Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Synthesis of Endohedral Fullerene Using ECR Ion Source

We are developing an ECRIS apparatus which is designed for the production of endohedral fullerenes. Our promising approaches to produce the endohedral fullerenes using the ECRIS are the ion-ion collision reaction of fullerenes and the other atom in their mixture plasma and simple ion implantation of atom into fullerene layer. In this study, we tried to synthesize the endohedral nitrogen-fullerenes by ion implantation. N{sup +} beam was irradiated to a fullerene target with a specific energy and dose. As a result, we could observe the peak of N+C{sub 60} from targets after N{sup +} beam irradiation with TOF-SIMS and LDI-TOF-MS.

36 MATERIALS SCIENCE↗

PIBHI 2025: status and perspectives of ECR ion sources

The article summarizes the discussions held during the PIBHI 2025 workshop (https://agenda.infn.it/e/pibhi2025) highlighting the most significant points to have emerged. The main goal of the workshop was to foster dialogue on topics relevant to the ECR ion sources (ECRIS) community through dedicated and thematic round tables. The outcomes of these discussions are outlined below, with particular focus on the remaining open questions in the field.

43 PARTICLE ACCELERATORS↗

Calculation of plasma properties in ion sources

Simple algebraic equations are developed that can be used to calculate the average primary electron density, the average primary to Maxwellian density ratio, and the average Maxwellian electron temperature in the discharge chamber of a cusped magnetic field ion source. These properties may be calculated as functions of the propellant gas flow rate and the propellant utilization efficiency. Each of the plasma properties calculated using the model agrees well with the corresponding experimental data for both argon and xenon gases over a wide range of propellant flow rates and utilization efficiencies.

Brophy, J. R.↗

Negative hydrogen ion yields at plasma grid surface in a negative hydrogen ion source

Negative hydrogen (H{sup −}) ion yield from the plasma grid due to incident hydrogen ions and neutrals has been evaluated with the surface collision cascade model, ACAT (Atomic Collision in Amorphous Target) coupled to a negative surface ionization models. Dependence of negative ion fractions upon the velocity component normal to the surface largely affect the calculation results of the final energy and angular distributions of the H{sup −} ions. The influence is particularly large for H{sup −} ions desorbed from the surface due to less than several eV hydrogen particle implact. The present calculation predicts that H{sup −} ion yield can be maximized by setting the incident angle of hydrogen ions and neutrals to be 65 degree. The Cs thickness on the plasma grid should also affect the yields and mean energies of surface produced H{sup −} ions by back scattering and ion induced desorption processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Test Results for a Superconducting 28-GHz Ion Source Magnet for FRIB

© 2002-2011 IEEE. The superconducting ECR source magnet for the Facility for Rare Isotope Beams at Michigan State University was designed and built by the Superconducting Magnet Group at Lawrence Berkeley National Laboratory (LBNL). The 28-GHz NbTi ion source magnet features a sextupole-in-solenoids configuration, which is comparable to the VENUS ECR magnet operated at LBNL. A shell-based support structure using bladders and keys has been incorporated into the design to allow for adjustments of the preload and reversibility of the magnet assembly process. The magnet has been assembled and successfully tested to operational currents at LBNL. This paper describes the basic design of the magnet and the passive quench protection system. The test results are also presented, including the quench behavior of the magnet, the training performance, and the magnetic measurement results.

Arbelaez, Diego↗

Mechanical Study of a Superconducting 28-GHz Ion Source Magnet for FRIB

The superconducting electron cyclotron resonance (ECR) source magnet for the facility for rare isotope beams at Michigan State University was designed and built by the Superconducting Magnet Group at Lawrence Berkeley National Laboratory (LBNL) in 2017. The 28 GHz NbTi ion source magnet features a sextupole-in-solenoids configuration which is comparable to the VENUS ECR magnet operated at LBNL. However, the mechanical design of this magnet utilizes a shell-based support structure which allows fine adjustments to the sextupole preload and reversibility of the magnet assembly process. The magnet has been assembled and tested to operational currents at LBNL. This paper describes the mechanical analyses performed to estimate the sextupole's and solenoids' preloads. We will report on the 3-D finite element analysis during room temperature assembly, cool-down, and magnet excitation, and then describe the magnet preload operations. To conclude, we will describe the performance of the support structure during the quench training.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Caesium Free Negative Ion Sources for Neutral Beam Injectors: a Study of Negative Ion Production on Graphite Surface in Hydrogen and Deuterium Plasma

Negative ion generation on HOPG graphite surface has been studied in hydrogen and deuterium plasma. We measure Ion Distribution Function (IDF) of negative ions coming from graphite surface bombarded by positive ions in H{sub 2}/D{sub 2} plasmas. We showed that negative ions flux was proportional to positive ion flux and was strongly dependant on impinging energy. IDF study shows two generation mechanisms are involved: sputtering of adsorbed H/D as negative ions and, in a less important way, double electron capture. We compare H{sub 2}/D{sub 2} plasmas, and point out isotopic effect between H{sup -} and D{sup -} production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Ambient Pressure Pyroelectric Ion Source

The detection of volatile vapors of unknown species in a complex field environment is required in many different applications. Mass spectroscopic techniques require subsystems including an ionization unit and sample transport mechanism. All of these subsystems must have low mass, small volume, low power, and be rugged. A volatile molecular detector, an ambient pressure pyroelectric ion source (APPIS) that met these requirements, was recently reported by Caltech researchers to be used in in situ environments.

Beegle, Luther W.↗

Development of a variable-energy, high-intensity, pulsed-mode ion source for low-energy nuclear astrophysics studies

The primary challenge in directly measuring nuclear reaction rates near stellar energies is their small cross sections. The signal-to-background ratio in these complex experiments can be significantly improved by employing high-current (mA-range) beams and novel detection techniques. Therefore, the electron cyclotron resonance ion source at the Laboratory for Experimental Nuclear Astrophysics underwent a complete upgrade of its acceleration column and microwave system to obtain high-intensity, pulsed proton beams. The new column uses a compression design with O-ring seals for vacuum integrity. Its voltage gradient between electrode sections is produced by the parallel resistance of channels of chilled, deionized water. It also incorporates alternating, transverse magnetic fields for electron suppression and an axially adjustable beam extraction system. Following this upgrade, the operational bremsstrahlung radiation levels and high-voltage stability of the source were vastly improved, over 3.5 mA of target beam current was achieved, and an order-of-magnitude increase in normalized brightness was measured. Beam optics calculations, structural design, and further performance results for this source are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Switching regulator emission control circuit for ion sources

An electron emission control circuit of the switching regulator type operating at 100 kHz has been developed which maintains a constant emission current within 0.1% for a cathode power demand variation of approximately 100%. The power output stage has an efficiency of 67%, and the overall efficiency is 45% when driving a thoria-coated iridium cathode having a nominal resistance at operating temperature of 2.5 ohms. Under optimum conditions, the bus power demand is 1.75 W. The circuit is useful in controlling the electron emission current of ion sources in applications which involve a substantial variation of the cathode work function, such as oxygen partial pressure measurements over a large dynamic range.

Clay, F. P., Jr.↗

Improving efficiency of negative ion production in ion source with saddle antenna

Extraction of negative ions from a saddle antenna radio-frequency surface plasma source is considered. Several versions of new plasma generators with different antennas and magnetic field configurations were tested in the smal Oak Ridge National Laboratory Spallation Neutron Source Test Stand. The efficiency of positive ion generation in plasma has been improved to 200 mA/cm{sup 2} kW from 2.5 mA/cm{sup 2} kW. A small oven was developed for cesiation by cesium compounds and alloy decomposition. After cesiation, a current of negative ions to the collector was increased from 1 mA to 10 mA with 1.5 kW RF power in the plasma and longitudinal magnetic field B{sub l} ∼ 250 G. The specific efficiency of H{sup −} production was increased to 20 mA/cm{sup 2} kW from 2.5 mA/cm{sup 2} kW.

43 PARTICLE ACCELERATORS↗

Stable Chlorine Isotope Measurements of Astromaterials Using the Cs-Sputter Negative Ion Source of an Accelerator Mass Spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35Cl and 37Cl. Chlorine isotope variations (reported as δ37Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) [1] are documented to exceed 80‰ [2] between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history[3,4].The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements (Figure 1).This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ37Cl measurements using the Cs-sputter negative ion source of an existing accelerator mass spectrometer. A brief description of the methods used for this work is followed by the results of our δ37Cl measurements and a discussion of the technique’s possible applications.

Chlorine↗

The new Batch Mode Ion Source for stand-alone operation at the Facility for Rare Isotope Beams (FRIB)

Gas stoppers have been used for a long-standing successful science program at Michigan State University with stopped and rare-isotope beams produced by projectile fragmentation. The National Superconducting Cyclotron Laboratory’s Coupled Cyclotron Facility has recently transitioned into the Facility for Rare Isotope Beams (FRIB) laboratory to provide rare isotopes using a high-power superconducting linear accelerator and new production facilities. To allow the science program with stopped and reaccelerated beams to continue during the transition period, a stand-alone capability was added. The Batch Mode Ion Source (BMIS) was built and has been providing beams of long-lived and stable isotopes of a variety of elements for successful user experiments. Finally, the BMIS system is described and results from the production of various beams are presented.

47 OTHER INSTRUMENTATION↗

Self-induced steady-state magnetic field in the negative ion sources with localized rf power deposition

The study is in the scope of a recent activity on modeling of SPIDER (Source for Production of Ions of Deuterium Extracted from RF plasma) which is under development regarding the neutral beam injection heating system of ITER. The regime of non-ambipolarity in the source, established before, is completed here by introducing in the model the steady state magnetic field, self-induced in the discharge due to the dc current flowing in it. Strong changes in the discharge structure are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of adsorption and roughness upon the collision processes at the convertor surface of a plasma sputter negative ion source

Atomic collision processes associated with surface production of negative hydrogen ions (H{sup -}) by particle reflection at molybdenum surface immersed in hydrogen plasma have been investigated. To calculate sputtering yields of Cs, as well as energy spectra and angular distributions of reflected hydrogen atoms from molybdenum surface by H{sup +} ion and Cs{sup +} ion bombardments, a Monte Carlo simulation code ACAT (Atomic Collision in Amorphous Target) was run with the corresponding surface conditions. A fractal surface model has been developed and adopted to ACAT for evaluating the effect due to roughness of target material. The results obtained with ACAT have indicated that the retention of hydrogen atoms leads to the reduction in sputtering yields of Cs, and the surface roughness does largely affect the sputtering yields of Cs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental optimization of beam quality extracted from a duoplasmatron proton ion source

The LANSCE accelerator facility operates with two independent ion injectors for H⁺ and H⁻ particle beams. The H⁺ ion beam is formed using a duoplasmatron source followed by a 750 keV Cockroft-Walton accelerating column. Formation of an optimal plasma meniscus is an important feature for minimizing beam emittance, and maximizing beam brightness. A series of experiments were performed to find the optimal combination of extraction voltage and extracted current for the H⁺ beam. Measurements yielded the best ratio of beam perveance to Child–Langmuir perveance of 0.52 for maximizing beam brightness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A collisional radiative model of hydrogen plasmas developed for diagnostic purposes of negative ion sources

A collisional radiative model of low-pressure hydrogen plasmas is elaborated and applied in optical emission spectroscopy diagnostics of a single element of a matrix source of negative hydrogen ions. The model accounts for the main processes determining both the population densities of the first ten states of the hydrogen atom and the densities of the positive hydrogen ions H{sup +}, H{sub 2}{sup +}, and H{sub 3}{sup +}. In the calculations, the electron density and electron temperature are varied whereas the atomic and molecular temperatures are included as experimentally obtained external parameters. The ratio of the H{sub α} to H{sub β} line intensities is calculated from the numerical results for the excited state population densities, obtained as a solution of the set of the steady-state rate balance equations. The comparison of measured and theoretically obtained ratios of line intensities yields the values of the electron density and temperature as well as of the degree of dissociation, i.e., of the parameters which have a crucial role for the volume production of the negative ions.

74 ATOMIC AND MOLECULAR PHYSICS↗