At least 865 records · Page 48

Modeling impacts of ice-nucleating particles from marine aerosols on mixed-phase orographic clouds during 2015 ACAPEX field campaign

Abstract. A large fraction of annual precipitation over the western United States comes from wintertime orographic clouds associated with atmospheric rivers (ARs). Transported African and Asian dust and marine aerosols from the Pacific Ocean may act as ice-nucleating particles (INPs) to affect cloud and precipitation properties over the region. Here we explored the effects of INPs from marine aerosols on orographic mixed-phase clouds and precipitation at different AR stages for an AR event observed during the 2015 ACAPEX field campaign under low dust (<0.02 cm−3) conditions. Simulations were conducted using the chemistry version of the Weather Research and Forecasting Model coupled with the spectral-bin microphysics at 1 km grid spacing, with ice nucleation connected with dust and marine aerosols. By comparing against airborne and ground-based observations, accounting for marine INP effects improves the simulation of AR-precipitation. The marine INPs enhance the formation of ice and snow, leading to less shallow warm clouds but more mixed-phase and deep clouds, as well as to a large spillover effect of precipitation after AR landfall. The responses of cloud and precipitation to marine INPs vary with the AR stages, with more significant effects before AR landfall and post-AR than after AR landfall, mainly because the moisture and temperature conditions change with the AR evolution. This work suggests weather and climate models need to consider the impacts of marine INPs since their contribution is notable under low dust conditions despite the much lower relative ice nucleation efficiency of marine INPs.

54 ENVIRONMENTAL SCIENCES↗

rustpix

rustpix is a high-performance, open-source Rust library with first-class Python bindings (via PyO3) for processing pixel-detector data in neutron imaging. It targets time-stamping detectors such as Timepix3 (TPX3) at ORNL's Spallation Neutron Source (VENUS beamline), where each detected neutron deposits charge across a cluster of pixels within a very high-rate event stream (96M+ hits/sec). rustpix parses TPX3 event data in parallel using memory-mapped I/O, offers four interchangeable clustering algorithms (ABS adjacency-based search, DBSCAN, graph/union-find connected components, and a parallel grid method), and extracts weighted, super-resolved centroids to produce neutron-event lists. A streaming architecture lets it process files larger than available memory. rustpix is distributed as a pip-installable Python package (with NumPy integration), Rust crates, a command-line tool, and an interactive GUI; it writes HDF5, Apache Arrow, and CSV; and it is designed to extend to TPX4 and other detector types. Released as open-source under the MIT License.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗

Impact of Increasing Distributed Wind Power and Wind Turbine Siting on Rural Distribution Feeder Voltage Profiles: Preprint

Many favorable wind energy resources in North America are located in remote locations without direct access to the transmission grid. Building transmission lines to connect remotely-located wind power plants to large load centers has become a barrier to increasing wind power penetration in North America. By connecting utility-sized megawatt-scale wind turbines to the distribution system, windpower supplied to consumers could be increased greatly. However, the impact of including megawatt-scale wind turbines on distribution feeders needs to be studied. The work presented here examined the impact that siting and power output of megawatt-scale wind turbines have on distribution feeder voltage. This is the start of work to present a general guide to megawatt-scale wind turbine impact onthe distribution feeder and finding the amount of wind power that can be added without adversely impacting the distribution feeder operation, reliability, and power quality.

17 WIND ENERGY↗

Modular inverter system

A system connected to an AC power grid having an AC phase signal includes an inverter module including a first inverter coupled to a DC voltage, actuated based on the AC phase signal. The first inverter provides a first voltage signal having predetermined harmonic components. A second inverter includes second switch elements coupled to the DC voltage and actuated by a second set of control signals phase delayed with respect to the first control signals. A transformer module has first and second primary windings coupled to the first and second inverters. The transformer module further includes a secondary winding coupled to first primary winding, the second primary winding, and the AC power grid. The secondary winding is configured to provide a secondary output voltage to the AC power grid by combining the first voltage signal and the second voltage signal such that the predetermined harmonic components are substantially cancelled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Apparatus and method for high density detachable electrical interface

The present disclosure relates to a high density electrical interconnect apparatus for interfacing with remotely located electrical components. The apparatus may have a housing, a substrate element supported within the housing, and a plurality of independent substrate interface connect subsystems arranged in a planar grid on the substrate element. The apparatus further has a plurality of independent electrical interface connector subassemblies, each configured to be coupled to an associated subplurality of the substrate interface connect subsystems, to form a plurality of electrical communication channels with the remotely located electrical components.

Patra, Susant↗

Investigating Short Circuit Models for Wind Turbine Generators

Short circuit study needs to be performed at the planning stage before connecting large gen erators with the electric grid. This study will reveal the impact of new generation on the fault levels of the grid. The fault levels will determine the rating of nearby equipment and setting of relays. However, a short circuit model of the new generation is required for this study. This report investigates and quantifies the short circuit models of different wind turbine generators (WTGs) and of wind farms, and using these models, explores the effects of the wind farms on the nearby switchgear. WTGs, commonly classified as Type 1, Type 2, Type 3, and Type 4, exhibit different short circuit behavior depending upon their architecture and controls. The short circuit model (synonymous to Thevenin model) of Type 1 WTG is well known; it comprises of a voltage source behind a transient reactance, X'. The transient reactance X' is derived using the reactance of stator, rotor and the magnetizing reactance. In case of Type 2 WTG, an external rotor resistance is used to increase the range of operating slips. The value of the external rotor resistance increases at higher operating slips. The effect of the external rotor resistance on the fault current response is analyzed by simulating a validated model of Type 2 WTG. The validation is performed using the field data from an actual 67-machine Type 2 wind farm located in Wyoming, USA. The results shows that the external rotor resistance should be considered in its Thevenin impedance for better accuracy. A wind farm contains a large number of WTGs, pad mounted transformers, and cables typically connected in a ‘daisy chain” configuration. The effect of these cable impedances on the short circuit model of Type 2 wind farm is examined using the validated models. It is found that the collector circuit cables inside the farm do not have a significant effect on the short circuit model of the farm. Based on this finding, a simple equivalencing procedure for the wind farm is proposed and validated. Faults inside and outside the wind farm are analyzed and recommendations to select main circuit breakers and generator circuit breakers are made. Type 3 WTG, also known as Doubly Fed Asynchronous Generator (DFAG), uses back to back converters in the rotor circuit to inject slip frequency voltage into the rotor circuit. Until recently, these machines used crowbar to short the rotor circuit during faults to protect the converter com ponents form high rotor currents resulting from faults. This type of WTG is simulated and the model is validated using field data from a 66-machine Type 3 wind farm in Wyoming, USA. The simulation study reveals that the crowbar feature is activated almost immediately after the fault takes place, and remains activated throughout the fault-period. This confirms that the short circuit model for Type 3 WTG with crowbar is similar to the model for Type 2 WTG. In the past, wind farms were allowed to disconnect during faults. However, recent grid codes around the world and in the United States demand that the wind farms be kept connected to the grid during faults, and provide certain reactive power quantified based on the voltage dip at the point of interconnection. This requirement, also called low voltage ride through (LVRT), can be accomplished by using Type 4 WTGs that employ full back to back converter interface between generators (permanent magnet synchronous generators are typically used) and the grid. However, the controls are proprietary, and hence the short circuit models are not well defined. This report proposes controls that enable the WTG to comply with the strictest grid codes, and based on this model, proposes a short circuit model of the Type 4 WTG. This model is not validated due to lack of validation data, but the use of grid code requirements as control objectives lends good credibility to the model. PSCAD/EMTDC ® , a powerful and time-tested time-domain simulation software is used to implement all models. This software is capable of modeling in detail all components of wind farms, and all components and controls of converters in time domain.

17 WIND ENERGY↗

Multi-modular power plant with dedicated electrical grid

A multi-modular power plant includes a plurality of on-site nuclear power modules that generate a power plant output, and a number of power plant systems which operate using electricity associated with a house load of the power plant. A switchyard associated with the power plant may electrically connect the power plant to a distributed electrical grid. The distributed electrical grid may be configured to service a plurality of geographically distributed consumers. Additionally, the switchyard may electrically connect the power plant to a dedicated electrical grid. The dedicated electrical grid may provide electricity generated from the power plant output to a dedicated service load, and the power plant output may be equal to or greater than a combined load of the dedicated service load and the house load. At least a portion of the power plant output may be distributed to both the power plant systems and the dedicated electrical grid.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Review of Strategies and Technologies for Demand-Side Management on Isolated Mini-Grids

This review provides an overview of strategies and currently available technologies used for demandside management (DSM) on mini-grids throughout the world. For the purposes of this review, mini-grids are defined as village-scale electricity distribution systems powered by small local generation sources and not connected to a main grid.1 Mini-grids range in size from less than 1 kW to several hundred kW of installed generation capacity and may utilize different generation technologies, such as micro-hydro, biomass gasification, solar, wind, diesel generators, or a hybrid combination of any of these. This review will primarily refer to AC mini-grids, though much of the discussion could apply to DC grids as well. Many mini-grids include energy storage, though some rely solely on real-time generation.

25 ENERGY STORAGE↗

Model Predictive Control of A Matrix-Converter Based Solid State Transformer for Utility Grid Interaction

The matrix converter solid state transformer (MC-SST), formed from the back-to-back connection of two three-to-single-phase matrix converters, is studied for use in the interconnection of two ac grids. The matrix converter topology provides a light weight and low volume single-stage bidirectional ac-ac power conversion without the need for a dc link. Thus, the lifetime limitations of dc-bus storage capacitors are avoided. However, space vector modulation of this type of MC-SST requires to compute vectors for each of the two MCs, which must be carefully coordinated to avoid commutation failure. An additional controller is also required to control power exchange between the two ac grids. In this paper, model predictive control (MPC) is proposed for an MC-SST connecting two different ac power grids. The proposed MPC predicts the circuit variables based on the discrete model of MC-SST system and the cost function is formulated so that the optimal switch vector for the next sample period is selected, thereby generating the required grid currents for the SST. Simulation and experimental studies are carried out to demonstrate the effectiveness and simplicity of the proposed MPC for such MC-SST-based grid interfacing systems.

Xue, Yaosuo↗

Design and Stability Analysis of Control System in Multiport Autonomous Reconfigurable Solar Power Plants (MARS)

The Multiport Autonomous Reconfigurable Solar Power Plant (MARS) is an integrated photovoltaic (PV) power generation and energy storage system (ESS), that is designed to connect to both alternating current (AC) transmission grids and high-voltage direct current (HVDC) links. It is a three-phase plant consisting of numerous components with a complex hardware and hierarchical control architecture. This paper presents an approach to decouple the multivariable system of MARS using a recursive reduced-order and boundary layer system methodology. This approach enables efficient computation of the control parameters for the Ll, L2, and L3 controllers. To validate the effectiveness of the proposed control strategy, cyclic tests in accordance with pre-defined performance criteria using controller Hardware-in-the-Loop (cHIL) experiments are conducted. The results demonstrate that the MARS system operates consistently under steady-state conditions. Furthermore, the dynamic response of the MARS system to various grid events is analyzed, underlining the resilience of MARS in presence of faults or loss of generation within the connected WECC system.

Xia, Qian↗

Optimal Discrete Net-Load Balancing in Smart Grids with High PV Penetration

Mitigating supply-demand mismatch is essential for smooth power grid operation. Traditionally, load curtailment techniques such as demand response have been used for this purpose. However, these cannot be the only component of a net-load balancing framework for smart grids with high PV penetration. These grids sometimes exhibit supply surplus, causing overvoltages. Currently, these are mitigated using voltage manipulation techniques such as Volt-Var Optimizations, which are computationally expensive, thereby increasing the complexity of grid operations. Taking advantage of recent technological developments that enable rapid selective connection of PV modules of an installation to the grid, we develop a unified net-load balancing framework that performs both load and solar curtailment. We demonstrate that when the available curtailment values are discrete, this problem is NP-hard and we develop bounded approximation algorithms. Our algorithms produce fast solutions, given the tight timing constraints required for grid operation, while ensuring that practical constraints such as fairness, network capacity limits, and so forth are satisfied. We also develop an online algorithm that performs net-load balancing using only data available for the current interval. Using both theoretical analysis and practical evaluations, we show that our net-load balancing algorithms provide solutions that are close to optimal in a small amount of time.

14 SOLAR ENERGY↗

A distributed decision framework for building clusters with different heterogeneity settings

In the past few decades, extensive research has been conducted to develop operation and control strategy for smart buildings with the purpose of reducing energy consumption. Besides studying on single building, it is envisioned that the next generation buildings can freely connect with one another to share energy and exchange information in the context of smart grid. It was demonstrated that a network of connected buildings (aka building clusters) can significantly reduce primary energy consumption, improve environmental sustainability and building s resilience capability. However, an analytic tool to determine which type of buildings should form a cluster and what is the impact of building clusters heterogeneity based on energy profile to the energy performance of building clusters is missing. To bridge these research gaps, we propose a self-organizing map clustering algorithm to divide multiple buildings to different clusters based on their energy profiles, and a homogeneity index to evaluate the heterogeneity of different building clusters configurations. In addition, a bi-level distributed decision model is developed to study the energy sharing in the building clusters. To demonstrate the effectiveness of the proposed clustering algorithm and decision model, we employ a dataset including monthly energy consumption data for 30 buildings where the data is collected every 15 min. It is demonstrated that the proposed decision model can achieve at least 13% cost savings for building clusters. Furthermore, the results show that the heterogeneity of energy profile is an important factor to select battery and renewable energy source for building clusters, and the shared battery and renewable energy are preferred for more heterogeneous building clusters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, Control, and Protection of a 13.2 kV, 1 MVA Solid State Transformer for Electric Vehicle Extreme Fast Charging Station

In this article, a medium-voltage (MV) ac-dc solid state transformer (SST) for electric vehicle (EV) extreme fast charging (XFC) station is proposed. The SST adopts a cascaded H-bridge (CHB)-based structure where the active front end (AFE) power stages are connected in input-series followed by dual active bridge (DAB) converters connected in an output-parallel configuration providing galvanic isolation through a high-frequency transformer (HFT). The SST is rated for 1 MVA and connects directly to a three-phase 13.2 kV MV ac grid through ac switchgear and outputs 750-V dc. At the dc bus, several dc/dc converters are connected, each of which can charge an EV based on its battery capacity. A novel decentralized control architecture of the SST is adopted in this work which simplifies the MV dc link voltage and module-level power balancing. In addition, the local and central protection designs of the SST are presented which identify and respond to the internal fault of the system. Finally, the experimental validations of the SST hardware prototype are presented up to the rated voltage. Furthermore, this article details the design and implementation of the MV SST addressing the challenges of an isolated MV class power converter for connecting directly to the MV ac grid with unique controller architecture, distributed protection framework, and SST constructional features.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Artificial Intelligence for a Resilient and Flexible Power Grid

Recent widespread and extreme natural disasters as well as the drive towards clean sustainable energy sources necessitate a transformational operational and technological approaches to improve power grid resilience. Convergence of artificial intelligence (AI), distributed computing, and connectivity technologies enables these new approaches to deliver a sustainable electric grid. In particular, AI-based techniques can enable proactive decision-making by processing massive amounts of data to deliver intelligence at various levels of the system, edge devices to control room. In this chapter, we will explore the potential applications AI-based technology will unlock and challenges to address to achieve a sustainable, flexible power grid.

Omitaomu, Femi↗

MaDEVIoT: Cyberattacks on EV Charging Can Disrupt Power Grid Operation

Extensive roll-out of electric vehicles (EVs) requires large-scale deployment of high-power EV Charging Stations (EVCSs). EVCSs are connected to the internet using Internetof- Things (IoT) such as smartphones, to improve the charging experience of users and increase their profitability. This paper studies the feasibility of demand-side cyberattacks launched on power grids via such internet-connected highpower EVCSs. The attack mechanism distorts power grid frequency and voltage, and has the potential to trigger systemwide outages. The case study, based on the power grid and EV deployment plans in Manhattan, New York, illustrates potential impacts of such attacks. The results show that such attacks will become feasible in Manhattan, New York in 2030, as EV adoption increases. Furthermore, the attacks in 2030 are feasible even compromising a single company’s EVCS server in Manhattan, New York. The attacks can cause line overloads and trip over-frequency protection relays, causing system-side blackout in the power grid in Manhattan, New York. The paper informs planning authorities and power grid operators involved with the roll-out of EV charging infrastructure about potential cyberthreats to power grids via manipulating internet-connected high-power EVCSs.

Acharya, Samrat S.↗

Frequency Response and Congestion Management using Multi-Terminal HVDC Overlay

Continental level power system interconnections using a High Voltage direct current (HVDC) transmission lines have been considered to bring economic benefits such as interregional power exchange. This paper describes the modeling process and studies the technical benefits of having multiple HVDC lines, including a grid of HVDC lines (macrogrid) configuration, connecting the North American Eastern and Western electric power interconnections. The models developed provide steady state and stability analysis for multiple HVDC overlay topologies and provide technical benefit analysis in terms of frequency response and congestions management. The paper also provides a comparison of different HVDC topologies performance and their grid support in case of major disturbances

Tbaileh, Ahmad↗

TidGen Power System Commercialization Project

ORPC Maine, LLC, a wholly-owned subsidiary of Ocean Renewable Power Company, LLC (collectively ORPC), submits this Final Technical Report for the TidGen® Power System Commercialization Project (Project), partially funded by the U.S. Department of Energy (DE-EE0003647). The Project was built and operated in compliance with the Federal Energy Regulatory Commission (FERC) pilot project license (P-12711) and other permits and approvals needed for the Project. This report documents the methodologies, activities and results of the various phases of the Project, including design, engineering, procurement, assembly, installation, operation, licensing, environmental monitoring, retrieval, maintenance and repair. The Project represents a significant achievement for the renewable energy portfolio of the U.S. in general, and for the U.S. marine hydrokinetic (MHK) industry in particular. The stated Project goal was to advance, demonstrate and accelerate deployment and commercialization of ORPC’s tidal-current based hydrokinetic power generation system, including the energy extraction and conversion technology, associated power electronics, and interconnection equipment capable of reliably delivering electricity to the domestic power grid. ORPC achieved this goal by designing, building and operating the TidGen® Power System in 2012 and becoming the first federally licensed hydrokinetic tidal energy project to deliver electricity to a power grid under a power purchase agreement in North America. Located in Cobscook Bay between Eastport and Lubec, Maine, the TidGen® Power System was connected to the Bangor Hydro Electric utility grid at an on-shore station in North Lubec on September 13, 2012. ORPC obtained a FERC pilot project license for the Project on February 12, 2012 and the first Maine Department of Environmental Protection General Permit issued for a tidal energy project on January 31, 2012. In addition, ORPC entered into a 20-year agreement with Bangor Hydro Electric Company on January 1, 2013 for up to 5 megawatts at a price of $215/MWh, escalating at 2.0% per year.

16 TIDAL AND WAVE POWER↗

FREQUENCY REGULATION WITH CONNECTED LIGHTING SYSTEMS

The management of end-use energy resources, e.g., commercial buildings, has been investigated as a promising source of services for the electric power grid. Lighting consumes about 17% electricity of U.S. commercial buildings; however, it may contribute significantly to services that improve the reliability and resilience of the grid due to its rapid speed of response. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change their power demand more quickly than most other building electricity end uses. But the potential of CLS to provide grid services has not been considerably investigated. In this paper, we describe initial research to evaluate the potential of CLS for the grid service of frequency regulation. Frequency regulation is a reliability product that corrects in a matter of seconds for short-term changes in the balance between supply and demand in the balancing area that might affect the stability of the power system. Frequency regulation signals for a medium office building are generated from the normalized test signals for the PJM Interconnection Reg-A and Reg-D regulations services. Control of the CLS locally to follow the Reg-A or Reg-D signal is used to provide contributions to the corresponding frequency regulation service. The performance of CLS for frequency regulation is evaluated using the PJM 40-Minute Performance Score Template. The performance scores obtained for all CLS categories for both Reg-A and Reg-D signals far exceed the minimum score for the qualification, a very promising result for CLS to provide frequency regulation service.

Wang, Peng↗