Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Structure and Flow-Viscosity of Filled-Polymer-Based 3D Printing Ink: Exploration through Coarse-Grained Molecular Dynamics

The addition of nanofiller particles to a polymer matrix has long been known to enhance or modify the composite’s mechanical and rheological properties. However, quantitatively capturing such changes with molecular level simulations remains computationally challenging. Toward that goal, we performed coarse-grained molecular dynamics of a nanocomposite system at a fixed (25 vol %) filler loading under nonspecific, weak polymer–filler interactions representative of a broad class of technologically important materials. We report several interesting results, including: (1) the equilibrium chain-configuration remains Gaussian-like as in an unfilled melt; (2) smaller filler particles display a stronger tendency to cluster; (3) larger fillers act as plasticizers by reducing the entanglement density and accelerating the chain mobility; and (4) fillers enhance the tensile response modulus, with the effect being stronger for larger particles. We also simulate cluster breakup, yielding, and elongational flow under an applied time-linear tensile strain and study the flow viscosity as a function of filler-size and chain-length.

Materials science↗

TH-E-BRE-05: Analysis of Dosimetric Characteristics in Two Leaf Motion Calculator Algorithms for Sliding Window IMRT

Purpose: The Smart leaf motion calculator (SLMC) in Eclipse treatment planning system is an advanced fluence delivery modeling algorithm as it takes into account fine MLC features including inter-leaf leakage, rounded leaf tips, non-uniform leaf thickness, and the spindle cavity etc. In this study, SLMC and traditional Varian LMC (VLMC) algorithms were investigated, for the first time, in dosimetric characteristics and delivery accuracy of sliding window (SW) IMRT. Methods: The SW IMRT plans of 51 cancer cases were included to evaluate dosimetric characteristics and dose delivery accuracy from leaf motion calculated by SLMC and VLMC, respectively. All plans were delivered using a Varian TrueBeam Linac. The DVH and MUs of the plans were analyzed. Three patient specific QA tools - independent dose calculation software IMSure, Delta4 phantom, and EPID portal dosimetry were also used to measure the delivered dose distribution. Results: Significant differences in the MUs were observed between the two LMCs (p≤0.001).Gamma analysis shows an excellent agreement between the planned dose distribution calculated by both LMC algorithms and delivered dose distribution measured by three QA tools in all plans at 3%/3 mm, leading to a mean pass rate exceeding 97%. The mean fraction of pixels with gamma < 1 of SLMC is slightly lower than that of VLMC in the IMSure and Delta4 results, but higher in portal dosimetry (the highest spatial resolution), especially in complex cases such as nasopharynx. Conclusion: The study suggests that the two LMCs generates the similar target coverage and sparing patterns of critical structures. However, SLMC is modestly more accurate than VLMC in modeling advanced MLC features, which may lead to a more accurate dose delivery in SW IMRT. Current clinical QA tools might not be specific enough to differentiate the dosimetric discrepancies at the millimeter level calculated by these two LMC algorithms. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.

60 APPLIED LIFE SCIENCES↗

WE-A-304-01: Strategies and Technologies for Cranial Radiosurgery Planning: MLC-Based Linac

The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.

60 APPLIED LIFE SCIENCES↗

WE-A-304-02: Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife

The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.

60 APPLIED LIFE SCIENCES↗

Analysis of a Symmetric Terahertz Dielectric-Lined Rectangular Structure for High Gradient Acceleration

We study, using computational methods based on analytic theory as well as a PIC code, the wakefields set up in a seven-zone symmetric rectangular THZ structure, and find that for overall transverse x/y dimensions 2.121 mmx0.6 mm, two 5-GeV drive bunches (3 nC, with x/y/z dimensions 0.3/0.3/0.12 mm{sup 3} as available at SLAC) will set up an axial wakefield {approx}350 MV/m in the witness channel, with a transformer ratio {approx}18-20. The symmetry of the structure ensures not only that small transverse forces are imposed on the witness bunch, but also that the two components of transverse force are equal and opposite at the bunch location so as to enable dynamical stabilization in an accelerator comprising many modules. Transverse forces on the drive bunch tails may allow bunches to move {approx}0.5-1 m without suffering excessive erosion.

43 PARTICLE ACCELERATORS↗

THE PHYSICS OF PROTOPLANETESIMAL DUST AGGLOMERATES. V. MULTIPLE IMPACTS OF DUSTY AGGLOMERATES AT VELOCITIES ABOVE THE FRAGMENTATION THRESHOLD

In recent years, a number of new experiments have advanced our knowledge on the early growth phases of protoplanetary dust aggregates. Some of these experiments have shown that collisions between porous and compacted agglomerates at velocities above the fragmentation threshold velocity can lead to growth of the compact body, when the porous collision partner fragments upon impact and transfers mass to the compact agglomerate. To obtain a deeper understanding of this potentially important growth process, we performed laboratory and drop tower experiments to study multiple impacts of small, highly porous dust-aggregate projectiles onto sintered dust targets. The projectile and target consisted of 1.5 {mu}m monodisperse, spherical SiO{sub 2} monomers with volume filling factors of 0.15 {+-} 0.01 and 0.45 {+-} 0.05, respectively. The fragile projectiles were accelerated by a solenoid magnet and combined with a projectile magazine with which 25 impacts onto the same spot on the target could be performed in vacuum. We measured the mass-accretion efficiency and the volume filling factor for different impact velocities between 1.5 and 6.0 m s{sup -1}. The experiments at the lowest impact speeds were performed in the Bremen drop tower under microgravity conditions to allow partial mass transfer also for the lowest adhesion case. Within this velocity range, we found a linear increase of the accretion efficiency with increasing velocity. In the laboratory experiments, the accretion efficiency increases from 0.12 to 0.21 in units of the projectile mass. The recorded images of the impacts showed that the mass transfer from the projectile to the target leads to the growth of a conical structure on the target after less than 100 impacts. From the images, we also measured the volume filling factors of the grown structures, which ranged from 0.15 (uncompacted) to 0.40 (significantly compacted) with increasing impact speed. The velocity dependency of the mass-transfer efficiency and the packing density of the resulting aggregates augment our knowledge of the aggregate growth in protoplanetary disks and should be taken into account for future models of protoplanetary dust growth.

79 ASTRONOMY AND ASTROPHYSICS↗

VMAT QA: Measurement-guided 4D dose reconstruction on a patient

Purpose: To develop and validate a volume-modulated arc therapy (VMAT) quality assurance (QA) tool that takes as input a time-resolved, low-density ({approx}10 mm) cylindrical surface dose map from a commercial helical diode array, and outputs a high density, volumetric, time-resolved dose matrix on an arbitrary patient dataset. This first validation study is limited to a homogeneous 'patient.'Methods: A VMAT treatment is delivered to a diode array phantom (ARCCHECK, Sun Nuclear Corp., Melbourne, FL). 3DVH software (Sun Nuclear) derives the high-density volumetric dose using measurement-guided dose reconstruction (MGDR). MGDR cylindrical phantom results are then used to perturb the three-dimensional (3D) treatment planning dose on the patient dataset, producing a semiempirical volumetric dose grid. Four-dimensional (4D) dose reconstruction on the patient is also possible by morphing individual sub-beam doses instead of the composite. For conventional (3D) dose comparison two methods were developed, using the four plans (Multi-Target, C-shape, Mock Prostate, and Head and Neck), including their structures and objectives, from the AAPM TG-119 report. First, 3DVH and treatment planning system (TPS) cumulative point doses were compared to ion chamber in a cube water-equivalent phantom ('patient'). The shape of the phantom is different from the ARCCHECK and furthermore the targets were placed asymmetrically. Second, coronal and sagittal absolute film dose distributions in the cube were compared with 3DVH and TPS. For time-resolved (4D) comparisons, three tests were performed. First, volumetric dose differences were calculated between the 3D MGDR and cumulative time-resolved patient (4D MGDR) dose at the end of delivery, where they ideally should be identical. Second, time-resolved (10 Hz sampling rate) ion chamber doses were compared to cumulative point dose vs time curves from 4D MGDR. Finally, accelerator output was varied to assess the linearity of the 4D MGDR with global fluence change. Results: Across four TG-119 plans, the average PTV point dose difference in the cube between 3DVH and ion chamber is 0.1 {+-} 1.0%. Average film vs TPS {gamma}-analysis passing rates are 83.0%, 91.1%, and 98.4% for 1%/2 mm, 2%/2 mm, and 3%/3 mm threshold combinations, respectively, while average film vs 3DVH {gamma}-analysis passing rates are 88.6%, 96.1%, and 99.5% for the same respective criteria. 4D MGDR was also sufficiently accurate. First, for 99.5% voxels in each case, the doses from 3D and 4D MGDR at the end of delivery agree within 0.5%local dose-error/1 mm distance. Moreover, all failing voxels are confined to the edge of the cylindrical reconstruction volume. Second, dose vs time curves track between the ion chamber and 4D MGDR within 1%. Finally, 4D MGDR dose changes linearly with the accelerator output: the difference between cumulative ion chamber and MGDR dose changed by no more than 1% (randomly) with the output variation range of 10%. Conclusions: Even for a well-commissioned TPS, comparison metrics show better agreement on average to MGDR than to TPS on the arbitrary-shaped measurable 'patient.' The method requires no more accelerator time than standard QA, while producing more clinically relevant information. Validation in a heterogeneous thoracic phantom is under way, as is the ultimate application of 4D MGDR to virtual motion studies.

60 APPLIED LIFE SCIENCES↗

Emittance estimation by an ion optical element with variable focusing strength and a viewing target

The emittance of an extracted ion beam can be estimated to first order by a series of three linear independent profile measurements. This estimation is restricted to the evaluation of an upper limit of the emittance value for a homogeneous, nonfilamented beam. The beam is assumed to be round, respectively elliptical, without any structure of the intensity distribution, no space charge has been assumed for the drifting beam, and the optics is assumed to be linear. Instead of using three different drift sections, a linear focusing element with three different focusing strengths can be used. Plotting the beam radius as function of focusing strength, three independent solutions can be used to calculate the Twiss parameters {alpha}, {beta}, and {gamma} and furthermore the emittance {epsilon}. Here we describe the measurements which have been performed with the SECRAL ion source at Institute of Modern Physics Lanzhou.

43 PARTICLE ACCELERATORS↗

Demonstration of the High RF Power Production Feasibility in the CLIC Power Extraction and Transfer Structure (PETS)

A fundamental element of the CLIC concept is two-beam acceleration, where RF power is extracted from a high current, low energy drive beam in order to accelerate the low current main beam to high energy. The CLIC Power Extraction and Transfer Structure (PETS) is a passive microwave device in which bunches of the drive beam interact with the constant impedance of the periodically loaded waveguide and excite preferentially the synchronous mode. The RF power produced is collected downstream of the structure by means of the RF power extractor; it is delivered to the main linac using the waveguide network connecting the PETS to the main CLIC accelerating structures. The PETS should produce 135 MW at 240 ns RF pulses at a very low breakdown rate: BDR < 10{sup -7}/pulse/m. Over 2010, a thorough high RF power testing program was conducted in order to investigate the ultimate performance and the limiting factors for the PETS operation. The testing program is described and the results are presented.

43 PARTICLE ACCELERATORS↗

Warm Unit Stand Analysis for Proton Improvement Project II

The Proton Improvement Project II, commonly referred to as PIP II, is a linear accelerator overhaul at Fermilab to eventually double the output of its existing proton beam to continue to be the leading force in high energy physics. The proton beam is created through a series of high frequency cryomodules that must be connected utilizing a combination of magnets and vacuum pumps to ensure the beam is properly aligned. A housing mechanism for the magnets and vacuum pumps (Warm Units) will be placed between the cryomodules for realignment and require multiple stages of 6 degree-of-freedom adjustment options, to ensure that the beam alignment can fit all realistic requirements. Extensive testing and design modifications on the Warm Unit stand was completed to confirm not only the strength of the unit in nominal configuration, but also at each possible adjustment orientation for each 6 degree-of-freedom option. Structural analysis was also completed for various unique loading conditions i ncluding transportation loading and confirming the unit satisfies international building code. Simultaneously, testing and design modifications were done to confirm that the frequency modes of the system resided outside of concern ranges, which is determined by Fermilab safety codes and is set to exceed 15 Hz. Design changes that simultaneously stiffen the system to raise the lowest frequency modes while expanding access for technicians and allow for easier fabrication were developed and implemented into the Warm Unit stand. Various relationships between the design changes and the overall vibrational patterns were also developed for future use and study as the rest of PIP II matures.

43 PARTICLE ACCELERATORS↗

ArborX

ArborX library tackles a problem of efficiently finding geometric objects that are close in space. Variations of this problem, such as finding the nearest neighbors of a point, or finding all objects within a certain distance, are inherent components of applications in many fields. The data may be large so that solving the problem efficiently may require significant computational resources, such as multiple processors or accelerators such as general purpose GPUs. ArborX' main advantage in its ability to solve large problems efficiently utilizing a combination of distributed and on-node parallelism. ArborX can be run efficiently on a wide variety of hardware, including GPUs from different vendors, which distinguishes it from other available libraries which typically choose only few of these. The other advantage is that it supports both types of user problems: spatial problems (useful for intersections and finding objects within certain distance), and nearest neighbor problems. ArborX also supports flexible interface in its interaction with a user. Particularly, it allows a user to call user's own function on a positive match, a functionality not rarely available in other libraries. ArborX implements construction and traversal algorithms using efficient tree structures, such as bounding volume hierarchy (BVH). At its core, it uses linear BVH for its low construction cost and sufficient quality. ArborX is written using C++, and is parallelized using the message passing interface (MPI) for the distributed communication, and the Kokkos library for on-node parallelism. This approach allows ArborX to be run on a wide variety of hardware, from common laptops and desktops to supercomputers while using the same codebase. ArborX also implements several advanced algorithms using geometric search, such as density-based clustering algorithm DBSCAN.

ECP↗

ArborX 2.0

ArborX library tackles a problem of efficiently finding geometric objects that are close in space. Variations of this problem, such as finding the nearest neighbors of a point, or finding all objects within a certain distance, are inherent components of applications in many fields. The data may be large so that solving the problem efficiently may require significant computational resources, such as multiple processors or accelerators such as general purpose GPUs. ArborX' main advantage in its ability to solve large problems efficiently utilizing a combination of distributed and on-node parallelism. ArborX can be run efficiently on a wide variety of hardware, including GPUs from different vendors, which distinguishes it from other available libraries which typically choose only few of these. The other advantage is that it supports both types of user problems: spatial problems (useful for intersections and finding objects within certain distance), and nearest neighbor problems. ArborX also supports flexible interface in its interaction with a user. Particularly, it allows a user to call user's own function on a positive match, a functionality not rarely available in other libraries. ArborX implements construction and traversal algorithms using efficient tree structures, such as bounding volume hierarchy (BVH). At its core, ArborX uses linear BVH for its low construction cost and sufficient quality. ArborX implements both spatial and nearest-neighbor traversal algorithms. ArborX also provides several clustering algorithms (minimum spanning tree, DBSCAN, HDBSCAN*), interpolation using minimum least squares and ray tracing. ArborX is written using C++, and is parallelized using the message passing interface (MPI) for the distributed communication, and the Kokkos library for on-node parallelism. This approach allows ArborX to be run on a wide variety of hardware, from common laptops and desktops to supercomputers while using the same codebase.

Prokopenko, Andrey [Oak Ridge National Laboratory ↗

Microbeam studies of the sensitivity of structures within living cells

Determining the biological effects of low doses of radiation with high linear energy transfer (LET) is complicated by the stochastic nature of charged-particle interactions. Populations of cells exposed to very low radiation doses contain a few cells which have been hit by a charged particle, while the majority of the cells receive no radiation damage. At somewhat higher doses, a few cells receive two or more events. Because the effects of damage produced by separate events can interact in the cell, we have had to make assumptions about the nature of these interactions in order to interpret the results of the experiments. Many of those assumptions can be tested if we can be sure of the number of charged-particle events which occur in individual cells, and correlate this number with the biological effect. We have developed a special irradiation facility at Pacific Northwest Laboratory (PNL) to control the actual number of charged particle tracks that pass through cell nuclei. The beam from a 2 MeV tandem accelerator is collimated to approximately 5 microns. Cells, grown in special dishes with 1.5 microns thick plastic bottoms, are positioned so that the desired portion of the cell aligns with the collimator. A shutter in the beam line is opened and closed after the desired number of particle tracks has been counted. This approach can be used to investigate the effects of the interaction between irradiated and unirradiated cells in an organized system, as well as to study the effects of spatial and temporal distribution of radiation damage within single cells.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Electro-Optic Modulation Using Metal-Free Perovskites

Electro-optic (EO) modulation is of interest to impart information onto an optical carrier. Inorganic crystals—most notably LiNbO 3 and BaTiO 3 —exhibit EO modulation and good stability, but are difficult to integrate with silicon photonic technology. Solution-processed organic EO materials are readily integrated but suffer from thermal degradation at the temperatures required in operating conditions for accelerated reliability studies. Hybrid organic–inorganic metal halide perovskites have the potential to overcome these limitations; however, these have so far relied on heavy metals such as lead and cadmium. Here, we report linear EO modulation using metal-free perovskites, which maintain the crystalline features of the inorganic EO materials and incorporate the flexible functionality of organic EO chromophores. We find that, by introducing a deficiency of cations, we reduce the symmetry in the perovskite crystal and produce thereby an increased EO response. The best-engineered perovskites reported herein showcase an EO coefficient of 14 pm V –1 at a modulation frequency of 80 kHz, an order of magnitude higher than in the nondefective materials. Furthermore, we observe split peaks in the X-ray diffraction and neutron diffraction patterns of the defective sample, indicating that the crystalline structure has been distorted and the symmetry reduced. Density functional theory (DFT) studies link this decreased symmetry to NH 4 + deficiencies. This demonstration of EO from metal-free perovskites highlights their potential in next-generation optical information transmission.

36 MATERIALS SCIENCE↗

Freja Studies of the Current-Voltage Relation in Substorm-Related Events

Field-aligned currents and electrostatic potentials play important roles in the coupling between the magnetosphere and the ionosphere. If one assumes that the ionosphere-magnetosphere potential difference is mainly due to the mirror force, one can use the single particle adiabatic kinetic theory to describe the system. From this theory, a linear relationship j(sub II) = KV between field-aligned current density j(sub II) and potential drop V along the same field line can be derived, provided that the potential drop is not too large and not too small. With rare exceptions, observational tests of this relation have mainly concentrated on quiet magnetospheric situations, with acceleration voltages V approx. less than 5 kV. Here we use observations from the Freja satellite of precipitating auroral electrons at 1.700 km altitude to study substorm related events, with acceleration voltages up to 20 keV. The observations are found to be consistent with a linear current-voltage relation even i n these conditions, although with values of the field aligned K lower than previously reported (1-5 x 10(exp 11 S/sq m). This can be explained by lower densities and higher characteristic electron energies in the magnetospheric source region of the precipitating electrons. We analyze the data by three different methods, which are all found to be in general agreement. The results are in agreement with a previous study, where the spectra of precipitating electrons --were indirectly inferred by inversion of data from the EISCAT incoherent scatter radar, thereby validating the use of radar data for studies of auroral electrons. Comparisons with previous studies are made, emphasizing the dependence of the results on the type of auroral structure and magnetospheric conditions.

Olsson, A.↗

Designing Cyclic Nitrogen‐Bridged Sulfonamides with Anti‐Cancer Activity

The N-bridgehead heterocyclic structure is an abundant motif in a multitude of natural products. This structural feature is of high interest because it is present in many different bioactive molecules, many of which are well-established pharmaceuticals. The introduction of a sulfone group into the N-bridgehead system yields a new core structure containing a N-bridgehead sulfonamide. While linear sulfonamides can be found in natural products, only artificial cyclic sulfonamides are known to date. Applications of related cyclic sulfonamide compounds include matrix metalloproteinase inhibitors, potential HIV and cancer therapeutics, and anti-inflammatory compounds. To explore the potential bioactivity of the N-bridgehead sulfonamide scaffold, a synthetic route toward these scaffolds is developed and their bioactivity is explored against different cancer cell lines.

60 APPLIED LIFE SCIENCES↗

High-Gradient Tests of the Single-Cell SC Cavity with a Feedback Waveguide

Use of a superconducting (SC) traveling-wave accelerating (STWA) structure with a small phase advance per cell, rather than a standing-wave structure, may provide a significant increase in the accelerating gradient in the ILC linac [1]. For the same surface electric and magnetic fields, the STWA achieves an accelerating gradient 1.2 larger than TESLA-like standing-wave cavities. In addition, the STWA allows longer acceleration cavities, reducing the number of gaps between them. However, the STWA structure requires a SC feedback waveguide to return the few hundreds of MW of circulating RF power from the structure output to the structure input. A test single-cell cavity with feedback was designed and manufactured to demonstrate the possibility of proper processing to achieve a high accelerating gradient. The first results of high-gradient tests of a prototype 1.3 GHz single-cell cavity with feedback waveguide will be presented.

43 PARTICLE ACCELERATORS↗

Biased deposition of Nb-ON-Cu for SRF accelerators, Final Report

The Phase I project objectives were: Task 1: Design, assemble, and commission a new coating facility that uses the RF cavity as the vacuum chamber Task 3: Coat and RF test biased Cu cavity Task 4: Evaluate test results and prepare Ph-II bid. As for project accomplishments, AASC has completed all of the tasks of Ph-I. However, for Task 2, we found a limit to the bias voltage on a substrate placed at the radius of the beam pipe. A bias voltage higher than -50 V can induce arcing from the substrate to the grounded anode. Arc spots form on the substrate and damage the film. The main problem addressed by this SBIR project is that the price of niobium dominates the cost of superconducting RF cavity production. The most effective route to significant cost reduction is to use cavities that have a thin layer of niobium deposited on a less expensive substrate. However, all attempts to use thin films of niobium in superconducting RF cavities have to date resulted in cavity performance that does not meet the requirements of modern linear accelerators. Alameda Applied Sciences Corporation (AASC) has developed a novel deposition method that can produce high-purity films of niobium. For superconducting radio-frequency (SRF) accelerator cavities, films of niobium on another base material could provide good performance at lower cost than for bulk niobium. The primary goal of all thin film coated approaches must be to demonstrate RF performance that matches that of bulk Nb cavities. This Ph-I was not expected to accomplish this major milestone for thin film coated SRF cavities in just 9 months with limited resources. We set less ambitious goals of demonstrating that using our CED process to coat a biased substrate could result in an increase of RF performance over previous tests with no applied bias voltage. In this Ph-1, we obtained preliminary RF data from Nb coated biased cavity structures so as to move ahead in Ph-II to demonstration of performance that approaches that of bulk Nb. Our task has been made more daunting recently as several labs (Fermilab, Cornell, and JLab) have demonstrated significantly improved performance of bulk Nb cavities using nitrogen doping and rapid cool-down techniques. The bar has just been raised for thin films. At the 2013 SRF thin film workshop held at INFN in Padua Italy, leading scientists from the LHC tossed a gauntlet to the thin film community. The LHC plans a high luminosity upgrade starting in about 4 years. Upper management at CERN has stated that they would prefer not to use bulk Nb for the upgrade, which will require hundreds of new SRF cavities. But the thin film community has a short window in which to demonstrate that a Cu (or Al) cavity that is coated with Nb delivers the kind of performance that we have come to expect from bulk Nb: Q o >10 10 that stays flat up to 20 MV/m or higher, good statistics from multiple cavities and reliable operation over thousands of hours. Breakthroughs are needed to meet these daunting goals. AASC has persisted with this challenge for more than five years now, with the benefit of DOE SBIR funding. We aim to preserve our momentum and build upon our base to try to reach the lofty goals within four more years.

36 MATERIALS SCIENCE↗