Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Quantum Logic Enhanced Sensing in Solid-State Spin Ensembles

We demonstrate quantum logic enhanced sensitivity for a macroscopic ensemble of solid-state, hybrid two-qubit sensors. We achieve over a factor of 30 improvement in the single-shot signal-to-noise ratio, translating to an ac magnetic field sensitivity enhancement exceeding an order of magnitude for time-averaged measurements. Using the electronic spins of nitrogen vacancy (NV) centers in diamond as sensors, we leverage the on-site nitrogen nuclear spins of the NV centers as memory qubits, in combination with homogeneous and stable bias and control fields, ensuring that all of the ~10 9 two-qubit sensors are sufficiently identical to permit global control of the NV ensemble spin states. We find quantum logic sensitivity enhancement for multiple measurement protocols with varying optimal sensing intervals, including XY8 and DROID-60 dynamical decoupling, as well as correlation spectroscopy, using an applied ac magnetic field signal. The results are independent of the nature of the target signal and broadly applicable to measurements using NV centers and other solid-state spin ensembles. Furthermore, this work provides a benchmark for macroscopic ensembles of quantum sensors that employ quantum logic or quantum error correction algorithms for enhanced sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Parameter Scattering Sensor and Methods

Methods, detectors and systems detect particles and/or measure particle properties. According to one embodiment, a detector for detecting particles comprises: a sensor for receiving radiation scattered by an ensemble of particles; and a processor for determining a physical parameter for the detector, or an optimal detection angle or a bound for an optimal detection angle, for measuring at least one moment or integrated moment of the ensemble of particles, the physical parameter, or detection angle, or detection angle bound being determined based on one or more of properties (a) and/or (b) and/or (c) and/or (d) or ranges for one or more of properties (a) and/or (b) and/or (c) and/or (d), wherein (a)-(d) are the following: (a) is a wavelength of light incident on the particles, (b) is a count median diameter or other characteristic size parameter of the particle size distribution, (c) is a standard deviation or other characteristic width parameter of the particle size distribution, and (d) is a refractive index of particles.

Greenberg, Paul S.↗

Multi-Functional Distributed Fiber Sensors for Pipeline Monitoring and Methane Detections. Final Report

As an abundant and cheap fossil energy source, natural gas has become a significant energy supply to support the United States’ economy. However, the large-scale extraction and utilization of natural gas also impose significant challenges on methane leakage. This problem is exacerbated by aging gas utility delivery systems, including interstate high-pressure pipelines, storage, and transmission facilities. This project aims to develop a cost-effective fiber optical sensing method that can perform multi-parameter real-time measurements of natural gas pipelines across long interrogation distances up to 100 km with 1-meter spatial resolution. This sensing tool can evaluate overall pipeline efficiency and reduce methane emissions for mid-stream methane infrastructures. To accomplish this objective, research and development efforts funded by this project have resulted in the following accomplishments: This project successfully has developed new functional sensory polymer materials using Metal-Organic Frameworks (MOFs) that can be coated on optical fiber through the reel-to-reel coating process. Functional polymer-coated optical fibers can perform sensitive methane detection through evanescence wave interaction and strain-based measurements to achieve 1% detection sensitivities. The new sensors fibers support both distributed measurements and multiplexed fiber sensors array for multi-point measurements. This project developed and optimized a new multi-core optical fiber that supports simultaneous and distributed measurements of strain and temperatures with 1-meter spatial resolutions across up to 100-km interrogation distance. This new fiber, combined with sensory polymercoated fiber, could perform both distributed temperature and methane detections. This project developed a new artificial intelligence big data algorithm approach that can effectively analyze high-resolution data harnessed by distributed fiber sensors to protect natural gas pipelines against external threats and detect internal defects induced by corrosion. Working with our industry partner, this project developed new optical fibers that support fiber sensor fabrications through polymer coating after the fibers are drawn. These new fibers eliminate the need for direct sensor fabrication when the fiber is fabricated on a fiber draw tower, which drastically expands fiber sensors' applicability. This research project has significantly advanced the distributed fiber sensing technology. It will dramatically increase the applicability and adaptability of distributed fiber sensors for a wide array of applications in energy, sustainability, and environmental science, including structural health monitoring of natural gas pipelines, oil infrastructures, hydrogen facilities, and environmental monitoring of carbon storage sites, water supply systems, and others.

03 NATURAL GAS↗

Alternative non-Markovianity measure by divisibility of dynamical maps

By identifying non-Markovianity with nondivisibility, we propose a measure of non-Markovianity for quantum processes. Three examples are presented, and the measure of non-Markovianity is calculated and discussed for these examples. Comparisons with other measures of non-Markovianity are made. The present non-Markovianity measure has the merit that no optimization procedure is required and it is finite for any quantum process, which greatly enhances the practical relevance of the proposed measure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric Field Conjugation in the Presence of Model Uncertainty

The Wide-Field Infrared Survey Telescope (WFIRST) is a 2.4-meter-diameter space telescope NASA program. The payload will include a coronagraph instrument (CGI). The CGI designs under development use deformable mirrors (DM) to create a point spread function (PSF) with a dark region around the obscured star object. Electric field conjugation (EFC) is an iterative nonlinear optimization procedure that uses measurements of the electric field at the image to determine the DM displacements to modify the PSF to create the region of high contrast in the image. EFC requires a numerical model of the coronagraph to calculate the Jacobian of the system, which is used, along with regularization, to solve for the DM displacements for each iteration of the nonlinear optimization. Ideally, the coronagraph is aligned and calibrated, and the calibration data are used in the numerical model for calculating the Jacobian. However, calibration and alignment measurements always contain uncertainty resulting in calibration error. Therefore, the Jacobian calculated from the numerical model is not an exact representation of the physical coronagraph, and the resulting DM solution for an EFC iteration does not have the exact impact on the electric field of the coronagraph as predicted by the EFC. The result is slow convergence, and, as will be shown, drives the use of more restrictive regularization. Using Monte Carlo trials, we investigate the effect of calibration error on EFC convergence and regulatization. Comparison to results from the High Contrast Imaging Testbed Hybrid Lyot Coronagraph are also presented.

Marx, David↗

Optimization of the 15 N 2 incorporation and acetylene reduction methods for free-living nitrogen fixation

To optimize assay conditions of two common methods for measuring potential free-living nitrogen-fixation (FLNF), acetylene reduction assay (ARA) and 15 N 2 -incorporation ( 15 N 2 ), for use with soil/rhizosphere samples. We tested the impact of different carbon (C) sources, oxygen concentrations (O 2 ), and incubation times on FLNF rates of two low-fertility Michigan soils via ARA and 15 N 2 .FLNF rates were greatest with addition of a C cocktail, at low O 2 , and with 7-day incubations for both methods. FLNF via ARA was 1700x greater with a C cocktail versus glucose only and via 15 N 2 was 17x greater with a C cocktail compared to other C sources and no-C controls. Specific O 2 optimum varied by method and site. A 7-day incubation was needed for the ARA, but a 3-day incubation was suitable for 15 N 2 . Lastly, we confirm previously identified issues with the ARA of acetylene-independent ethylene production/consumption resulting in potential FLNF measurement error of 1.3–52.3 μg N g –1 day –1 . Here, we present an optimized method for measuring potential FLNF in soil/rhizosphere samples which will allow for consistent and comparable FLNF rate measurements. Researchers should account for C source, O 2 , and incubation time when assessing FLNF and use the ARA method with caution.

15N2 incorporation↗

An Online Joint Optimization–Estimation Architecture for Distribution Networks

Here in this article, we propose an optimal joint optimization-estimation architecture for distribution networks, which jointly solves the optimal power flow (OPF) problem and static state estimation (SE) problem through an online gradient-based feedback algorithm. The main objective is to enable a fast and timely interaction between the OPF decisions and state estimators with limited sensor measurements. First, convergence and optimality of the proposed algorithm are analytically established. Then, the proposed gradient-based algorithm is modified by introducing statistical information of the inherent estimation and linearization errors for an improved and robust performance of the online OPF decisions. Overall, the proposed method eliminates the traditional separation of operation and monitoring, where optimization and estimation usually operate at distinct layers and different time scales. Hence, it enables a computationally affordable, efficient, and robust online operational framework for distribution networks under time-varying settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active and Durable PGM-free Cathodic Electrocatalysts for Fuel Cell Application

Platinum Group Metal-free (PGM-free) Oxygen Reduction Reaction (ORR) electrocatalysts possess high intrinsic activity measured by a Rotating Disk Electrode (RDE) method. However, under fuel cell operating conditions, PGM-free ORR electrocatalysts have underperformed compared to platinum catalysts. PGM-free ORR electrocatalyst’s fuel cell performance can be improved by designing and optimizing the cathodic catalyst layer (CL) and Membrane Electrode Assembly (MEA) construction such that: 1) it efficiently provides oxygen access to ORR active sites (through catalyst morphology control); 2) it removes water from the CL (by tuning the hydrophobicity of the PGM-free catalysts and the catalyst layer structure); and 3) it increases proton conductivity (by homogeneous mixing of catalysts and ionomer). Studying the CL is complex due to the absence of well-established protocols of MEA activation, especially compared to platinum-containing catalysts. PGM-free fuel cell testing protocols would need to optimize potentiostatic vs galvanostatic measurements, scan rates, parameters of Electrochemical Impedance Spectroscopy (EIS) and Beginning of Experiment (BOE) criteria. To make the PGM-free catalyst’s fuel cell performance comparable to platinum, the synergistic effort of materials design, fine tuning of the catalyst layer and comprehensive electrochemical analysis is required.

08 HYDROGEN↗

Experiences from First Top-Off Injection at the Stanford Synchrotron Radiation Lightsource

As the Stanford Synchrotron Radiation Lightsource (SSRL) of the SLAC National Accelerator Laboratory (SLAC) is moving toward Top-Off injection mode, SLAC's Radiation Protection Department is working with SSRL on minimizing the radiological hazards of this mode. One such hazard is radiation that is created inside the accelerator concrete enclosure by injected beam. Since during Top-Off injection the stoppers that would otherwise isolate the storage ring from the experimental area stay open, the stoppers no longer prevent such radiation from reaching the experimental area. The level of this stray radiation was measured in April 2008 during the first Top-Off injection tests. They revealed radiation dose rates of up to 18 microSv/h (1.8 millirem/h) outside the experimental hutches, significantly higher than our goal of 1 microSv/h (0.1 millirem/h). Non-optimal injection increased the measured dose rates by a factor two. Further tests in 2008 indicated that subsequent improvements by SSRL to the injection system have reduced the dose rates to acceptable levels. This presentation describes the studies performed before the Top-Off tests, the tests themselves and their major results (both under initial conditions and after improvements were implemented), and presents the controls being implemented for full and routine Top-Off injection.

43 PARTICLE ACCELERATORS↗

Edge turbulence measurements in electron-heated Helically Symmetric Experiment plasmas

This paper presents edge measurements utilizing Langmuir probes to characterize plasma turbulence in the Helically Symmetric Experiment (HSX) [F. S. B. Anderson et al., Fusion Technol. 27, 273 (1995)]. Normalized density and potential fluctuations exhibit strong intensities but are comparable to mixing length estimates using measured correlation lengths. The correlation lengths are isotropic with respect to radial and poloidal directions and follow local (gyro-Bohm) drift wave expectations. These observations are common to measurements in both the optimized quasihelically symmetric (QHS) configuration, as well as a configuration where the symmetry is degraded intentionally. The resulting turbulent particle flux in higher density QHS discharges is in good quantitative agreement with transport analysis using three-dimensional neutral gas simulations. The measured turbulence characteristics are compared to a quasilinear trapped electron mode (TEM) drift wave model [H. Nordman, J. Weiland, and A. Jarmen, Nucl. Fusion 30, 983 (1990)] that has been used to predict the anomalous transport in HSX. While quantitative differences exist (factors of 2-3), there is a general consistency between the turbulence measurements and the TEM drift wave model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-Objective PMU Allocation for Resilient Power System Monitoring

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it remains a major challenge to determine the optimal number and location of PMUs. In this paper, a multi-objective resilient PMU placement (MORPP) problem is formulated, and solved by a modified Teaching-Learning-Based optimization (MO-TLBO) algorithm. Three objectives are considered in the MORPP problem, minimizing the number of PMUs, maximizing the system observability, and minimizing the voltage stability index. The effectiveness of the proposed method is validated through testing on IEEE 14-bus, 30-bus, and 118-bus test systems. The advantage of the MO-TLBO-based MORPP is demonstrated through the comparison with other methods in the literature, in terms of iteration number, optimality and time of convergence.

Multi-Objective Optimization↗

Two-dimensional inverse planning and delivery with a preclinical image guided microirradiator

Purpose: Recent advances in preclinical radiotherapy systems have provided the foundation for scaling many of the elements of clinical radiation therapy practice to the dimensions and energy demanded in small animal studies. Such systems support the technical capabilities to accurately deliver highly complex dose distributions, but methods to optimize and deliver such distributions remain in their infancy. This study developed an optimization method based on empirically measured two-dimensional dose kernel measurements to deliver arbitrary planar dose distributions on a recently developed small animal radiotherapy platform.Methods: A two-dimensional dose kernel was measured with repeated radiochromic film measurements for the circular 1 mm diameter fixed collimator of the small animal radiotherapy system at 1 cm depth in a solid water phantom. This kernel was utilized in a sequential quadratic programming optimization framework to determine optimal beam positions and weights to deliver an arbitrary desired dose distribution. The positions and weights were then translated to a set of stage motions to automatically deliver the optimized dose distribution. End-to-end efficacy of the framework was quantified through five repeated deliveries of two dosimetric challenges: (1) a 5 mm radius bullseye distribution, and (2) a “sock” distribution contained within a 9 × 13 mm bounding box incorporating rectangular, semicircular, and exponentially decaying geometric constructs and a rectangular linear dose gradient region. These two challenges were designed to gauge targeting, geometric, and dosimetric fidelity.Results: Optimization of the bullseye and sock distributions required 2.1 and 5.9 min and utilized 50 and 77 individual beams for delivery, respectively. Automated delivery of the resulting optimized distributions, validated using radiochromic film measurements, revealed an average targeting accuracy of 0.32 mm, and a dosimetric delivery error along four line profiles taken through the sock distribution of 3.9%. Mean absolute delivery error across the 0–1 Gy linear dose gradient over 7.5 mm was 0.01 Gy.Conclusions: The work presented here demonstrates the potential for complex dose distributions to be planned and automatically delivered with millimeter scale heterogeneity at submillimeter accuracy. This capability establishes the technical foundation for preclinical validation of biologically guided radiotherapy investigations and development of unique radiobiological experiments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

Improving convergence of the Matrix Power Control Algorithm for random vibration testing

Herein, this paper describes modifications to the Matrix Power Control Algorithm (MPCA) to improve convergence for Random Vibration Control (RVC) testing. In particular, this paper presents Multiple-Input Multiple-Output (MIMO) implementations of MPCA in simulation and experiment. An Euler–Bernoulli beam model was simulated with applied base excitations and the Box Assembly with Removable Component (BARC) was used in experiment to validate results. The Bayesian optimization package Dragonfly was used to optimize control parameters. Additionally, a moving-average was employed and optimized to improve the measured response feedback for MPCA, reduce the number of averages needed to be taken between control updates, and further improve convergence. The key results of this paper show that the performance of MPCA can be improved by tuning the control parameters and by applying an optimized moving-average. Furthermore, it is demonstrated that convergence can be achieved within 12 drive-frames, which greatly enhances vibration control capability.

42 ENGINEERING↗

SU-E-T-278: Realization of Dose Verification Tool for IMRT Plan Based On DPM

Purpose: To build a Monte Carlo dose verification tool for IMRT Plan by implementing a irradiation source model into DPM code. Extend the ability of DPM to calculate any incident angles and irregular-inhomogeneous fields. Methods: With the virtual source and the energy spectrum which unfolded from the accelerator measurement data,combined with optimized intensity maps to calculate the dose distribution of the irradiation irregular-inhomogeneous field. The irradiation source model of accelerator was substituted by a grid-based surface source. The contour and the intensity distribution of the surface source were optimized by ARTS (Accurate/Advanced Radiotherapy System) optimization module based on the tumor configuration. The weight of the emitter was decided by the grid intensity. The direction of the emitter was decided by the combination of the virtual source and the emitter emitting position. The photon energy spectrum unfolded from the accelerator measurement data was adjusted by compensating the contaminated electron source. For verification, measured data and realistic clinical IMRT plan were compared with DPM dose calculation. Results: The regular field was verified by comparing with the measured data. It was illustrated that the differences were acceptable (<2% inside the field, 2–3mm in the penumbra). The dose calculation of irregular field by DPM simulation was also compared with that of FSPB (Finite Size Pencil Beam) and the passing rate of gamma analysis was 95.1% for peripheral lung cancer. The regular field and the irregular rotational field were all within the range of permitting error. The computing time of regular fields were less than 2h, and the test of peripheral lung cancer was 160min. Through parallel processing, the adapted DPM could complete the calculation of IMRT plan within half an hour. Conclusion: The adapted parallelized DPM code with irradiation source model is faster than classic Monte Carlo codes. Its computational accuracy and speed satisfy the clinical requirement, and it is expectable to be a Monte Carlo dose verification tool for IMRT Plan. Strategic Priority Research Program of the China Academy of Science(XDA03040000); National Natural Science Foundation of China (81101132)

60 APPLIED LIFE SCIENCES↗

Two-Spacecraft Orbiting in Opposition to Enable Bistatic Radar Observations Around an Asteroid

Fundamental answers about the origin and evolution of the Solar System hinge on our ability to image in detail the 3D interior structure of small bodies at highresolution. By collecting radar measurements we can ultimately create 3D maps of the interior structure. In this study we focus our attention on a specific mission scenario which consists of a carrier spacecraft and two daughter spacecraft sent to orbit the asteroid Apophis. The orbits of the spacecraft are optimized to maximize radar measurements by dynamically modeling the harmonics and solar radiation pressure. For long mission durations, orbital correction maneuvers maintain the spacecraft in formation.

Anderson, Rodney L.↗