Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modeling and Performance Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Discovery and characterization of two Neptune-mass planets orbiting HD 212729 with TESS

ABSTRACT We report the discovery of two exoplanets orbiting around HD 212729 (TOI 1052, TIC 317060587), a Teff = 6146 K star with V = 9.51 observed by TESS in Sectors 1 and 13. One exoplanet, TOI-1052b, is Neptune-mass and transits the star, and an additional planet TOI-1052c is observed in radial velocities but not seen to transit. We confirm the planetary nature of TOI-1052b using precise radial velocity observations from HARPS and determined its parameters in a joint RV and photometry analysis. TOI-1052b has a radius of $2.87^{+0.29}_{-0.24}$ R⊕, a mass of 16.9 ± 1.7 M⊕, and an orbital period of 9.14 d. TOI-1052c does not show any transits in the TESS data, and has a minimum mass of $34.3^{+4.1}_{-3.7}$ M⊕ and an orbital period of 35.8 d, placing it just interior to the 4:1 mean-motion resonance. Both planets are best fit by relatively high but only marginally significant eccentricities of $0.18^{+0.09}_{-0.07}$ for planet b and $0.24^{+0.09}_{-0.08}$ for planet c. We perform a dynamical analysis and internal structure model of the planets as well as deriving stellar parameters and chemical abundances. The mean density of TOI-1052b is $3.9^{+1.7}_{-1.3}$ g cm−3 consistent with an internal structure similar to Neptune. A nearby star is observed in Gaia DR3 with the same distance and proper motion as TOI-1052, at a sky projected separation of $\scriptstyle \sim$1500 au, making this a potential wide binary star system.

Armstrong, David J. (ORCID:0000000250804117)↗

Flatbands and Perfect Metal in Trilayer Moiré Graphene

We investigate the electronic structure of a twisted multilayer graphene system forming a moiré pattern. We consider small twist angles separating the graphene sheets and develop a low-energy theory to describe the coupling of Dirac Bloch states close to the K point in each individual plane. Extending beyond the bilayer case, we show that, when the ratio of the consecutive twist angles is rational, a periodicity emerges in quasimomentum space with moiré Bloch bands even when the system does not exhibit a crystalline lattice structure in real space. For a trilayer geometry, we find flatbands in the spectrum at certain rotation angles. Performing a symmetry analysis of the band model for the trilayer, we prove that the system is a perfect metal in the sense that it is gapless at all energies. Furthermore, this striking result originates from the three Dirac cones which can only gap in pairs and produce bands with an infinite connectivity. It also holds quite generally for multilayer graphene with an odd number of planes under the condition of C 2z T symmetry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Generating Performance Models for Irregular Applications

Many applications have irregular behavior --- non-uniform input data, input-dependent solvers, irregular memory accesses, unbiased branches --- that cannot be captured using today's automated performance modeling techniques. We describe new hierarchical critical path analyses for the \Palm model generation tool. To create a model's structure, we capture tasks along representative MPI critical paths. We create a histogram of critical tasks with parameterized task arguments and instance counts. To model each task, we identify hot instruction-level sub-paths and model each sub-path based on data flow, instruction scheduling, and data locality. We describe application models that generate accurate predictions for strong scaling when varying CPU speed, cache speed, memory speed, and architecture. We present results for the Sweep3D neutron transport benchmark; Page Rank on multiple graphs; Support Vector Machine with pruning; and PFLOTRAN's reactive flow/transport solver with domain-induced load imbalance.

analytical performance models↗

L-VISP: LSTM Visualization for Interpretable Symptom Prediction in Patient Cohorts

Symptom modelling in head and neck cancer is challenged by the complexity of heterogeneous patient data, leading to an interest in deep learning approaches. Although Long Short-Term Memory Networks (LSTMs) have shown great results in patient risk prediction, their low interpretability requires data modellers to collaborate with clinical experts to validate the results. We present L-VISP, a human–machine solution that uses visual analytics for LSTM modelling in clinical research. L-VISP uses custom visual encodings to make multiple LSTM variants interpretable, supporting a full range of analysis, from understanding model operations and evaluating performance to interpreting results in a clinical context. We evaluate L-VISP with data modellers and a clinical oncologist and present the takeaways from this multidisciplinary collaboration.

LSTM modeling↗

Surrogate Modeling of Nonlinear Dynamic Systems: A Comparative Study

Surrogate models play a vital role in overcoming the computational challenge in designing and analyzing nonlinear dynamic systems, especially in the presence of uncertainty. This paper presents a comparative study of different surrogate modeling techniques for nonlinear dynamic systems. Four surrogate modeling methods, namely, Gaussian process (GP) regression, a long short-term memory (LSTM) network, a convolutional neural network (CNN) with LSTM (CNN-LSTM), and a CNN with bidirectional LSTM (CNN-BLSTM), are studied and compared. All these model types can predict the future behavior of dynamic systems over long periods based on training data from relatively short periods. The multi-dimensional inputs of surrogate models are organized in a nonlinear autoregressive exogenous model (NARX) scheme to enable recursive prediction over long periods, where current predictions replace inputs from the previous time window. Three numerical examples, including one mathematical example and two nonlinear engineering analysis models, are used to compare the performance of the four surrogate modeling techniques. The results show that the GP-NARX surrogate model tends to have more stable performance than the other three deep learning (DL)-based methods for the three particular examples studied. The tuning effort of GP-NARX is also much lower than its deep learning-based counterparts.

42 ENGINEERING↗

Fuel Cycle Research & Development, Technical Monthly - February 2012

Topics discussed in this monthly report are: (1) MPACT Campaign management and integration; (2) Accounting and control technologies - microcalorimetry, electrochemical sensor, fast neutron multiplicity analysis, lead slowing down spectrometer; (3) MPACT analysis tools - modeling and simulation for analysis of safeguards performance (electrochemical), material control including process monitoring (pattern recognition, sensors), sensor for measuring density and depth of molten electrolyte, MPACT system integration and technical support.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Active Measurement of Memory Resource Consumption

Hierarchical memory is a cornerstone of modern hardware design because it provides high memory performance and capacity at a low cost. However, the use of multiple levels of memory and complex cache management policies makes it very difficult to optimize the performance of applications running on hierarchical memories. As the number of compute cores per chip continues to rise faster than the total amount of available memory, applications will become increasingly starved for memory storage capacity and bandwidth, making the problem of performance optimization even more critical. We propose a new methodology for measuring and modeling the performance of hierarchical memories in terms on the application’s utilization of the key memory resources: capacity of a given memory level and bandwidth between two levels. This is done by actively interfering with the application’s use of these resources. The application’s sensitivity to reduced resource availability is measured by observing the effect of interference on application performance. The resulting resource-oriented model of performance both greatly simplifies application performance analysis and makes it possible to predict an application’s performance when running with various resource constraints. This is useful to predict performance for future memory-constrained architectures.

97 MATHEMATICS AND COMPUTING↗

Integrated Sensitivity Analysis Workflow

Sensitivity analysis is a crucial element of rigorous engineering analysis, but performing such an analysis on a complex model is difficult and time consuming. The mission of the DART Workbench team at Sandia National Laboratories is to lower the barriers to adoption of advanced analysis tools through software integration. The integrated environment guides the engineer in the use of these integrated tools and greatly reduces the cycle time for engineering analysis.

97 MATHEMATICS AND COMPUTING↗

Test Plan for the Boiling Water Reactor Dry Cask Simulator

The thermal performance of commercial nuclear spent fuel dry storage casks are evaluated through detailed numerical analysis . These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These same vertical, canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above and below-ground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of above-ground and below-ground canistered dry cask systems. The purpose of the investigation described in this report is to produce a data set that can be used to test the validity of the assumptions associated with the calculations presently used to determine steady-state cladding temperatures in modern vertical, canistered dry cask systems. The BWR cask simulator (BCS) has been designed in detail for both the above-ground and below-ground venting configurations. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure (MAWP) rating of 24 bar at 400 deg C. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly is being deployed inside of a representative storage basket and cylindrical pressure vessel that represents the canister. The symmetric single assembly geometry with well-controlled boundary conditions simplifies interpretation of results. Various configurations of outer concentric ducting will be used to mimic conditions for above and below-ground storage configurations of vertical, dry cask systems with canisters. Radial and axial temperature profiles will be measured for a wide range of decay power and helium cask pressures. Of particular interest is the evaluation of the effect of increased helium pressure on allowable heat load and the effect of simulated wind on a simplified below ground vent configuration. While incorporating the best available information, this test plan is subject to changes due to improved understanding from modeling or from as-built deviations to designs. As-built conditions and actual procedures will be documented in the final test report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal-Hydraulic Results for the Boiling Water Reactor Dry Cask Simulator.

The thermal performance of commercial nuclear spent fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both aboveground and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. The purpose of this investigation was to produce validation-quality data that can be used to test the validity of the modeling presently used to determine cladding temperatures in modern vertical dry casks. These cladding temperatures are critical to evaluate cladding integrity throughout the storage cycle. To produce these data sets under well-controlled boundary conditions, the dry cask simulator (DCS) was built to study the thermal-hydraulic response of fuel under a variety of heat loads, internal vessel pressures, and external configurations. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly was deployed inside of a representative storage basket and cylindrical pressure vessel that represents a vertical canister system. The symmetric single assembly geometry with well-controlled boundary conditions simplified interpretation of results. Two different arrangements of ducting were used to mimic conditions for aboveground and belowground storage configurations for vertical, dry cask systems with canisters. Transverse and axial temperature profiles were measured throughout the test assembly. The induced air mass flow rate was measured for both the aboveground and belowground configurations. In addition, the impact of cross-wind conditions on the belowground configuration was quantified. Over 40 unique data sets were collected and analyzed for these efforts. Fourteen data sets for the aboveground configuration were recorded for powers and internal pressures ranging from 0.5 to 5.0 kW and 0.3 to 800 kPa absolute, respectively. Similarly, fourteen data sets were logged for the belowground configuration starting at ambient conditions and concluding with thermal-hydraulic steady state. Over thirteen tests were conducted using a custom-built wind machine. The results documented in this report highlight a small, but representative, subset of the available data from this test series. This addition to the dry cask experimental database signifies a substantial addition of first-of-a-kind, high-fidelity transient and steady-state thermal-hydraulic data sets suitable for CFD model validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Results for the Aboveground Configuration of the Boiling Water Reactor Dry Cask Simulator

The thermal performance of commercial nuclear spent fuel dry storage casks are evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and also by increasing the internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. The purpose of the current investigation was to produce data sets that can be used to test the validity of the assumptions associated with the calculations used to determine steady-state cladding temperatures in modern dry casks that utilize elevated helium pressure in the sealed canister in an aboveground configuration. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly was deployed inside of a representative storage basket and cylindrical pressure vessel that represents a vertical canister system. The symmetric single assembly geometry with well-controlled boundary conditions simplifies interpretation of results. The arrangement of ducting was used to mimic conditions for an aboveground storage configuration in a vertical, dry cask systems with canisters. Transverse and axial temperature profiles were measured for a wide range of decay power and helium cask pressures. Of particular interest was the evaluation of the effect of increased helium pressure on peak cladding temperatures (PCTs) for identical thermal loads. All steady state peak temperatures and induced flow rates increased with increasing assembly power. Peak cladding temperatures decreased with increasing internal helium pressure for a given assembly power, indicating increased internal convection. In addition, the location of the PCT moved from near the top of the assembly to ~1/3 the height of the assembly for the highest (8 bar absolute) to the lowest (0 bar absolute) pressure studied, respectively. This shift in PCT location is consistent with the varying contribution of convective heat transfer proportional with of internal helium pressure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Test Plan for the Horizontal Dry Cask Simulator

The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission(NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the investigation described in this test plan is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator(HDCS) has been designed to generate this benchmark data and add to the existing knowledgebase. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure(MAWP)rating of 2,400 kPa at400 °C. An existing electrically heated but otherwise prototypic boiling water reactor(BWR), Incoloy-clad test assembly will be deployed inside of a representative storage basket and canister. An insulated sheet metal enclosure will be used to mimic the thermal properties of the concrete vault enclosure used in a modern horizontal storage system. Radial and axial temperature profiles along with induced cooling air flow will be measured for a wide range of decay powers and representative(and higher)cask pressures using various backfills of helium, argon, or air. The single assembly geometry with well-controlled boundary conditions simplifies computational requirements while preserving relevant physics. The proposed test apparatus integrates all the underlying thermal-hydraulics important to defining the performance of a modern horizontal storage system. These include combined-mode heat transfer from the electrically-heated assembly to the canister walls and the primarily natural-convective heat transfer from the canister to the cooling air flow passing through the horizontal vault enclosure. The objective of the HDCS is not to reproduce the performance of a commercial dry storage system for any given set of operational parameters. Rather ,the objective is to capture the dominant physics in a well-characterized test apparatus. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance. While incorporating the best available information based on thermal-hydraulic scaling arguments as well as previous vertical testing, this test plan is subject to changes due to improved understanding or from as built deviations to designs. As-built conditions and actual procedures will be documented in the final test report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Manual and User's Guide for MILDOS, Version 4.1

The MILDOS computer code is used to estimate the radiological impacts of airborne emissions from uranium mining and milling facilities. The code allows users to consider both conventional uranium ore operations and operations associated with in situ recovery (ISR) facilities. The code is used by license applicants and U.S. Nuclear Regulatory Commission staff to perform routine radiological impact and compliance evaluations for various uranium recovery operations. As part of a major code update, the following improvements and additions were made to the code: (a) revised ISR models, (b) support for ores containing thorium-232 (Th-232) and its daughter radionuclides in addition to the currently supported uranium-238 (U-238) and its daughter radionuclides, (c) a revised area source model, (d) the capability to perform sensitivity analysis on specific input parameters, (e) the capability to use current meteorological data provided by the National Climatic Data Center, and (f) an interactive results module.

54 ENVIRONMENTAL SCIENCES↗

Update on the Thermal Hydraulic Investigations of a Horizontal Dry Cask Simulator

The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a canister in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full-sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the present investigation is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator (HDCS) has been designed to generate this benchmark data and add to the existing knowledge base. The objective of the HDCS investigation is to capture the dominant physics of a commercial dry storage system in a well-characterized test apparatus for any given set of operational parameters. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhancing Risk Analysis of Accidental Release Using CFD Modeling and Machine Learning

This project report presents the results from the AU31 project that is entitled “Enhancing Risk Analysis of Accidental Release Using CFD Modeling and Machine Learning” performed between FY2021 and FY2022. The technical objective of this project is to enhance risk analysis of accidental release of radioactive materials and provide novel risk forecasting and capabilities for assessing unplanned hazardous chemical releases for the U.S. Department of Energy (DOE). The approach includes a cross-platform finite element analysis of airborne chemical release, machine learning (ML) for simulation and forecasting, and a big data approach to data management, transformation and analysis capable of handling petabyte-scale unstructured and structured data. The outcome of these findings were assembled and accessible as a final output via an intuitive web hosted geospatial-based user interface for demonstration and general dissemination. These new results also provide a mechanism of combining this knowledge in a risk analysis framework tool. The geospatial analysis and output can utilize 5 years of qualified meteorological data to illustrate projected plume footprints that are generated from computational aspects of this study. Specifically, we show the development of a geospatial risk analysis capabilities to respond to and plan for accidental release of radioactive materials and to provide a risk forecasting tool for assessing hazardous chemical releases for the DOE. The focus of this effort is germane to common practices in risk analysis; and it is highly relevant to the timely and transparent release of information related to materials at risk including hazardous materials and chemical vapors and rapid assessment of the potential impacts on the workforce at active sites across the DOE complex.

42 ENGINEERING↗

Renewable Thermal Energy Systems: Characterization of the Most Important Thermal Energy Applications in Buildings and Industry (Report 1)

This report is the first in a three-report series that evaluates the provision of renewable heat for industry and buildings via current and prospective renewable thermal energy system (RTES) technologies. The RTES project has undertaken initial research focused on technologies that could be suited for industrial process heat applications at different temperature levels, and, where possible, gathered performance and cost data for these technologies. This project does not directly evaluate RTES for distributed residential or commercial applications, nor does it yet include documented cases or modeling of RTES using geothermal, biomass, waste heat, renewable fuels like renewable natural gas, or hydrogen production. The three technical reports are summarized as follows: Renewable Thermal Energy Systems: Characterization of the Most Important Thermal Energy Applications in Buildings and Industry (Report 1), this report: summary of thermal demands of U.S. industry and buildings, and relevant hybrid RTES configurations; Renewable Thermal Energy Systems: Systemic Challenges and Transformational Policies (Report 2): discussion of socio-technical characteristics of RTES, innovation challenges, and supporting policies. Available at: https://www.nrel.gov/docs/fy23osti/83020.pdf; Renewable Thermal Energy Systems: Modeling Developments and Future Directions (Report 3): Energy yield and performance modeling of RTES, techno-economic analysis via case studies, and proposed development of a user decision support tool. Available at: https://www.nrel.gov/docs/fy23osti/83021.pdf.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

Condenser Enclosure Vibration Isolation Mount Selection

A mini split cooling system will be used to maintain temperature requirements in a mobile secure transport system. While the split cooling system was designed to be used in static residential or commercial applications, it was selected for this transportation application due to a unique set of security requirements. However, the system’s ability maintain reliability and survive prolonged long-term shock and vibration is a significant concern. The mitigation strategy is to select vibration isolation mounts and perform lifetime shock and vibration testing to demonstrate survivability. The goal of this study is to generate a finite element model of the system and perform modal analysis to inform selection of vibration mounts to minimize the amount of vibrational energy transferred to the split cooling system. The scope of this report is limited to study of the condensing unit only, and geometric variation of the assembly will not be allowed.

42 ENGINEERING↗