Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Study of the thermal properties of filaments for 3D printing

Various materials are used for 3D printing, most commonly Acrylonitrile butadiene styrene (ABS), Polylactic acid (PLA), Polyethylene (PET) and Polypropylene (PP). These materials differ mainly in their melting point, which significantly influences the properties of the final products. Filaments are melted in the print head during the printing process. The temperature range is from 150 °C to 250 °C depending on the technology used. The optimum temperature for the cooling substrate on which printing is carried out is chosen so as to ensure uniform cooling and deformation. It generally varies between (40 – 100) °C. From the above it is clear that both temperatures can significantly affect the properties of the printed 3D object. It is therefore important to determine the thermal parameters (thermal conductivity, specific heat and thermal diffusivity) of the materials used across the entire range of temperatures. For evaluating the properties of different types of PLA materials, the step transient method was used, which allows determination of all required parameters using a fractal heat transfer model.

36 MATERIALS SCIENCE↗

Modeling of He - Defect Interactions in Ferritic Alloys for Fusion

High concentrations of helium will be produced in fusion reactor structural materials due to neutron capture reactions. The creep-rupture and fracture properties may be severely degraded if helium aggregates at grain boundaries to a sufficiently high level. To design helium-resistant microstructures requires detailed knowledge of the transport and fate of helium to sinks. We utilize atomistic methods to study the fate of helium in the neighborhood of dislocations, grain boundaries and coherent nano-clusters in alpha-iron. The binding energies of helium to these defects are strongly correlated with excess atomic volume. Molecular dynamics and the dimer saddle point search method were employed to study the mobility of both interstitial helium atoms and helium-vacancy complexes in dislocations and grain boundaries. The migration energy of interstitial helium in these defects was found to range from about 0.4 to 0.5 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Submerged Fatigue Testing of Marine Energy Advanced Materials

Marine energy structures are typically made of advanced composite materials and are subjected to extreme ocean environments in service. In extreme ocean environments, seawater currents and waves load structures repeatedly, which cause two environmental conditions: water intrusion and mechanical fatigue. In prior research, the two environmental conditions were applied sequentially, where composite specimens were aged and then mechanically tested. To understand the combined effects of dynamic loading and water intrusion on composite materials, the present study involves the static and fatigue four-point bend testing of composite coupons in a water tank. The water tank was designed and built to fit either a 100 kN or a 250 kN load frame. Flexural strength value, cycles to failure, and failure mode results from submerged fatigue testing will be used to inform marine energy structure designs. The coupon-scale test method will be used to scale up to and inform methods for subsequent subcomponent testing and standards development. The benefits of designing marine energy structures to informed standards are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite materials↗

Prospective Clinical Trial of Bladder Filling and Three-Dimensional Dosimetry in High-Dose-Rate Vaginal Cuff Brachytherapy

Purpose: To investigate the effect of bladder filling on dosimetry and to determine the best bladder dosimetric parameter for vaginal cuff brachytherapy. Methods and Materials: In this prospective clinical trial, a total of 20 women underwent vaginal cylinder high-dose-rate brachytherapy. The bladder was full for Fraction 2 and empty for Fraction 3. Dose-volume histogram and dose-surface histogram values were generated for the bladder, rectum, and urethra. The midline maximal bladder point (MBP) and the midline maximal rectal point were recorded. Paired t tests, Pearson correlations, and regression analyses were performed. Results: The volume and surface area of the irradiated bladder were significantly smaller when the bladder was empty than when full. Of the several dose-volume histogram and dose-surface histogram parameters evaluated, the bladder maximal dose received by 2 cm{sup 3} of tissue, volume of bladder receiving {>=}50% of the dose, volume of bladder receiving {>=}70% of the dose, and surface area of bladder receiving {>=}50% of the dose significantly predicted for the difference between the empty vs. full filling state. The volume of bladder receiving {>=}70% of the dose and the maximal dose received by 2 cm{sup 3} of tissue correlated significantly with the MBP. Bladder filling did not alter the volume or surface area of the rectum irradiated. However, an empty bladder did result in the nearest point of bowel being significantly closer to the vaginal cylinder than when the bladder was full. Conclusions: Patients undergoing vaginal cuff brachytherapy treated with an empty bladder have a lower bladder dose than those treated with a full bladder. The MBP correlated well with the volumetric assessments of bladder dose and provided a noninvasive method for reporting the MBP dose using three-dimensional imaging. The MBP can therefore be used as a surrogate for complex dosimetry in the clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of transverse shear strains in pre-twisted thick beams using variational asymptotic method

The cross-sectional stiffness matrix is derived for a pre-twisted, moderately thick beam made of transversely isotropic materials and having rectangular cross sections. An asymptotically-exact methodology is used to model the anisotropic beam from 3-D elasticity, without any further assumptions. The beam is allowed to have large displacements and rotations, but small strain is assumed. The strain energy is computed making use of the beam constitutive law and kinematical relations derived with the inclusion of geometrical nonlinearities and an initial twist. The energy functional is minimized making use of the Variational Asymptotic Method (VAM), thereby reducing the cross section to a point on the beam reference line with appropriate properties, forming a 1-D constitutive law. VAM is a mathematical technique employed in the current problem to rigorously split the 3-D analysis of beams into two: a 2-D analysis over the beam cross-sectional domain, which provides a compact semi-analytical form of the properties of the cross sections, and a nonlinear 1-D analysis of the beam ref-erence curve. In this method, as applied herein, the cross-sectional analysis is performed asymptotically by taking advantage of a material small parameter and two geometric small parameters. 3-D strain components are derived using kinematics and arranged in orders of the small parameters. Closed-form expressions are derived for the 3-D non-linear warping and stress fields. Warping functions are obtained by the minimization of strain energy subject to certain set of constraints that render the 1-D strain measures well-defined. The zeroth-order 3-D warping field thus yielded is then used to integrate the 3-D strain energy density over the cross section, resulting in the 1-D strain energy density, which in turn helps identify the corresponding cross-sectional stiffness matrix. The model is capable of predicting interlaminar and transverse shear stresses accurately up to first order.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MR-guided Neurolytic Celiac Plexus Ablation: An Evaluation of Effect and Injection Spread Pattern in Cancer Patients with Celiac Tumor Infiltration

ObjectiveThe purpose of this study was to evaluate the feasibility, the initial accuracy, and the effects of the MR-guided neurolytic celiac plexus ablation as a method to treat cancer-induced chronic abdominal pain. Thirteen celiac plexus ablations were performed for 12 patients. A 0.23-T open MRI scanner with optical navigation was used for procedural guidance. As an adjunct to the MR-guided needle positioning, the needle location was confirmed with saline injection and consequent MR imaging (STIR sequence). The spread of the ablative injection material (alcohol-lidocaine mix) was observed by repeating this sequence after the therapeutic injection. Pain scores from seven patients (eight ablations) were used to assess the therapy effect. MR guidance allowed adequate needle positioning and visualization of injection material in all cases. The rest pain scores significantly decreased from 4 (median) at baseline to 1 (median) at 2 weeks (p < 0.05). Average and worst pain experienced during the past week were significantly lower at the 2-week time point compared with the baseline (p < 0.05). However, the intervention did not result in reduction of opioid use at 2 weeks.MR guidance is an accurate and safe method for celiac plexus ablation with positive therapeutic effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated analysis of X-ray diffraction patterns and pair distribution functions for machine-learned phase identification

Abstract To bolster the accuracy of existing methods for automated phase identification from X-ray diffraction (XRD) patterns, we introduce a machine learning approach that uses a dual representation whereby XRD patterns are augmented with simulated pair distribution functions (PDFs). A convolutional neural network is trained directly on XRD patterns calculated using physics-informed data augmentation, which accounts for experimental artifacts such as lattice strain and crystallographic texture. A second network is trained on PDFs generated via Fourier transform of the augmented XRD patterns. At inference, these networks classify unknown samples by aggregating their predictions in a confidence-weighted sum. We show that such an integrated approach to phase identification provides enhanced accuracy by leveraging the benefits of each model’s input representation. Whereas networks trained on XRD patterns provide a reciprocal space representation and can effectively distinguish large diffraction peaks in multi-phase samples, networks trained on PDFs provide a real space representation and perform better when peaks with low intensity become important. These findings underscore the importance of using diverse input representations for machine learning models in materials science and point to new avenues for automating multi-modal characterization.

36 MATERIALS SCIENCE↗

Atomic-scale combination of germanium-zinc nanofibers for structural and electrochemical evolution

Alloy materials have been emerged to achieve compatible properties in various applications. The structural manipulation, however, requires sensitive and complicated synthetic process. Herein, we report atomic-scale combination of germanium-zinc distorted alloy exhibiting uncertain eutectic point in a phase diagram can imply a great potential to form atomically collaborated array via a simple fabrication method. When interconnected together, it prevents a fatal sublimation of germanium/germanium oxide during gas-solid phase reduction reaction and allows outstanding electronic conductivity as well as high available capacity in lithium-ion batteries, leading to structural and electrochemical evolution of germanium/zinc distorted array. Further, the unique features are clearly confirmed through in situ analysis. Besides, as-prepared battery anodes remarkably highlights outstanding rate capabilities (capacity retention of ~50% at 20 C compared to 0.2 C-rate) and cycle retention (73% at 3.0 C-rate) with a capacity of 546 mAh g -1 even after 1000 cycles. Even when assembled in a full cell, it notably facilitates considerable energy density during 400 cycles with 99.4% of average coulombic efficiency, which is suitable for a large-scale energy storage system.

36 MATERIALS SCIENCE↗

Atomistic study of stability of xenon nanoclusters in uranium oxide

Density-functional theory calculations of the xenon incorporation energies in point defects in urania have been done in order to fit empirical potentials. With this set of parameters, we have considered the incorporation of xenon in small and extended defects such as planar interstitials, grain boundaries, faceted, and spherical voids. The results show that xenon atoms are more likely to aggregate than to be homogeneously distributed in the urania grains. SIGMA5 grain boundary and spherical shape voids are the most favorable defects of xenon atom incorporation. The presence of xenon atoms in nanovoids affects their shape. The energy gain to aggregate xenon atoms into clusters saturates for cluster sizes of about 15-20 Schottky defects. This demonstrates that medium size defects are just as favorable as big size defects for xenon incorporation.

36 MATERIALS SCIENCE↗

Experimental Assessment of a Novel Touchless Interface for Intraprocedural Imaging Review

Purpose: To examine the feasibility of a novel technology platform that enables real-time touchless interaction with radiology images in both a simulated and an actual clinical setting. Materials and Methods: This platform offers three different modes for image interaction. The gesture recognition mode uses a depth camera to detect the user’s hand gestures which are translated to image manipulation commands. The light projection mode uses the same camera to detect finger point-and-tap movements above the icons which are projected on a surface to activate the commands. The capacitive sensing mode is enabled by a handheld, portable device, over which finger movements are detected by capacitive sensors to control the image review. Following initial feedback, light projection and capacitive sensing modes were selected for further testing by comparing with the conventional mode of image interaction in time trials for performing a series of standardized image manipulation tasks. Finally, the usability of the technology platform was examined in actual clinical procedures. Results: The light projection and the capacitive sensing modes were evaluated in the time trials and exhibited 60% and 71% reduction in time, respectively, relative to the control mode (p < 0.001). Clinical feasibility for this platform was demonstrated in three actual interventional radiology cases. Conclusion: Accessing, navigating, and extracting relevant information from patient images intraprocedurally are cumbersome and time-consuming tasks that affect safety, efficiency, and decision-making during image-guided procedures. This study demonstrated that the novel technology addressed this issue by allowing touchless interaction with these images in the sterile field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing the Effects of Nb, Pb, Y, and La Replacement on the Structural, Electrical, and Magnetic Characteristics of Bi-Based Superconductors

In this study, the effects of Pb, Nb, La, and Y replacements were investigated on Bi-based superconducting materials. In preparing the samples, we used a method called solid-state reaction method. The patterns of the X-ray diffraction of all samples indicated presence of Bi-2212 and Bi-2223 phases. The results obtained from XRD revealed that with increase of the melting point of substation elements, the Bi-2223 phase decreased while the Bi-2212 phase and impurity phases of samples grew. From the electrical resistivity measurements using the four-probe method, it was found that sample A with Pb and sample B with La replacements had the maximum and minimum critical temperatures of 111.4 and 81.6 K, respectively. Based on hysteresis loop (M–H) measurement using Bean’s model, estimation of critical current density (J{sub c}) showed that sample A with Pb and sample B with La substitution had the maximum and minimum values respectively. These results may be due to the melting point of these elements with values of 888, 1512, 2315, and 2425 {sup ∘}C for PbO, Nb{sub 2}O{sub 5}, La{sub 2}O{sub 3}, and Y{sub 2}O{sub 3}, respectively. These elements were replaced by Bi{sub 2}O{sub 3} with a melting point of 817 {sup ∘} C. Further, the samples were prepared at the temperature of 845 {sup ∘}C. It seems at this temperature, these elements not only dissolve within the main matrix and participate in the formation of the Bi-2212 phase during the sintering process but they also participate in the development of the variety of the impurity phases as confirmed by XRD results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Long-Term Improvement in Treatment Outcome After Radiotherapy and Hyperthermia in Locoregionally Advanced Cervix Cancer: An Update of the Dutch Deep Hyperthermia Trial

Purpose: The local failure rate in patients with locoregionally advanced cervical cancer is 41-72% after radiotherapy (RT) alone, whereas local control is a prerequisite for cure. The Dutch Deep Hyperthermia Trial showed that combining RT with hyperthermia (HT) improved 3-year local control rates of 41-61%, as we reported earlier. In this study, we evaluate long-term results of the Dutch Deep Hyperthermia Trial after 12 years of follow-up. Methods and Materials: From 1990 to 1996, a total of 114 women with locoregionally advanced cervical carcinoma were randomly assigned to RT or RT + HT. The RT was applied to a median total dose of 68 Gy. The HT was given once weekly. The primary end point was local control. Secondary end points were overall survival and late toxicity. Results: At the 12-year follow-up, local control remained better in the RT + HT group (37% vs. 56%; p = 0.01). Survival was persistently better after 12 years: 20% (RT) and 37% (RT + HT; p = 0.03). World Health Organization (WHO) performance status was a significant prognostic factor for local control. The WHO performance status, International Federation of Gynaecology and Obstetrics (FIGO) stage, and tumor diameter were significant for survival. The benefit of HT remained significant after correction for these factors. European Organization for Research and Treatment of Cancer Grade 3 or higher radiation-induced late toxicities were similar in both groups. Conclusions: For locoregionally advanced cervical cancer, the addition of HT to RT resulted in long-term major improvement in local control and survival without increasing late toxicity. This combined treatment should be considered for patients who are unfit to receive chemotherapy. For other patients, the optimal treatment strategy is the subject of ongoing research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Value of Diffusion-Weighted Magnetic Resonance Imaging for Prediction and Early Assessment of Response to Neoadjuvant Radiochemotherapy in Rectal Cancer: Preliminary Results

Purpose: To evaluate diffusion-weighted magnetic resonance imaging (DWI) for response prediction before and response assessment during and early after preoperative radiochemotherapy (RCT) for locally advanced rectal cancer (LARC). Methods and Materials: Twenty patients receiving RCT for LARC underwent MRI including DWI before RCT, after 10-15 fractions and 1 to 2 weeks before surgery. Tumor volume and apparent diffusion coefficient (ADC; b-values: 0-1000 s/mm{sup 2}) were determined at all time points. Pretreatment tumor ADC and volume, tumor ADC change ( Increment ADC), and volume change ( Increment V) between pretreatment and follow-up examinations were compared with histopathologic findings after total mesorectal excision (pathologic complete response [pCR] vs. no pCR, ypT0-2 vs. ypT3-4, T-downstaging or not). The discriminatory capability of pretreatment tumor ADC and volume, Increment ADC, and Increment V for the detection of pCR was compared with receiver operating characteristics analysis. Results: Pretreatment ADC was significantly lower in patients with pCR compared with patients without (in mm{sup 2}/s: 0.94 {+-} 0.12 Multiplication-Sign 10{sup -3} vs. 1.19 {+-} 0.22 Multiplication-Sign 10{sup -3}, p = 0.003), yielding a sensitivity of 100% and specificity of 86% for detection of pCR. The volume reduction during and after RCT was significantly higher in patients with pCR compared with patients without (in %: {Delta}V{sub during}: -62 {+-} 16 vs. -33 {+-} 16, respectively, p = 0.015; and {Delta}V{sub post}: -86 {+-} 12 vs. -60 {+-} 21, p = 0.012), yielding a sensitivity of 83% and specificity of 71% for the {Delta}V{sub during} and, respectively, 83% and 86% for the {Delta}V{sub post}. The Increment ADC during ({Delta}ADC{sub during}) and after RCT ({Delta}ADC{sub post}) showed a significantly higher value in patients with pCR compared with patients without (in %: {Delta}ADC{sub during}: 72 {+-} 14 vs. 16 {+-} 12, p = 0.0006; and {Delta}ADC{sub post}: 88 {+-} 35 vs. 26 {+-} 19, p = 0.0011), yielding a sensitivity and specificity of 100% for the {Delta}ADC{sub during} and, respectively, 100% and 93% for the {Delta}ADC{sub post}. Conclusions: These initial findings indicate that DWI, using pretreatment ADC, {Delta}ADC{sub during}, and {Delta}ADC{sub post} may be useful for prediction and early assessment of pathologic response to preoperative RCT of LARC, with higher accuracy than volumetric measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Patient Reporting of Symptomatic Adverse Events via the Patient-Reported Outcomes Version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE) in a Chemoradiotherapy Cooperative Group Multicenter Clinical Trial

Purpose: To assess the feasibility of measuring symptomatic adverse events (AEs) in a multicenter clinical trial using the National Cancer Institute's Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE). Methods and Materials: Patients enrolled in NRG Oncology's RTOG 1012 (Prophylactic Manuka Honey for Reduction of Chemoradiation Induced Esophagitis-Related Pain during Treatment of Lung Cancer) were asked to self-report 53 PRO-CTCAE items representing 30 symptomatic AEs at 6 time points (baseline; weekly ×4 during treatment; 12 weeks after treatment). Reporting was conducted via wireless tablet computers in clinic waiting areas. Compliance was defined as the proportion of visits when an expected PRO-CTCAE assessment was completed. Results: Among 226 study sites participating in RTOG 1012, 100% completed 35-minute PRO-CTCAE training for clinical research associates (CRAs); 80 sites enrolled patients, of which 34 (43%) required tablet computers to be provided. All 152 patients in RTOG 1012 agreed to self-report using the PRO-CTCAE (median age 66 years; 47% female; 84% white). Median time for CRAs to learn the system was 60 minutes (range, 30-240 minutes), and median time for CRAs to teach a patient to self-report was 10 minutes (range, 2-60 minutes). Compliance was high, particularly during active treatment, when patients self-reported at 86% of expected time points, although compliance was lower after treatment (72%). Common reasons for noncompliance were institutional errors, such as forgetting to provide computers to participants; patients missing clinic visits; Internet connectivity; and patients feeling “too sick.” Conclusions: Most patients enrolled in a multicenter chemoradiotherapy trial were willing and able to self-report symptomatic AEs at visits using tablet computers. Minimal effort was required by local site staff to support this system. The observed causes of missing data may be obviated by allowing patients to self-report electronically between visits, and by using central compliance monitoring. These approaches are being incorporated into ongoing studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Soft chemistry synthesis of high-crystalline orthogermanate CeGeO{sub 4}: A new photocatalyst

A new orthogermanate phase of CeGeO{sub 4} was studied and the corresponding nanocrystals have been successfully synthesized via a facile hydrothermal method without adding any capping agent. The pH value of the solution and the reaction time were also further investigated, respectively. The as-prepared CeGeO{sub 4} nanocrystals with a uniform size of 15 nm have been characterized by using XRD/TEM/TGA/UV-vis techniques, and their electronic structures and band gap were calculated based on a plane wave density function theory (DFT). The promising photocatalytic properties of CeGeO{sub 4} have been confirmed through monitoring reactive oxidative species generated in photocatalytic reactions of terephthalic acid as a fluorescence probe. - Graphical Abstract: A novel photocatalyst CeGeO{sub 4} was prepared. Highlights: Black-Right-Pointing-Pointer CeGeO{sub 4} as a novel photocatalyst was successfully synthesized by a hydrothermal method. Black-Right-Pointing-Pointer Electronic structure and band gap were calculated based on DFT. Black-Right-Pointing-Pointer CeGeO{sub 4} exhibited a promising photocatalytic performance.

36 MATERIALS SCIENCE↗

Synthesis and crystal structure of Mg{sub 0.5}NbO{sub 2}: An ion-exchange reaction with Mg{sup 2+} between trigonal [NbO{sub 2}]{sup -} layers

A new layered niobate, Mg{sub 0.5}NbO{sub 2}, was synthesized from LiNbO{sub 2} through a cation-exchange reaction with Mg{sup 2+} at 450-550 Degree-Sign C. This is the first example of a topotactic reaction with an aliovalent cation between trigonal [NbO{sub 2}]{sup -} layers. It is proposed to be isostructural with LiNbO{sub 2} (space group; P6{sub 3}/mmc) with lattice parameters of a=2.9052(6) A, c=10.625(15) A. The lattice parameters and formation energy of Mg{sub 0.5}NbO{sub 2} crystallized in LiNbO{sub 2} form and other layered CaNb{sub 2}O{sub 4} one were calculated by density functional theory. - Graphical abstract: A new layered niobate, Mg{sub 0.5}NbO{sub 2}, was synthesized from LiNbO{sub 2} through a cation-exchange reaction with Mg{sup 2+} at 450-550 Degree-Sign C. It is isostructural with LiNbO{sub 2} with lattice parameters of a=2.9052(6) A, c=10.625(15) A. Mg{sup 2+} are described in spheres located between [NbO{sub 2}]{sup -} trigonal layers and its occupancy is 0.5. Highlights: Black-Right-Pointing-Pointer A new layered niobate, Mg{sub 0.5}NbO{sub 2}, was synthesized from LiNbO{sub 2}. Black-Right-Pointing-Pointer Cation-exchange reaction converted two monovalent Li{sup +} into one divalent Mg{sup 2+} at 450-550 Degree-Sign C. Black-Right-Pointing-Pointer Mg{sub 0.5}NbO{sub 2} was isostructural with LiNbO{sub 2} (space group; P6{sub 3}/mmc). Black-Right-Pointing-Pointer Its lattice parameters were a=2.9052(6) A and c=10.625(15) A. Black-Right-Pointing-Pointer Synthesized Mg{sub 0.5}NbO{sub 2} was calculated to be thermodynamically more favorable.

36 MATERIALS SCIENCE↗

ChIMES: A Force Matched Potential with Explicit Three-Body Interactions for Molten Carbon

We present a new force field and development scheme for atomistic simulations of materials under extreme conditions. These models, which explicitly include twoand three-body interactions, are generated by fitting linear combinations of Chebyshev polynomials through force matching to trajectories from Kohn–Sham density functional theory (DFT).We apply our method to liquid carbon near the diamond/graphite/liquid triple point and at higher densities and temperatures, where metallization and manybody effects may be substantial. We show that explicit inclusion of three-body interaction terms allows our model to yield improved descriptions of both dynamic and structural properties over previous empirical potential efforts, while exhibiting transferability to nearby state points. The simplicity of our functional form and subsequent efficiency of parameter determination allows for extension of DFT to experimental time and length scales while retaining most of its accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Springback Analysis of Draw-Bending of 980 MPa Cold Rolled Steel Sheet and Its Experimental Validation

Draw-bending experiment is carried out using a 1.2 mm-thick high strength steel sheet with a tensile strength of 980 MPa and the residual curvature of the draw-bent specimens are precisely measured. The die profile of the draw-bending testing machine rotates, so that the effect of friction force on the curvature data after springback can be neglected. Moreover, in order to quantitatively evaluate the Bauschinger effect of the test material, stress reversal tests are performed using an in-plane stress reversal testing machine. Furthermore, the finite element analyses (FEA) of the draw-bending experiment are carried out. The effect of the work hardening models (isotropic or combined), element types (shell or solid), and the number of integration points in the through-thickness direction on the amount of springback (residual curvature) are investigated in detail.

36 MATERIALS SCIENCE↗