Ischemic Effects of Transcatheter Arterial Embolization with N-Butyl Cyanoacrylate-Lipiodol on the Colon in a Swine Model

This study was designed to assess the safety of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate-lipiodol (NBCA-Lp) for the large bowel and to investigate the vital response to NBCA-Lp in a swine model. In nine swine, nine arteries nourishing the colon were embolized with NBCA-Lp (1 ml of NBCA mixed with 4 ml of lipiodol): sigmoid-rectal branch artery in six swine, right colic branch artery in two, and middle colic branch artery in one. The amount of NBCA-Lp was 0.1-0.4 ml. Sacrifice was conducted 3 days after TAE to identify histological infarction. Classification was conducted retrospectively: group A, vasa recta without NBCA-Lp embolization despite TAE; group B, three or fewer vasa recta with NBCA-Lp embolization; and group C, five or more vasa recta with NBCA-Lp embolization. In one swine in group A, no necrotic focus was observed. In group B, three of four swine experienced no ischemic damage. The remaining one swine experienced necrosis of mucosal and submucosal layers in one-fourth of the circumference. In group C, all four swine with marginal artery and five vasa recta or more embolized experienced total necrosis of mucosa, submucosa, and smooth muscle layers of the whole colonic circumference. Significant difference on the extent of ischemic damage was observed between groups B and C (P < 0.05). Microscopically, NBCA-Lp induced acute vasculitis. Embolization of three or fewer vasa recta with NBCA-Lp induced no ischemic damage or limited necrosis, whereas embolization of five or more vasa recta with NBCA-Lp induced extensive necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal Ablation of Lung Tissue: In Vivo Experimental Comparison of Microwave and Radiofrequency

This study was designed to compare feasibility, safety, and effectiveness of microwave (MW) ablation versus radiofrequency (RF) ablation of lung tissue in a rabbit model. Twenty New Zealand White rabbits were submitted to MW (n = 10, group A) or RF ablation (n = 10, group B). The procedures were performed with a prototype MW ablation device with a 1.6-cm radiating section antenna (Valleylab MW Ablation System) and with a 2-cm exposed-tip RF electrode (Cool-tip RF Ablation System). At immediate computed tomography increase in density, maximum diameters (D1-D3) of ablation zones were measured and ablation volume was calculated. Histopathologic assessment was performed 3 and 7 days after the procedure. Technical success was achieved in nine of 10 rabbits in each group. One death occurred in group B. Complications included pneumothorax (group A, n = 4; group B, n = 4), abscess (group A, n = 1; group B, n = 1), and thoracic wall burn (group A, n = 4). No significant differences were demonstrated in attenuation increase (P = 0.73), dimensions (P = 0.28, 0.86, 0.06, respectively, comparing D1-D3) and volume (P = 0.17). At histopathology, ablation zones were similar, with septal necrosis, edema, hemorrhage, and peripheral lymphocytic infiltrate. Complete thrombosis of more than 90% of vessels up to 2 mm in diameter was depicted at the periphery of the ablation zone in group A specimens. In group B specimens, complete thrombosis was depicted in 20% of vessels. Feasibility and safety of MW and RF ablation are similar in a lung rabbit model. MW ablation produces a greater damage to peripheral small vessels inducing thrombosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Reintervention After Endovascular Repair of Isolated Iliac Artery Aneurysm

The objective of this study was to identify factors predicting the need for reintervention after endovascular repair of isolated iliac artery aneurysm (IIAA). We reviewed prospectively collected database records of all patients who underwent endovascular repair of IIAA between 1999 and 2008. Detailed assessment of the aneurysms was performed using computed tomography angiography (CTA). Follow-up protocol included CTA at 3 months. If this showed no complication, then annual duplex scan was arranged. Multivariate analysis and analysis of patient survival and freedom from reintervention were performed using Kaplan-Meier life tables. Forty IIAAs (median diameter 44 mm) in 38 patients were treated (all men; median age 75 years), and median follow-up was 27 months. Endovascular repair of IIAA was required in 14 of 40 aneurysms (35%). The rate of type I endoleak was significantly higher with proximal landing zone (PLZ) diameter >30 mm in the aorta or >24 mm in the common iliac artery or distal landing zone (DLZ) diameter >24 mm (P = 0.03, 0.03, and 0.0014, respectively). Reintervention rate (RR) increased significantly with increased diameter or decreased length of PLZ; increased DLZ diameter; and endovascular IIAA repair (P = 0.005, 0.005, 0.02, and 0.02 respectively); however, RR was not significantly affected by length of PLZ or DLZ. Freedom-from-reintervention was 97, 93, and 86% at 12, 24, and 108 months. There was no in-hospital or aneurysm-related mortality. Endovascular IIAA repair is a safe treatment option. Proper patient selection is essential to decrease the RR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Massive Pulmonary Embolism: Treatment with the Rotarex Thrombectomy System

This study was designed to evaluate the efficacy and safety of percutaneous mechanical thrombectomy (PMT) for acute massive pulmonary embolism (PE). Fourteen patients (8 men, 6 women) with a mean age of 55.4 (range, 38-71) years with acute massive PE were initially diagnosed by computed tomography (CT) and confirmed by pulmonary angiography. All patients presented with acute PE symptoms and hemodynamic compromise. Each patient was treated with Straub Rotarex thrombectomy device and five patients received additional thrombolysis. Technique success and clinical improvement were achieved in all patients without major complications. The mean pulmonary artery pressure (PAP) decreased from 37.6 {+-} 6.6 to 29 {+-} 6.4 mmHg (P < 0.01) after PMT. Partial arterial pressures of O{sub 2} (PaO{sub 2}) increased from 61.1 {+-} 9.2 to 88 {+-} 5.1 mmHg (P < 0.01). The Miller index was 0.67 {+-} 0.11 and 0.37 {+-} 0.13 (P < 0.01), respectively, before and after PMT (P < 0.01). Eleven patients had no recurrence of PE on a mean follow-up of 28.3 months, whereas the other three patients were lost to follow-up. The preliminary experience in our series suggests that the Straub Rotarex thrombectomy device, which has been utilized in peripheral arteries, also is useful for the treatment of acute massive PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Occlusion of Arteriovenous Fistulas of In-Situ Saphenous Vein Bypass Grafts Using the Amplatzer Vascular Plug 4: Initial Experience

We examined the safety and efficacy of vessel occlusion of the Amplatzer Vascular Plug 4 (AVP-4) in patients with arteriovenous fistulas after in-situ saphenous vein bypass grafts. We treated 18 fistulas of seven patients (four women, mean {+-} standard deviation age 76 {+-} 7 years, range 63-88 years). All fistulas were detected within 14 days after surgery. Initial diagnosis and follow-up was established by sonography. We measured the diameter of the feeding vessel and the time of vessel occlusion after plug deployment. Additionally, we recorded procedure time and the dose area product. Additional interventional procedures were necessary in three patients. We successfully used 19 AVP-4 for occlusion of all fistulas without thromboembolic complications. There was no need for recapturing the device, and we did not observe dislocation. Mean occlusion time was 9.6 min (range 5-22 min). Mean diameter of the feeding vessels was 3.5 mm (range 2.6-5.1 mm). Plug sizes ranged from 4-8 mm (mean 5.5 mm) resulting in an oversizing of 33-88%. Mean procedure time for patients with and without additional intervention was 91 {+-} 38 min and 35 {+-} 18 min, respectively. Mean dose area product was 11,790 cGy/cm{sup 2} (range 1,850-23,500 cGy/cm{sup 2}). Permanent occlusion of the fistulas was confirmed by ultrasound after a mean follow-up of 4 months (1-6 months). Occlusion of arteriovenous fistulas with an AVP-4 seems to be effective and safe in patients with in-situ saphenous vein bypass grafts. The AVP-4 is well suited for this purpose because of the appropriate diameter of the feeding vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Current Combined With Bipolar Radiofrequency Ablation: An Ex Vivo Feasibility Study

The combination of radiofrequency ablation (RFA) with direct current (DC) is a promising strategy to improve the efficiency of RFA. However, DC-enhanced monopolar RFA is limited by electrolytic injury at the positive-electrode site. The aim of this study was to investigate the feasibility of the DC-enhanced bipolar RFA. To obviate the need for the subcutaneous positive electrode, the DC circuit was combined with a commercially available bipolar RFA system, in which both poles of the DC circuit are connected to a single RF probe. DC was applied for 15 min and followed by RFA in bovine livers using the following various DC currents: (1) no DC (control), (2) 3V continued until the end of RFA, (3) 5V continued until the end of RFA, (4) 10V continued until the end of RFA, (5) 5V continued in the circuit with reversed pole, (6) 3V stopped after initiation of RFA, and (7) 5V stopped. Coagulation volume, temperatures at a distance of 5, 10, and 15 mm from the RF probe, mean amperage, ablation duration, applied energy, minimum impedance, and degree of tissue charring were assessed and compared (analysis of variance, Student-Newman-Keuls test). All combined DC and RFA groups did increase coagulation volume. The 10V continued group showed significantly lower applied energy, shortest ablation duration, highest minimum impedance, and highest degree of charring with the lowest coagulation volume (p < 0.05). DC-enhanced bipolar RFA with both poles of the DC circuit on a single probe appears to be ineffective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape

The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs. To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cisplatin-Conjugated Porous Gelatin Particles: Assessment of Optimal Conditions for Binding and Release

This study was designed to evaluate the optimal conditions for binding cisplatin and porous gelatin particles (PGPs) and to establish in vivo drug release pharmacokinetics. PGPs were immersed in cisplatin solutions under different conditions: concentration, immersion time, and temperature. Thereafter, PGPs were washed in distilled water to remove uncombined cisplatin and were then freeze-dried. The platinum concentration (PC) in the PGPs was then measured. For the in vivo release test, 50 mg/kg of the cisplatin-conjugated PGPs was implanted subcutaneously in the abdominal region of two rabbits. PCs in the blood were measured at different time intervals. PCs significantly increased in direct proportion to the concentration and immersion time (p < 0.01). Although PC increased at higher solution temperature, it was not a linear progression. For the in vivo release test, platinum was released from cisplatin-conjugated PGPs after 1 day, and the peak PC was confirmed 2 days after implantation. Platinum in the blood was detected until 7 days after implantation in one rabbit and 15 days after administration in the other rabbit. Platinum binding with PGPs increased with a higher concentration of cisplatin solution at a higher temperature over a longer duration of time. Release of cisplatin from cisplatin-conjugated PGPs was confirmed in vivo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External Carotid-Internal Jugular Fistula as a Late Complication After Carotid Endarterectomy: A Rare Case

A 66-year-old man presented with mild amnesia, progressive fatigue, ataxia, visual hallucinations, and debility. His past medical history included right-sided carotid endarterectomy performed elsewhere 6 years previously. Cranial magnetic resonance imaging showed left parieto-occipital arteriovenous malformation-like tortous vessels, venous congestion, and ischemic areas. Cerebral angiography showed right-sided compound external carotid artery-internal jugular vein (IJV) fistula, and distal occlusion of the right IJV. Transvenous embolization via contralateral IJV was performed, and the fistula, together with fistulous portion of the distal IJV, was sealed using coils. Two years later, patient is well with normal neurologic examination findings. The presence of an arteriovenous communication after vascular surgery is a serious complication with potential long-term effects and therefore should be diagnosed and treated as promptly as possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57-93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 {+-} 13 (SD) min (range 24-78). The average follow-up time interval was 103 days (range 7-812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience of Uterine Fibroid Embolization Using Porous Gelatin Sponge Particles

The purpose of this study was to prospectively assess the safety and effectiveness of uterine artery embolization (UAE) using porous gelatin particle (PGP; Gelpart; Asuterasu, Tokyo, Japan) for symptomatic uterine fibroids. Twenty-five consecutive premenopausal women underwent UAE with PGP. The angiographic end point of embolization was near stasis of the ascending uterine artery. Pelvic magnetic resonance imaging (MRI) was obtained before and after the procedure. Complications were assessed. The outcomes of technique, infarction rates of all fibroid tissue after UAE with contrast-enhanced MRI, change in symptoms and quality of life using serial Uterine Fibroid Symptom and Quality of Life (UFS-QOL) questionnaires, and additional interventions were evaluated. Bilateral UAE was successfully performed in all patients. Enhanced MRI 1 week after UAE showed that 100% infarction of all fibroid tissue was achieved in 65% (15 of 23) of patients; 90-99% infarction was achieved in 35% (8 of 23) of patients. Mean follow-up was 12 months (range 1-20). Symptom and QOL scores at baseline were 47.2 and 61.7, respectively. Both scores significantly improved to 26.3 (P < 0.001) and 82.4 (P < 0.001) at 4 months and to 20.4 (P < 0.001) and 77.6 (P < 0.001) at 1 year, respectively. No additional gynecologic interventions were performed in any patient. There were no major complications. Minor complications occurred in two patients. UAE using PGP is a safe and effective procedure and shows that outcomes after UAE, as measured with enhanced MRI and UFS-QOL questionnaires, seem comparable with those of UAE using other embolic agents. PGP is a promising embolic agent used for UAE to treat symptomatic uterine fibroids. Further comparative study between PGP and other established embolic agents is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optease Vena Cava Filter Optimal Indwelling Time and Retrievability

The purpose of this study was to assess the indwelling time and retrievability of the Optease IVC filter. Between 2002 and 2009, a total of 811 Optease filters were inserted: 382 for prophylaxis in multitrauma patients and 429 for patients with venous thromboembolic (VTE) disease. In 139 patients [97 men and 42 women; mean age, 36 (range, 17-82) years], filter retrieval was attempted. They were divided into two groups to compare change in retrieval policy during the years: group A, 60 patients with filter retrievals performed before December 31 2006; and group B, 79 patients with filter retrievals from January 2007 to October 2009. A total of 128 filters were successfully removed (57 in group A, and 71 in group B). The mean filter indwelling time in the study group was 25 (range, 3-122) days. In group A the mean indwelling time was 18 (range, 7-55) days and in group B 31 days (range, 8-122). There were 11 retrieval failures: 4 for inability to engage the filter hook and 7 for inability to sheathe the filter due to intimal overgrowth. The mean indwelling time of group A retrieval failures was 16 (range, 15-18) days and in group B 54 (range, 17-122) days. Mean fluoroscopy time for successful retrieval was 3.5 (range, 1-16.6) min and for retrieval failures 25.2 (range, 7.2-62) min. Attempts to retrieve the Optease filter can be performed up to 60 days, but more failures will be encountered with this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superior Mesenteric Artery Embolism Treated with Percutaneous Mechanical Thrombectomy

A case of acute superior mesenteric artery embolism treated with percutaneous thrombus aspiration is described. A 63-year-old man with chronic atrial fibrillation was admitted to the hospital with progressive abdominal pain. Computed tomography angiography revealed an occlusion of the distal part of the superior mesenteric artery. The patient was effectively treated using transaxillary percutaneous mechanical thrombectomy using a 6F Aspirex thrombectomy catheter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Revascularization of Chronically Thrombosed Arteriovenous Fistulas and Grafts for Hemodialysis: A Retrospective Study in 15 Patients With 18 Access Sites

The current study retrospectively evaluated whether endovascular revascularization of chronically thrombosed and long-discarded vascular access sites for hemodialysis was feasible. Technical and clinical success rates, postintervention primary and secondary patency rates, and complications were reported. During a 1-year period, we reviewed a total of 924 interventions performed for dysfunction and/or failed hemodialysis vascular access sites and permanent catheters in 881 patients. In patients whose vascular access-site problems were considered untreatable or were considered treatable with a high risk of failure and access-site abandonment, we attempted to revascularize (resurrect) the chronically occluded and long-discarded (mummy) vascular access sites. We attempted to resurrect a total of 18 mummy access sites (mean age 46.6 {+-} 38.7 months; range 5-144) in 15 patients (8 women and 7 men; mean age 66.2 {+-} 11.5 years; age range 50-85) and had an overall technical success rate of 77.8%. Resurrection failure occurred in 3 fistulas and in 1 straight graft. The clinical success rate was 100% at 2 months after resurrection. In the 14 resurrected vascular access sites, 6 balloon-assisted maturation procedures were required in 5 fistulas; after access-site maturation, a total of 22 interventions were performed to maintain access-site patency. The mean go-through time for successful resurrection procedures was 146.6 {+-} 34.3 min (range 74-193). Postmaturation primary patency rates were 71.4 {+-} 12.1% at 30 days, 57.1 {+-} 13.2% at 60 days, 28.6 {+-} 13.4% at 90 days, and 19 {+-} 11.8% at 180 days. Postmaturation secondary patency rates were 100% at 30, 60, and 90 days and 81.8 {+-} 11.6% at 180 days. There were 2 major complications consisting of massive venous ruptures in 2 mummy access sites during balloon dilation; in both cases, prolonged balloon inflation failed to achieve hemostasis, but percutaneous N-butyl cyanoacrylate glue seal-off was performed successfully. Percutaneous resurrection of mummy vascular access sites for hemodialysis is technically feasible with high clinical success rates. In selected patients, resurrection of mummy access sites provides long-discarded access sites one more chance to be used for hemodialysis in an effort to preserve potential extremity sites for future access-site placement and to prevent long-term catheter indwelling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Percutaneous Drainage of Infected Collections Due to Gastric Leak After Sleeve Gastrectomy for Morbid Obesity: Initial Experience

This study was designed to evaluate the efficacy and safety of computed tomography (CT)-guided drainage in treating infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity. From January 2007 to June 2009, 21 patients (9 men and 12 women; mean age, 39.2 (range, 26-52) years) with infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity underwent image-guided percutaneous drainage. All procedures were performed using CT guidance and 8- to 12-Fr pigtail drainage catheters. Immediate technical success was achieved in all 21 infected collections. In 18 of 21 collections, we obtained progressive shrinkage of the collection with consequent clinical success (success rate 86%). In three cases, the abdominal fluid collection was not resolved, and the patients were reoperated. Among the 18 patients who avoided surgery, 2 needed replacement of the catheter due to obstruction. No major complications occurred during the procedure. The results of our study support that CT-guided percutaneous drainage is an effective and safe method to treat infected abdominal fluid collections due to gastric leak in patients who had previously underwent laparoscopic sleeve gastrectomy for morbid obesity. It may be considered both as a preparatory step for surgery and a valuable alternative to open surgery. Failure of the procedure does not, however, preclude a subsequent surgical operation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metachronous Bilateral Posterior Tibial Artery Aneurysms in Ehlers-Danlos Syndrome Type IV

Ehlers-Danlos syndrome type IV is a life-threatening genetic connective tissue disorder. We report a 24-year-old woman with EDS-IV who presented with metachronous bilateral aneurysms/pseudoaneurysms of the posterior tibial arteries 15 months apart. Both were treated successfully with transarterial coil embolization from a distal posterior tibial approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Application of Percutaneous Cryotherapy for the Treatment of Recurrent Oral Bleeding From a Noninvoluting Congenital Hemangioma Involving the Right Buccal Space and Maxillary Tuberosity

Cryotherapy is the application of varying extremes of cold temperatures to destroy abnormal tissue. The intent of this article is to describe a novel technique using percutaneous cryotherapy for treating a noninvoluting congenital craniofacial hemangioma (NICH). An 18-year-old woman with type 1 von Willebrand's disease, as well as a qualitative platelet aggregation disorder, presented with multiple recurrent episodes of oral bleeding from a NICH involving the right buccal space and maxillary tuberosity. The patient was initially treated with a combination of endovascular particulate embolization, percutaneous sclerotherapy, tissue cauterization, and laser therapy between the ages of 4 and 8 years of age. At 18 years of age, the patient presented with recurrent episodes of oral bleeding related to the NICH. Endovascular embolization was performed using particulate and a liquid embolic agent with limited success. Due to the refractory nature of this bleeding, the patient underwent successful lesion ablation using percutaneous cryotherapy. At 9-month follow-up, the patient is asymptomatic with no episodes of recurrent bleeding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗