Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A Disruptive Approach to Electric Vehicle Power Electronics Final Report

This project developed and demonstrated a new power electronics technology for electric vehicle drivetrains, that achieved significant improvements in power density and efficiency over standard drive cycles, relative to the commercial state of the art. In particular, the prototype measured loss and efficiency curves demonstrated a reduction in total loss over the US EPA US06 drive cycle by a factor of four. Similar reductions are observed for urban (UDDS) and highway (HWFET) drive cycles. Further, the project demonstrated a significant reduction in the total film capacitor requirements, by over an order of magnitude; this was achieved through fundamental improvements in converter circuit topologies. These nonincremental technology advances can lead to significant improvements in temperature rise, reliability, cost, and cooling system size and weight. These results were achieved through a new proposed composite converter architecture, and were demonstrated in a boost-type system similar to that employed by Toyota, Ford, and Honda. A 30 kW silicon prototype achieved a US06 average efficiency of 97.5%, which represents a reduction in average loss by a factor of approximately four relative to the 92.5% average efficiency of the commercial state of the art. A silicon carbide prototype achieved similar efficiency, while also achieving power densities of 23 kW/L (volumetric) and 20 kW/kg (gravimetric) in a boost dc-dc system including magnetics and film capacitors. This was achieved with a SiC switching frequency of 240 kHz, which allowed employment of planar magnetics. These power densities are roughly four times better than the commercial state of the art, and significantly exceed the DOE APEEM 2020 goals. In addition to the composite boost system, a SiC inverter was demonstrated at the 800 V 30 kW level. This inverter was demonstrated driving a permanent magnet machine over the US 06 drive cycle. The replacement of 1200 V Si IGBTs with 1200 V SiC MOSFETs led to improvement of CAFE average efficiency from 98.7% to 99.5%, which corresponds to a reduction of average loss by a factor of approximately two. The modular nature of the composite converter architecture opens the possibility of reuse of one or more converter modules during charging operations, providing a path for onboard charging capability at significant power levels while significantly reducing the volume and weight of the added charger module. This project demonstrated an integrated Level II charger whose add-on specific weight was approximately four times better than the DOE PHEV charger 2022 targets.

33 ADVANCED PROPULSION SYSTEMS↗

Ultrahigh-spatial-resolution chemical and magnetic imaging by laser-based photoemission electron microscopy

We report the first experiments carried out on a new chemical and magnetic imaging system, which combines the high spatial resolution of a photoemission electron microscope (PEEM) with a continuous-wave deep-ultraviolet laser. Threshold photoemission is sensitive to the chemical and magnetic structures of the surface of materials. The spatial resolution of PEEM is limited by space charging when using pulsed photon sources as well as aberrations in the electron optics. We show that the use of a continuous-wave laser enabled us to overcome such a limit by suppressing the space-charge effect, allowing us to obtain a resolution of approximately 2.6 nm. With this system, we demonstrated the imaging of surface reconstruction domains on Si(001) by linear dichroism with normal incidence of the laser beam. We also succeeded in magnetic imaging of thin films with the use of magnetic circular dichroism near the Fermi level. The unique features of the ultraviolet laser will give us fast switching of the incident angles and polarizations of the photon source, which will be useful for the characterization of antiferromagnetic materials as well as ferromagnetic materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of runaway electrons using the conditional average sampling method in the Damavand tokamak

Some experiments for studying the runaway electron (RE) effects have been performed using the poloidal magnetic probes system installed around the plasma column in the Damavand tokamak. In these experiments, the so-called runaway-dominated discharges were considered in which the main part of the plasma current is carried by REs. The induced magnetic effects on the poloidal pickup coils signals are observed simultaneously with the Parail–Pogutse instability moments for REs and hard X-ray bursts. The output signals of all diagnostic systems enter the data acquisition system with 2 Msample/(s channel) sampling rate. The temporal evolution of the diagnostic signals is analyzed by the conditional average sampling (CAS) technique. The CASed profiles indicate RE collisions with the high-field-side plasma facing components at the instability moments. The investigation has been carried out for two discharge modes—low-toroidal-field (LTF) and high-toroidal-field (HTF) ones—related to both up and down limits of the toroidal magnetic field in the Damavand tokamak and their comparison has shown that the RE confinement is better in HTF discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helium pressures in RHIC vacuum cryostats and relief valve requirements from magnet cooling line failure

A catastrophic failure of the RHIC magnet cooling lines, similar to the LHC superconducting bus failure incident, would pressurize the insulating vacuum in the magnet and transfer line cryostats. Insufficient relief valves on the cryostats could cause a structural failure. A SINDA/FLUINT{reg_sign} model, which simulated the 4.5K/4 atm helium flowing through the magnet cooling system distribution lines, then through a line break into the vacuum cryostat and discharging via the reliefs into the RHIC tunnel, had been developed to calculate the helium pressure inside the cryostat. Arc flash energy deposition and heat load from the ambient temperature cryostat surfaces were included in the simulations. Three typical areas: the sextant arc, the Triplet/DX/D0 magnets, and the injection area, had been analyzed. Existing relief valve sizes were reviewed to make sure that the maximum stresses, caused by the calculated maximum pressures inside the cryostats, did not exceed the allowable stresses, based on the ASME Code B31.3 and ANSYS results. The conclusions are as follows: (1) The S/F simulation results show that the highest internal pressure in the cryostats, due to the magnet line failure, is {approx}37 psig (255115 Pa); (2) Based on the simulation, the temperature on the cryostat chamber, INJ Q8-Q9, could drop to 228 K, which is lower than the material minimum design temperature allowed by the Code; (3) Based on the ASME Code and ANSYS results, the reliefs on all the cryostats inside the RHIC tunnel are adequate to protect the vacuum chambers when the magnet cooling lines fail; and (4) In addition to the pressure loading, the thermal deformations, due to the temperature decrease on the cryostat chambers, could also cause a high stress on the chamber, if not properly supported.

43 PARTICLE ACCELERATORS↗

Heat capacity and neutron diffraction studies on the frustrated magnetic Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} [0{<=}x{<=}1] solid solution

The Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} [0{<=}x{<=}1] solid solution exhibits a complex magnetic behaviour due to the bond-frustration in its magnetic structure. Heat capacity measurements of the (x=0.1-0.5) phases show a three-dimensional magnetic ordering ({lambda} anomaly) that shifts to lower temperatures and becomes broader as the AsO{sub 4}{sup 3-} content increases. For x=0.75, no significant feature was observed whereas for higher arsenate ion content, x=0.9 and 1, a small maximum was detected. The magnetic structures of solid solution are consistent with the existence of predominant antiferromagnetic superexchange interactions through the |OH| and |XO{sub 4}| (X=P and As) groups between the Co{sup +2} ions. The substitution of PO{sub 4}{sup 3-} by AsO{sub 4}{sup 3-} anions by more than 90% substantially modifies the magnetic exchange pathways in the solid solution, leading to an incommensurate antiferromagnetic structure in Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} [x=0.9 and 1] phases. - Graphical abstract: Magnetic structures of Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} [0{<=}x{<=}1]. The ordering of the magnetic moments of Co{sup 2+} is in c direction for the two crystallographic positions (dimers and chains) in all compounds. The unit cell is surrounded by a red line. Highlights: Black-Right-Pointing-Pointer Synthesis of a new adamite-type compounds, Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} (0.1, 0.25, 0.5, 0.75, 0.9) phases. Black-Right-Pointing-Pointer Co{sub 2}(OH)(PO{sub 4}){sub 1-x}(AsO{sub 4}){sub x} (0-1) solid solution; magnetic frustrated system. Black-Right-Pointing-Pointer High resolution neutron powder diffraction to determine the crystal structures. Black-Right-Pointing-Pointer Incommensurate magnetic structures at low temperature. Black-Right-Pointing-Pointer Magnetostructural correlations in cobalt-based Co{sub 2}(OH)XO{sub 4} (X=P and As) insulation compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Installation of a second superconducting wiggler at SAGA-LS

The SAGA Light Source is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring with a circumference of 75.6 m. A superconducting wiggler (SCW) with a peak magnetic field of 4 T has been routinely operating for generating hard X-rays since its installation in 2010. In light of this success, it was decided to install a second SCW as a part of the beamline construction by Sumitomo Electric Industries. To achieve this, machine modifications including installation of a new magnet power supply, improvement of the magnet control system, and replacement of the vacuum chambers in the storage ring were carried out. Along with beamline construction, installation and commissioning of the second SCW are scheduled to take place in 2015.

43 PARTICLE ACCELERATORS↗

Coexisting structural disorder and robust spin-polarization in half-metallic FeMnVAl

We report half-metallic ferromagnets (HMFs) are one of the most promising materials in the field of spintronics due to their unique band structure, consisting of one spin subband having metallic characteristics along with another subband with semiconductor-like behavior. In this work, we report the synthesis of a novel quaternary Heusler alloy—FeMnVAl—and we have studied the structural, magnetic, transport, and electronic properties complemented with first-principles calculations. Among different possible structurally ordered arrangements, the optimal structure is identified by theoretical energy minimization. The corresponding spin-polarized band-structure calculations indicate the presence of a half-metallic ferromagnetic ground state. A detailed and careful investigation of the x-ray diffraction data, Mössbauer spectra, and nuclear magnetic resonance spectra suggests the presence of site disorder between the Fe and Mn atoms in the stable ordered structure of the system. The magnetic susceptibility measurement clearly establishes a ferromagnetic-like transition below ~213 K. The Fe Mössbauer spectrometry measurements suggest that only the Mn spins could be responsible for the magnetic order, which is consistent with our theoretical calculation. Surprisingly, the density-functional-theory calculations reveal that the spin-polarization value is almost immunized (92.4% → 90.4%) from the Mn-Fe structural disorder, even when nonmagnetic Fe and moment-carrying Mn sites are entangled inseparably. The robustness of spin polarization and half-metallicity in the studied FeMnVAl compound comprising structural disorder is thus quite interesting and could provide a new direction to investigate and understand the exact role of disorders on spin polarization in this class of materials, beyond the available knowledge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Isodynamic axisymmetric equilibrium near the magnetic axis

Plasma equilibrium near the magnetic axis of an axisymmetric toroidal magnetic confinement system is described in orthogonal flux coordinates. For the case of a constant current density in the vicinity of the axis and magnetic surfaces with nearly circular cross sections, expressions for the poloidal and toroidal magnetic field components are obtained in these coordinates by using expansion in the reciprocal of the aspect ratio. These expressions allow one to easily derive relationships between quantities in an isodynamic equilibrium, in which the absolute value of the magnetic field is constant along the magnetic surface (Palumbo’s configuration)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory Study of the Equilibrium and Eruption of Line-Tied Magnetic Flux Ropes in the Solar Corona

Ideal magnetohydrodynamic (MHD) instabilities such as the kink instability and the torus instability are leading candidates to explain the sudden onset of eruptive events in the solar corona. These instabilities act on line-tied magnetic flux ropes--long-lived arched structures anchored to the solar surface. In spite of substantial observational and numerical research, however, the role of these instabilities in the corona remains a subject of intense debate. For this thesis, we have constructed and operated a new line-tied flux rope experiment that permits for the first time the study of both the kink and torus instabilities in the laboratory. This experiment has the following key features: (1) the arched flux rope is line-tied to two conducting footpoints; (2) the system is magnetically dominated (low-beta) with significant stored energy; (3) the system is driven quasi-statically, producing a long-lived equilibrium; and (4) the flux rope is generated within a potential (vacuum) magnetic field arcade whose decay index--the predicted torus instability control parameter--can be externally controlled. The flux ropes are diagnosed using a two-dimensional in situ magnetic probe array whose cross-section covers a substantial portion of the plasma. The central result of this thesis is that toroidal field forces, which are traditionally neglected in the analysis of coronal flux ropes, are identified for the first time as an essential contributor to both the equilibrium and the stability of line-tied flux ropes. Most importantly, experimental measurements show that a tension force derived from a self-generated paramagnetic toroidal field exerts a restoring force on the line-tied plasma and suppresses eruptive behavior in a significant portion of the parameter space. This suppression extends to regimes that are both kink and torus unstable. We find that, in order to explain the measured tension force, low aspect ratio and line-tying effects must be considered. Finally, flux rope eruptions are observed in these experiments, but only in regimes with sufficiently low external toroidal field where the tension force is reduced. These results constitute a new condition for the prediction of line-tied magnetic flux rope eruptions: that of low external toroidal field.

Magnetic Fields↗

Signature of quantum Griffiths singularity state in a layered quasi-one-dimensional superconductor

Quantum Griffiths singularity was theoretically proposed to interpret the phenomenon of divergent dynamical exponent in quantum phase transitions. It has been discovered experimentally in three-dimensional (3D) magnetic metal systems and two-dimensional (2D) superconductors. But, whether this state exists in lower dimensional systems remains elusive. Here, we report the signature of quantum Griffiths singularity state in quasi-one-dimensional (1D) Ta2PdS5 nanowires. The superconducting critical field shows a strong anisotropic behavior and a violation of the Pauli limit in a parallel magnetic field configuration. Current-voltage measurements exhibit hysteresis loops and a series of multiple voltage steps in transition to the normal state, indicating a quasi-1D nature of the superconductivity. Surprisingly, the nanowire undergoes a superconductor-metal transition when the magnetic field increases. Upon approaching the zero-temperature quantum critical point, the system uncovers the signature of the quantum Griffiths singularity state arising from enhanced quenched disorders, where the dynamical critical exponent becomes diverging rather than being constant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature and composition phase diagram in the iron-based ladder compounds Ba 1 - x Cs x Fe 2 Se 3

We investigated the iron-based ladder compounds (Ba,Cs)Fe₂Se₃. Their parent compounds BaFe₂Se₃ and CsFe₂Se₃ have different space groups, formal valences of Fe, and magnetic structures. Electrical resistivity, specific heat, magnetic susceptibility, x-ray diffraction, and powder neutron diffraction measurements were conducted to obtain a temperature and composition phase diagram of this system. Block magnetism observed in BaFe₂Se₃ is drastically suppressed with Cs doping. In contrast, stripe magnetism observed in CsFe₂Se₃ is not so fragile against Ba doping. A new type of magnetic structure appears in intermediate compositions, which is similar to stripe magnetism of CsFe₂Se₃, but interladder spin configuration is different. Intermediate compounds show insulating behavior, nevertheless a finite T-linear contribution in specific heat was obtained at low temperatures.

Hawai, Takafumi↗

First Field Quality Measurements of a 15 T Nb3Sn Dipole Demonstrator

Outline: Data collection; Magnetic Measurement System; Measurement sensitivity; Centering Corrections; Measurement discussion; Transfer Function (magnitude of the field); Loop (Dynamic effects, eddy current); Z-scan (behavior along magnet length); Harmonics from Stair Step (geometric harmonics); Comparison with Simulation; Decay and Snapback; Summary

43 PARTICLE ACCELERATORS↗

Magnetic interactions in a quasi-one-dimensional antiferromagnet Cu(H{sub 2}O){sub 2}(en)SO{sub 4}

A theoretical ab-initio investigation of exchange interaction between Cu atoms in an insulating antiferromagnet Cu(H{sub 2}O){sub 2}(en)SO{sub 4}, en = C{sub 2}H{sub 8}N{sub 2}, is reported. While the previous experimental studies described the system's magnetism to be quasi-two-dimensional, our results, based on a mapping of the system onto an effective Heisenberg model, rather support a quasi-one-dimensional character with the exchange coupling between the Cu atoms being propagated mainly along a zigzag line lying in the crystal's bc plane and connecting the Cu atoms through the N atoms. Further, the direction of magnetic moments on the Cu atoms is suggested to be nearly along the crystal's a axis. A check of the change in the exchange constants induced either by external pressure or by various values of U in the GGA + U approximation is made. Finally, based on experimental values of positions of broad maxima in magnetic-susceptibility and specific-heat curves and using theoretical expressions available in the literature a relevant value of the U parameter and related expected value of the electronic gap are estimated to be about 5 eV and 2 eV, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Signal enhancement using a switchable magnetic trap

A system for analyzing a sample including providing a microchannel flow channel; associating the sample with magnetic nanoparticles or magnetic polystyrene-coated beads; moving the sample with said magnetic nanoparticles or magnetic polystyrene-coated beads in the microchannel flow channel; holding the sample with the magnetic nanoparticles or magnetic polystyrene-coated beads in a magnetic trap in the microchannel flow channel; and analyzing the sample obtaining an enhanced analysis signal. An apparatus for analysis of a sample includes magnetic particles connected to the sample, a microchip, a flow channel in the microchip, a source of carrier fluid connected to the flow channel for moving the sample in the flow channel, an electromagnet trap connected to the flow line for selectively magnetically trapping the sample and the magnetic particles, and an analyzer for analyzing the sample.

47 OTHER INSTRUMENTATION↗

Fast IMRT with narrow high energy scanned photon beams

Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity beam spots resulting in a uniformity of collimated 80%-20% penumbra of 9 mm at a primary electron energy of 50 MeV. For the more complex cardioid shaped dose distribution, they used 270 spots, which at a pulse repetition frequency of 200 Hz is completed every 1.36 s. Conclusions: The present measurements indicate that the use of narrow scanned photon beams is a flexible and fast method to deliver advanced intensity modulated beams. Fast scanned photon IMRT should, therefore, be a very interesting modality in the delivery of biologically optimized radiation therapy with the possibility for in vivo treatment verification with PET-CT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Activities with the IELLLO Lithium-Lead Facility

Fusion power offers the prospect of an almost inexhaustible source of energy for future generations. Although this may be true, it also presents so far serious scientific and engineering challenges. Breeding Blanket is one of key components of future fusion reactors, since it directly involves tritium breeding and energy extraction, both of them critical to development of fusion power. To deal with the development of Breeding Blankets, ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development) designed and built a lead lithium loop (IELLLO: Integrated European Lead Lithium Loop): the experiment aims to support R and D activities for the conceptual and preliminary design of the European test blanket systems. IELLLO was completed, installed and operated at ENEA Brasimone Research Centre. The purpose of this work is to describe the experimental activities that have been carried out concerning the qualification of the facility, and relative instrumentations, for lead lithium applications. A series of thermo-hydraulic investigations on IELLLO facility has been elaborated: lead lithium pressure transducers, heat exchanger, permanent magnet pumping system, mass flow meters and air cooler have been tested. The absolute pressure meter in contact with Pb-16Li was qualified in pressure range up to 10 bar and temperature up to 400 deg. C. The installation of new kinds of Pb-16Li differential pressure transducers will allow to check the pump characteristic curve and accurately calculate valves pressure drops. These factors could give a better information for the thermo-hydraulic qualification of the facility. Vortex Mass Flow Meter has shown good results in terms of accuracy. The performance has been validated by thermal balance with a dedicated heating system. Nevertheless, the installations of different types of mass flow meters will enable to test IELLLO at ITER relevant conditions, and at lower mass flow rates than those tested up to now. The new pumping system with a PM Pump, was qualified for the first time in Pb-16Li, and the procedure for the operation and maintenance of the pump was developed. The pump is able to supply a mass flow rate in the range from 1.2 to 2.4 kg/s with a temperature of Pb-16Li up to 550 deg. C in the test section. Significant results have been obtained also for the heat exchanger, which has shown high efficiencies, even more than expected. Likewise, the Air Cooler has been verified to be able to cool Pb-16Li in a relatively short time, even at the worst temperature and mass flow conditions. (authors)

42 ENGINEERING↗

LOOKING FOR A PULSE: A SEARCH FOR ROTATIONALLY MODULATED RADIO EMISSION FROM THE HOT JUPITER, {tau} BOOeTIS b

Hot Jupiters have been proposed as a likely population of low-frequency radio sources due to electron cyclotron maser emission of similar nature to that detected from the auroral regions of magnetized solar system planets. Such emission will likely be confined to specific ranges of orbital/rotational phase due to a narrowly beamed radiation pattern. We report on GMRT 150 MHz radio observations of the hot Jupiter {tau} Booetis b, consisting of 40 hr carefully scheduled to maximize coverage of the planet's 79.5 hr orbital/rotational period in an effort to detect such rotationally modulated emission. The resulting image is the deepest yet published at these frequencies and leads to a 3{sigma} upper limit on the flux density from the planet of 1.2 mJy, two orders of magnitude lower than predictions derived from scaling laws based on solar system planetary radio emission. This represents the most stringent upper limits for both quiescent and rotationally modulated radio emission from a hot Jupiter yet achieved and suggests that either (1) the magnetic dipole moment of {tau} Booetis b is insufficient to generate the surface field strengths of >50 G required for detection at 150 MHz or (2) Earth lies outside the beaming pattern of the radio emission from the planet.

79 ASTRONOMY AND ASTROPHYSICS↗

Systems and methods for creation of conducting networks of magnetic particles through dynamic self-assembly process

Self-assembly of magnetic microparticles in AC magnetic fields. Excitation of the system by an AC magnetic field provides a variety of patterns that can be controlled by adjusting the frequency and the amplitude of the field. At low particle densities the low-frequency magnetic excitation favors cluster phase formation, while high frequency excitation favors chains and netlike structures. For denser configurations, an abrupt transition to the network phase was obtained.

36 MATERIALS SCIENCE↗