Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

C-smithing of Voyager 2 non-imaging instrument pointing information at Uranus

The development of a family of techniques, collectively called C-smithing, for improving spacecraft nonimaging instrument pointing knowledge is discussed. C-smithing studies using data from the Voyager 2 Uranus Encounter show that significant improvements in pointing knowledge for nonimaging instruments can be achieved with these techniques. This improved pointing information can be used to regenerate instrument viewing geometry parameters for the encounter, which can then be made available to science investigators.

Wang, Tseng-Chan↗

The recalibration of the IUE scientific instrument

The IUE instrument was recalibrated because of long time-scale changes in the scientific instrument, a better understanding of the performance of the instrument, improved sets of calibration data, and improved analysis techniques. Calibrations completed or planned include intensity transfer functions (ITF), low-dispersion absolute calibrations, high-dispersion ripple corrections and absolute calibrations, improved geometric mapping of the ITFs to spectral images, studies to improve the signal-to-noise, enhanced absolute calibrations employing corrections for time, temperature, and aperture dependence, and photometric and geometric calibrations for the FES.

Imhoff, Catherine L.↗

Nitric acid oxide mixing ratio measurements using a rocket launched chemiluminescent instrument

A total of 18 rocket launched parachute borne nitric oxide instruments were launched from 1977 to 1985. A very precise instrument for the measurement of the nitric oxide mixing ratio was fabricated. No changes were made in the main body of the instruments, i.e., things associated with the reaction volume. Except for the last 4 launches, however, it did not yield the required absolute values that was hoped for. Two major problems were encountered. First, the wrong choice of the background calibration gas, nitrogen, caused the first 10 data sets to be too low in the absolute mixing ratio by nearly the order of 2 to 5 ppbv. The error was realized, and air was substituted for the bias gas measurement. Second, in the desire to extend the measurement to higher altitudes, the problem of contaminating the inlet flow tube with ozone from the reagent gas was encountered. The ozone valve was opened too early in the flight and this caused the pressure in the reaction volume to exceed the pressure at the flow tube entrance, permitting the ozone to migrate backwards. This problem was restricted to an altitude above 45 km.

Horvath, Jack J.↗

A Mars orbital laser altimeter for rover trafficability: Instrument concept and science potential

Limited information on the types of geologic hazards (boulders, troughs, craters etc.) that will affect rover trafficability on Mars are available for the two Viking Lander sites, and there are no prospects for increasing this knowledge base in the near future. None of the instrument payloads on the upcoming Mars Observer or Soviet PHOBOS missions can directly measure surface obstacles on the scales of concern for rover safety (a few meters). Candidate instruments for the Soviet Mars 92 orbiter/balloon/rover mission such as balloon-borne stereo imaging, rover panoramic imaging, and orbital synthetic aperature imaging (SAR) are under discussion, but data from this mission may not be available for target areas of interest for the U.S. Mars Rover Sample Return (MRSR) mission. In an effort to determine how to directly measure the topography of surface obstacles that could affect rover trafficability on Mars, we are studying how to design a laser altimeter with extremely high spatial and vertical resolution that would be suitable for a future Mars Orbiter spacecraft (MRSR precursor or MRSR orbiter). This report discusses some of the design issues associated with such an instrument, gives examples of laser altimeter data collected for Mars analog terrains on Earth, and outlines the scientific potential of data that could be obtained with the system.

Garvin, J. B.↗

NASA Aircraft-Satellite Instrument Calibration Project

Ground based prelaunch calibration of satellite instruments usually is not adequate to provide an accurate characterization of the in-orbit performance of a satellite instrument. This is because the ground calibrations may not simulate the in-orbit environment observations of the satellite sensor, or because the sensor characteristics have changed during launch and in-orbit operations. One technique to obtain a meaningful in-orbit calibration of satellite sensors is to acquire simultaneous observations of an Earth scene with the satellite and a well calibrated aircraft or shuttle sensor which has similar characteristics to the satellite sensor. This is a direct in-orbit calibration technique and is usually called vicarious calibration. The experiment with the control instrument must occur above the sensible atmosphere as measured by the satellite sensor to provide a useful improvement to the calibration of the satellite sensor. Some observations on the experiments are made.

Guenther, B. W.↗

Soho and Cluster - The scientific instruments

The mission goals and instrumentation of the Soho and cluster spacecraft to be launched in 1995 as part of the international Solar-Terrestrial Science Program are discussed. Instruments such as normal-incidence, grazing-incidence, and EUV coronal spectrometers aboard the Soho spacecraft will study the origin of the solar wind and the physical properties of the solar atmosphere. The four Cluster spacecraft will measure electric and magnetic fields, plasmas, and energetic particles using instruments including a wide-band receiver system, a relaxation sounder, and a search coil magnetometer.

Domingo, V.↗

A method of gravity release compensation in the optical alignment of orbiting meteorological sounding and imaging instruments

This paper describes a method developed for precompensating the front-end (telescope) optical alignment of the Imager and Sounder radiometric instruments, which will be launched as components of the GOES I - M series of meteorological satellites. To satisfy the severe pointing accuracy requirements on these instruments, their alignments must be offset in the one - G field of the laboratory, in order that they will be correct in orbit. A method was developed to make the necessary alignment offset, using a counterweight mechanism; autocollimation returns from reference mirrors on the instrument structure and supporting fixturing provided feedback for adjusting the counterweight mechanism. A series of experiments was performed to verify that these autocollimation return measurements were a good predictor of telescope line-of-sight changes; these experiments are described and their results summarized.

Wetzel, James C.↗

Two Radiative/Thermochemical Instruments

Measurements of absorption and emission complement thermal measurements. Two laboratory instruments for research in combustion and pyrolysis equipped for radiative as well as thermal measurements. One instrument essentially differential scanning calorimeter (DSC) modified to detect radiation emitted by flames. Provides means to evaluate limits of flammability of materials exhibiting exothermic reactions in DSC's. Other instrument used to determine pyrolysis properties of specimens exposed to various gases by measurement of infrared absorption spectra of pyrolysis products.

Tapphorn, Ralph M.↗

Independent Orbiter Assessment (IOA): Assessment of instrumental subsystem FMEA/CIL

The McDonnell Douglas Astronautics Company (MDAC) was selected in June 1986 to perform an Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL). The IOA effort first completed an analysis of the Instrumentation hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison for the Orbiter Instrumentation hardware are documented. The IOA product for Instrumentation analysis consisted of 107 failure mode worksheets that resulted in 22 critical items being identified. Comparison was made to the Pre 51-L NASA baseline with 14 Post 51-L FMEAs added, which consists of 96 FMEAs and 18 CIL items. This comparison produced agreement on all but 25 FMEAs which caused differences in 5 CIL items.

Gardner, J. R.↗

NCTM workshop splinter session, IR thermal measurement instruments

The splinter session dealing with commercial industrial thermal measurement state-of-the-hardware had a total attendance of 15. Two papers were presented in the splinter session as follows: (1) Development of an Infrared Imaging System for the Surface Tension Driven Convection Experiment, Alexander D. Pline, NASA LeRC; (2) A Space-qualified PtSi Thermal Imaging System, Robert W. Astheimer, Barnes Engineering Div., EDO Corp. In addition a brief description of SPRITE detector technology was presented by Richard F. Leftwich of Magnovox. As anticipated, the discussions were concerned mainly with thermal imaging figures of merit rather than those for point measurement instruments. The need for uniform guidelines whereby infrared thermal imaging instruments could be specified and evaluated was identified as most important, particularly where temperature measurements are required. Presently there are differences in the way different manufacturers present significant performance parameters in their instrument data sheets. Furthermore, the prospective user has difficulty relating these parameters to actual measurement needs, and procedures by which performance can be verified are poorly defined. The current availability of powerful thermal imaging diagnostic software was discussed.

Kaplan, Herbert↗

Laser diffraction particle sizing: Instrument probe volume relocation and elongation

The effective probe volume of laser diffraction particle sizing instruments depends on many instrument parameters. In particular the probe volume axial boundaries and its location along laser beam are essentially defined by the onset of a vignetting effect where light scattered at large angles from small particles misses the transform lens. This vignetting effect results in a probe volume that must be inconveniently close to the lens in order to detect smaller diameter particles (less than 100 micrometers). With the addition of an appropriately designed Keplerian telescope, the probe volume may be relocated and elongated. The theory of operation of this supplemental optical system is described. Design considerations for these supplemental optical systems are described, including recommendations for lens specifications, assembly and use. An image transfer system is described which has been designed for use on a Malvern 2600HSD instrument. Experimental validation of this image transfer system is described.

Anderson, Robert C.↗

Foundations of measurement and instrumentation

The user of instrumentation has provided an understanding of the factors that influence instrument performance, selection, and application, and of the methods of interpreting and presenting the results of measurements. Such understanding is prerequisite to the successful attainment of the best compromise among reliability, accuracy, speed, cost, and importance of the measurement operation in achieving the ultimate goal of a project. Some subjects covered are dimensions; units; sources of measurement error; methods of describing and estimating accuracy; deduction and presentation of results through empirical equations, including the method of least squares; experimental and analytical methods of determining the static and dynamic behavior of instrumentation systems, including the use of analogs.

Warshawsky, Isidore↗

Perception-action relationships reconsidered in light of spatial display instruments

Spatial display instruments convey information about both the identity and the location of objects in order to assist surgeons, astronauts, pilots, blind individuals, and others in identification, remote manipulations, navigation, and obstacle avoidance. Scientists believe that these instruments have not reached their full potential and that progress toward new applications, including the possibility of restoring sight to the blind, will be accelerated by advancing the understanding of perceptual processes. This stimulating challenge to basic researchers was advanced by Paul Bach-Y-Rita (1972) and by the National Academy of Science (1986) report on Electronic Aids for the Blind. Although progress has been made, new applications of spatial display instruments in medicine, space, aviation, and rehabilitation await improved theoretical and empirical foundations.

Shebilske, Wayne L.↗

Space Infrared Telescope Facility (SIRTF) science instruments

Concepts of scientific instruments designed to perform infrared astronomical tasks such as imaging, photometry, and spectroscopy are discussed as part of the Space Infrared Telescope Facility (SIRTF) project under definition study at NASA/Ames Research Center. The instruments are: the multiband imaging photometer, the infrared array camera, and the infrared spectograph. SIRTF, a cryogenically cooled infrared telescope in the 1-meter range and wavelengths as short as 2.5 microns carrying multiple instruments with high sensitivity and low background performance, provides the capability to carry out basic astronomical investigations such as deep search for very distant protogalaxies, quasi-stellar objects, and missing mass; infrared emission from galaxies; star formation and the interstellar medium; and the composition and structure of the atmospheres of the outer planets in the solar sytem.

Ramos, R.↗

A cryogenically cooled photofragment fluorescence instrument for measuring stratospheric water vapor

An instrument developed for high-resolution daytime measurements of water vapor in the stratosphere using the technique of photofragment fluorescence is examined. A detailed description of all aspects of the instrument, as well as the results of its first two flights, are presented. The main areas of concern were optical baffling, cryogen transfer, water vapor measurement without contamination, and a dual path absorption measurement. Results of the second flight test indicate that the problems of instrument and gondola contamination, identified in the first flight test, were solved. A signal-to-noise ratio of about 50:1 for 10 sec of averaging throughout the stratosphere is achieved, as well as an altitude resolution of better than 100 m.

Weinstock, Elliot M.↗

Operational overview of NASA GTE/CITE 2 airborne instrument intercomparisons - Nitrogen dioxide, nitric acid, and peroxyacetyl nitrate

This paper provides the rationale, objectives, approach, and a brief description of the instrumentation included in the second airborne Chemical Instrumentation Test and Evaluation (CITE 2) mission conducted on NASA's Electra aircraft. CITE 2 intercompared data from instruments measuring NO2, HNO3, and PAN in the troposphere. This study, conducted in August 1986, encountered marine and continental air with free tropospheric mixing ratios of NO2, HNO3, and PAN typically less than 120, 150, and 200 parts per trillion by volume, respectively.

Hoell, James M., Jr.↗

COBE Differential Microwave Radiometers - Instrument design and implementation

Differential Microwave Radiometers (DMRs) at frequencies of 31.5, 53, and 90 GHz have been designed and built to map the large angular scale variations in the brightness temperature of the cosmic microwave background radiation. The instrument is being flown aboard NASA's Cosmic Background Explorer (COBE) satellite, launched on November 18, 1989. Each receiver input is switched between two antennas pointing 60 deg apart on the sky. The satellite is in near-polar orbit with the orbital plane precessing at 1 deg per day, causing the beams to scan the entire sky in 6 months. In 1 year of observation, the instruments are capable of mapping the sky to an rms sensitivity of 0.1 mK per 7 deg field of view. The mission and the instrument have been carefully designed to minimize the need for systematic corrections to the data.

Smoot, G.↗

Innovative operating modes and techniques for the spaceborne imaging radar-C instrument

The operation of the spaceborne imaging radar-C (SIR-C) is discussed. The SIR-C instrument has been designed to obtain simultaneous multifrequency and simultaneous multipolarization radar images from a low earth orbit. It is a multiparameter imaging radar which will be flown during at least two different seasons. The instrument has been designed to operate in innovative modes such as the squint alignment mode, the extended aperture mode, the scansar mode, and the interferometry mode. The instrument has been designed to demonstrate innovative engineering techniques such as beam nulling for echo tracking, pulse-repetition frquency hopping for Doppler centroid tracking, generating the frequency step chirp for radar parameter flexibility, block floating point quantizing for data rate compression, and elevation beamwidth broadening for increasing the swath illumination.

Huneycutt, Bryan L.↗