ray Transients in Star-Forming Regions; Gamma-ray Emission from Globular Clusters; Shock High Energy Emission from Be-Star/Pulsar System PSR 1259-63m; Gamma-Ray Spectroscopy of Nearby OB Associations; Long Term Hard X-Ray Monitoring of X-Ray Busters; and Periodic Hard X-Ray Emission from GRO J1849-03.

Kaaret, Philip↗

Simulated Irradiation of Samples in HFIR for use as Possible Test Materials in the MPEX (Material Plasma Exposure Experiment) Facility

The importance of Plasma Material Interaction (PMI) is a major concern in fusion reactor design and analysis. The Material-Plasma Exposure eXperiment (MPEX) facility will explore PMI under fusion reactor plasma conditions. Samples with accumulated displacements per atom (DPA) damage produced by irradiations in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) will be studied in the MPEX facility. The project presented in this paper involved performing assessments of the induced radioactivity and resulting radiation fields of a variety of potential fusion reactor materials. The scientific code packages MCNP and SCALE were used to simulate irradiation of the samples in HFIR; generation and depletion of nuclides in the material and the subsequent composition, activity levels, gamma radiation fields, and resultant dose rates as a function of cooling time. These state-of-the-art simulation methods were used in addressing the challenge of the MPEX project to minimize the radioactive inventory in the preparation of the samples for inclusion in the MPEX facility.

Ellis, Ronald James↗

The compact neutron spectrometer at ASDEX Upgrade

The first neutron spectrometer of ASDEX Upgrade (AUG) was installed in November 2008. It is a compact neutron spectrometer (CNS) based on a BC501A liquid scintillating detector, which can simultaneously measure 2.45-MeV and 14-MeV neutrons emitted from deuterium (D) plasmas and {gamma} radiation. The scintillating detector is coupled to a digital pulse shape discrimination data acquisition (DPSD) system capable of count rates up to 10{sup 6} s{sup -1}. The DPSD system can operate in acquisition and processing mode. With the latter n-{gamma} discrimination is performed off-line based on the two-gate method. The paper describes the tests of the CNS and its installation at AUG. The neutron emission from the D plasma measured during a discharge with high auxiliary heating power was used to validate the CNS performance. The study of the optimal settings for the DPSD data processing to maximize the n-{gamma} discrimination capability of the CNS is reported. The CNS measured both 2.45-MeV and 14-MeV neutrons emitted in AUG D plasmas with a maximum count rate of 5.4 x10{sup 5} s{sup -1} (>10 times higher than similar spectrometers previously achieved) with an efficiency of 9.3 x 10{sup -10} events per AUG neutron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the binary nature of cosmic gamma-ray burst sources

The binary model of gamma ray burst sources wherein the bursts are emitted by a collapsed object in a close-binary stellar system and a small fraction of the gamma radiation is reprocessed into optical radiation in the surface layers of a companion star is considered, and it is concluded that the model is viable. In particular, under the assumption that the optical flashes discovered by Schaefer (1981) and Schaefer et al. (1984) were produced by gamma-ray bursts of about the same intensity as those observed, it is found that nearby binary systems with secondaries whose masses are less than about 0.06 solar mass can fit all the observational constraints for the three optical/gamma-ray pair events.

Rappaport, S. A.↗

Dosimetry is Key to Good Epidemiology: Workers at Mallinckrodt Chemical Works had Seven Different Source Exposures

Mallinckrodt Chemical Works was the earliest uranium processing facility in the Manhattan Project, beginning in 1942. Even then, concern existed about possible health effects resulting from exposure to radiation and pitchblende dust. This concern was well founded as the facility processed Belgian Congo pitchblende ore that was up to 60% pure uranium with high 235 U content and up to 100 mg of radium per ton. Workers were exposed to external gamma radiation plus internal radiation from inhalation and ingestion of pitchblende dust (uranium, radium, and silica). Multiple sources of exposure were available for organ dose reconstruction to a degree unique for an epidemiologic study. Personal film badge measures available from 1945 captured external exposures. Additional external exposure included 15,518 occupational medical x-rays and 210 radiation exposure records from other facilities outside of Mallinckrodt employment. Organ dose calculations considered organ-specific coefficients that account for photon energy and job-specific orientation of workers to the radiation source during processing. Intakes of uranium and radium were based on 39,451 uranium urine bioassays and 2,341 breath radon measurements, and International Commission on Radiological Protection (ICRP) Publication 68 biokinetic models were used to estimate organ-specific radiation absorbed dose. Estimates of exposure to airborne radon and its short-lived progeny were based on radon measurements in work areas where radium-containing materials were handled or stored, together with estimated exposure times in these areas based on job titles. Dose estimates for radon and its short-lived progeny were based on models and methods recently recommended in ICRP Publication 137. This comprehensive dosimetric approach follows methods outlined by the National Council on Radiation Protection Scientific Committee 6-9 for the Million Worker Study. Annual doses were calculated for six organs: lung, brain, heart, kidney, colon and red bone marrow. Finally, evaluation and adjustment for individual cumulative measures of pitchblende dust inhalation were made for lung and kidney diseases.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Radiation Weather Station: Development of a Continuous Monitoring System for the Collection, Analysis, and Display of Environmental Radiation Data

Due to heightened fear surrounding the possibility of future terrorism involving nuclear weapons and radiological dispersive devices, compounded by nonroutine nuclear power plant releases such as from emergencies or accidents, interest in contamination levels of environmental radiation has spiked. This project sought to develop a continuously operational radiation-monitoring system, with graphically visualized data easily accessible to the public. Because this continuing project is housed at a university facility, it bears no connection to perceived political or commercial interests, generally increasing the credibility of the endeavor. Outdoor weather and radiation parameters were gathered by sensors installed on the rooftop of a two-story building. A display and cloud service website was used to project the live data in an understandable format. A correlation was observed between weather and visibly heightened levels of gamma radiation. Furthermore, the goal of this paper is to share and highlight the overall hardware selection and the unique software challenges encountered when developing a robust collection and analysis system, along with the challenges of displaying meteorological and radiological data in a clear and concise fashion.

07 ISOTOPE AND RADIATION SOURCES↗

Long-Term Effects of Ionizing Radiation on Gene Expression in a Zebrafish Model

Understanding how initial radiation injury translates into long-term effects is an important problem in radiation biology. Here, we define a set of changes in the transcription profile that are associated with the long-term response to radiation exposure. The study was performed in vivo using zebrafish, an established radiobiological model organism. To study the long-term response, 24 hour post-fertilization embryos were exposed to 0.1 Gy (low dose) or 1.0 Gy (moderate dose) of whole-body gamma radiation and allowed to develop for 16 weeks. Liver mRNA profiles were then analyzed using the Affymetrix microarray platform, with validation by quantitative PCR. As a basis for comparison, 16-week old adults were exposed at the same doses and analyzed after 4 hours. Statistical analysis was performed in a way to minimize the effects of multiple comparisons. The responses to these two treatment regimes differed greatly: 360 probe sets were associated primarily with the long-term response, whereas a different 2062 probe sets were associated primarily with the response when adults of the same age were irradiated 4 hours before exposure. Surprisingly, a ten-fold difference in radiation dose (0.1 versus 1.0 Gy) had little effect. Analysis at the gene and pathway level indicated that the long-term response includes the induction of cytokine and inflammatory regulators and transcription and growth factors. The acute response includes the induction of p53 target genes and modulation of the hypoxia-induced transcription factor-C/EBP axis. Results help define genes and pathways affected in the long-term, low and moderate dose radiation response and differentiate them from those affected in an acute response in the same tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Detection of a long-duration solar gamma-ray flare on Jun. 11, 1991 with EGRET on Compton-GRO

On 11 Jun. 1991, the Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (Comption-GRO) observed high energy gamma radiation above 30 MeV from the Sun following an intense flare around 2:00 Universal Time (UT). After the decay of most of the x ray flare, which caused nearly complete deadtime losses in EGRET, high energy emission was registered during the interval from about 3:30 UT to at least 10:30 UT. Gamma rays were detected up to energies above 1 GeV. The solar origin of the emission is assured by the time profile of the gamma ray count rate and by time resolved sky maps, which show a clear maximum at the position of the sun. The gamma ray lightcurve of the flare can be described with two components: a fast decaying emission with an e-folding time constant of about 25 minutes and a slow decay with about 255 minutes. There are indications for a spectral evolution with time, such that the emission below 100 MeV fades away earlier than the 100 to 300 MeV radiation, roughly in the time scale of the fast component. The spectrum of the flare can be fitted with a composite of a proton generated pion neutral spectrum and an electron bremsstrahlung component. The latter can be identified with the fast decaying component of the lightcurve.

Kanbach, G.↗

Pair Production near Threshold in Pulsar Magnetic Fields

In pulsar polar cap models, curvature radiation gamma rays produce e(+)e(-) pairs in the strong magnetic fields near the surface of the neutron star. While these gamma rays have energies E sub gamma mc(2), they also propagate at very small angles to the fields, such that the threshold condition, E gamma 2mc(2)/sin theta is just barely satisfied when they pair produce. Threshold effects on the pair production attenuation coefficient, which are due to the discreteness of the e(+)e(-) Landau states, must therefore be considered when computing the mean free paths of curvature radiation photons in pulsar magnetic fields. These effects, which are not incorporated in the asymptotic expression for the attenuation coefficient, have some interesting consequences for pulsar models. Since pair production is suppressed near threshold, the photon mean free paths are longer than previously thought. In magnetic fields approximately 6x10 approximately G, the pairs tend to be produced in the ground state Landau level and will not synchrotron radiate. Since synchrotron radiation is an essential ingredient in the electromagnetic cascades which produce low energy pairs above the acceleration region, pulsars with very high magnetic fields may not produce many pairs.

Harding, A. K.↗