Search NASA⌕ Search

SEARCH · Search NASA

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Data-driven Cyberattack Detection for Photovoltaic (PV) Systems through Analyzing Micro-PMU Data

With increasing exposure to software-based sensing and control, Photovoltaic (PV) systems are facing higher risks of cyber attacks. Here, to ensure the system stability and minimize potential economic losses, it is imperative to monitor operating states and detect attacks at the early stage. To meet this demand, Micro-Phasor Measurement Units (μPMU) are increasingly popular in monitoring distribution networks. However, due to the relatively low sampling rate, μPMU has not yet been used to detect and classify cyber-attacks in power electronics enabled smart grid. To our knowledge, this is one of the first attempts to use μPMU to detect cyber attacks that degrade the performance of power electronics systems. We propose to apply data-driven methods on micro-PMU data to implement attack detection. We have evaluated data-driven methods, including decision tree (DT), K-nearest neighbor (KNN), support vector machine (SVM), artificial neural network (ANN), long short-term memory (LSTM) and convolutional neural network (CNN). The proposed CNN model achieves the required performances with the highest 99.23% accuracy and 0.9963 F 1 score.

14 SOLAR ENERGY↗

NO-LESS: Near optimal curtailment strategy selection for net load balancing in micro grids

The integration of renewable energy sources such as solar PVs into micro grids has increased in recent years. However, the intermittent and unpredictable nature of renewable energy generation makes supply uncertain, in turn requiring continuous net load balancing to ensure grid stability. One technique to achieve net load balancing is curtailment, however, selection of the optimal set of curtailment strategies to achieve a targeted curtailment is NP-hard. State-of-the-art curtailment selection techniques approach this problem by either developing computationally expensive optimal curtailment strategies or reduce accuracy to generate sub-optimal solutions quickly. In this work, we develop NO-LESS: a Near OptimaL CurtailmEnt Strategy Selection algorithm. NO-LESS is a novel Fully Polynomial Time Approximation Scheme (FPTAS) which determines bounded (near optimal) curtailment strategies in a small amount of time while simultaneously satisfying practical constraints on strategy switching overhead and curtailment fairness. We perform both theoretical analysis and practical evaluation to show that NO-LESS is a scalable solution for performing net load balancing through curtailment strategy selection in Micro Grids.

14 SOLAR ENERGY↗

A Micro-scale Numerical Investigation of Internal and Interfacial Void Defects in Adhesive on Failure Behavior of Adhesively-Bonded Materials with Rough Surfaces

This paper studied the effects of air void defects on the failure behavior of adhesively-bonded materials under global shear via micro-scale computational modeling. The numerical results indicated that interfacial void defects can largely facilitate interfacial debonding of a weaker adherend/adhesive interface under shear. However, this is not the case for a stronger adherend/adhesive interface, showing the reduction on the nominal shear strength of an adhesive joint is mainly due to internal void defects. The reduced bonding performance due to voids can be improved by leveraging an appropriate surface roughness. This preliminary investigation is a first step to better understand the micro-mechanics of interfacial failure in the adhesion of a roughened/patterned adherend via surface modification(s) and an adhesive, and also shows the importance of minimizing interfacial void defects in particular at a weaker adherend/adhesive interface via different techniques.

Qiao, Yao↗

Exploring Failure of Adhesively-Bonded Joints with Different Void Sizes at the Same Void Volume Fraction through A Micro-scale Numerical Modeling

This paper studied the effects of void sizes on the failure behavior of adhesively-bonded materials under global shear via micro-scale computational modeling. The numerical results indicate that large void sizes with increased distances between them at the same void volume fraction can alleviate the reduced joint strength of a weaker adherend-adhesive interface caused by interfacial voids. However, this is not the case for an adherend-adhesive interface with the interfacial tensile strength being sufficiently higher than the adhesive strength, showing the negligible effect on the joint strength due to various void sizes and the amount of interfacial voids. This preliminary investigation provides insightful information for scaling up the void size in the macro-scale computational modeling of joints, and enhances the understanding of the micro-mechanical adhesion in adherend-adhesive interfaces with different levels of bonding.

Qiao, Yao↗

Initial investigation on the use of MR spectroscopy and micro-MRI of GAFCHROMIC EBT radiotherapy film

Purpose: This article presents an initial investigation of the efficacy of using {sup 1}H MRS and micro-MRI as analysis techniques for irradiated GAFCHROMIC EBT radiotherapy films. Methods: GAFCHROMIC EBT radiotherapy film was irradiated with 6 MV x rays to known doses ranging from 5 to 1000 cGy. 24 h following irradiation {sup 1}H MRS measurements were performed to access the degree of post-irradiation polymer cross-linking. 2D {sup 1}H micro-MRI experiments were also performed for film irradiations of 0 and 300 cGy. Results: Linear response of the {sup 1}H MRS linewidth to dose in the range from 0 to 400 cGy (R{sup 2}=0.98) was observed. Such linearity is not seen when analyzed under conventional light analysis. The sensitivity of the film, as measured by the slope of the curve between 0 and 400 cGy, is 0.0042{+-}0.0003 kHz/cGy, demonstrating the sensitivity of the {sup 1}H MRS technique used to analyze the film. The film saturates at a dose of approximately 900 cGy. Broadline {sup 1}H MRS provides a quantitative measure of the degree of polymerization of the film. Conclusions: A quantitative measurement of the degree of polymerization of GAFCHROMIC EBT film has been presented using {sup 1}H MRS. The saturation of the film at approximately 900 cGy is corroborated by that observed with light analysis. Further MR spectroscopic experiments are needed to investigate the response of the film to dose, allowing for a better understanding of the relationship between polymer cross-linking in the active layer.

36 MATERIALS SCIENCE↗

Technical Note: Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution

Purpose: The component modules in the standard BEAMnrc distribution may appear to be insufficient to model micro-multileaf collimators that have trifaceted leaf ends and complex leaf profiles. This note indicates, however, that accurate Monte Carlo simulations of radiotherapy beams defined by a complex collimation device can be completed using BEAMnrc's standard VARMLC component module. Methods: That this simple collimator model can produce spatially and dosimetrically accurate microcollimated fields is illustrated using comparisons with ion chamber and film measurements of the dose deposited by square and irregular fields incident on planar, homogeneous water phantoms. Results: Monte Carlo dose calculations for on-axis and off-axis fields are shown to produce good agreement with experimental values, even on close examination of the penumbrae. Conclusions: The use of a VARMLC model of the micro-multileaf collimator, along with a commissioned model of the associated linear accelerator, is therefore recommended as an alternative to the development or use of in-house or third-party component modules for simulating stereotactic radiotherapy and radiosurgery treatments. Simulation parameters for the VARMLC model are provided which should allow other researchers to adapt and use this model to study clinical stereotactic radiotherapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local plate/rod descriptors of 3D trabecular bone micro-CT images from medial axis topologic analysis

Purpose: Trabecular bone microarchitecture is made of a complex network of plate and rod structures evolving with age and disease. The purpose of this article is to propose a new 3D local analysis method for the quantitative assessment of parameters related to the geometry of trabecular bone microarchitecture. Methods: The method is based on the topologic classification of the medial axis of the 3D image into branches, rods, and plates. Thanks to the reversibility of the medial axis, the classification is next extended to the whole 3D image. Finally, the percentages of rods and plates as well as their mean thicknesses are calculated. The method was applied both to simulated test images and 3D micro-CT images of human trabecular bone. Results: The classification of simulated phantoms made of plates and rods shows that the maximum error in the quantitative percentages of plate and rods is less than 6% and smaller than with the structure model index (SMI). Micro-CT images of human femoral bone taken in osteoporosis and early or advanced osteoarthritis were analyzed. Despite the large physiological variability, the present method avoids the underestimation of rods observed with other local methods. The relative percentages of rods and plates were not significantly different between osteoarthritis and osteoporotic groups, whereas their absolute percentages were in relation to an increase of rod and plate thicknesses in advanced osteoarthritis with also higher relative and absolute number of nodes. Conclusions: The proposed method is model-independent, robust to surface irregularities, and enables geometrical characterization of not only skeletal structures but entire 3D images. Its application provided more accurate results than the standard SMI on simple simulated phantoms, but the discrepancy observed on the advanced osteoarthritis group raises questions that will require further investigations. The systematic use of such a local method in the characterization of trabecular bone samples could provide new insight in bone microarchitecture changes related to bone diseases or to those induced by drugs or therapy.

60 APPLIED LIFE SCIENCES↗

Monte Carlo modeling and simulations of the High Definition (HD120) micro MLC and validation against measurements for a 6 MV beam

Purpose: The most recent Varian micro multileaf collimator (MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRC Monte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian Trilogy (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm{sup -3} and an overall leakage of about 1.1 {+-} 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian Trilogy (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte Carlo BEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporal and spectral imaging with micro-CT

Purpose: Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro-CT. Methods: The approach entails a retrospectively gated dual energy scan with optimized filters and voltages, and a series of computational operations to reconstruct the data. Projection interpolation and five-dimensional bilateral filtration (three spatial dimensions + time + energy) are used to reduce noise and artifacts associated with retrospective gating. We reconstruct separate volumes corresponding to different cardiac phases and apply a linear transformation to decompose these volumes into components representing concentrations of water and iodine. Since the resulting material images are still compromised by noise, we improve their quality in an iterative process that minimizes the discrepancy between the original acquired projections and the projections predicted by the reconstructed volumes. The values in the voxels of each of the reconstructed volumes represent the coefficients of linear combinations of basis functions over time and energy. We have implemented the reconstruction algorithm on a graphics processing unit (GPU) with CUDA. We tested the utility of the technique in simulations and applied the technique in an in vivo scan of a C57BL/6 mouse injected with blood pool contrast agent at a dose of 0.01 ml/g body weight. Postreconstruction, at each cardiac phase in the iodine images, we segmented the left ventricle and computed its volume. Using the maximum and minimum volumes in the left ventricle, we calculated the stroke volume, the ejection fraction, and the cardiac output. Results: Our proposed method produces five-dimensional volumetric images that distinguish different materials at different points in time, and can be used to segment regions containing iodinated blood and compute measures of cardiac function. Conclusions: We believe this combined spectral and temporal imaging technique will be useful for future studies of cardiopulmonary disease in small animals.

60 APPLIED LIFE SCIENCES↗

SU-E-T-343: Valencia Applicator Commissioning Using a Micro-Chamber Array

Purpose: In the commissioning and QA of surface isotope-based applicators, source-indexer distance (SID) has a great influence in the flatness, symmetry and output. To these purposes, methods described in the literature are the use of a special insert at the entrance of dwell chamber or radiochromic films. Here we present the experience with a micro-chamber array to perform the commissioning and QA of Valencia applicators. Methods: Valencia applicators have been used, the classic and the new extra-shielded version. A micro-chamber array has been employed, 1000 SRS (PTW), with 977 liquid filled, 2.3×2.3×0.5 mm{sup 3} sized ion chambers covering 11×11 cm{sup 2}, which spacing is 2.5 mm in the central 5.5×5.5 cm{sup 2}, dedicated mainly in principle, in conjunction with Octavius 4D (PTW), to IMRT, VMAT, SBRT verifications. Verisoft software that allows for 3D and planar analysis has been used to evaluate the results. Applicators were located on the surface of the array. To verify the SID, measurements corresponding to the reference value, SID ± 1 mm and SID ± 2 mm were acquired (integration time was fixed in order to discard the influence of the source entrance/exit). Once SID was determined, standard protocol treatments corresponding to 3 Gy and 7 Gy were acquired in order to establish typical patient dose distribution. Results: The method is fast and sensitive. The SID obtained was 1321 mm which is the nominal value included in the applicator manual. For example at 1319 mm an asymmetry of ±8% with respect to the central value was measured, along with a central deviation of −4% referred to 1321 mm. Conclusion: A practical method for the commissioning and QA of Valencia applicators has been described. It has been shown that it is an efficient and accurate tool for these purposes as well as for the verification of the absolute output constancy.

60 APPLIED LIFE SCIENCES↗

WE-F-16A-04: Micro-Irradiator Treatment Verification with High-Resolution 3D-Printed Rodent-Morphic Dosimeters

Purpose: Pre-clinical micro-radiation therapy studies often utilize very small beams (∼0.5-5mm), and require accurate dose delivery in order to effectively investigate treatment efficacy. Here we present a novel high-resolution absolute 3D dosimetry procedure, capable of ∼100-micron isotopic dosimetry in anatomically accurate rodent-morphic phantoms Methods: Anatomically accurate rat-shaped 3D dosimeters were made using 3D printing techniques from outer body contours and spinal contours outlined on CT. The dosimeters were made from a radiochromic plastic material PRESAGE, and incorporated high-Z PRESASGE inserts mimicking the spine. A simulated 180-degree spinal arc treatment was delivered through a 2 step process: (i) cone-beam-CT image-guided positioning was performed to precisely position the rat-dosimeter for treatment on the XRad225 small animal irradiator, then (ii) treatment was delivered with a simulated spine-treatment with a 180-degree arc with 20mm x 10mm cone at 225 kVp. Dose distribution was determined from the optical density change using a high-resolution in-house optical-CT system. Absolute dosimetry was enabled through calibration against a novel nano-particle scintillation detector positioned in a channel in the center of the distribution. Results: Sufficient contrast between regular PRESAGE (tissue equivalent) and high-Z PRESAGE (spinal insert) was observed to enable highly accurate image-guided alignment and targeting. The PRESAGE was found to have linear optical density (OD) change sensitivity with respect to dose (R{sup 2} = 0.9993). Absolute dose for 360-second irradiation at isocenter was found to be 9.21Gy when measured with OD change, and 9.4Gy with nano-particle detector- an agreement within 2%. The 3D dose distribution was measured at 500-micron resolution Conclusion: This work demonstrates for the first time, the feasibility of accurate absolute 3D dose measurement in anatomically accurate rat phantoms containing variable density PRESAGE material (tissue equivalent and bone equivalent). This method enables precise treatment verification of micro-radiation therapies, and enhances the robustness of tumor radio-response studies. This work was supported by NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

Gravity from micro-equilibration

We suggest a mechanism for the emergence of classical dynamical spacetime from an underlying quantum gravitational system. This is an example of a more general process, which we name micro-equilibration, and which can be thought of as local thermalization of entanglement. Applied in the context of the AdS/CFT correspondence, we propose that this dynamical process underlies generic evolution towards CFT states whose gravitational dual describes smooth bulk geometries. Hence, contrary to common expectation, such “geometric” CFT states are in fact typical in this sense. Correspondingly, they can be characterized by a specific universal entanglement structure resulting from micro-equilibration of a generic quantum state.

Astronomy & Astrophysics↗

Critical Review of Fluid Flow Physics at Micro‐ to Nano‐scale Porous Media Applications in the Energy Sector

While there is a consensus in the literature that embracing nanodevices and nanomaterials helps in improving the efficiency and performance, the reason for the better performance is mostly subscribed to the nanosized material/structure of the system without sufficiently acknowledging the role of fluid flow mechanisms in these systems. This is evident from the literature review of fluid flow modeling in various energy‐related applications, which reveals that the fundamental understanding of fluid transport at micro‐ and nanoscale is not adequately adapted in models. Incomplete or insufficient physics for the fluid flow can lead to untapped potential of these applications that can be used to increase their performance. This paper reviews the current state of research for the physics of gas and liquid flow at micro‐ and nanoscale and identified critical gaps to improve fluid flow modeling in four different applications related to the energy sector. The review for gas flow focuses on fundamentals of gas flow at rarefied conditions, the velocity slip, and temperature jump conditions. The review for liquid flow provides fundamental flow regimes of liquid flow, and liquid slip models as a function of key modeling parameters. The four porous media applications from energy sector considered in this review are (i) electrokinetic energy conversion devices, (ii) membrane‐based water desalination through reverse osmosis, (iii) shale reservoirs, and (iv) hydrogen storage, respectively. Review of fluid flow modeling literature from these applications reveals that further improvements can be made by (i) modeling slip length as a function of key parameters, (ii) coupling the dependency of wettability and slip, (iii) using a reservoir‐on‐chip approach that can enable capturing the subcontinuum effects contributing to fluid flow in shale reservoirs, and (iv) including Knudsen diffusion and slip in the governing equations of hydrogen gas storage.

Singh, Harpreet (ORCID:0000000276185764)↗

Characterization of micro-sandwich structures via direct ink writing epoxy based cores

Sandwich structured (SS) composites demonstrate considerable flexural stiffness and high strength-to-weight ratios and can be tailored as functional materials. Historically they have been constrained to specific material types and geometry due to limitations in manufacturing methods. However, employing additive manufacturing (AM), specifically direct ink writing (DIW), can provide an alternative method for making SS composites with complex and controllable micro and mesostructures with multifunctionality targeted at desired mechanical, thermal, and electrical properties. DIW, an extrusion-based AM technique, uses a viscous and thixotropic ink with desired components that, once printed, is cured to obtain the final complex net shape parts. In this paper, a novel hybrid AM technique is employed to manufacture SS composite materials containing bisphenol A-based epoxy core and carbon fiber reinforced polymer (CFRP) face sheets that are fabricated via DIW and vacuum infusion process (VIP), respectfully. We demonstrate that the fabrication of these SS composites can be tailored from a thermosetting material, from which additives and/or various lattice structures can be manufactured to achieve enhanced and desirable mechanical integrity with functional properties. Surface topology and mechanical testing techniques are used to characterize the fabricated hybrid SS composites to study and assess mechanical stability. A rheo-kinetic cure model was developed for the core material to allow for additive manufacturing process requirements while ensuring complete cross-linking for the thermoset-based core material. Because of the ability to obtain relatively small core-thickness and controlled architecture, this method now allows for fabricating layered micro-sandwich structures for realizing further light-weighting in relevant applications.

36 MATERIALS SCIENCE↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

Radiative cooling textiles using industry-standard particle-free nonporous micro-structured fibers

Abstract Thermal radiation is a major dissipative pathway for heat generated by the human body and offers a significant thermoregulation mechanism over a wide range of conditions. We could use this in garment design to enhance personal cooling, which can improve the wearing comfort of garments or even result in energy savings in buildings. At present, however, radiative cooling has received insufficient attention in commercial design and production of textiles for wearable garments. Textiles that efficiently transmit the radiative heat were recently demonstrated, but either do not utilize standard weaving and knitting processes for wearable garments or require substantial process modifications. Here, we demonstrate the design and implementation of large-scale radiative cooling textiles for localized cooling management and enhanced thermal comfort using industry-standard particle-free nonporous micro-structured fibers that are fully compatible with standard textile materials and production methods. The micro-structured fibers, yarns and fabrics are part of a hierarchical photonic structure design that renders the textiles highly infrared transparent (up to > 0.8) while assuring visual opacity (up to 0.99). We design radiative cooling textiles with first-principles electromagnetic methods and fabricate them using commercial textile materials and formation facilities. Our “fabless” approach is confirmed by very good quantitative agreement between design and measurements. The resulting fabrics exhibit wearability properties expected of wearable textiles, and lower skin temperature by ≥ 3 °C compared to conventional textiles, which offers the potential for > 30 % energy savings in buildings and increases wearing comfort by significantly reducing the reliance on latent heat dissipation for thermoregulation.

Catrysse, Peter B.↗

Microstructure Evolution in Ion-Irradiated Oxidized Zircaloy-4 Studied with Synchrotron Radiation Microdiffraction and Transmission Electron Microscopy

The corrosion process (oxidation and hydriding) of zirconium alloy fuel cladding is one of the limiting factors on fuel rod lifetime, particularly for Zircaloy-4. The corrosion rate of this alloy shows indeed a great acceleration at high burnup in light water reactors (LWRs). Understanding the corrosion behavior under irradiation for this alloy is an important technological issue for the safety and efficiency of LWRs. In particular, understanding the effect of irradiation on the metal and oxide layers is a key parameter in the study of corrosion behavior of zirconium alloys. In this study, Zircaloy-4 samples underwent helium and proton ion irradiation up to 0.3 dpa, forming a uniform defect distribution up to 1 pm deep. Both as-received and precorroded samples were irradiated to compare the effect of metal irradiation to that of oxide layer irradiation. After irradiation, samples were corroded to study the impact of irradiation defects in the metal and in preexisting oxide layers on the formation of new oxide layers. Synchrotron X-ray microdiffraction and microfluorescence were used to follow the evolution of oxide crystallographic phases, texture, and stoichiometry both in the metal and in the oxide. In particular, the tetragonal oxide phase fraction, which has been known to play an important role in corrosion behavior, was mapped in both unirradiated and irradiated metals at the submicron scale and appeared to be significantly affected by irradiation. These observations, complemented with electron microscopy analyses on samples in carefully chosen areas of interest, were combined to fully characterize changes caused by irradiation in metal and oxide phases of both alloys.

ion-irradiation↗

Synthetic Biology in Aqueous Compartments at the Micro- and Nanoscale

Aqueous two-phase systems and related emulsion-based structures defined within micro- and nanoscale environments enable a bottom-up synthetic biological approach to mimicking the dynamic compartmentation of biomaterial that naturally occurs within cells. Model systems we have developed to aid in understanding these phenomena include on-demand generation and triggering of reversible phase transitions in ATPS confined in microscale droplets, morpho-logical changes in networks of femtoliter-volume aqueous droplet interface bilayers (DIBs) formulated in microfluidic channels, and temperature-driven phase transitions in interfacial lipid bilayer systems supported on micro and nanostructured substrates. For each of these cases, the dynamics were intimately linked to changes in the chemical potential of water, which becomes increasingly susceptible to confinement and crowding. At these length scales, where interfacial and surface areas predominate over compartment volumes, both evaporation and osmotic forces become enhanced relative to ideal dilute solutions. Finally, consequences of confinement and crowding in cell-sized microcompartments for increasingly complex scenarios will be discussed, from single-molecule mobility measurements with fluorescence correlation spectroscopy to spatio-temporal modulation of resource sharing in cell-free gene expression bursting.

59 BASIC BIOLOGICAL SCIENCES↗