Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A surface mechanism for O 3 production with N 2 addition in dielectric barrier discharges

Ozone, O 3 , is a strong oxidizing agent often used for water purification. O 3 is typically produced in dielectric barrier discharges (DBDs) by electron-impact dissociation of O 2 , followed by three-body association reactions between O and O 2 . Previous studies on O 3 formation in low-temperature plasma DBDs have shown that O 3 concentrations can drop to nearly zero after continued operation, termed the ozone-zero phenomenon (OZP). Including small (<4%) admixtures of N 2 can suppress this phenomenon and increase the O 3 production relative to using pure O 2 in spite of power deposition being diverted from O 2 to N 2 and the production of nitrogen oxides, N x O y . The OZP is hypothesized to occur because O 3 is destroyed on the surfaces in contact with the plasma. Including N 2 in the gas mixture enables N atoms to occupy surface sites that would otherwise participate in O 3 destruction. The effect of N 2 in ozone-producing DBDs was computationally investigated using a global plasma chemistry model. A general surface reaction mechanism is proposed to explain the increase in O 3 production with N 2 admixtures. The mechanism includes O 3 formation and destruction on the surfaces, adsorption and recombination of O and N, desorption of O 2 and N 2 , and NO x reactions. Without these reactions on the surface, the density of O 3 monotonically decreases with increasing N 2 admixture due to power absorption by N 2 leading to the formation of nitrogen oxides. With N-based surface chemistry, the concentrations of O 3 are maximum with a few tenths of percent of N 2 depending on the O 3 destruction probability on the surface. The consequences of the surface chemistry on ozone production are less than the effect of gas temperature without surface processes. An increase in the O 3 density with N-based surface chemistry occurs when the surface destruction probability of O 3 or the surface roughness was decreased.

54 ENVIRONMENTAL SCIENCES↗

The electronics and data acquisition system for the DarkSide-50 veto detectors

DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger system have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of shashlik electromagnetic calorimeter prototype for SoLID

A shashlik electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for Solenoidal large Intensity Device (SoLID) to measure the energy deposition of electrons and hadrons, and to provide particle identification after the energy of the accelerator was upgraded to 12 GeV. Tsinghua University is the member of Hall A collaboration in charge of development and production of the large shashlik electromagnetic calorimeter of SoLID. One module of that calorimeter is composed by 194 layers. Each layer consists of a 1.5 mm thick plastic scintillator put on top of a 0.5 mm thick lead plate. Scintillation light is read out by wave-length shifter fibers penetrating through the calorimeter modules longitudinally along the direction of flight of the impact particle. This paper describes the design and construction of that module, as well as a few optimization studies meant to improve its performance. A detailed Geant4 simulation also shows that an energy resolution of 5%/√ E (GeV) and a good containment for electromagnetic showers can be achieved, as well as some basic electron identification. In conclusion, a prototype of that module will be tested soon with an electron beam at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Increasing the efficiency of photon collection in LArTPCs: the ARAPUCA light trap

The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a crucial role in the event reconstruction as well as the time reference for non-beam physics such as supernovae neutrino detection and baryon number violation studies. Here in this contribution, we present the current R&D work on the ARAPUCA (Argon R&D Advanced Program at UNICAMP), a light trap device to enhance Ar scintillation light collection and thus the overall performance of LArTPCs. The ARAPUCA working principle is based on a suitable combination of dichroic filters and wavelength shifters to achieve a high efficiency in light collection. We discuss the operational principles, the last results of laboratory tests and the application of the ARAPUCA as the alternative photon detection system in the protoDUNE detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emanation and bulk fluorescence in liquid argon from tetraphenyl butadiene wavelength shifting coatings

Here, we study the stability of three types of popularly employed TPB coatings under immersion in liquid argon. TPB emanation from each coating is quantified by fluorescence assay of molecular sieve filter material after a prolonged soak time. Two of the coatings are shown to emanate a detectable concentration of TPB into argon over a 24 hour period, which corresponds to tens of parts per billion in argon by mass. In an independent setup, the dissolved or suspended TPB is shown to produce a wavelength shifting effect in the argon bulk. Interpretations of these results and implications for present and future liquid argon time projection chamber experiments are discussed.

Scintillators, scintillation and light emission pr↗

Radiation-hardness studies with cerium-doped fused-silica fibers

In this work, we describe our R&D effort to develop potentially radiation-hard scintillating and wavelength shifting fibers by doping fused-silica with cerium. The cerium-doped optical fibers with different core structures and concentrations were exposed to gamma radiation (60Co) at different dose rates up to 100 kGy. We evaluated the radiation-induced degradation in photoluminescence, optical transmission, and recovery phenomena in the wavelength range from 300 to 700 nm. We were able to model the experimental data based on second-order rate equations where the fit parameters that govern the damage profile were utilized to predict recovery. We also measured the influence of radiation on the numerical aperture. Finally, we offer some thoughts on the use of these types of fibers in particle and nuclear physics detectors.

36 MATERIALS SCIENCE↗

Neutrino identification with scintillation light in MicroBooNE

MicroBooNE is a neutrino experiment which employs a liquid argon (LAr) time projection chamber (TPC) to record neutrino interactions from Fermilab's neutrino beamlines. The experiment's primary objective is to study low-energy νe interactions from the Booster Neutrino Beamline (BNB). Located on the surface, the detector is affected by a continuous rate of cosmic-rays. This leads to one neutrino interaction for every 104 cosmic rays observed in the TPC, making it difficult to isolate neutrino interactions in the detector using charge alone. MicroBooNE's trigger makes use of prompt scintillation light and plays an essential role in both performing strong background rejection and significantly reducing data-rates. Furthermore, a series of novel techniques relying on scintillation light are used to isolate beam-induced activity. This document briefly presents MicroBooNE's scintillation-light based trigger and novel Flash-Matching pattern recognition techniques for cosmic-rejection. This work serves as the foundation of neutrino analyses in LArTPC detectors and is therefore of interest to the broader short- and long-baseline neutrino programs being launched at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The BDX detector prototype for dark matter searches in a Beam Dump eXperiment at JLAB

The Beam Dump eXperiment (BDX) is an electron-beam thick-target experiment aimed to investigate the existence of light dark matter particles in the MeV-GeV mass range at Jefferson Lab. A small-scale prototype (BDX-Proto) of the BDX detector has been constructed in order to validate the proposed design and to demonstrate with real measurements the capability to efficiently reject the cosmogenic backgrounds. Here we report the peformance of BDX-Proto extracted from a long campaign of cosmic ray measurements performed at INFN, Sez. Catania and INFN, LNS.

calorimeters↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

47 OTHER INSTRUMENTATION↗

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The 3×1×1 m3 demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performance of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Scintillator ageing of the T2K near detectors from 2010 to 2021

The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9–2.2% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator. The long component of the attenuation length of the wavelength shifting fibres was observed to degrade by 1.3–5.4% per year, while the short component of the attenuation length did not show any conclusive degradation.

47 OTHER INSTRUMENTATION↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

47 OTHER INSTRUMENTATION↗

Laser calibration of the ATLAS Tile Calorimeter during LHC Run 2

This article reports the laser calibration of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2 data campaign. The upgraded Laser II calibration system is described. The system was commissioned during the first LHC Long Shutdown, exhibiting a stability better than 0.8% for the laser light monitoring. The methods employed to derive the detector calibration factors with data from the laser calibration runs are also detailed. These allowed to correct for the response fluctuations of the 9852 photomultiplier tubes of the Tile Calorimeter with a total uncertainty of 0.5% plus a luminosity-dependent sub-dominant term. Finally, we report the regular monitoring and performance studies using laser events in both standalone runs and during proton collisions. These studies include channel timing and quality inspection, and photomultiplier linearity and response dependence on anode current.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The acrylic vessel for JSNS 2 -II neutrino target

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS 2 -II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. Here, the specifications, design, and measured properties of the acrylic vessel are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗