Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Neutron Imaging of Al6061 Prepared by Solid-State Friction Stir Additive Manufacturing

Solid-state Friction Stir Additive Manufacturing has recently gained attention as a result of its capacity to fabricate large-scale parts while preserving the mechanical properties of the feedstock material. However, the correlation between the quality of layer-by-layer bonding of the deposited metal and processing parameters has remained unknown. Neutron imaging techniques, with 90% total transmission per cm, are employed for Al6061 parts fabricated by MELD ® Technology as a non-destructive evaluation approach for the first time to investigate the layer-by-layer structure of a stadium-shaped ingot in different sections. The post-processed results show the fabricated parts with an optimized set of processing parameters are void-free. However, the hydrocarbon-based feedstock lubricant segregates between the layers, which consequently may lead to non-uniform weaker mechanical properties along the build direction and stimulate crack initiation during mechanical loading. The tensile test results show 14% lower strain-to-failure values in alleged contaminated areas in transmission imaging results. Additionally, layer bonding is significantly impacted by hot-on-hot and hot-on-cold layer deposition schemes, especially for larger layer thicknesses.

36 MATERIALS SCIENCE↗

DYNAMICAL MASS MEASUREMENT OF THE YOUNG SPECTROSCOPIC BINARY V343 NORMAE AaAb RESOLVED WITH THE GEMINI PLANET IMAGER

We present new spatially resolved astrometry and photometry from the Gemini Planet Imager of the inner binary of the young multiple star system V343 Normae, which is a member of the β Pictoris (β Pic) moving group. V343 Normae comprises a K0 and mid-M star in a ∼4.5 year orbit (AaAb) and a wide 10″ M5 companion (B). By combining these data with archival astrometry and radial velocities we fit the orbit and measure individual masses for both components of M{sub Aa}=1.10±0.10 M{sub ⊙} and M{sub Ab}=0.290±0.018 M{sub ⊙}. Comparing to theoretical isochrones, we find good agreement for the measured masses and JHK band magnitudes of the two components consistent with the age of the β Pic moving group. We derive a model-dependent age for the β Pic moving group of 26 ± 3 Myr by combining our results for V343 Normae with literature measurements for GJ 3305, which is another group member with resolved binary components and dynamical masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Direction-dependent Corrections in Polarimetric Radio Imaging. I. Characterizing the Effects of the Primary Beam on Full-Stokes Imaging

Next generation radio telescope arrays are being designed and commissioned to accurately measure polarized intensity and rotation measures (RMs) across the entire sky through deep, wide-field radio interferometric surveys. Radio interferometer dish antenna arrays are affected by direction-dependent (DD) gains due to both instrumental and atmospheric effects. In this paper, we demonstrate the effect of DD errors of the parabolic dish antenna array on the measured polarized intensities of radio sources in interferometric images. We characterize the extent of polarimetric image degradation due to the DD gains through wide-band VLA simulations of representative point-source simulations of the radio sky at L band (1–2 GHz). We show that at the 0.5 gain level of the primary beam there is significant flux leakage from Stokes I to Q , U amounting to 10% of the total intensity. We further demonstrate that while the instrumental response averages down for observations over large parallactic angle intervals, full-polarization DD correction is required to remove the effects of DD leakage. We also explore the effect of the DD beam on the RM signals and show that while the instrumental effect is primarily centered around 0 rad-m{sup −2}, the effect is significant over a broad range of RM requiring full polarization DD correction to accurately reconstruct the RM synthesis signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Data supporting manuscript from L. Sheneman, G. Stephanopoulos, A.E. Vasdekis titled "Deep learning classification of lipid droplets in quantitative phase images" as currently under review at PLOS ONE. This includes: 1) raw and binary labeled Quantitative Phase Images (QPI) of Y. lipolytica cells used in the analyses described within the manuscript. 2) various derived data including classifier scores, etc.

Data supporting manuscript from L. Sheneman, G. Stephanopoulos, A.E. Vasdekis titled "Deep learning classification of lipid droplets in quantitative phase images" as currently under review at PLOS ONE. This includes: 1) raw and binary labeled Quantitative Phase Images (QPI) of Y. lipolytica cells used in the analyses described within the manuscript. 2) various derived data including classifier scores, etc.

ANN↗

Intelligent Image Analysis for Image-Guided Laser Hair Removal and Skin Therapy

We present the development of advanced automatic target recognition (ATR) algorithms for the hair follicles identification in digital skin images to accurately direct the laser beam to remove the hair. The ATR system first performs a wavelet filtering to enhance the contrast of the hair features in the image. The system then extracts the unique features of the targets and sends the features to an Adaboost based classifier for training and recognition operations. The ATR system automatically classifies the hair, moles, or other skin lesion and provides the accurate coordinates of the intended hair follicle locations. The coordinates can be used to guide a scanning laser to focus energy only on the hair follicles. The intended benefit would be to protect the skin from unwanted laser exposure and to provide more effective skin therapy.

laser hair removal↗

3D Characterization and Time-Lapse Imaging of the Desiccation Treatability Test at the Hanford BC-Cribs and Trenches Site using High Performance Electrical Resistivity Imaging

Contaminated vadose zone materials are a potential source of long-term groundwater contamination at many sites across the Department of Energy (DOE) complex. Deep vadose zone contamination presents a particularly challenging remedial problem due to the difficultly of locating contaminants and the expense of access and ex situ treatment. In situ remediation techniques, whereby remedial amendments must be delivered to contaminated soils, have been identified as a potential alternative. However, amendment delivery is typically uncertain and post delivery remedial performance is often not well understood due to limited information available from sparsely spaced boreholes. Recent advancements in electrical resistivity tomography (ERT) are being used to address these challenges at the Hanford site by providing remote, three-dimensional images of contaminant distribution and four-dimensional (three spatial dimensions plus the time dimension) images of in-situ vadose zone remediation processes. These capabilities were recently demonstrated with a large scale surface characterization effort and during a smaller scale desiccation treatability test at the Hanford BC-Cribs area. The results of these efforts demonstrate the utility of leveraging high-performance computing resources to process ERT data for 3D reconnaissance mapping of subsurface contaminants and for detailed 3D monitoring of vadose zone remediation efforts.

contamination↗

Imaging vs. non-imaging in long range neutron detection scenarios.

Standoff neutron detection technology has advanced in recent years, primarily for counterterrorism applications. Sandia National Laboratories has developed the Neutron Scatter Camera -- a fast neutron imaging system using liquid scintillator with potential applications in long range neutron detection. This talk will explore the pros, cons and practical uses of the Neutron Scatter Camera versus more traditional neutron detectors such as He-3 proportional counters. Several applications for neutron detection and imaging will be explored. We will perform predictive calculations of the response of the Neutron Scatter Camera and traditional He-3 detectors. The applications range from counterterrorism to arms control to safeguards. We will discuss future evolution of the scatter camera to enhance long range detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent diffractive imaging using randomly coded masks

We experimentally demonstrate an extension to coherent diffractive imaging that encodes additional information through the use of a series of randomly coded masks, removing the need for typical object-domain constraints while guaranteeing a unique solution to the phase retrieval problem. Phase retrieval is performed using a numerical convex relaxation routine known as “PhaseCut,” an iterative algorithm known for its stability and for its ability to find the global solution, which can be found efficiently and which is robust to noise. The experiment is performed using a laser diode at 532.2 nm, enabling rapid prototyping for future X-ray synchrotron and even free electron laser experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emerging In Situ and Operando Nanoscale X‐Ray Imaging Techniques for Energy Storage Materials

Electrical vehicles (EVs) are an attractive option for moving towards a CO 2 neutral transportation sector, but in order for widespread commercial use of EVs, the cost of electrical energy storage (i.e., batteries) must be reduced and the energy storage capacity must be increased. New, higher performing but Earth abundant electrodes are needed to accomplish this goal. To aid the development of these materials, in situ characterization to understand battery operation and failure is essential. Since electrodes are inherently heterogeneous, with a range of relevant length scales, imaging is a necessary component of the suite of characterization methods. In this Feature Article, the rapidly growing and developing field of X‐ray based microscopy (XM) techniques is described and reviewed focusing on in situ and operando adaptations. Further, in situ transmission electron microscopy (TEM) is briefly discussed in this context and its complement to XM is emphasized. Finally, a perspective is given on some emerging X‐ray based imaging approaches for energy storage materials.

Nelson Weker, Johanna↗

Quaternary Ammonium Salt Based NIR‐II Probes for In Vivo Imaging

Abstract Traditional luminescent materials including fluorescent probes suffer from notorious aggregation‐caused quenching in aqueous solutions. Although several approaches such as the aggregation‐induced emission effect have been developed, it remains a significant challenge to identify an effective and efficient strategy to resolve this issue. Herein, quaternary ammonium salts Q8PBn and Q8PNap as a novel class of bright near infrared window II (NIR‐II, 1000–1700 nm) probes are designed and synthesized, and the twisted intramolecular charge transfer formation at the excited state can be effectively suppressed for the newly designed probes. Furthermore, Q8PNap complexation with fetal bovine serum ( Q8PNap /FBS) significantly increases the quantum yield by ≈32‐fold compared with PEGylated tertiary amine Q8P , and Q8PNap /FBS is successfully used to achieve high spatial and temporal resolution imaging of hind limb vasculature, lymphatic system, and small tumor metastasis, as well as precise NIR‐II imaging‐guided tumor and lymph node surgery in small animal models for the first time.

Qu, Chunrong↗

Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging

Background: There are limited data on the impact of the imaging protocol (single-day stress-rest, SD, vs. dual-day, DD) on the change in left ventricular (LV) ejection fraction (EF) (post-stress-rest) in relation to ischemia and on outcome. Methods: Using propensity score matching procedure, 490 of 1121 patients with known CAD, undergoing a SD or a DD in a multicenter study, were evaluated. Stress and rest gated-SPECT myocardial perfusion imaging was used to quantify LV perfusion, EF, and volumes. Outcome was assessed at an average follow-up time of 3.2 years. Results: Post-stress LVEF in SD and DD were comparable across all degrees of ischemia. The change in LVEF in patients with severe ischemia was, however, higher in the DD protocol, independent of the extent of CAD. At follow-up, 240 patients (49.0%) required coronary revascularization (CR) and 52 patients (10.6%) had hard events. The ischemic burden was independently associated with CR and hard-events; the post-stress LVEF was associated with CR but the change in EF was not predictive of either CR or hard events. Conclusions: In patients with severe ischemia, underestimation of post-stress myocardial stunning could be observed with the SD protocol. Post-stress LVEF and the extent ischemia, but not the change in EF, are predictive of CR and hard events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗