At least 865 records · Page 48

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.↗

Global Monitoring of Air Pollution Using Spaceborne Sensors

The MODIS sensor onboard EOS-Terra satellite provides not only daily global coverage but also high spectral (36 channels from 0.41 to 14 microns wavelength) and spatial (250m, 500m and 1km) resolution measurements. A similar MODIS instrument will be also configured into EOS-Aqua satellite to be launched soon. Using the complementary EOS-Terra and EOS-Aqua sun-synchronous orbits (10:30 AM and 1:30 PM equator-crossing time respectively), it enables us also to study the diurnal changes of the Earth system. It is unprecedented for the derivation of aerosol properties with such high spatial resolution and daily global converge. Aerosol optical depth and other aerosol properties, e.g., Angstrom coefficient over land and particle size over ocean, are derived as standard products at a spatial resolution of 10 x 10 sq km. The high resolution results are found surprisingly useful in detecting aerosols in both urban and rural regions as a result of urban/industrial pollution and biomass burning. For long-lived aerosols, the ability to monitoring the evolution of these aerosol events could help us to establish an system of air quality especially for highly populated areas. Aerosol scenarios with city pollution and biomass burning will be presented. Also presented are the method used in the derivation of aerosol optical properties and preliminary results will be presented, and issue as well as obstacles in validating aerosol optical depth with AERONET ground-based observations.

Chu, D. A.↗

Development of achromatic paraboloidal mirror lenses with 100 nm focus

The Fast-Track project goals are to ultimately develop an axially symmetric, achromatic paraboloidal mirror lens with a 100-nanometer focus. The optic will provide large numerical aperture, high efficiency, and high resolution, and will be a higher throughput, cost-effective alternative to conventional x-ray optics such as Kirkpatrick Baez mirrors for synchrotron beamline development and upgrades.

43 PARTICLE ACCELERATORS↗

NGC 2024: Multi-wavelength Infrared and Radio Observations

A series of far-infrared maps obtained on the KAO find the total IR luminosity of NGC 2024 is to the 4th power L, and show a peak in flux density and optical depth about 1' south of IRS 2. High resolution spectra of IRS 2 in Brackett alfa and Pfund gamma indicate the presence of an optically thick wind with M approx. 7 x 10 to the minus 7 power M sub yr to minus 1 power, from which we infer that IRS 2 is unable to supply the luminosity observed. A six centimeter continuum map peaks near the location of the far-infrared peak and confirms it as a likely site for a source to provide this luminosity. Maps in HCN, CS, and H2CO show the gas is dense in the direction of the far IR peak. Velocity analysis shows the H2 region created by the far IR source and IRS 2 forms an expanding bubble in front of which the H2CO is seen in absorption, and which is bounded in the south and behind by dense material.

Smith, H. A.↗

High resolution color band pyrometer ratioing

The sensing head of a two-color band ratioing pyrometer of a known type using a fiber optic cable to couple radiation to dual detector photodiodes is improved to have high spatial resolution by focusing the radiation received through an objective lens (i.e., by focusing the image of a target area) onto an opaque sheet spaced in front of the input end of the fiber optic cable. A two-mil hole in that sheet then passes radiation to the input end of the cable. The detector has two channels, one for each color band, with an electronic-chopper stabilized current amplifier as the input stage followed by an electronic-chopper stabilized voltage amplifier.

Bickler, Donald B.↗

THE KAPTEYN MOVING GROUP IS NOT TIDAL DEBRIS FROM ω CENTAURI

The Kapteyn moving group has been postulated as tidal debris from ω Centauri. If true, members of the group should show some of the chemical abundance patterns known for stars in the cluster. We present an optical and near-infrared high-resolution, high-signal-to-noise ratio spectroscopic study of 14 stars of the Kapteyn group, plus 10 additional stars (the ω Cen group) that, while not listed as members of the Kapteyn group as originally defined, have nevertheless been associated dynamically with ω Centauri. Abundances for Na, O, Mg, Al, Ca, and Ba were derived from the optical spectra, while the strength of the chromospheric He i 10830 Å line is studied as a possible helium abundance indicator. The resulting Na–O and Mg–Al patterns for stars of the combined Kapteyn and ω Cen group samples do not resemble those of ω Centauri, and are not different from those of field stars of the Galactic halo. The distribution of equivalent widths of the He i 10830 Å line is consistent with that found among non-active field stars. Therefore, no evidence is found for second-generation stars within our samples, which most likely rules out a globular-cluster origin. Moreover, no hint of the unique barium overabundance at the metal-rich end, well established for ω Centauri stars, is seen among stars of the combined samples. Because this specific Ba pattern is present in ω Centauri irrespective of stellar generation, this would rule out the possibility that our entire sample might be composed of only first-generation stars from the cluster. Finally, for the stars of the Kapteyn group, the possibility of an origin in the hypothetical parent galaxy of ω Centauri is disfavored by the different run of α-elements with metallicity between our targets and stars from present-day dwarf galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra-short longitudinal spatial coherence length of laser light with the combined effect of spatial, angular, and temporal diversity

We demonstrate ultra-high axial-resolution topography and tomography of multilayered objects using pseudo thermal light source, i.e., laser. The longitudinal spatial coherence (LSC) length of light was significantly reduced by synthesizing a pseudo thermal source with the combined effect of spatial, angular, and temporal diversity. Thus, generating a low spatially coherent (i.e., broad angular frequency spectrum) light source having narrow temporal frequency spectrum. The LSC length was reduced less than 10 μm using a very low magnification lens. Experimental results of optical sectioning of multilayer objects with high axial-resolution of the order of 4 μm was achieved which is comparable to broadband light source. The present system does not require any dispersion compensation optical system for biological samples as a highly monochromatic light source is used.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Global to Microscale Evolution of the Pinatubo Volcanic Aerosol Derived from Diverse Measurements and Analyses

We assemble data on the Pinatubo aerosol from space, air, and ground measurements, develop a composite picture, and assess the consistency and uncertainties of measurement and retrieval techniques. Satellite infrared spectroscopy, particle morphology, and evaporation temperature measurements agree with theoretical calculations in showing a dominant composition of H2SO4-H20 mixture, with H2SO4 weight fraction of 65-80% for most stratospheric temperatures and humidities. Important exceptions are (1) volcanic ash, present at all heights initially and just above the tropopause until at least March 1992, and (2) much smaller H2SO4 fractions at the low temperatures of high-latitude winters and the tropical tropopause. Laboratory spectroscopy and calculations yield wavelength- and temperature-dependent refractive indices for the H2SO4-H20 droplets. These permit derivation of particle size information from measured optical depth spectra, for comparison to impactor and optical-counter measurements. All three techniques paint a generally consistent picture of the evolution of R(sub eff), the effective radius. In the first month after the eruption, although particle numbers increased greatly, R(sub eff) outside the tropical core was similar to preeruption values of approx. 0.1 to 0.2 microns, because numbers of both small (r < 0.2 microns) and large (r > 0.6 microns) particles increased. In the next 3-6 months, extracore R(sub eff) increased to approx. 0.5 microns, reflecting particle growth through condensation and coagulation. Most data show that R(sub eff) continued to increase for about 1 year after the eruption. R(sub eff) values up to 0.6 - 0.8 microns or more are consistent with 0.38 - 1 micron optical depth spectra in middle to late 1992 and even later. However, in this period, values from in situ measurements are somewhat less. The difference might reflect in situ undersampling of the very few largest particles, insensitivity of optical depth spectra to the smallest particles, or the inability of flat spectra to place an upper limit on particle size. Optical depth spectra extending to wavelengths lambda > 1 micron are required to better constrain R(sub eff), especially for R(sub eff) > 0.4 microns. Extinction spectra computed from in situ size distributions are consistent with optical depth measurements; both show initial spectra with lambda(sub max) <= 0.42 microns, thereafter increasing to 0.78 <= lambda(sub max) <= 1 micron. Not until 1993 do spectra begin to show a clear return to the preeruption signature of lambda(sub max) <= 0.42 microns. The twin signatures of large R(sub eff) (> 0.3 microns) and relatively flat extinction spectra (0.4 - 1 microns) are among the longest-lived indicators of Pinatubo volcanic influence. They persist for years after the peaks in number, mass, surface area, and optical depth at all wavelengths <= 1 microns. This coupled evolution in particle size distribution and optical depth spectra helps explain the relationship between global maps of 0.5- and 1.0-micron optical depth derived from the Advanced Very High Resolution Radiometer (AVHRR) and Stratospheric Aerosol and Gas Experiment (SAGE) satellite sensors. However, there are important differences between the AVHRR and SAGE midvisible optical thickness products. We discuss possible reasons for these differences and how they might be resolved.

Russell, P. B.↗

Proximal remote sensing: an essential tool for bridging the gap between high‐resolution ecosystem monitoring and global ecology

Summary A new proliferation of optical instruments that can be attached to towers over or within ecosystems, or ‘proximal’ remote sensing, enables a comprehensive characterization of terrestrial ecosystem structure, function, and fluxes of energy, water, and carbon. Proximal remote sensing can bridge the gap between individual plants, site‐level eddy‐covariance fluxes, and airborne and spaceborne remote sensing by providing continuous data at a high‐spatiotemporal resolution. Here, we review recent advances in proximal remote sensing for improving our mechanistic understanding of plant and ecosystem processes, model development, and validation of current and upcoming satellite missions. We provide current best practices for data availability and metadata for proximal remote sensing: spectral reflectance, solar‐induced fluorescence, thermal infrared radiation, microwave backscatter, and LiDAR. Our paper outlines the steps necessary for making these data streams more widespread, accessible, interoperable, and information‐rich, enabling us to address key ecological questions unanswerable from space‐based observations alone and, ultimately, to demonstrate the feasibility of these technologies to address critical questions in local and global ecology.

Plant Sciences↗

Enhancement of optical absorption by modulation of the oxygen flow of TiO{sub 2} films deposited by reactive sputtering

Oxygen-deficient TiO{sub 2} films with enhanced visible and near-infrared optical absorption have been deposited by reactive sputtering using a planar diode radio frequency magnetron configuration. It is observed that the increase in the absorption coefficient is more effective when the O{sub 2} gas supply is periodically interrupted rather than by a decrease of the partial O{sub 2} gas pressure in the deposition plasma. The optical absorption coefficient at 1.5 eV increases from about 1 Multiplication-Sign 10{sup 2} cm{sup -1} to more than 4 Multiplication-Sign 10{sup 3} cm{sup -1} as a result of the gas flow discontinuity. A red-shift of {approx}0.24 eV in the optical absorption edge is also observed. High resolution transmission electron microscopy with composition analysis shows that the films present a dense columnar morphology, with estimated mean column width of 40 nm. Moreover, the interruptions of the O{sub 2} gas flow do not produce detectable variations in the film composition along its growing direction. X-ray diffraction and micro-Raman experiments indicate the presence of the TiO{sub 2} anatase, rutile, and brookite phases. The anatase phase is dominant, with a slight increment of the rutile and brookite phases in films deposited under discontinued O{sub 2} gas flow. The increase of optical absorption in the visible and near-infrared regions has been attributed to a high density of defects in the TiO{sub 2} films, which is consistent with density functional theory calculations that place oxygen-related vacancy states in the upper third of the optical bandgap. The electronic structure calculation results, along with the adopted deposition method and experimental data, have been used to propose a mechanism to explain the formation of the observed oxygen-related defects in TiO{sub 2} thin films. The observed increase in sub-bandgap absorption and the modeling of the corresponding changes in the electronic structure are potentially useful concerning the optimization of efficiency of the photocatalytic activity and the magnetic doping of TiO{sub 2} films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray optics metrology limited by random noise, instrumental drifts, and systematic errors

Continuous, large-scale efforts to improve and develop third- and forth-generation synchrotron radiation light sources for unprecedented high-brightness, low emittance, and coherent x-ray beams demand diffracting and reflecting x-ray optics suitable for micro- and nano-focusing, brightness preservation, and super high resolution. One of the major impediments for development of x-ray optics with the required beamline performance comes from the inadequate present level of optical and at-wavelength metrology and insufficient integration of the metrology into the fabrication process and into beamlines. Based on our experience at the ALS Optical Metrology Laboratory, we review the experimental methods and techniques that allow us to mitigate significant optical metrology problems related to random, systematic, and drift errors with super-high-quality x-ray optics. Measurement errors below 0.2 mu rad have become routine. We present recent results from the ALS of temperature stabilized nano-focusing optics and dedicated at-wavelength metrology. The international effort to develop a next generation Optical Slope Measuring System (OSMS) to address these problems is also discussed. Finally, we analyze the remaining obstacles to further improvement of beamline x-ray optics and dedicated metrology, and highlight the ways we see to overcome the problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALMA 690 GHz OBSERVATIONS OF IRAS 16293-2422B: INFALL IN A HIGHLY OPTICALLY THICK DISK

We present sensitive, high angular resolution ({approx}0.''2) submillimeter continuum and line observations of IRAS 16293-2422B made with the Atacama Large Millimeter/Submillimeter Array. The 0.45 mm continuum observations reveal a single and very compact source associated with IRAS 16293-2422B. This submillimeter source has a deconvolved angular size of about 400 mas (50 AU) and does not show any inner structure inside of this diameter. The H{sup 13}CN, HC{sup 15}N, and CH{sub 3}OH line emission regions are about twice as large as the continuum emission and reveal a pronounced inner depression or ''hole'' with a size comparable to that estimated for the submillimeter continuum. We suggest that the presence of this inner depression and the fact that we do not see an inner structure (or a flat structure) in the continuum are produced by very optically thick dust located in the innermost parts of IRAS 16293-2422B. All three lines also show pronounced inverse P-Cygni profiles with infall and dispersion velocities larger than those recently reported from observations at lower frequencies, suggesting that we are detecting faster and more turbulent gas located closer to the central object. Finally, we report a small east-west velocity gradient in IRAS 16293-2422B that suggests that its disk plane is likely located very close to the plane of the sky.

79 ASTRONOMY AND ASTROPHYSICS↗

Aberration-corrected aspheric grating designs for the Lyman/Far-Ultraviolet Spectroscopic Explorer high-resolution spectrograph - A comparison

Two approaches to reducing the optical aberrations of concave diffraction gratings have been studied to obtain candidate grating designs for the Lyman/Far-Ultraviolet Spectroscopic Explorer mission. The first approach involves shaping the grating substrate while using straight and equally spaced grooves. The second approach involves using a gating substrate with a relatively simple figure and holographically controlling the groove curvature and spacing. Specific designs derived from both approaches are analyzed and compared.

Trout, Catherine↗

Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution

Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Inference of Ice Cloud Properties from High-spectral Resolution Infrared Observations

The theoretical basis is explored for inferring the microphysical properties of ice crystal from high-spectral resolution infrared observations. A radiative transfer model is employed to simulate spectral radiances to address relevant issues. The extinction and absorption efficiencies of individual ice crystals, assumed as hexagonal columns for large particles and droxtals for small particles, are computed from a combination of the finite- difference time-domain (FDTD) technique and a composite method. The corresponding phase functions are computed from a combination of FDTD and an improved geometric optics method (IGOM). Bulk scattering properties are derived by averaging the single- scattering properties of individual particles for 30 particle size distributions developed from in situ measurements and for additional four analytical Gamma size distributions for small particles. The non-sphericity of ice crystals is shown to have a significant impact on the radiative signatures in the infrared (IR) spectrum; the spherical particle approximation for inferring ice cloud properties may result in an overest&ation of the optical thickness and an inaccurate retrieval of effective particle size. Furthermore, we show that the error associated with the use of the Henyey-Greenstein phase function can be as larger as 1 K in terms of brightness temperature for larger particle effective size at some strong scattering wavenumbers. For small particles, the difference between the two phase functions is much less, with brightness temperatures generally differing by less than 0.4 K. The simulations undertaken in this study show that the slope of the IR brightness temperature spectrum between 790-960/cm is sensitive to the effective particle size. Furthermore, a strong sensitivity of IR brightness temperature to cloud optical thickness is noted within the l050-1250/cm region. Based on this spectral feature, a technique is presented for the simultaneous retrieval of the visible optical thickness and effective particle size from high spectral resolution infrared data under ice cloudy con&tion. The error analysis shows that the uncertainty of the retrieved optical thickness and effective particle size has a small range of variation. The error for retrieving particle size in conjunction with an uncertainty of 5 K in cloud'temperature, or a surface temperature uncertainty of 2.5 K, is less than 15%. The corresponding e m r in the uncertainty of optical thickness is within 5-2096, depending on the value of cloud optical thickness. The applicability of the technique is demonstrated using the aircraft-based High- resolution Interferometer Sounder (HIS) data from the Subsonic Aircraft: Contrail and Cloud Effects Special Study (SUCCESS) in 1996 and the First ISCCP Regional Experiment - Arctic Clouds Experiment (FIRE-ACE) in 1998.

Huang, Hung-Lung↗

Optical Lightning Detection From Space

Since 1995 we have had one or more optical lightning sensors in low earth orbit (LEO) providing near continuous lightning observations of the earth. The resulting data sets have enabled scientists to study global lighting distributions and their variable. Diurnal, seasonal and interannual variabilities are clearly revealed. In addition, because of the exceptionally high detection efficiency of the optical sensing technique and the high spatial resolution, it is possible to study individual clouds and cloud system despite a viewing time that is often as short as 80 seconds. These case studies have demonstrated the importance of total lightning measurements in the study of severe weather. Results from these space-based lightning measurements will be presented as well as the next logical concept - optical observations from geostationary orbit (GEO). With a Lightning Mapper Sensor (LMS) in GEO, it will be possible to monitor severe weather on a continuous basis and to disseminate the data in less than 60 seconds.

Christian, Hugh J., Jr.↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 08: A Low-Cost Optical Scanner and Gantry for use with 3D Printing of Radiation Therapy Accessories

Purpose: Three-dimensional printing has been implemented at our institution to create customized treatment accessories including shielding and bolus. In order to effectively use 3D printing, the topography of the patient must first be acquired. To this end, we have evaluated a low-cost structured-light 3D scanner in order to assess the clinical viability of this technology. Methods: For ease of use, the scanner (3D Systems, Sense 3D Scanner) was mounted in a simple gantry that guided its motion and maintained an optimum distance between the scanner and the object. To characterise the spatial accuracy of the scanner, we used a geometric phantom and an anthropomorphic head phantom. The geometric phantom was machined from plastic and had overall dimensions of 24 cm by 15 cm and included a hemispherical and a tetrahedron protrusion roughly the dimensions of an average forehead and nose respectively. Meshes acquired by the optical scanner were compared to meshes generated from high-resolution CT images. Results: Scans were acquired in under one minute. Most of the optical scans contained noticeable artefacts although in most instances these were considered minor. Using an algorithm that calculated distances between the two meshes, we found most of the optical scanner measurements agreed with those from CT to within about 1 mm for the geometric phantom and to within about 2 mm for the head phantom. Conclusion: In summary, we deemed this scanner to be clinically acceptable and it has been used to design treatment accessories for several skin cancer patients.

60 APPLIED LIFE SCIENCES↗

Inspection of commercial optical devices for data storage using a three Gaussian beam microscope interferometer

Recently, an interferometric profilometer based on the heterodyning of three Gaussian beams has been reported. This microscope interferometer, called a three Gaussian beam interferometer, has been used to profile high quality optical surfaces that exhibit constant reflectivity with high vertical resolution and lateral resolution near {lambda}. We report the use of this interferometer to measure the profiles of two commercially available optical surfaces for data storage, namely, the compact disk (CD-R) and the digital versatile disk (DVD-R). We include experimental results from a one-dimensional radial scan of these devices without data marks. The measurements are taken by placing the devices with the polycarbonate surface facing the probe beam of the interferometer. This microscope interferometer is unique when compared with other optical measuring instruments because it uses narrowband detection, filters out undesirable noisy signals, and because the amplitude of the output voltage signal is basically proportional to the local vertical height of the surface under test, thus detecting with high sensitivity. We show that the resulting profiles, measured with this interferometer across the polycarbonate layer, provide valuable information about the track profiles, making this interferometer a suitable tool for quality control of surface storage devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗