At least 865 records · Page 48

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance characteristics and output power stability of a multichannel fibre laser

The effect of the density and number of spectral channels on the output power stability in a multichannel cw laser has been studied theoretically and experimentally. In our calculations, we used a model in which the interaction between channels due to gain medium saturation was determined by channel frequency spacing-dependent cross-saturation coefficients. The key features of lasing have been analysed and illustrated by the examples of three-, five- and nine-channel lasers. It has been shown that, at a given excess of the pump power over threshold, the channel powers can be equalised by introducing additional losses into the highest power channels. At a sufficiently high channel density, raising the pump power then leads to termination of lasing in the even channels. As the number of channels increases, the laser system retains its stability, but the time needed for the transition to a steady state increases sharply. In our experiments, we used an erbium-doped fibre laser whose design ensured independent control over the powers of up to 40 spectral channels anchored on the telecommunication frequency grid. Our experimental data are in qualitative agreement with the calculation results. In particular, a long-term relative instability less than 3 dB was only observed at a number of channels less than seven and channel frequency spacings above 400 GHz. Instability was shown to increase with an increase in the number and density of channels. (control of laser radiation parameters)

42 ENGINEERING↗

Parameterization in Grid Generation

The distribution of grid points for calculating the solution of partial differential equations is chosen so as to include consideration of truncation error, stability, and the resolution of the solution near boundary layers and shocks. It is important to specify the distribution of points along a grid line. The problem of distributing points along a curve is considered. It is assumed that the curve is defined parametrically. The objective is to select a set of parameter values so that the corresponding points on the curves are properly distributed. The distribution is based on some intrinsic property of the curve such as arc length or curvature.

Mastin, C. W.↗

Large time-step stability of explicit one-dimensional advection schemes

There is a wide-spread belief that most explicit one-dimensional advection schemes need to satisfy the so-called 'CFL condition' - that the Courant number, c = udelta(t)/delta(x), must be less than or equal to one, for stability in the von Neumann sense. This puts severe limitations on the time-step in high-speed, fine-grid calculations and is an impetus for the development of implicit schemes, which often require less restrictive time-step conditions for stability, but are more expensive per time-step. However, it turns out that, at least in one dimension, if explicit schemes are formulated in a consistent flux-based conservative finite-volume form, von Neumann stability analysis does not place any restriction on the allowable Courant number. Any explicit scheme that is stable for c is less than 1, with a complex amplitude ratio, G(c), can be easily extended to arbitrarily large c. The complex amplitude ratio is then given by exp(- (Iota)(Nu)(Theta)) G(delta(c)), where N is the integer part of c, and delta(c) = c - N (less than 1); this is clearly stable. The CFL condition is, in fact, not a stability condition at all, but, rather, a 'range restriction' on the 'pieces' in a piece-wise polynomial interpolation. When a global view is taken of the interpolation, the need for a CFL condition evaporates. A number of well-known explicit advection schemes are considered and thus extended to large delta(t). The analysis also includes a simple interpretation of (large delta(t)) total-variation-diminishing (TVD) constraints.

Leonard, B. P.↗

Voltage Probability Density Function Shaping Control Strategy Considering Grid Operational Uncertainties

It is well-known that power systems operation always affected by various uncertainties which make the bus voltage a random process that can be characterized by its probability density function (PDF) at any time instant. In this context, this paper presents a novel PDF-based voltage control framework for power systems. By modeling voltage as a stochastic process, we formulate a stochastic differential equationthat captures grid uncertainties. The associated Fokker-Planck-Kolmogorov equation is derived to describe the evolution of the voltage PDF, which enables the formulation of a PDF-shaping control strategy. To simplify the PDF control formulation, a B-spline neural network is introduced for real-time estimation and regulation of the voltage distribution. The proposed PDF control law updates voltage references for energy storage systems and synchronous generators using real-time PDF measurements and feedback signals. The proposed method is validated on a modified Kundur’s two-area system. Simulation results demonstrate that the controller can significantly improve the voltage stability under stochastic conditions, highlighting its effectiveness in modern inverter-rich grids.

Gui, Yonghao [ORNL] (ORCID:0000000250435534)↗

Understanding Aqueous Electrolyte Stability through Combined Computational and Magnetic Resonance Spectroscopy: A Case Study on Vanadium Redox Flow Battery Electrolytes

Redox flow battery (RFB) is a promising candidate for energy storage component in designing resilient grid scale power supply due to the advantage of the separation of power and energy. However, poorly understood chemical and thermal stability issues of electrolytes currently limit the performance of RFB. Designing of high performance stable electrolytes requires comprehensive knowledge about the molecular level solvation structure and dynamics of their redox active species. The molecular level understanding of detrimental V2O5 precipitation process led to successful designing of mixed acid based electrolytes for vanadium redox flow batteries (VRFB). The higher stability of mixed acid based electrolytes is attributed to the choice of hydrochloric acid as optimal co-solvent, which provides chloride anions for ligand exchange process in vanadium solvation structure. The role of chloride counter anion on solvation structure and dynamics of vanadium species were studied using combined magnetic resonance spectroscopy and DFT based theoretical methods. Finally, the solvation phenomenon of multiple vanadium species and their impact on VRFB electrolyte chemical stability were discussed.

Comprehensive Solvation Chemistry↗

HVDC Macrogrid Modeling for Power-flow and Transient Stability Studies in North American Continental-Level Interconnections

High Voltage Direct Current (HVDC) transmission lines are being constructed throughout the world, aided by advancements in power electronics and the potential value to transfer power between distant areas and off-shore locations. Multiple HVDC lines within and across large AC interconnections could bring about economic benefits such as interregional capacity exchange, and transfer of low-cost, distant electric energy directly to load centers. In addition, network configuration of HVDC lines could result in additional benefits that have not been deeply studied. This paper describes the modeling process for continental-level power system interconnections with the addition of multiple HVDC lines configured as a macrogrid. The models used for study are based on industry-accepted power-flow and dynamic system models for the North American Eastern and Western Interconnections. The model provides insight on feasibility and initial steady-state and stability tests of the HVDC macrogrid and its interactions with the existing electricity infrastructure, opening the door to analysis of the technical value of such a macrogrid.

HVDC transmission, North American Power Grids, AC ↗

Linear stability of streamwise developing longitudinal vortices

The linear stability of numerical solutions to the quasicylindrical equations of motion for swirling flows is investigated. Initial conditions are derived from Batchelor's similarity solution for a trailing line vortex. The stability calculations are performed using a 2nd-order accurate finitedifference scheme on a staggered grid with the accuracy of the computed eigenvalues enhanced through Richardson extrapolation. The streamwise development of both viscous and inviscid instability modes is discussed for low and high swirl cases. The effect of adverse and favorable pressure gradients on the viscous stability of a longitudinal vortex is also investigated.

Spall, Robert E.↗

Sensitivity of Western U.S. power system dynamics to droughts compounded with fuel price variability

The energy sector is heavily dependent on surface water availability for reliable electricity generation. Power system operations are usually evaluated through system reliability and economic perspectives, with assumptions based on market prices and normal water availability. As natural gas technologies continue to dominate new thermal capacity, replacing retiring coal and nuclear generators, natural gas price stability becomes increasingly important and the impact of price volatility on grid operations must be understood. Here, we explore the range of Western Electricity Coordinating Council (WECC) regional power operations, which represents the electric interconnection over the western half of the continental United States, using a production cost model driven by different fuel prices and an integrated hydrology model to simulate historical water availability. Our results show system-wide operation costs increasing in drought years or when gas prices increase, as expected. In addition, we found those system-wide increases can be of the same magnitude. Regional analysis of the responses to compounded droughts and price volatility highlight differences in magnitude and direction depending on regional generation technology portfolios. The Pacific Northwest is most sensitive to drought conditions, Southern California is most sensitive to gas prices, and the Desert Southwest is sensitive to both with the same magnitude. This analysis motivates further research in combined hydrology and power system modeling to characterize regional dynamics and associated uncertainties across scales, which is an important underpinning for the development of more resilient energy and water systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Models and methods for assessing the value of HVDC and MVDC technologies in modern power grids

This report reflects the results of U.S. Department of Energy’s (DOE) Grid Modernization project 0074 “Models and methods for assessing the value of HVDC [high-voltage direct current] and MTDC [multi-terminal direct current] technologies in modern power grids.” The work was done by the Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) in cooperation with Mid-Continent Independent System Operator (MISO) and Siemens. The main motivation of this study was to show the benefit of using direct current (DC) systems larger than those in existence today as they overlap with the alternating current (AC) systems. Proper use of their flexibility in terms of active/reactive power control and fast response can provide much-needed services to the grid at the same time as moving large blocks of energy to take advantage of cost diversity. Ultimately, the project’s success will enable decision-makers and investors to make well-informed decisions regarding this use of DC systems. This project showed the technical feasibility of HVDC macrogrid for frequency control and congestion relief in addition to bulk power transfers. Industry-established models for commonly used technologies were employed, along with high-fidelity models for recently developed HVDC converter technologies; like the modular multilevel converters (MMCs), a voltage source converters (VSC). Models for General Electric Positive Sequence Load Flow (GE PSLF) and Siemens Power System Simulator (PSS/E), widely used analysis programs, were for the first time adapted to include at the same time both Western Electricity Coordinating Council (WECC) and Eastern Interconnection (EI), the two largest North American interconnections. The high-fidelity models and their control were developed in detail for MMC system and extended to HVDC systems in point-to-point and in three-node multi-terminal configurations. Using a continental-level mixed AC-DC grid model, and using a HVDC macrogrid power flow and transient stability model, the results showed that the HVDC macrogrid relieved congestion and mitigated loop flows in AC networks, and provided up to 24% improvement in frequency responses. These are realistic studies, based on the 2025 heavy summer and EI multi-regional modeling working group (MMWG) 2026 summer peak cases. This work developed high-fidelity models and simulation algorithms to understand the dynamics of MMC. The developed models and simulation algorithms are up to 25 times faster than the existing algorithms. Models and control algorithms for high-fidelity models were designed and tested for point-to-point and multi-terminal configurations. The multi-terminal configuration was tested connecting simplified models of EI, WI, and Electric Reliability Council of Texas (ERCOT). The developed models showed up to 45% improvement in frequency response with the connection of all the three asynchronous interconnections in the United States using fast and advanced DC technologies like the multi-terminal MMC-DC system. Future work will look into developing high-fidelity models of other advanced DC technologies, combining high-fidelity models with the continental-level model, incorporating additional services. More scenarios involving large-scale HVDC and MTDC will be evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Resolution Numerical Simulation Of Shock Waves

NASA technical memorandum compares results of upwind and symmetric shock-capturing methods in numerical simulation of gas-dynamic flows. Both methods find shocks as sharp variations in fluid properties over few grid points. Methods differ in type of artificial viscosity introduced to stabilize computations. Symmetric method shown as accurate as upwind method, but with fewer and simpler time steps in transient case or fewer iteration steps in steady-state case.

Yee, H. C.↗

Application of p-Multigrid to Discontinuous Galerkin Formulations of the Poisson Equation

We investigate p-multigrid as a solution method for several different discontinuous Galerkin (DG) formulations of the Poisson equation. Different combinations of relaxation schemes and basis sets have been combined with the DG formulations to find the best performing combination. The damping factors of the schemes have been determined using Fourier analysis for both one and two-dimensional problems. One important finding is that when using DG formulations, the standard approach of forming the coarse p matrices separately for each level of multigrid is often unstable. To ensure stability the coarse p matrices must be constructed from the fine grid matrices using algebraic multigrid techniques. Of the relaxation schemes, we find that the combination of Jacobi relaxation with the spectral element basis is fairly effective. The results using this combination are p sensitive in both one and two dimensions, but reasonable convergence rates can still be achieved for moderate values of p and isotropic meshes. A competitive alternative is a block Gauss-Seidel relaxation. This actually out performs a more expensive line relaxation when the mesh is isotropic. When the mesh becomes highly anisotropic, the implicit line method and the Gauss-Seidel implicit line method are the only effective schemes. Adding the Gauss-Seidel terms to the implicit line method gives a significant improvement over the line relaxation method.

Helenbrook, B. T.↗

An Optimal-Estimation-Based Aerosol Retrieval Algorithm Using OMI Near-UV Observations

An optimal-estimation(OE)-based aerosol retrieval algorithm using the OMI (Ozone Monitoring Instrument) near-ultraviolet observation was developed in this study. The OE-based algorithm has the merit of providing useful estimates of errors simultaneously with the inversion products. Furthermore, instead of using the traditional lookup tables for inversion, it performs online radiative transfer calculations with the VLIDORT (linearized pseudo-spherical vector discrete ordinate radiative transfer code) to eliminate interpolation errors and improve stability. The measurements and inversion products of the Distributed Regional Aerosol Gridded Observation Network campaign in northeast Asia (DRAGON NE-Asia 2012) were used to validate the retrieved aerosol optical thickness (AOT) and single scattering albedo (SSA). The retrieved AOT and SSA at 388 nm have a correlation with the Aerosol Robotic Network (AERONET) products that is comparable to or better than the correlation with the operational product during the campaign. The OEbased estimated error represented the variance of actual biases of AOT at 388 nm between the retrieval and AERONET measurements better than the operational error estimates. The forward model parameter errors were analyzed separately for both AOT and SSA retrievals. The surface reflectance at 388 nm, the imaginary part of the refractive index at 354 nm, and the number fine-mode fraction (FMF) were found to be the most important parameters affecting the retrieval accuracy of AOT, while FMF was the most important parameter for the SSA retrieval. The additional information provided with the retrievals, including the estimated error and degrees of freedom, is expected to be valuable for relevant studies. Detailed advantages of using the OE method were described and discussed in this paper.

Air Pollution↗

Distributed hierarchical control architecture for integrating smart grid assets during normal and disrupted operations

Disclosed herein are representative embodiments of methods, apparatus, and systems for facilitating operation and control of a resource distribution system (such as a power grid). Among the disclosed embodiments is a distributed hierarchical control architecture (DHCA) that enables smart grid assets to effectively contribute to grid operations in a controllable manner, while helping to ensure system stability and equitably rewarding their contribution. Embodiments of the disclosed architecture can help unify the dispatch of these resources to provide both market-based and balancing services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Water Start Up Time Model Validation Test

This report is an Oregon Institute of Technology thesis project completed in partial fulfillment for the Masters of Science in Renewable Energy Engineering degree. The testing and research done for this report, investigate the phenomena of water start up time in the spiral case of hydro units. Water start up time is defined as the time it takes for water to accelerate from zero to rated velocity. From analysis of the literature there shows no published article of water start up time being measured and compared to theoretically calculated values. However a multiplier is used to create a buffer in the estimations of water start up time to use in the engineering and selection of governors for hydro units. The multiplier has also been widely used in computer model simulations which causes a dependence of this multiplier. In 2013 an article was published which challenges the hypothesis that water start up time has been over hypothesized and that the multiplier would be of a smaller value than what was hypothesized which would mean that the governing ability is more than what was expected. This proposal of a higher governing ability would mean that the hydro facilities that are currently standing has a higher stability rating than what was initially thought. The higher stability would allow for increased penetration of renewables onto the electrical grid. The lack of actual water start up time measurements as well as the infeasibility of testing on an actual hydro unit meant that a model would need to be designed, built, and tested. The model had two testing parameters that were examined. One of the parameters was flow rate that was controlled by the number of wicket gates that was installed into the system and the other was the reference height from the forebay to tail water. There were one hundred results from the test trials. The data from the trials showed a trend for the multiplier which was not constant as previously hypothesized and instead illustrated a parabolic trend that tapers into a linear digression. This result means that the range of testing was insufficient and the height range in which the trials were taking placed was subjected to higher variability. The results showed that the multiplier used in water start up time is not a constant and is variable based on the water level. The previous hypothesis stating that the water start up time is faster is false. In accordance with the results the trend showed that the actual water start up time is slower than what is hypothesized. This means at lower water levels the hypothesized governing ability is actually less than what is calculated to be using the current method of water start up time calculation for spiral cases. The theoretical analysis showed that with increased water level and flow rate showed that the multiplier has less effect on water start up time. The value of the water start up time tapering off from the experimental data shows that the trend for water start up time for both theoretical and experimental share similarities. An increased testing range of the water level in the trials will hypothetically lower the variability of the multiplier and in turn conform to a linear equation. The linear equation is shown to approach zero with increased head in which a static value can be achieved for a specified range.

13 HYDRO ENERGY↗

Numerical stability of an explicit finite difference scheme for the solution of transient conduction in composite media

A theoretical evaluation of the stability of an explicit finite difference solution of the transient temperature field in a composite medium is presented. The grid points of the field are assumed uniformly spaced, and media interfaces are either vertical or horizontal and pass through grid points. In addition, perfect contact between different media (infinite interfacial conductance) is assumed. A finite difference form of the conduction equation is not valid at media interfaces; therefore, heat balance forms are derived. These equations were subjected to stability analysis, and a computer graphics code was developed that permitted determination of a maximum time step for a given grid spacing.

Campbell, W.↗

Aeroelastic Stability Computations for Turbomachinery

This paper describes an aeroelastic analysis program for turbomachines. Unsteady Navier-Stokes equations are solved on dynamically deforming, body fitted, grid to obtain the aeroelastic characteristics. Blade structural response is modeled using a modal representation of the blade and the work-per-cycle method is used to evaluate the stability characteristics. Nonzero interblade phase angle is modeled using phase-lagged boundary conditions. Results obtained showed good correlation with existing experimental, analytical, and numerical results. Numerical analysis also showed that given the computational resources available today, engineering solutions with good accuracy are possible using higher fidelity analyses.

Srivastava, R.↗

Consensus-Based Control and Optimization of Power System Inertia

The integration of distributed energy resources (DERs), such as solar, wind, and energy storage systems, into power grids through inverter-based resources reduces power system inertia, leading to faster frequency dynamics and potential grid instability. To address this challenge, this paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources (synchronous generators and/or DERs) during system disturbances, enhancing both system stability and economic performance. The distributed control and optimization approach assumes each inertia source exchanges information solely with its neighbor ones, making it easily scalable to large power grid networks. The impacts of the communication connectivity among the inertia sources as well as their generation capacity limits on the distributed approach are investigated. We also demonstrate the approach’s robustness in scenarios involving communication time delays and packet losses, validating its effectiveness through numerical simulations on a 4-bus test system and a two-area 8-bus test system.

Power system inertia↗