Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Using light and X-ray scattering to untangle complex neuronal orientations and validate diffusion MRI

Disentangling human brain connectivity requires an accurate description of nerve fiber trajectories, unveiled via detailed mapping of axonal orientations. However, this is challenging because axons can cross one another on a micrometer scale. Diffusion magnetic resonance imaging (dMRI) can be used to infer axonal connectivity because it is sensitive to axonal alignment, but it has limited spatial resolution and specificity. Scattered light imaging (SLI) and small-angle X-ray scattering (SAXS) reveal axonal orientations with microscopic resolution and high specificity, respectively. Here, we apply both scattering techniques on the same samples and cross-validate them, laying the groundwork for ground-truth axonal orientation imaging and validating dMRI. We evaluate brain regions that include unidirectional and crossing fibers in human and vervet monkey brain sections. SLI and SAXS quantitatively agree regarding in-plane fiber orientations including crossings, while dMRI agrees in the majority of voxels with small discrepancies. We further use SAXS and dMRI to confirm theoretical predictions regarding SLI determination of through-plane fiber orientations. Scattered light and X-ray imaging can provide quantitative micrometer 3D fiber orientations with high resolution and specificity, facilitating detailed investigations of complex fiber architecture in the animal and human brain.

59 BASIC BIOLOGICAL SCIENCES↗

Visible and near-ultraviolet spectra of low-pressure rare-gas microwave discharges

The spectral emission characteristics of three commercial low pressure rare gas discharge lamps wire obtained in the near ultraviolet and visible wavelength range. All three lamps show a definite continuum over the entire wavelength range from 0.185 to 0.6 micrometers. Considerable line emission is superimposed on much of the continuum for wavelengths greater than 0.35 micrometers. These sources were used to make transmittance measurements on quartz samples in the near ultraviolet wavelength range.

Campbell, J. P.↗

A relative performance analysis of atmospheric Laser Doppler Velocimeter methods.

Evaluation of the effectiveness of atmospheric applications of a Laser Doppler Velocimeter (LDV) at a wavelength of about 0.5 micrometer in conjunction with dual scatter LDV illuminating techniques, or at a wavelength of 10.6 micrometer with local oscillator LDV illuminating techniques. Equations and examples are given to provide a quantitative basis for LDV system selection and performance criteria in atmospheric research. The comparative study shows that specific ranges and conditions exist where performance of one of the methods is superior to that of the other. It is also pointed out that great care must be exercised in choosing system parameters that optimize a particular LDV designed for atmospheric applications.

Farmer, W. M.↗

Surface roughness effects on bidirectional reflectance

An experimental study of surface roughness effects on bidirectional reflectance of metallic surfaces is presented. A facility capable of irradiating a sample from normal to grazing incidence and recording plane of incidence bidirectional reflectance measurements was developed. Samples consisting of glass, aluminum alloy, and stainless steel materials were selected for examination. Samples were roughened using standard grinding techniques and coated with a radiatively opaque layer of pure aluminum. Mechanical surface roughness parameters, rms heights and rms slopes, evaluated from digitized surface profile measurements are less than 1.0 micrometers and 0.28, respectively. Rough surface specular, bidirectional, and directional reflectance measurements for selected values of polar angle of incidence and wavelength of incident energy within the spectral range of 1 to 14 micrometers are reported. The Beckmann bidirectional reflectance model is compared with reflectance measurements to establish its usefulness in describing the magnitude and spatial distribution of energy reflected from rough surfaces.

Smith, T. F.↗

Satellite observations during the rapid intensification of hurricane Camille

Medium resolution infrared radiometer observations at the 6.7 micrometer and the 11 micrometer regions by satellite during the maximum intensification phase of hurricane Camille show increasing black body temperatures near the center. This is attributed to increased upward vertical motion in the interior of the cyclone, which is an indication of rapid intensification.

Shenk, W. E.↗

Mariner 9 ultraviolet spectrometer experiment - Seasonal variation of ozone on Mars.

Ozone is observed to be present in the polar regions of Mars and to have a seasonal variation. In the summer, the amount present in the polar atmosphere is less than 3 micrometer-atmospheres. In the fall, ozone increases in amount and is found in association with the formation of the polar hood. In winter, the maximum amount of ozone is present, 57 micrometer-atmospheres over the polar hood and 16 over the polar cap. In spring, the amount over the polar cap decreases monotonically until by the beginning of summer the ozone disappears. Ozone is not observed in the equatorial region during any season.

Barth, C. A.↗

VLS /vapor-liquid-solid/ - Newly discovered growth mechanism on the lunar surface.

A probable vapor-liquid-solid (VLS) type of growth has been discovered for the first time in nature on the surface of lunar rock 15015. Scanning electron microprobe and energy dispersive x-ray data indicate that the growth occurs as metallic iron stalks from about 0.015 to 0.15 micrometer in diameter, with bulbous tips consisting of a mixture of iron and sulfur and measuring from about 0.03 to 0.2 micrometer in diameter. The stalk length is two to ten times the bulb diameter.

Carter, J. L.↗

A Stokes' velocity photographic method for measuring the size distribution of aerosols

Aerosol particles are allowed to settle in a vertical glass walled vessel, and their settling velocity is determined by photographing them while the light entering the camera is being chopped at a known rate. The settling velocity of each particle can be determined from the photographs, and by applying the Stokes' law, one can calculate the radius of each particle. The Stokes' law for a sphere settling freely in a quiet medium is given. If the volume of the photographed region of the illumination is known, the aerosol number density and size distribution can be obtained. Experiments with alumina particles of given size distributions indicate that the method works accurately. One set of a typical experiment with 3.0-micrometer Al2O3 particles is presented, which shows that the measured size distribution peaks at approximately 3.0 micrometer.

Deepak, A.↗

In situ measurement of particulate number density and size distribution from an aircraft

Commercial particulate measuring instruments were flown aboard the NASA Convair 990. A condensation nuclei monitor was utilized to measure particles larger than approximately 0.003 micrometers in diameter. A specially designed pressurization system was used with this counter so that the sample could be fed into the monitor at cabin altitude pressure. A near-forward light scattering counter was used to measure the number and size distribution particles in the size range from 0.5 to 5 micrometers and greater in diameter.

Briehl, D.↗

Does Io have an ammonia atmosphere

A number of anomalous or discordant observations of Io can be explained if this Jovian satellite has an atmosphere containing ammonia. Such an atmosphere will be frozen at the unilluminated pole during the solstices, but will evaporate at the equinoctial seasons. The ammonia atmosphere will explain (1) the posteclipse brightenings and their observed times of occurrence and nonoccurrence; (2) the observed departure from a two-layer model heating curve upon emergency from the eclipse; (3) the discordant temperatures obtained at 10 and 20 micrometers; and (4) discordant temperatures obtained at 10 and 20 micrometers during the total phase of an eclipse by Jupiter.

Sinton, W. M.↗

Infrared spectroscopy of lunar mare regolith

Spectra of reflection, emission, and transmission of regolith returned by the Luna 16 automatic station were investigated in the 1.8-13 micrometers region. A reflection maximum was shown to be present in the region 3 to 5 micrometer, along with a corresponding minimum in the emission coefficient. The spectra were interpreted based on a comparison of the optical properties with the chemical and structural properties of the regolith. The regolith in the entire array of properties in the infrared region differs appreciably from terrestrial objects. Spectra of diffuse reflection and the spectra at angles of incidence 0 deg and angles of reflection 15 and 30 deg with samples of the regolith returned by the Apollo 11 and Apollo 12 missions revealed a similarity of the infrared reflection characteristics of the regolith from different lunar mare regions.

M. V. Akhmanova↗

Calibration source for remote sensors

The source described was developed as a calibration target for the multispectral scanner (MSS) which was flown on the Earth Resources Technology Satellite A (LANDSAT 1). The wavelength region of interest covered the four (4) MSS bands extending from 0.5 to 1.1 micrometers, although the target was calibrated from 0.32 to 2.5 micrometers. The following characteristics for the target were required: (1) large aperture, sufficient to accommodate an instrument with a 9 inch (23 centimeters(cm)) aperture and 2 1/2 deg field of view (fov), (2) highly diffuse energy from target, (3) high spatial uniformity across aperture area of source, (4) spectrally calibrated in absolute units, (5) stable output over long periods of time (1-2 yrs), and (6) rugged, yet portable enough to be easily transported long distances without detrimental effects on the operational capabilities of the target. Two approaches were considered: a thirty (30) inch (76 cm) diameter integrating sphere with a twelve inch (30.5 cm) exit port, or the use of one hemisphere of a 76 cm sphere in conjunction with a Kodak ektolite screen. The screen has the property of reflecting back uniformly into a well defined area the majority of the light received. After some preliminary trials it seemed that the 76 cm sphere would give the most satisfactory results.

Mclean, J. T.↗

Multispectral mapping of the lunar surface using groundbased telescopes

Images of the lunar surface were obtained at several wavelengths using a silicon vidicon imaging system and groundbased telescopes. These images were recorded and processed in digital form so that quantitative information is preserved. The photometric precision of the images is shown to be better than 1 percent. Ratio images calculated by dividing images obtained at two wavelengths (0.40/0.56 micrometer) and 0.95/0.56 micrometer are presented for about 50 percent of the lunar frontside. Spatial resolution is about 2 km at the sub-earth point. A complex of distinct units is evident in the images. Earlier work with the reflectance spectrum of lunar materials indicates that for the most part these units are compositionally distinct. Digital images of this precision are extremely useful to lunar geologists in disentangling the history of the lunar surface.

Mccord, T. B.↗

The Screwworm Eradication Data System (SEDS)

One of the objectives of the SEDS was to build a versatile, yet economical, interactive system on the existing digital PDP 11/45 computers used in the Skylab production processing system. Previous experience on various interactive systems gave some background in the best methods of handling image data, registering and correcting the data, and extracting useful information from the images. The screwworm was eliminated in many parts of the United States by air-dropping sterile screwworms in areas where screwworms breed. The reproduction of the screwworm can be more or less predicted based on weather conditions -- cold weather slows the breeding, warm weather fosters it, and some moisture appears to enhance breeding conditions which, in turn, improves the chances of screwworm population growth. To obtain temperature and moisture conditions from remote areas, the NOAA improved TIROS operational satellite was selected to give data from the very high resolution radiometer (VHRR). The VHRR is a two-channel scanning instrument sensitive to energy in the visible spectrum from 0.6 to 0.7 micrometers and the infrared spectrum from 10.5 to 12.5 micrometers.

Quinn, M. J.↗

Time temperature-stress dependence of boron fiber deformation

Flexural stress relaxation (FSR) and flexural internal friction (FIF) techniques were employed to measure the time-dependent deformation of boron fibers from -190 to 800 C. The principal specimens were 203 micrometers diameter fibers commercially produced by chemical vapor deposition (CVD) on a 13 micrometer tungsten substrate. The observation of complete creep strain recovery with time and temperature indicated that CVD boron fibers deform flexurally as anelastic solids with no plastic component.

Dicarlo, J. A.↗

Spectral reflectance and radiance characteristics of water pollutants

Spectral reflectance characteristics of water pollutants and water bodies were compiled using the existing literature. Radiance calculations were performed at satellite altitude for selected illumination angles and atmospheric conditions. The work described in this report was limited to the reflective portion of the spectrum between 0.40 micrometer to 1.0 micrometer.

Wezernak, C. T.↗

Experiment definition phase shuttle laboratory. LDRL-10.6 experiment

The work completed on the experiment definition phase of the shuttle laboratory LDRL 10.6 micrometers experiment from 27 September 1975 to 26 January 1976 was reported. This work included progress in the following areas: (1) optomechanical system: completion of detail drawings, completion of the beryllium subassembly, fabrication, checking, and weighing of approximately 95% of the detailed parts, dry film lubrication of the bearings and gears, and initiation of assembly of the gimbals; (2) optics: update of the detailed optical layout, receipt of nine mirrors and the pre-expander; (3) miscellaneous: delivery of draft material for the final report, completion of optical testing of the 10.6 micrometers receiver, and receipt, assembly, and checkout of NASA test console.

Source record↗

Lodestone: Nature's own permanent magnet

Magnetic hysteresis and microstructural details are presented which explain why the class of magnetic iron ores defined as proto-lodestones, can behave as permanent magnets, i.e. lodestones. Certain of these proto-lodestones which are not permanent magnets can be made into permanent magnets by charging in a field greater than 1000 oersted. This fact, other experimental observations, and field evidence from antiquity and the middle ages, which seems to indicate that lodestones are found as localized patches within massive ore bodies, suggests that lightning might be responsible for the charging of lodestones. The large remanent magnetization, high values of coercive force, and good time stability for the remanent magnetization are all characteristics of proto-lodestone iron ores which behave magnetically as fine scale ( 10 micrometer) intergrowths when subjected to magnetic hysteresis analysis. The magnetic results are easily understood by analysis of the complex proto lodestone microstructural patterns observable at the micrometer scale and less.

Wasilewski, P.↗