Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

TESTING OF NB{sub 3}SN QUADRUPOLE COILS USING MAGNETIC MIRROR STRUCTURE

This paper describes the design and parameters of a quadrupole mirror structure for testing the mechanical, thermal and quench performance of single shell-type superconducting quadrupole coils at field, current and force levels similar to that of real magnet. The concept was experimentally verified by testing two quadrupole coils, previously used in quadrupole models, in the developed mirror structure in the temperature range from 4.5 to 1.9 K. The coils were instrumented with voltage taps, heaters, and strain gauges to monitor their mechanical and thermal properties and quench performance. A new quadrupole coil made of improved Nb{sub 3}Sn RRP-108/127 strand and cable insulation based on E-glass tape was also tested using this structure. The fabrication and test results of the quadrupole mirror models are reported and discussed.

36 MATERIALS SCIENCE↗

Enabling resonant ultrasound spectroscopy in high magnetic fields

Resonant ultrasound spectroscopy (RUS) is a powerful method to determine elastic constants with high accuracy and precision from a single measurement of the mechanical resonances of a sample. Conventionally, the quantitative extraction of elastic moduli with RUS assumes free boundary conditions which can often lead to the adoption of unstable sample positioning between ultrasonic transducers that is incompatible with extreme environments like high magnetic fields. We show that, under specific conditions, introducing a small amount of adhesive between a RUS sample and ultrasonic transducers introduces a perturbation to the free resonance condition which can be accounted for by a simple model. This means elastic constants can be determined to within the uncertainty of conventional RUS, but with significant improvements including sample stability and control of sample orientation. We demonstrate the efficacy of this approach with measurements on a range of materials including room temperature measurements on polycrystalline metals, temperature-dependent measurements of the structural phase transition in strontium titanate single crystals, and magnetic field-dependent measurements of magnetic phase transitions in gadolinium polycrystals up to 14 T.

47 OTHER INSTRUMENTATION↗

The Magnetospheric Multiscale Constellation

The Magnetospheric Multiscale (MMS) mission is the fourth mission of the Solar Terrestrial Probe (STP) program of the National Aeronautics and Space Administration (NASA). The MMS mission was launched on March 12, 2015. The MMS mission consists of four identically instrumented spin-stabilized observatories which are flown in formation to perform the first definitive study of magnetic reconnection in space. The MMS mission was presented with numerous technical challenges, including the simultaneous construction and launch of four identical large spacecraft with 100 instruments total, stringent electromagnetic cleanliness requirements, closed-loop precision maneuvering and pointing of spinning flexible spacecraft, on-board GPS based orbit determination far above the GPS constellation, and a flight dynamics design that enables formation flying with separation distances as small as 10 km. This paper describes the overall mission design and presents an overview of the design, testing, and early on-orbit operation of the spacecraft systems and instrument suite.

Space mission design↗

Markov properties of the magnetic field in the quiet solar photosphere

The observed magnetic field on the solar surface is characterized by a very complex spatial and temporal behavior. Although feature-tracking algorithms have allowed us to deepen our understanding of this behavior, subjectivity plays an important role in the identification and tracking of such features. In this paper, we study the temporal stochasticity of the magnetic field on the solar surface without relying on either the concept of magnetic feature or on the subjective assumptions about their identification and interaction. The analysis is applied to observations of the magnetic field of the quiet solar photosphere carried out with the Imaging Magnetograph eXperiment (IMaX) instrument on board the stratospheric balloon, Sunrise. We show that the joint probability distribution functions of the longitudinal (B{sub ∥}) and transverse (B{sub ⊥}) components of the magnetic field, as well as of the magnetic pressure (B{sup 2}=B{sub ⊥}{sup 2}+B{sub ∥}{sup 2}), verify the necessary and sufficient condition for the Markov chains. Therefore, we establish that the magnetic field as seen by IMaX with a resolution of 0.″15–0.″18 and 33 s cadence, which can be considered as a memoryless temporal fluctuating quantity.

79 ASTRONOMY AND ASTROPHYSICS↗

Geodetic Investigations of the Mission Concept MAGIC to Reveal Callisto’s Internal Structure

Geodetic and geophysical investigations of the Galilean moon Callisto address fundamental questions regarding the formation and evolution of the Jovian system. Callisto's evolution and internal structure appear to significantly differ from the other Jovian satellites. Similarly-sized Ganymede is a highly evolved ice-rock moon with a differentiated interior, intrinsic magnetic field, and abundant surface evidence of internal activity. In contrast, Callisto's surface is ancient, and Galileo spacecraft data suggest its interior is only incompletely differentiated, despite the presumed presence of a sub-surface ocean. These properties make Callisto uniquely able to constrain the timing and nature of the Jovian system formation. The Magnetics, Altimetry, Gravity, and Imaging of Callisto (MAGIC) mission concept is conceived to fully characterize the properties of this enigmatic moon from its deep interior to the icy shell. Three main instruments are included as a scientific payload. Highly accurate measurements of Callisto's topography, magnetic field, and morphology are obtained by the onboard laser altimeter, magnetometer, and camera, respectively. The telecommunication system supports an additional gravity and radio science investigation. Long- and short-wavelength gravity anomalies afford powerful constraints on internal differentiation and the properties of the hydrosphere (water and ice). Comprehensive numerical simulations and covariance analyses of MAGIC mission scenarios presented in this paper show that the gravitational degree-2 normalized coefficients and the pole obliquity enable the determination of the moment of inertia with an accuracy better than 0.015%. The combination of gravity and altimetry measurements acquired by MAGIC are essential to the characterization of Callisto's interior if – as is likely – the degree-2 gravity includes non-hydrostatic terms. MAGIC's radio science data yield the estimation of Callisto's gravity field with spatial resolutions of <100 km. The combination of gravitational and deformation tides that are retrieved by the radio science and altimetry investigations, respectively, leads to the recovery of the rigid ice shell thickness to within ∼3 km. Together these datasets would resolve ambiguities inherent in Galileo flyby data, revealing Callisto's interior structure as well as the existence and properties of its postulated internal ocean.

Antonio Genova↗

LabVIEW-based control software for para-hydrogen induced polarization instrumentation

The elucidation of cell metabolic mechanisms is the modern underpinning of the diagnosis, treatment, and in some cases the prevention of disease. Para-Hydrogen induced polarization (PHIP) enhances magnetic resonance imaging (MRI) signals over 10 000 fold, allowing for the MRI of cell metabolic mechanisms. This signal enhancement is the result of hyperpolarizing endogenous substances used as contrast agents during imaging. PHIP instrumentation hyperpolarizes Carbon-13 ({sup 13}C) based substances using a process requiring control of a number of factors: chemical reaction timing, gas flow, monitoring of a static magnetic field (B{sub o}), radio frequency (RF) irradiation timing, reaction temperature, and gas pressures. Current PHIP instruments manually control the hyperpolarization process resulting in the lack of the precise control of factors listed above, resulting in non-reproducible results. We discuss the design and implementation of a LabVIEW based computer program that automatically and precisely controls the delivery and manipulation of gases and samples, monitoring gas pressures, environmental temperature, and RF sample irradiation. We show that the automated control over the hyperpolarization process results in the hyperpolarization of hydroxyethylpropionate. The implementation of this software provides the fast prototyping of PHIP instrumentation for the evaluation of a myriad of {sup 13}C based endogenous contrast agents used in molecular imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic scale electron vortices for nanoresearch

Electron vortex beams were only recently discovered and their potential as a probe for magnetism in materials was shown. Here we demonstrate a method to produce electron vortex beams with a diameter of less than 1.2 Angst . This unique way to prepare free electrons to a state resembling atomic orbitals is fascinating from a fundamental physics point of view and opens the road for magnetic mapping with atomic resolution in an electron microscope.

36 MATERIALS SCIENCE↗

Energetic ion observations in the magnetic cloud of 14-15 January 1988 and their implications for the magnetic field topology

On 14-15 January 1988, a magnetic cloud with a local field topology consistent with an east-west aligned cylindrical flux-rope and which formed the driver of an interplanetary shock passed the earth. Using 0.5-4 MeV/n ion data from the instrument on IMP 8, the paper addresses the question of whether or not magnetic field lines within the magnetic cloud were connected to the sun. An impulsive solar particle event was detected inside the magnetic cloud strongly suggesting that the field lines were rooted at the sun.

Richardson, I. G.↗

HOMOLOGOUS HELICAL JETS: OBSERVATIONS BY IRIS, SDO, AND HINODE AND MAGNETIC MODELING WITH DATA-DRIVEN SIMULATIONS

We report on observations of recurrent jets by instruments on board the Interface Region Imaging Spectrograph, Solar Dynamics Observatory (SDO), and Hinode spacecraft. Over a 4 hr period on 2013 July 21, recurrent coronal jets were observed to emanate from NOAA Active Region 11793. Far-ultraviolet spectra probing plasma at transition region temperatures show evidence of oppositely directed flows with components reaching Doppler velocities of ±100 km s{sup −1}. Raster Doppler maps using a Si iv transition region line show all four jets to have helical motion of the same sense. Simultaneous observations of the region by SDO and Hinode show that the jets emanate from a source region comprising a pore embedded in the interior of a supergranule. The parasitic pore has opposite polarity flux compared to the surrounding network field. This leads to a spine-fan magnetic topology in the coronal field that is amenable to jet formation. Time-dependent data-driven simulations are used to investigate the underlying drivers for the jets. These numerical experiments show that the emergence of current-carrying magnetic field in the vicinity of the pore supplies the magnetic twist needed for recurrent helical jet formation.

79 ASTRONOMY AND ASTROPHYSICS↗

On ultrafast x-ray scattering methods for magnetism

With the introduction of x-ray free electron laser sources around the world, new scientific approaches for visualizing matter at fundamental length and time-scales have become possible. As it relates to magnetism and ‘magnetic-type’ systems, advanced methods are being developed for studying ultrafast magnetic responses on the time-scales at which they occur. We describe three capabilities which have the potential to seed new directions in this area and present original results from each: pump-probe x-ray scattering with low energy excitation, x-ray photon fluctuation spectroscopy, and ultrafast diffuse x-ray scattering. By combining these experimental techniques with advanced modeling together with machine learning, we describe how the combination of these domains allows for a new understanding in the field of magnetism. Finally, we give an outlook for future areas of investigation and the newly developed instruments which will take us there.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic domain wall contrast under zero domain contrast conditions in spin polarized low energy electron microscopy

Critical applications of spin polarized low energy electron microscopy (SPLEEM) employ this technique's vector imaging capability to resolve domain wall (DW) spin textures. Studying several thin film systems including Co/W(110), Co/Cu(001) and (Co/Ni) n /W(110), we demonstrate that an additional contrast can appear at magnetic DWs. By imaging the magnetization as a function of electron landing energy, electron energies are selected at which the magnetic domain contrast vanishes. Surprisingly, under such conditions of zero contrast between magnetic domains, we observe the appearance of magnetic contrast outlining the DWs. This DW contrast fails to depend on the DW spin texture. Instead, our measurements show that this DW contrast results from a combination of the energy-dependence of the spin reflectivity asymmetry of the magnetic film, the finite energy width of the spin polarized electron source, and the dispersion of the magnetic prism array that separates the illumination and imaging columns of the instrument. Awareness of this DW contrast mechanism is useful to aid correct interpretation of SPLEEM images.

74 ATOMIC AND MOLECULAR PHYSICS↗

In situ magnetic compensation for potassium spin-exchange relaxation-free magnetometer considering probe beam pumping effect

A novel method to compensate the residual magnetic field for an atomic magnetometer consisting of two perpendicular beams of polarizations was demonstrated in this paper. The method can realize magnetic compensation in the case where the pumping rate of the probe beam cannot be ignored. In the experiment, the probe beam is always linearly polarized, whereas, the probe beam contains a residual circular component due to the imperfection of the polarizer, which leads to the pumping effect of the probe beam. A simulation of the probe beam's optical rotation and pumping rate was demonstrated. At the optimized points, the wavelength of the probe beam was optimized to achieve the largest optical rotation. Although, there is a small circular component in the linearly polarized probe beam, the pumping rate of the probe beam was non-negligible at the optimized wavelength which if ignored would lead to inaccuracies in the magnetic field compensation. Therefore, the dynamic equation of spin evolution was solved by considering the pumping effect of the probe beam. Based on the quasi-static solution, a novel magnetic compensation method was proposed, which contains two main steps: (1) the non-pumping compensation and (2) the sequence compensation with a very specific sequence. After these two main steps, a three-axis in situ magnetic compensation was achieved. The compensation method was suitable to design closed-loop spin-exchange relaxation-free magnetometer. By a combination of the magnetic compensation and the optimization, the magnetic field sensitivity was approximately 4 fT/Hz{sup 1/2}, which was mainly dominated by the noise of the magnetic shield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile magnetometer assembly for characterizing magnetic properties of nanoparticles

We constructed a versatile magnetometer assembly for characterizing iron oxide nanoparticles. The magnetometer can be operated at room temperature or inside a cryocooler at temperatures as low as 6 K. The magnetometer’s sensor can be easily exchanged and different detection electronics can be used. We tested the assembly with a non-cryogenic commercial Hall sensor and a benchtop multimeter in a four-wire resistance measurement scheme. A magnetic moment sensitivity of 8.5 × 10{sup −8} Am{sup 2} was obtained with this configuration. To illustrate the capability of the assembly, we synthesized iron oxide nanoparticles coated with different amounts of a triblock copolymer, Pluronic F-127, and characterized their magnetic properties. We determined that the polymer coating does not affect the magnetization of the particles at room temperature and demonstrates that it is possible to estimate the average size of coating layers from measurements of the magnetic field of the sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermodynamic Analysis of the 3-Stage ADR for the Astro-H Soft X-Ray Spectrometer Instrument

The Soft X-ray Spectrometer (SXS) instrument on Astro-H will use a 3-stage ADR to cool the microcalorimeter array to 50 mK. In the primary operating mode, two stages of the ADR cool the detectors using superfluid helium at 1.20 K as the heat sink. In the secondary mode, which is activated when the liquid helium is depleted, two of the stages continuously cool the (empty) helium tank using a 4.5 K Joule-Thomson cooler as the heat sink, and the third stage cools the detectors. In the design phase, a high-fidelity model of the ADR was developed in order to predict both the cooling capacity and heat rejection rates in both operating modes. The primary sources of heat flow are from the salt pills, hysteresis heat from the magnets and magnetic shields, and power dissipated by the heat switches. The flight instrument dewar, ADR, detectors and electronics were integrated in mid-2014 and have since undergone extensive performance testing, in part to validate the performance model. This paper will present the thermodynamic performance of the ADR, including cooling capacity, heat rejection to the heat sinks, and various measures of efficiency.

space cryogenics↗

Design and development of permanent magnet based focusing lens for J-Band Klystron

Applying permanent magnet technology to beam focusing in klystrons can reduce their power consumption and increase their reliability of operation. Electromagnetic design of the beam focusing elements, for high frequency travelling wave tubes, is very critical. The magnitude and profile of the magnetic field need to match the optics requirement from beam dynamics studies. The rise of the field from cathode gun region to the uniform field region (RF section) is important as the desired transition from zero to peak axial field must occur over a short axial distance. Confined flow regime is an optimum choice to minimize beam scalloping but demands an axial magnetic field greater than 2 - 3 times the Brillouin flow field. This necessitates optimization in the magnet design achieve high magnetic field within given spatial constraints. Electromagnetic design and simulations were done using 3D Finite element method (FEM) analysis software. A permanent magnet based focusing lens for a miniature J-Band klystron has been designed and developed at Control Instrumentation Division, BARC. This paper presents the design, simulation studies, beam transmission and RF tests results for J Band klystron with permanent magnet focusing lens. (author)

43 PARTICLE ACCELERATORS↗