Self-Driving Microscopy for AI/ML-Enabled Physics Discovery and Materials Optimization

Materials are the bedrock of economy and foundation for all real-world technologies. The viability of space travel, grid energy storage, solar to fuels conversion, methane removal, and photovoltaic energy solutions hinge on the discovery and optimization of novel materials and rapid scaling toward manufacturing. The last 20 years have seen an exponential growth in the theoretical predictive capability for crystalline materials and small molecules. However, it is only in the last five years that we have seen the rapid expansion of high-throughput synthesis enabled by laboratory robotics and microfluidics, as well as a resurgence of combinatorial synthesis (Abolhasani and Kumacheva 2023; Epps and Abolhasani 2021; Jiang et al. 2022; Rajan 2008; Soldatov et al. 2021; Szymanski et al. 2023). Combinatorial synthesis, microfluidics, and ultimately dip-pen megalibraries have demonstrated the ability to “write” multicomponent nanomaterials at high throughput scale, generating millions of material examples in the 3D, 4D, and 5D composition spaces (Chen et al. 2016, 2019; Jibril et al. 2022).

36 MATERIALS SCIENCE↗

Protein detection system

The present embodiment describes a miniature, microfluidic, absorption-based sensor to detect proteins at sensitivities comparable to LIF but without the need for tagging. This instrument utilizes fiber-based evanescent-field cavity-ringdown spectroscopy, in combination with faceted prism microchannels. The combination of these techniques will increase the effective absorption path length by a factor of 10.sup.3 to 10.sup.4 (to .about.1-m), thereby providing unprecedented sensitivity using direct absorption. The coupling of high-sensitivity absorption with high-performance microfluidic separation will enable real-time sensing of biological agents in aqueous samples (including aerosol collector fluids) and will provide a general method with spectral fingerprint capability for detecting specific bio-agents.

47 OTHER INSTRUMENTATION↗

Module-Fluidics: Building Blocks for Spatio-Temporal Microenvironment Control

Generating the desired solute concentration signal in micro-environments is vital to many applications ranging from micromixing to analyzing cellular response to a dynamic microenvironment. We propose a new modular design to generate targeted temporally varying concentration signals in microfluidic systems while minimizing perturbations to the flow field. The modularized design, here referred to as module-fluidics, similar in principle to interlocking toy bricks, is constructed from a combination of two building blocks and allows one to achieve versatility and flexibility in dynamically controlling input concentration. The building blocks are an oscillator and an integrator, and their combination enables the creation of controlled and complex concentration signals, with different user-defined time-scales. We show two basic connection patterns, in-series and in-parallel, to test the generation, integration, sampling and superposition of temporally-varying signals. All such signals can be fully characterized by analytic functions, in analogy with electric circuits, and allow one to perform design and optimization before fabrication. Such modularization offers a versatile and promising platform that allows one to create highly customizable time-dependent concentration inputs which can be targeted to the specific application of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗

DIY 3D Microparticle Generation from Next Generation Optofluidic Fabrication

Abstract Complex‐shaped microparticles can enhance applications in drug delivery, tissue engineering, and structural materials, although techniques to fabricate these particles remain limited. A microfluidics‐based process called optofluidic fabrication that utilizes inertial flows and ultraviolet polymerization has shown great potential for creating highly 3D‐shaped particles in a high‐throughput manner, but the particle dimensions are mainly at the millimeter scale. Here, a next generation optofluidic fabrication process is presented that utilizes on‐the‐fly fabricated multiscale fluidic channels producing customized sub‐100 µm 3D‐shaped microparticles. This flexible design scheme offers a user‐friendly platform for rapid prototyping of new 3D particle shapes, providing greater potential for creating impactful engineered microparticles.

3D microparticles↗

Current–Induced Ion Concentration Polarization at a Perfect Ion–Exchange Patch in an Infinite Insulating Wall

This research examines theoretically the ion concentration polarization, ion fluxes, and electrostatic fields near an ion exchange patch in the wall of an electrified fluidic channel. These phenomena are important in related microfluidic ion-preconcentration systems. Under an electric field, counterions enter the ion-exchange patch at one side and leave at the other, with salt depletion occurring near the entrance and accumulation near the exit. Furthermore, the high patch conductivity and the concentration profiles lead to local electric field perturbations that may facilitate preconcentration. This study includes analytical expressions of ion concentrations and electrochemical potentials at small to moderate electric fields, as well as numerical simulations. Additionally, a simple matrix of polynomial coefficients (obtained via fitting of numerical data) enables analytical calculation of the 2-dimensional concentration profiles at all electric fields within the range investigated in the numerical simulations. This is possible because a single dimensionless parameter controls this problem.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cation-Specific Electrokinetic Separations Using Prussian Blue Intercalation Reactions

In this work, we report a new approach for forming ion depletion zones (IDZs) using intercalation reactions at an electrochemically controlled Prussian blue (PB) film. The experiments described here were performed using a microfluidic device, wherein a charged fluorophore in solution was used as a proxy to monitor IDZ formation. In the presence of K + , intercalation reactions proceed readily to form an IDZ, and thus enrich the fluorophore up to 37-fold. In the presence of the larger hydrated Li + or tetrabutylammonium (TBA + ) ions, however, ion intercalation proceeded less quickly than with K + . Slower ion intercalation resulted in a weaker IDZ and correspondingly lower enrichment factors of eight- and six-fold, respectively. These results are significant because they show that PB intercalation reactions selectively form an IDZ. Accordingly, we anticipate that these findings will lead to a better understanding and further interesting applications of intercalation materials like PB for efficient and selective enrichment and separations.

99 GENERAL AND MISCELLANEOUS↗

Enriching Cations Using Electric Field Gradients Generated by Bipolar Electrodes in the Absence of Buffer

We discuss that ionic current gradients and corresponding electric field gradients formed at bipolar electrodes are useful for enriching cations up to ~350-fold at specific locations in microfluidic devices. The enrichment mechanism is determined by collecting current data, measuring solution conductivity, and by performing pH indicator experiments. These data reveal the dynamic nature of the enrichment mechanism. Specifically, they show the complex relationship between the ionic current gradients formed at the bipolar electrode and the extent of cation enrichment. Finally, we demonstrate cation enrichment is possible in buffer-free solutions containing up to 50.0 mM KCl. This finding is significant because it broadens the range of solutions in which membrane-free, electrochemical separations using bipolar electrodes can be performed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Novel volumetric method for highly repeatable injection in microchip electrophoresis

A novel injector for microchip electrophoresis (MCE) has been designed and evaluated that achieves very high repeatability of injection volume suitable for quantitative analysis. It eliminates the injection biases in electrokinetic injection and the dependence on pressure and sample properties in hydrodynamic injection. The microfluidic injector, made of poly(dimethylsiloxane) (PDMS), operates similarly to an HPLC injection valve. It contains a channel segment (chamber) with a well-defined volume that serves as an “injection loop”. Using on-chip microvalves, the chamber can be connected to the sample source during the “loading” step, and to the CE separation channel during the “injection” step. Once the valves are opened in the second state, electrophoretic potential is applied to separate the sample. For evaluation and demonstration purposes, the microinjector was connected to a 75 μm ID capillary and UV absorbance detector. For single compounds, a relative standard deviation (RSD) of peak area as low as 1.04% (n = 11) was obtained, and for compound mixtures, RSD as low as 0.40% (n = 4) was observed. Using the same microchip, the performance of this new injection technique was compared to hydrodynamic injection and found to have improved repeatability and less dependence on sample viscosity. Furthermore, a non-radioactive version of the positron-emission tomography (PET) imaging probe, FLT, was successfully separated from its known 3 structurally-similar byproducts with baseline resolution, demonstrating the potential for rapid, quantitative analysis of impurities to ensure the safety of batches of short-lived radiotracers. Both the separation efficiency and injection repeatability were found to be substantially higher when using the novel volumetric injection approach compared to electrokinetic injection (performed in the same chip). This novel microinjector provides a straightforward way to improve the performance of hydrodynamic injection and enables extremely repeatable sample volume injection in MCE. It could be used in any MCE application where volume repeatability is needed, including the quantitation of impurities in pharmaceutical or radiopharmaceutical samples.

60 APPLIED LIFE SCIENCES↗

On the competition between mixing rate and uniformity in a coaxial hydrodynamic focusing mixer

Fast microfluidic mixers for use with line-of-sight integrating detection schemes pose unique challenges. Such detectors typically cannot discriminate signal from slow moving (e.g. near internal walls) and fast-moving portions of the fluid stream. This convolves reaction rate dynamics with fluid flow residence time dynamics. Further, the small cross sections of typical three-dimensional hydrodynamic focusing devices lead to lower detection signals. The current study focuses on achieving both small time scales of mixing and homogenous residence times. This is achieved by injecting sample through a center capillary and hydrodynamically focusing using a sheath flow within a tapered second capillary. The current design also features a third, larger coaxial capillary. The mixed stream flows into the large cross-section of this third capillary to decelerate and expand the stream by up to 14-fold to improve line-of-sight signal strength of reaction products. Hydrodynamic focusing, mixing, and expansion are studied using analytical and numerical models and also studied experimentally using a fluorescein-iodide quenching reaction. The experimentally validated models are used to explore trade-offs between mixing rate and uniformity. For the first time, this work presents detailed analysis of the Lagrangian time history of species transport during mixing inside coaxial capillaries to measure mixing nonuniformity. The mixing region enables order 100 μs mixing times and residence time widths of the same order (140 μs).

42 ENGINEERING↗

Automated concentration of [ 18 F]fluoride into microliter volumes

Concentration of [ 18 F]fluoride has been mentioned in literature, however, reports have lacked details about system designs, operation, and performance. Here, we describe in detail a compact, fast, fully-automated concentration system based on a micro-sized strong anion exchange cartridge. The concentration of radionuclides enables scaled-up microfluidic synthesis. Our system can also be used to provide highly concentrated [ 18 F]fluoride with minimal water content. We demonstrate how the concentrator can produce varying concentrations of [ 18 F]fluoride for the macroscale synthesis of N-boc-5-[ 18 F]fluoroindole without an azeotropic drying process, while enabling high starting radioactivity. By appropriate choice of solid-phase resin, flow conditions, and eluent solution, we believe this approach can be extended beyond [ 18 F]fluoride to other radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupling between DNA replication, segregation, and the onset of constriction in Escherichia coli

Escherichia coli cell cycle features two critical cell-cycle checkpoints: initiation of replication and the onset of constriction. While the initiation of DNA replication has been extensively studied, it is less clear what triggers the onset of constriction and when exactly it occurs during the cell cycle. Here, using high-throughput fluorescence microscopy in microfluidic devices, we determine the timing for the onset of constriction relative to the replication cycle in different growth rates. Our single-cell data and modeling indicate that the initiation of constriction is coupled to replication-related processes in slow growth conditions. Furthermore, our data suggest that this coupling involves the mid-cell chromosome blocking the onset of constriction via some form of nucleoid occlusion occurring independently of SlmA and the Ter linkage proteins. This work highlights the coupling between replication and division cycles and brings up a new nucleoid mediated control mechanism in E. coli.

59 BASIC BIOLOGICAL SCIENCES↗

Study on coalescence dynamics of unequal-sized microbubbles captive on solid substrate

The dynamics of bubble coalescence are of importance for a number of industrial processes, in which the size inequality of the parent bubbles plays a significant role in mass transport, topological change and overall motion. In this study, coalescence of unequal-sized microbubbles captive on a solid substrate was observed from cross-section view using synchrotron high-speed imaging technique and a microfluidic gas generation device. The bridging neck growth and surface wave propagation at the early stage of coalescence were investigated by experimental and numerical methods. The results show that theoretical half-power-law of neck growth rate is still valid when viscous effect is neglected. However, the inertial-capillary time scale is associated with the initial radius of the smaller parent microbubble. Furthermore the surface wave propagation rate on the larger parent microbubble is proportional to the inertial-capillary time scale.

42 ENGINEERING↗

Insight into industrial hemp ( Cannabis sativa L.) root exudation composition in a simulated soil environment: a rhizosphere-on-a-chip study

Microfluidic technologies provide a reduced complexity and soil-free environment to study plant-soil interactions at the microscale. Traditionally used for model plants such as Arabidopsis thaliana, this study represents the first application of a rhizosphere-on-a-chip (RhizoChip) to investigate root exudation in industrial hemp (Cannabis sativa L.), an agronomic crop with growing economic importance. By incorporating soil-like minerals (kaolinite, potassium feldspar, and biotite), the RhizoChip addresses limitations of previous research. Hemp seedlings grown in mineral-containing chips exhibited significant root growth, emphasizing the critical role of minerals in root development. Using untargeted metabolomics, 170 compounds were identified, including organic acids, amino acids, and secondary metabolites, with distinct profiles across conditions. Metabolic pathway analysis revealed activity in amino acid metabolism, the citric acid cycle, and secondary metabolite biosynthesis. In conclusion, this study highlights the RhizoChip's potential for long-term studies of root exudates in non-model crops and offers insights into rhizosphere processes with implications for sustainable agriculture.

59 BASIC BIOLOGICAL SCIENCES↗

Acoustic focusing of microplastics in microfabricated and steel tube devices: An experimental study on the effects from particle size and medium density

The contamination of aquatic systems with microplastics is becoming a severe threat to living organisms. Microplastics found in the environment consist of a wide range of particle sizes thus give rise to several challenges to current purification methods. Acoustic focusing has been utilized as a particle concentrating method in biological and non-biological applications. In this study, we investigate the feasibility of using acoustic focusing technology to isolate microplastics in aqueous samples and find that a two-stage mechanism is essential to concentrate microplastics of wide size ranges of the same material. We demonstrate for the first time experimentally that when the particle size is comparable to the resonance wavelength, they deviate from typical pressure nodal focusing and show pressure antinodal focusing. Further, we have expanded microplastics isolation beyond microfluidic systems and demonstrate their extraction capabilities relatively at higher flow rates using microplastics of polystyrene, polyethylene, and polymethyl methacrylate ranging from 6 µm to 300 µm diameter and in devices fabricated with cylindrical steel tubes. We could extract 70% of microplastics smaller than 180 µm and 82% of microplastics greater than 180 µm in diameter from an aqueous sample at a flow rate of 12 mL/min. In conclusion, we demonstrate that small microplastics focus on acoustic pressure nodes regardless of the medium density. However, focusing of large microplastics of the same material depends on the medium density.

42 ENGINEERING↗

Brain-implantable multifunctional probe for simultaneous detection of glutamate and GABA neurotransmitters

We report Glutamate (GLU) and gamma-aminobutyric acid (GABA) are neurotransmitters (NTs) with an essential role in signal transmission in the brain. Brain disorders, such as epilepsy, Alzheimer's and Parkinson's diseases, and traumatic brain injury can be linked to imbalances in the GLU-GABA homeostasis that occurs in sub-second to seconds time frames. Current measurement techniques can detect these two NT concentrations simultaneously only in vitro. The present work reports on the fabrication of a silicon multifunctional biosensor microarray probe for sub-second simultaneous GLU-GABA detection in real-time, with excellent analyte sensitivity and selectivity and in vivo capabilities. The novel Si probes feature four surface-functionalized platinum ultramicroelectrodes (UMEs) for simultaneous amperometric detection of GLU and GABA with a sentinel, and a built-in microfluidic channel for the introduction of neurochemicals in the proximity of the UMEs. The microchannel also allows functioning of an On-Demand In-situ Calibrator that runs in-situ biosensor calibration. The probe exhibited excellent robustness at insertion in agarose-gel brain-tissue-mimicking test, and remarkably high hydrogen peroxide sensitivity (a by-product of GLU-GABA enzyme biosensor) with values on the order of 5000 nA μM -1 cm -2 and maximum sensitivities of 204 ± 15 nA μM -1 cm -2 and 37 ± 7 nA μM -1 cm -2 for GLU and GABA, respectively. Furthermore, the limit of detection of the biosensors reached as low as 7 nM, 165 nM and 750 nM for H 2 O 2 , GLU and GABA, respectively and a temporal resolution of hundreds of milliseconds during in vivo studies using freely moving rats.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dissolution of a cylindrical disk in Hele-Shaw flow: a conformal-mapping approach

Here we apply conformal mapping to find the evolving shapes of a dissolving cylinder in a potential flow. Similar equations can be used to describe melting in a flowing liquid phase. Results are compared with microfluidic experiments and numerical simulations. Shapes predicted by conformal mapping agree almost perfectly with experimental observations, after a modest (20 %) rescaling of the time. Finite-volume simulations show that the differences with experiment are connected to the underlying assumptions of the analytical model: potential flow and diffusion-limited dissolution. Approximate solutions of the equations describing the evolution of the shape of the undissolved solid can be derived from a Laurent expansion of the mapping function from the unit circle. Asymptotic expressions for the evolution of the area of the disk and the shift in its centre of mass have been derived at low and high Péclet number. Analytic approximations to the leading-order Laurent coefficients provide additional insight into the mechanisms underlying pore-scale dissolution.

58 GEOSCIENCES↗