Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

The behavior of magnitude dependent systematic errors

The objective grating technique is discussed. From the investigation of actual material, it is established that the effect of coma varies significantly from plate to plate, also that a model linear in diameter and/or coordinate may be inadequate for its removal, and even introduce systematic errors. From this standpoint, the requirements of reference star systems are discussed.

Eichhorn, H.↗

On the choice of reference orbitals for linear-response calculations of solution-phase K-edge X-ray absorption spectra

The simplest response theory methods for computing vertical excitation spectra in condensed-phase are configuration interaction with single excitations (CIS) and linear-response time-dependent density functional theory (TDDFT) within the Tamm–Dancoff approximation. In applications to X-ray absorption spectroscopy (XAS), methods like CIS and TDDFT that codify only single excitations into the wave function are prone to catastrophic errors in main-edge and post-edge features whose shapes act as a crucial fingerprint in structural analyses of liquids. Here, we show that these errors manifest primarily due to a lack of orbital relaxation in conventional linear-response theories and that core-ionized (n - 1-electron) references, like those of electron-affinity TDDFT, can eliminate the errors in the spectral profile, even in the highest-energy parts of the post-edge. Crucially, we find that single excitations atop core-ionized references are sufficient to elucidate liquid-phase XAS spectra with semi-quantitative accuracy, opening the door for methods like electron-affinity CIS/TDDFT to be used as efficient alternatives to higher-order wave function approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relative-Error-Covariance Algorithms

Two algorithms compute error covariance of difference between optimal estimates, based on data acquired during overlapping or disjoint intervals, of state of discrete linear system. Provides quantitative measure of mutual consistency or inconsistency of estimates of states. Relative-error-covariance concept applied, to determine degree of correlation between trajectories calculated from two overlapping sets of measurements and construct real-time test of consistency of state estimates based upon recently acquired data.

Bierman, Gerald J.↗

Performance analysis of an integrated GPS/inertial attitude determination system

The performance of an integrated GPS/inertial attitude determination system is investigated using a linear covariance analysis. The principles of GPS interferometry are reviewed, and the major error sources of both interferometers and gyroscopes are discussed and modeled. A new figure of merit, attitude dilution of precision (ADOP), is defined for two possible GPS attitude determination methods, namely single difference and double difference interferometry. Based on this figure of merit, a satellite selection scheme is proposed. The performance of the integrated GPS/inertial attitude determination system is determined using a linear covariance analysis. Based on this analysis, it is concluded that the baseline errors (i.e., knowledge of the GPS interferometer baseline relative to the vehicle coordinate system) are the limiting factor in system performance. By reducing baseline errors, it should be possible to use lower quality gyroscopes without significantly reducing performance. For the cases considered, single difference interferometry is only marginally better than double difference interferometry. Finally, the performance of the system is found to be relatively insensitive to the satellite selection technique.

Sullivan, Wendy I.↗

Robustness of linear quadratic state feedback designs in the presence of system uncertainty

The paper deals with the problem of expressing the robustness (stability) property of a linear quadratic state feedback (LQSF) design quantitatively in terms of bounds on the perturbations (modeling errors or parameter variations) in the system matrices so that the closed-loop system remains stable. Nonlinear time-varying and linear time-invariant perturbations are considered. The only computation required in obtaining a measure of the robustness of an LQSF design is to determine the eigenvalues of two symmetric matrices determined when solving the algebraic Riccati equation corresponding to the LQSF design problem. Results are applied to a complex dynamic system consisting of the flare control of a STOL aircraft. The design of the flare control is formulated as an LQSF tracking problem.

Patel, R. V.↗

SU-E-T-140: Dynamic Wave Arc Trajectory Verification Using KV X-Ray Fluoroscopy

Purpose: Purpose: This study investigates the geometric accuracy of simultaneous Gantry/Ring rotation during Dynamic Wave Arc (DWA) delivery. Methods: The Vero SBRT system consists of a 6MV LINAC mounted on an O-ring gantry that can rotate around the vertical axis (±60°), similar to couch rotation on C-arm gantries. To provide CBCT and fluoroscopy imaging functionalities, two orthogonal kV imaging units are attached to the O-ring at −45°/+45° from the beam axis.Dynamic Wave Arc maximizes Vero's motion capabilities by employing synchronized gantry and ring motion on a complex non-coplanar trajectory in combination with aperture based optimized MLC segments.Four wave arc trajectories (T1-4) were delivered using a cubic phantom with a configuration of five lead beads. O-ring gantry position information was retrieved through continuous dual-source kV X-ray image acquisition during DWA. An in-house algorithm read in the image set, extracted the projected marker positions and determined the angulation through reconstruction of the beam source position. The geometric error was quantified as the distance between the independently detected positions from kV-images and reference trajectory derived from the treatment plan in the Ring-Gantry space. Results: The average displacement between the 3D gantry/ring positions reconstructed from the fluoroscopy images and the reference trajectory was 0.346 mm (SD 0,171) for T1. A mean offset of 0.348 mm (SD 0,182) and 0.357 mm (SD 0.194) was observed for trajectory T2(2segmens) and T3(4segments), respectively. The saw shape T4 presented a mean geometric error of 0.363 (SD 0.156). The overall systematic error of 0.350 was caused by the difference between planned reference trajectory created by linear interpolation between CP, and the machine delivery following a spline curve. Conclusion: An independent geometric QA approach has been developed for DWA delivery verification, successfully applied on diverse trajectories and disclosed that the Vero system is capable of accurately follow complex trajectories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ab initio O(N) elongation-counterpoise method for BSSE-corrected interaction energy analyses in biosystems

An Elongation-counterpoise (ELG-CP) method was developed for performing accurate and efficient interaction energy analysis and correcting the basis set superposition error (BSSE) in biosystems. The method was achieved by combining our developed ab initio O(N) elongation method with the conventional counterpoise method proposed for solving the BSSE problem. As a test, the ELG-CP method was applied to the analysis of the DNAs’ inter-strands interaction energies with respect to the alkylation-induced base pair mismatch phenomenon that causes a transition from G⋯C to A⋯T. It was found that the ELG-CP method showed high efficiency (nearly linear-scaling) and high accuracy with a negligibly small energy error in the total energy calculations (in the order of 10{sup −7}–10{sup −8} hartree/atom) as compared with the conventional method during the counterpoise treatment. Furthermore, the magnitude of the BSSE was found to be ca. −290 kcal/mol for the calculation of a DNA model with 21 base pairs. This emphasizes the importance of BSSE correction when a limited size basis set is used to study the DNA models and compare small energy differences between them. In this work, we quantitatively estimated the inter-strands interaction energy for each possible step in the transition process from G⋯C to A⋯T by the ELG-CP method. It was found that the base pair replacement in the process only affects the interaction energy for a limited area around the mismatch position with a few adjacent base pairs. From the interaction energy point of view, our results showed that a base pair sliding mechanism possibly occurs after the alkylation of guanine to gain the maximum possible number of hydrogen bonds between the bases. In addition, the steps leading to the A⋯T replacement accompanied with replications were found to be unfavorable processes corresponding to ca. 10 kcal/mol loss in stabilization energy. The present study indicated that the ELG-CP method is promising for performing effective interaction energy analyses in biosystems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration and Data Analysis Recommendations for Three-Component Moment Balances

Fundamental characteristics of design, calibration, and application of three-component moment balances are investigated in great detail. These balances are typically used to determine loads on control surfaces, canards, or other parts that are attached to a wind tunnel model. First, three different descriptions of the load state of a moment balance are reviewed. Then, load transformations between different load formats and the combined load diagram for two of the three load components are discussed. An error analysis showed that it is critical to maximize the product of the distance between the bending moment gages and their sensitivities in order to minimize the overall error in the normal force prediction. In addition, it is important to apply a sufficient number of calibration loadings near the first bending moment gage. Then, unwanted near-linear dependencies between the two bending moment gage outputs can be avoided. The error in the bending moment prediction is also investigated that results from the elastic deformation of the metric part of the balance under load. Finally, the application of the Non-Iterative Method to three-component moment balance calibration data is described in order to obtain regression models that can be used to predict loads from measured outputs during a wind tunnel test.

Strain-Gage Balance↗

Adsorption of terbium (III) on DGA and LN resins: Thermodynamics, isotherms, and kinetics

Two commercially available extraction chromatography (EXC) resins containing N,N,N’,N’-tetra-n-octyldiglycolamide (DGA Resin, Normal, 50 – 100 μm) and Bis(2-ethylhexyl) phosphate (LN Resin, 100 – 150 μm) were used as adsorbents to study fundamental adsorption properties such as thermodynamic values, equilibrium isotherms, and kinetic uptake models for terbium(III) adsorption. Weight distribution ratios (D w ) for terbium on DGA and LN resins were measured using a [ 160 Tb]Tb 3+ radiometric tracer in nitric acid as a function of acidity, temperature, initial analyte concentration, and equilibrium time. The D w values showed increasing binding affinity for DGA resin at high nitric acid concentrations and decreasing binding affinity for LN resins. Thermodynamic studies for DGA and LN resins revealed that the Gibbs free energy (ΔG) increased consistently with temperature. To model equilibrium data, increasingly higher parameter equilibrium isotherm models (Henry (1) < Langmuir, Freundlich (2) < Redlich-Peterson (3) < Fritz-Schluender (4)) were compared on their root mean squared errors (RMSE) and adjusted determination coefficients to determine the most applicable model. In all cases, the empirical four-parameter Fritz-Schluender isotherm demonstrated a superior fit. Similar comparisons for reaction-based kinetic models (Pseudo-first-order < Pseudo-second-order < Pseudo-n-order) revealed that the higher-order PNO model yielded a superior fit of kinetic data for both resins. Furthermore, in some cases, adsorption isotherms and kinetic models could also be modeled by a lower-order model with minimal change in error parameters. Weber-Morris plots revealed that two linear sections are observed for each resin, where the first linear segment is attributed to fast (film diffusion) adsorption of terbium, followed by slower intraparticle diffusion of terbium through the pores as the rate-limiting step. Based on the Weber-Morris plot, both film and intraparticle diffusion are involved in controlling the kinetic rate of adsorption for DGA and LN resins.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Impact of electron density on the fixed-node errors in Quantum Monte Carlo of atomic systems

We analyze the effect of increasing charge density on the fixed-node errors in diffusion Monte Carlo (FNDMC). We compare FNDMC ground state energies of 4-electron atomic systems with nuclear charge using Hartree–Fock and restricted Configuration Interaction trial wave functions. We perform these calculations for several different values of the nuclear charge, and we analyze the systematic trends of the recovered correlation energies as a function of . For this testing system we demonstrate that the fixed-node error of the Hartree–Fock trial wave functions increases linearly with increasing the nuclear charge.

Chemistry↗

Treecode-based generalized Born method

We have developed a treecode-based O(N log N) algorithm for the generalized Born (GB) implicit solvation model. Our treecode-based GB (tGB) is based on the GBr6 [J. Phys. Chem. B 111, 3055 (2007)], an analytical GB method with a pairwise descreening approximation for the R6 volume integral expression. The algorithm is composed of a cutoff scheme for the effective Born radii calculation, and a treecode implementation of the GB charge–charge pair interactions. Test results demonstrate that the tGB algorithm can reproduce the vdW surface based Poisson solvation energy with an average relative error less than 0.6% while providing an almost linear-scaling calculation for a representative set of 25 proteins with different sizes (from 2815 atoms to 65456 atoms). For a typical system of 10k atoms, the tGB calculation is three times faster than the direct summation as implemented in the original GBr6 model. Thus, our tGB method provides an efficient way for performing implicit solvent GB simulations of larger biomolecular systems at longer time scales.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization and calibration of compact array spectrometers in the ultraviolet spectral region

Array-based spectrometers, with their compact size, low weight, low cost, and fast measurement time, are now frequently used in place of both conventional single-channel scanning monochromators, and broadband meters. Their rapid measurement capability makes them an attractive option for routine solar UV spectral measurements, where shortterm variability in signal is a challenge. However, compactness, portability, low cost and high speed are achieved at the expense of the spectrometer's optical and electronic performance. Thus such spectrometers are more prone to measurement error from environmental changes, and more prone to other intrinsic sources of error such as stray light and detector non-linearity, which significantly affect solar UV measurements, than a scanning monochromator. The effects of stray light and non-linearity can be reduced either by improved optical and detector design or by a detailed spectrometer characterization. We present in this paper our investigation of the performance of three different commercial array spectrometers: two mini-spectrometers, and a more elaborate array spectrometer with an on-board image amplifier device. These were tested for a subset of performance parameters: their wavelength accuracy and stability, electronic linearity, responsivity linearity, stray light sensitivity, and mechanical stability and repeatability. With all three spectrometers we found that these parameters, particularly but not limited to stray light, had a significant impact on the measurement of the incoming optical radiation. This meant that, without characterization, the instruments would be unable to accurately measure the UV component of any source with significant visible radiation. We discuss various simple and low-cost solutions for improving the performance of these instruments, and providing a rigorous calibration using a straightforward set-up including optical filters and the quasi-monochromatic light from a double monochromator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overlapped embedded fragment stochastic density functional theory for covalently-bonded materials

The stochastic density functional theory (DFT) is a valuable linear-scaling approach to Kohn-Sham DFT that does not rely on the sparsity of the density matrix. Linear (and often sub-linear) scaling is achieved by introducing a controlled statistical error in the density, energy, and forces. The statistical error (noise) is proportional to the inverse square root of the number of stochastic orbitals and thus decreases slowly; however, by dividing the system into fragments that are embedded stochastically, the statistical error can be reduced significantly. This has been shown to provide remarkable results for non-covalently-bonded systems; however, the application to covalently bonded systems had limited success, particularly for delocalized electrons. Here, we show that the statistical error in the density correlates with both the density and the density matrix of the system and propose a new fragmentation scheme that elegantly interpolates between overlapped fragments. In conclusion, we assess the performance of the approach for bulk silicon of varying supercell sizes (up to N e = 16 384 electrons) and show that overlapped fragments reduce significantly the statistical noise even for systems with a delocalized density matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Algorithmic Advancements for High-Order Self-Gravitating Hydrodynamics

Self-gravity plays a key role in the formation and evolution of many astronomical objects. Though gravity is often dominant at large scales, other forces (e.g., gas pressure gradients, radiation, and/or magnetic fields) often compete. It is therefore essential for numerical simulations to evaluate their interplay accurately and robustly. Hanawa & Mullen derived a 4th-order accurate finite volume scheme to solve the equations of self-gravitating hydrodynamics on a uniform Cartesian grid. In this work, we supply improvements to the algorithm that (1) mitigate spurious gravitational circulation and (2) greatly simplify the evaluation of the high order corrections. The proposed algorithm provides the gravitational acceleration (ρg) and the gravitational energy release (ρv · g) as source terms for the hydrodynamic equations, all while preserving conservation of linear momentum. Spurious heating and/or cooling associated with truncation error in the numerical evaluation of the gravitational energy release decreases in proportion to the fourth power of the cell width. We demonstrate fourth order convergence on smooth problems (e.g., 3D inclined sound wave propagation and 3D equilibria). An application test tracks the spherical collapse of a polytrope by an imposed, sudden decrease of the central gas pressure; a bounce and second collapse (associated with a spherical accretion shock) are robustly captured by the high order algorithm.

79 ASTRONOMY AND ASTROPHYSICS↗

Radon Kinetics in a Basement Space Measured with Different Devices

Although indoor monitoring of radon and benchmarking of radon measurement devices remain important research topics, few intercomparisons of active radon measurement devices have been performed under realistic conditions, let alone dynamic ones enabling comparison of their transient behavior. Five different radon monitors were therefore placed in a poorly ventilated basement space under three different conditions: 24 h under a steady, elevated radon level, 24 h with fans turned on to produce a radon washout transient, and 9 d with fans turned off for a radon buildup transient. Resulting radon concentrations varied between ~200 and ~2,000 Bq m -3 . Accuracy of the devices were evaluated using root-mean-square error, and ventilation data were fit to first order linear compartmental models. To more accurately model behaviors such as cyclic diurnal variations, the source term corresponding to entry of radon from soil into the basement was considered to be non-constant, as it is likely to vary drastically with both the indoor-outdoor pressure differential and soil concentration variations. Here, the improved radon washout model fit very well with the measurements. Despite a wide variety in list prices, all devices performed similarly during transients and at different radon concentrations.

60 APPLIED LIFE SCIENCES↗

Exploration of the polarization angle variability of the Crab Nebula with POLARBEAR and its application to the search for axionlike particles

The Crab Nebula, also known as Tau A, is a polarized astronomical source at millimeter wavelengths. It has been used as a stable light source for polarization angle calibration in millimeter-wave astronomy. However, it is known that its intensity and polarization vary as a function of time at a variety of wavelengths. Thus, it is of interest to verify the stability of the millimeter-wave polarization. If detected, polarization variability may be used to better understand the dynamics of Tau A, and for understanding the validity of Tau A as a calibrator. One intriguing application of such observation is to use it for the search of axionlike particles (ALPs). Ultralight ALPs couple to photons through a Chern-Simons term, and induce a temporal oscillation in the polarization angle of linearly polarized sources. After assessing a number of systematic errors and testing for internal consistency, we evaluate the variability of the polarization angle of the Crab Nebula using 2015 and 2016 observations with the 150 GHz P instrument. We place a median 95% upper bound of polarization oscillation amplitude A < 0.06 5 ° over the oscillation frequencies from 0.75 year − 1 to 0.66 hour − 1 . Assuming that no sources other than ALP are causing Tau A’s polarization angle variation, that the ALP constitutes all the dark matter, and that the ALP field is a stochastic Gaussian field, this bound translates into a median 95% upper bound of ALP-photon coupling g a γ γ < 2.16 × 10 − 12 GeV − 1 × ( m a / 10 − 21 eV ) in the mass range from 9.9 × 10 − 23 eV to 7.7 × 10 − 19 eV . This demonstrates that this type of analysis using bright polarized sources is as competitive as those using the polarization of cosmic microwave background in constraining ALPs. Published by the American Physical Society 2024

Adachi, Shunsuke (ORCID:0000000204007555)↗

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond 10 4 . However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, in this work, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from 𝑛 pulses applied from alternating directions scales linearly with 𝑛. This is a significant advantage over the 𝑛 2 scaling that occurs when probing a two-level system 𝑛 times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.

Mach-Zehnder atom interferometry↗

Glass Additive and Subtractive Manufacturing of a Fiber Optic Rotary Encoder for Downhole Pressure Sensing

This article presents a fiber optic rotary encoder-based pressure sensor for downhole applications. The rotary encoder, which is composed of an encoding pad and an all-glass optical fiber sensing head, converts the rotation angles of a pressure transducer to digital codes. The optical fiber only serves as the telemetry channel to directly transmit the data in digital format such that the environmental temperature influence and the long-time drift are minimized. The glass additive and subtractive manufacturing (ASM) techniques are used to embed the multichannel optical fibers into a bulk-fused silica glass substrate. Because the fused silica glass shares a similar material property to the optical fiber (e.g., thermal expansion coefficient), the optical fiber sensing head is well sealed and fixed even at an elevated temperature. The picosecond laser blackening technique is used to fabricate the high reflectivity contrast encoding pad with high accuracy. Here, the proposed pressure sensor was manufactured and experimentally verified to have a signal-to-noise ratio (SNR) of 23 dB and a linear pressure response with a root-mean-square error (RMSE) of 0.37. During the 400-h 250 °C long-term stability test, there was no digital code variation. In addition, a mathematical model to study the relationships between the sensor’s performances and design parameters was established. According to the model, a 12-bit encoder (0.02% pressure sensitivity) can be achieved with a radius of 20 mm.

02 PETROLEUM↗