Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Clinical Significance of Accounting for Tissue Heterogeneity in Permanent Breast Seed Implant Brachytherapy Planning

Purpose: The inhomogeneity correction factor (ICF) method provides heterogeneity correction for the fast calculation TG43 formalism in seed brachytherapy. This study compared ICF-corrected plans to their standard TG43 counterparts, looking at their capacity to assess inadequate coverage and/or risk of any skin toxicities for patients who received permanent breast seed implant (PBSI). Methods and Materials: Two-month postimplant computed tomography scans and plans of 140 PBSI patients were used to calculate dose distributions by using the TG43 and the ICF methods. Multiple dose-volume histogram (DVH) parameters of clinical target volume (CTV) and skin were extracted and compared for both ICF and TG43 dose distributions. Short-term (desquamation and erythema) and long-term (telangiectasia) skin toxicity data were available on 125 and 110 of the patients, respectively, at the time of the study. The predictive value of each DVH parameter of skin was evaluated using the area under the receiver operating characteristic (ROC) curve for each toxicity endpoint. Results: Dose-volume histogram parameters of CTV, calculated using the ICF method, showed an overall decrease compared to TG43, whereas those of skin showed an increase, confirming previously reported findings of the impact of heterogeneity with low-energy sources. The ICF methodology enabled us to distinguish patients for whom the CTV V{sub 100} and V{sub 90} are up to 19% lower compared to TG43, which could present a risk of recurrence not detected when heterogeneity are not accounted for. The ICF method also led to an increase in the prediction of desquamation, erythema, and telangiectasia for 91% of skin DVH parameters studied. Conclusions: The ICF methodology has the advantage of distinguishing any inadequate dose coverage of CTV due to breast heterogeneity, which can be missed by TG43. Use of ICF correction also led to an increase in prediction accuracy of skin toxicities in most cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Dosimetric Differences in Strut-Adjusted Volume Implant Treatment Plans Calculated With TG-43 Formalism and a Model-Based Dose Calculation Algorithm

To comprehensively characterize dosimetric differences between calculations with a commercial model-based dose calculation algorithm (MBDCA) and the TG-43 formalism in application to accelerated partial breast irradiation (APBI) with the strut-adjusted volume implant (SAVI) applicator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Formation of tetragonal gas bubble superlattice in bulk molybdenum under helium ion implantation

In this paper, we report the formation of tetragonal gas bubble superlattice in bulk molybdenum under helium ion implantation at 573 K. The transmission electron microscopy study shows that the helium bubble lattice constant measured from the in-plane d-spacing is ~4.5 nm, while it is ~3.9 nm from the out-of-plane measurement. The results of synchrotron-based small-angle x-ray scattering agree well with the transmission electron microscopy results in terms of the measurement of bubble lattice constant and bubble size. The coupling of transmission electron microscopy and synchrotron high-energy X-ray scattering provides an effective approach to study defect superlattices in irradiated materials.

36 MATERIALS SCIENCE↗

Influence of metal nanocomposite morphology on Helium implantation response

This work reports on Helium (He) accumulation in novel metal nanocomposites fabricated by phase separation in three-dimensions. These nanocomposites are dense with semi-coherent interfaces that ultimately influence He implantation response. The effect of film morphology on three aspects of He response is investigated: size and distribution of He precipitates, He retention, and He-induced changes in mechanical properties. Here, transmission electron microscopy analysis showed that He bubbles agglomerated along the vertical phase boundaries in morphologies with lateral and random domains of Cu and Mo. Nuclear Reaction Analysis (NRA) and nanoindentation results show He retention and hardness is morphology dependent.

36 MATERIALS SCIENCE↗

Self-assembly of solid nanoclusters in molybdenum under gas ion implantation

The self-assembly of defects in materials could create unique physical and chemical properties. In nuclear fuels, the formation of self-assembled fission products mitigates fission-gas-release and swelling. In this work, we report the formation of a solid nanocluster superlattice in molybdenum, an important constituent in metallic fuels, under krypton gas ion implantation. X-ray absorption near edge structure measurements coupled with density functional theory calculations show that the pressure of krypton nanoclusters in molybdenum is ~2 GPa and molecular dynamic simulations reveal that the krypton atoms are solid in the nanoclusters with a krypton-to-vacancy ratio of ~0.28 at 300 K.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of the density of collision cascades on ion implantation damage in ZnO

We study structural disorder in ZnO bombarded at room temperature with 1.3 keV/amu atomic P and cluster PF{sub n} (n=2 and 4) ions. Rutherford backscattering/channeling spectrometry results show that the density of collision cascades has a negligible effect on the damage buildup in the crystal bulk in the dose range resulting in {approx}1.5-15 displacements per atom. Hence, the amount of stable post-implantation disorder in the bulk can be predicted based on ballistic calculations. In contrast, the cascade density affects radiation damage in the near-surface region. An intermediate defect peak between the expected surface and bulk peaks of disorder forms for ion irradiation conditions with dense cascades.

36 MATERIALS SCIENCE↗

Self-consistent circuit model for plasma source ion implantation

A self-consistent circuit model which can describe the dynamic behavior of the entire pulsed system for plasma source ion implantation has been developed and verified with experiments. In the circuit model, one-dimensional fluid equations of plasma sheath have been numerically solved with self-consistent boundary conditions from the external circuit model including the pulsed power system. Experiments have been conducted by applying negative, high-voltage pulses up to -10 kV with a capacitor-based pulse modulator to the planar target in contact with low-pressure argon plasma produced by radio-frequency power at 13.56 MHz. The measured pulse voltage and current waveforms as well as the sheath motion have shown good agreements with the simulation results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cracking in hydrogen ion-implanted Si/Si{sub 0.8}Ge{sub 0.2}/Si heterostructures

We demonstrate that a controllable cracking can be realized in Si with a buried strain layer when hydrogen is introduced using traditional H-ion implantation techniques. However, H stimulated cracking is dependent on H projected ranges; cracking occurs along a Si{sub 0.8}Ge{sub 0.2} strain layer only if the H projected range is shallower than the depth of the strained layer. The absence of cracking for H ranges deeper than the strain layer is attributed to ion-irradiation induced strain relaxation, which is confirmed by Rutherford-backscattering-spectrometry channeling angular scans. The study reveals the importance of strain in initializing continuous cracking with extremely low H concentrations.

36 MATERIALS SCIENCE↗

Revealing the surface origin of green band emission from ZnO nanostructures by plasma immersion ion implantation induced quenching

Surface defect passivation for ZnO nanocombs (NCBs), random nanowires (RNWs), and aligned nanowires (ANWs) was performed through a metal plasma immersion ion implantation with low bias voltages ranging from 0 to 10 kV, where Ni was used as the modification ion. The depth of surface-originated green band (GB) emission is thus probed, revealing the surface origin of the GB. It is also found that the GB is closely related to oxygen gas content during growth of the nanostructures. The GB origin of NCBs and RNWs grown with higher oxygen content is shallower ({approx}0.5 nm), which can be completely quenched with no bias applied. However, the GB origin of ANWs grown at lower oxygen content is much deeper ({approx}7 nm) with a complete quenching bias of 10 kV. Quenching of the GB can be attributed to passivation of the surface hole or electron trapping sites (oxygen vacancies) by Ni ions.

36 MATERIALS SCIENCE↗

Direct coupling of pulsed radio frequency and pulsed high power in novel pulsed power system for plasma immersion ion implantation

A novel power supply system that directly couples pulsed high voltage (HV) pulses and pulsed 13.56 MHz radio frequency (rf) has been developed for plasma processes. In this system, the sample holder is connected to both the rf generator and HV modulator. The coupling circuit in the hybrid system is composed of individual matching units, low pass filters, and voltage clamping units. This ensures the safe operation of the rf system even when the HV is on. The PSPICE software is utilized to optimize the design of circuits. The system can be operated in two modes. The pulsed rf discharge may serve as either the seed plasma source for glow discharge or high-density plasma source for plasma immersion ion implantation (PIII). The pulsed high-voltage glow discharge is induced when a rf pulse with a short duration or a larger time interval between the rf and HV pulses is used. Conventional PIII can also be achieved. Experiments conducted on the new system confirm steady and safe operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FTIR, Micro-Raman and Ellipsometry Studies on Silicon Oxynitride Layers Synthesized by Low Energy Ion Implantation

Single crystal silicon were implanted at room temperature with {sup 16}O{sub 2}{sup +} and {sup 14}N{sub 2}{sup +} 30 keV ions in 1:1 ratio with fluences of 2.5x10{sup 17}, 5x10{sup 17}, 7.5x10{sup 17} and 1x10{sup 18} ions-cm{sup -2} to form silicon oxynitride layers. Rapid thermal annealing (RTA) of these samples was carried out at temperature of 623, 873 and 1173 K in nitrogen ambient for 5 min. Fourier transform infrared (FTIR), Micro-Raman and ellipsometry measurements were performed on RTA samples to investigate the structure and phase. The FTIR studies show that the structures of ion-beam synthesized oxynitride layers are strongly dependent on total ion-fluence and annealing temperature. The Micro-Raman studies on annealing revealed formation of partially amorphous oxygen and nitrogen rich silicon oxynitride structures for lower and higher ion fluences respectively with crystalline silicon beneath it. From the ellipsometry studies, the refractive index of the ion beam synthesized layers were found to be in 1.54-1.96 range.

36 MATERIALS SCIENCE↗

Evidence for ion irradiation induced dissociation and reconstruction of Si-H bonds in hydrogen-implanted silicon

We observe that H-related chemical bonds formed in H-implanted Si will evolve under subsequent ion irradiation. During ion irradiation hydrogen is inclined to dissociate from simple H-related defect complexes (i.e., VH{sub x} and IH{sub x}), diffuse, and attach to vacancy-type defects resulting in new platelet formation, which facilitate surface blistering after annealing, a process completely inhibited in the absence of ion irradiation. The understanding of our results provides insight into the structure and stability of hydrogen-related defects in silicon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunable transport properties of n-type ZnO nanowires by Ti plasma immersion ion implantation

Single-crystalline, transparent conducting ZnO nanowires were obtained simply by Ti plasma immersion ion implantation (PIII). Electrical transport characterizations demonstrate that the n-type conduction of ZnO nanowire could be tuned by appropriate Ti-PIII. When the energy of PIII is increased, the resistivity of ZnO decreases from 4x10{sup 2} to 3.3x10{sup -3} {omega} cm, indicating a semiconductor-metal transition. The failure-current densities of the metallic ZnO could be up to 2.75x10{sup 7} A/cm{sup 2}. Therefore, this facile method may provide an inexpensive alternative to tin doped indium oxide as transparent conducting oxide materials.

36 MATERIALS SCIENCE↗

Two dimensionally patterned GaN{sub x}As{sub 1-x}/GaAs nanostructures using N{sup +} implantation followed by pulsed laser melting

We present measurements on two dimensionally patterned GaN{sub x}As{sub 1-x} dots fabricated in a GaAs matrix using ion implantation followed by pulsed laser melting and rapid thermal annealing. The lithographically patterned GaN{sub x}As{sub 1-x} regions are imaged by ballistic electron emission microscopy (BEEM). By analyzing the BEEM spectra of the locally confined dots, we observe the decrease in the Schottky barrier height with nitrogen incorporation. The second derivatives of BEEM currents from unpatterned GaN{sub x}As{sub 1-x} films exhibit a decrease in {gamma}-like thresholds as the nitrogen concentration increases. The composition dependence of the thresholds agrees well with that of previously studied low temperature molecular beam epitaxy grown alloys.

36 MATERIALS SCIENCE↗

Buried melting in germanium implanted silicon by millisecond flash lamp annealing

Flash lamp annealing in the millisecond range has been used to induce buried melting in silicon. For this purpose high dose high-energy germanium implantation has been employed to lower the melting temperature of silicon in a predetermined depth region. Subsequent flash lamp treatment at high energy densities leads to local melting of the germanium rich layer. The thickness of the molten layer has been found to depend on the irradiation energy density. During the cool-down period, epitaxial crystallization takes place resulting in a largely defect-free layer.

36 MATERIALS SCIENCE↗

Correlation of Beam Transport Characteristics and Mass Resolving Power to Analyzing Magnet Pole Piece Wear in Axcelis HE Ion Implanters

An investigation into odd analyzing magnet tuning behavior on an Axcelis HE ion implanter revealed a correlation to excessive wear on the analyzer magnet pole pieces. Though the lifetime is generally quite good, the pole pieces are internal to the beamline design and are exposed to and sputtered by the ion beam during mass analysis. This erosion of the pole piece surfaces affects beam focus and transport, especially for lower current ion beams. Eventually, automatic beam set-up fails altogether as the system is unable to locate the correct amu peak. It is important to understand and correct any deficiencies in pole piece condition as long-term neglect will eventually lead to process errors. Data is presented to illustrate good and bad pole piece condition and a method is suggested for non-invasive testing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlation of Measured Surface Contaminants as a Function of Ion Beam Current in GSD Ion Implanters

An investigation into measured differences in surface contaminant levels when evaluating several ion implant tools and/or tool types. For a given species and energy, beam current appears to have a strong effect on final contaminant levels. Ideally one evaluates process integrity at machine set-up conditions that approximate or exceed the worst case conditions required for regular, volume wafer production. Some contaminants may exhibit a 'threshold' effect where they are easily observed with sufficient beam current, but not present at all for lower beam currents. Knowing the characteristics of the measurement process is essential in obtaining reliable results with a clear interpretation and better facilitates cross-site or cross-platform comparisons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗