TUNGSTEN ISOTOPIC COMPOSITIONS IN STARDUST SiC GRAINS FROM THE MURCHISON METEORITE: CONSTRAINTS ON THE s-PROCESS IN THE Hf-Ta-W-Re-Os REGION

We report the first tungsten isotopic measurements in stardust silicon carbide (SiC) grains recovered from the Murchison carbonaceous chondrite. The isotopes {sup 182,183,184,186}W and {sup 179,180}Hf were measured on both an aggregate (KJB fraction) and single stardust SiC grains (LS+LU fraction) believed to have condensed in the outflows of low-mass carbon-rich asymptotic giant branch (AGB) stars with close-to-solar metallicity. The SiC aggregate shows small deviations from terrestrial (= solar) composition in the {sup 182}W/{sup 184}W and {sup 183}W/{sup 184}W ratios, with deficits in {sup 182}W and {sup 183}W with respect to {sup 184}W. The {sup 186}W/{sup 184}W ratio, however, shows no apparent deviation from the solar value. Tungsten isotopic measurements in single mainstream stardust SiC grains revealed lower than solar {sup 182}W/{sup 184}W, {sup 183}W/{sup 184}W, and {sup 186}W/{sup 184}W ratios. We have compared the SiC data with theoretical predictions of the evolution of W isotopic ratios in the envelopes of AGB stars. These ratios are affected by the slow neutron-capture process and match the SiC data regarding their {sup 182}W/{sup 184}W, {sup 183}W/{sup 184}W, and {sup 179}Hf/{sup 180}Hf isotopic compositions, although a small adjustment in the s-process production of {sup 183}W is needed in order to have a better agreement between the SiC data and model predictions. The models cannot explain the {sup 186}W/{sup 184}W ratios observed in the SiC grains, even when the current {sup 185}W neutron-capture cross section is increased by a factor of two. Further study is required to better assess how model uncertainties (e.g., the formation of the {sup 13}C neutron source, the mass-loss law, the modeling of the third dredge-up, and the efficiency of the {sup 22}Ne neutron source) may affect current s-process predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reversible CO 2 Hydrogenation, Neutron Crystallography, and Hydride Reactivity of a Triiridium Heptahydride Complex

Abstract The authors report the structure, reactivity, and catalytic utility of a triiridium complex, [Ir 3 H 6 ( μ 3 ‐H)(PN) 3 ] 2+ ( 2‐H , PN = (2‐pyridyl)CH 2 PBu t 2 ). Despite its unusual stability to unsaturated organics, electrophiles, and even CF 3 SO 3 D, they find that complex 2‐H catalyzes hydrogenation of CO 2 to formate (TON Ir = 9600) and reverse formic acid dehydrogenation (TON Ir = 54 400). The hydrogenation operates via a reactive intermediate [Ir 3 H 4 ( μ ‐H) 4 (PN) 3 ] + ( 5 ). Neutron crystallography and DFT‐supported neutron vibrational spectroscopy of 2‐H reveal Ir─H bond lengths and elucidate the vibration modes within the Ir 3 H 7 core. Stoichiometric oxidation of 2‐H produces four classes of iridium complexes of varied nuclearity and hydride structure: tetra‐ and pentanuclear clusters [Ir 3 H 6 ( μ 3 ‐AuPPh 3 )(PN) 3 ] 2+ ( 2‐Au ) and [Ag{Ir 2 H 4 ( μ ‐OAc)(PN) 2 } 2 ] 3+ ( 6 ) are generated using AuPPh 3 + and AgOAc, respectively. Further oxidation to class [Ir 2 H 3 ( μ ‐X) 2 (PN) 2 ] + is possible with AgOAc, Hg(OAc) 2 , or I 2 . Finally, a TEMPO/HCl system completely oxidizes the hydrides and gives [Ir 2 Cl 4 ( μ ‐Cl) 2 (PN) 2 ] ( 11 ).

Cherepakhin, Valeriy [Loker Hydrocarbon Research I↗

A novel compact three-dimensional laser-sintered collimator for neutron scattering

Improvements in the available flux at neutron sources are making it increasingly feasible to obtain refineable neutron diffraction data from samples smaller than 1 mm{sup 3}. The signal is typically too weak to introduce any further sample environment in the 30–50 mm diameter surrounding the sample (such as the walls of a pressure cell) due to the high ratio of background to sample signal, such that even longer count times fail to reveal reflections from the sample. Many neutron instruments incorporate collimators to reduce parasitic scattering from the instrument and from any surrounding material and larger pieces of sample environment, such as cryostats. However, conventional collimation is limited in the volume it can focus on due to difficulties in producing tightly spaced neutron-absorbing foils close to the sample and in integrating this into neutron instruments. Here we present the design of a novel compact 3D rapid-prototyped (or “printed”) collimator which reduces these limitations and is shown to improve the ratio of signal to background, opening up the feasibility of using additional sample environment for neutron diffraction from small sample volumes. The compactness and ease of customisation of the design allows this concept to be integrated with existing sample environment and with designs that can be tailored to individual detector geometries without the need to alter the setup of the instrument. Results from online testing of a prototype collimator are presented. The proof of concept shows that there are many additional collimator designs which may be manufactured relatively inexpensively, with a broad range of customisation, and geometries otherwise impossible to manufacture by conventional techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Body composition to climate change studies - the many facets of neutron induced prompt gamma-ray analysis

In-vivo body composition analysis of humans and animals and in-situ analysis of soil using fast neutron inelastic scattering and thermal neutron capture induced prompt-gamma rays have been described. By measuring carbon (C), nitrogen (N) and oxygen (O), protein, fat and water are determined. C determination in soil has become important for understanding below ground carbon sequestration process in the light of climate change studies. Various neutron sources ranging from radio isotopic to compact 14 MeV neutron generators employing the associated particle neutron time-of-flight technique or micro-second pulsing were implemented. Gamma spectroscopy using recently developed digital multi-channel analyzers has also been described.

54 ENVIRONMENTAL SCIENCES↗

Hydration-Dependent Dynamical Transition in Protein: Protein Interactions at 240 K

Interprotein motions in low and fully hydrated carboxymyoglobin crystals are investigated using molecular dynamics simulation. Below {approx} 240 K, the calculated dynamic structure factor exhibits a peak arising from interprotein vibration. Above {approx} 240 K, the intermolecular fluctuations of the fully hydrated crystal increase drastically, whereas the low-hydration model exhibits no transition. Autocorrelation function analysis shows the transition to be dominated by the activation of diffusive intermolecular motion. The potential of mean force for the interaction remains quasiharmonic. The results indicate useful experimental avenues on protein:protein interactions to be explored using next-generation neutron sources.

59 BASIC BIOLOGICAL SCIENCES↗

Multiple source associated particle imaging for simultaneous capture of multiple projections

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing neutron radiography. For example, in one exemplary method, an object is interrogated with a plurality of neutrons. The plurality of neutrons includes a first portion of neutrons generated from a first neutron source and a second portion of neutrons generated from a second neutron source. Further, at least some of the first portion and the second portion are generated during a same time period. In the exemplary method, one or more neutrons from the first portion and one or more neutrons from the second portion are detected, and an image of the object is generated based at least in part on the detected neutrons from the first portion and the detected neutrons from the second portion.

47 OTHER INSTRUMENTATION↗

H- Ion Sources for High Intensity Proton Drivers

Spallation neutron source user facilities require reliable, intense beams of protons. The technique of H- charge exchange injection into a storage ring or synchrotron can provide the needed beam currents, but may be limited by the ion sources that have currents and reliability that do not meet future requirements and emittances that are too large for efficient acceleration. In this project we are developing an H- source which will synthesize the most important developments in the field of negative ion sources to provide high current, small emittance, good lifetime, high reliability, and power efficiency. We describe planned modifications to the present external antenna source at SNS that involve: 1) replacing the present 2 MHz plasma-forming solenoid antenna with a 60 MHz saddle-type antenna and 2) replacing the permanent multicusp magnet with a weaker electromagnet, in order to increase the plasma density near the outlet aperture. The SNS test stand will then be used to verify simulations of this approach that indicate significant improvements in H- output current and efficiency, where lower RF power will allow higher duty factor, longer source lifetime, and/or better reliability.

43 PARTICLE ACCELERATORS↗

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Artificial Neural Networks in Spectrometry and Neutron Dosimetry

The ANN technology has been applied to unfold the neutron spectra of three neutron sources and to estimate their dosimetric features. To compare these results, neutron spectra were also unfolded with the BUNKIUT code. Both unfolding procedures were carried out using the count rates of a Bonner sphere spectrometer. The spectra unfolded with ANN result similar to those unfolded with the BUNKIUT code. The H*(10) values obtained with ANN agrees well with H*(10) values calculated with the BUNKIUT code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESIGN AND ANALYSIS OF AN FPGA-BASED ACTIVE FEEDBACK DAMPING SYSTEM

The Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory is a high-intensity proton-based accelerator that produces neutron beams for neutronscattering research. As the most powerful pulsed neutron source in the world, the SNS accelerator has experienced an unprecedented beam instability that has a wide bandwidth (0 to 300MHz) and fast growth time (10 to100 s). In this paper, we propose and analyze several FPGA-based designs for an active feedback damping system. This signal processing system is the first FPGA-based design for active feedback damping of wideband instabilities in high intensity accelerators. It can effectively mitigate instabilities in highintensity protons beams, reduce radiation, and boost the accelerator s luminosity performance. Unlike existing systems, which are designed using analog components, our FPGA-based active feedback damping system offers programmability while maintaining high performance. To meet the system throughput and latency requirements, our proposed designs are guided by detailed analysis of resource and performance tradeoffs. These designs are mapped onto a reconfigurable platform that includes Xilinx Virtex-II Pro FPGAs and high-speed analog-to-digital and digital-toanalog converters. Our results show that our FPGA-based active feedback damping system can provide increased flexibility and improved signal processing performance that are not feasible with existing analog systems.

43 PARTICLE ACCELERATORS↗

Soft Matter Sample Environments for Time-Resolved Small Angle Neutron Scattering Experiments: A Review

With the promise of new, more powerful neutron sources in the future, the possibilities for time-resolved neutron scattering experiments will improve and are bound to gain in interest. While there is already a large body of work on the accurate control of temperature, pressure, and magnetic fields for static experiments, this field is less well developed for time-resolved experiments on soft condensed matter and biomaterials. We present here an overview of different sample environments and technique combinations that have been developed so far and which might inspire further developments so that one can take full advantage of both the existing facilities as well as the possibilities that future high intensity neutron sources will offer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of the filter method for neutron pulse-height distributions measured with organic scintillators

Identification of neutron sources is of interest in several fields, such as homeland security or basic nu-clear physics. Organic scintillators offer the possibility to unfold fast-neutron energy spectra. Since organic scintillators are sensitive to neutrons and gamma-rays, a method to discriminate these two types of particles is required. This paper is focused on investigation of the discrimination properties of the filter method by using a new procedure. We compare the results of an experimental filter method to a digital pulse-shape discrimination (PSD) method based on charge integration. In addition, these methods are compared to the simulation results obtained with the MCNPX-PoliMi code. The experimental and nu-merical investigations were performed with a 252Cf spontaneous-fission neutron source. The integration of the number of counts gave the relative differences between the experimental filter and digital PSD neutron pulse-height distributions (PHDs) and simulated PHDs less than approximately 5% in the range between 60 keVee and 1.715 MeVee of light output. Above 1.715 MeVee, the PSD method has advantages over the filter method, due to the filter method having significantly worse counting statistics. The results show that the filter method has potential for robust neutron measurements when the PSD method cannot be applied, such as for ‘old’ organic plastic scintillators without PSD capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the new SNS injector and external antenna ion source

The U.S. Spallation Neutron Source (SNS) now operates with 1.2 MW of beam power on target with the near-term goal of delivering 1.4 MW and a longer-term goal of delivering >2 MW required by the planned Proton Power Upgrade (PPU) and Second Target Station (STS) projects. In early 2018 we plan to replace the entire 2.5 MeV injector configuration which includes the ion source, the Low Energy Beam Transport (LEBT) and the Radio Frequency Quadrupole accelerator (RFQ) with one which is currently being tested on a research accelerator called the Beam Test Facility (BTF) located at the SNS facility. This report first provides a description of the new injector: the ion source and the cage enclosure, the new LEBT support structure and the new RFQ. Since fall of 2016, this system has been tested extensively with regard to output beam current, beam persistence, emittance and energy. The results of these experiments employing both internal and external antenna ion sources will be summarized here showing the system to be capable of supporting SNS 1.4 MW operations with a significant margin as well as potentially meeting facility upgrade requirements. This represents a significant performance upgrade over the current SNS front end system with the compromised RFQ and will replace that system in early 2018.

Welton, Robert F.↗

YALINA-booster subcritical assembly pulsed-neutron experiments : data processing and spatial corrections.

The YALINA-Booster experiments and analyses are part of the collaboration between Argonne National Laboratory of USA and the Joint Institute for Power & Nuclear Research - SOSNY of Belarus for studying the physics of accelerator driven systems for nuclear energy applications using low enriched uranium. The YALINA-Booster subcritical assembly is utilized for studying the kinetics of accelerator driven systems with its highly intensive D-T or D-D pulsed neutron source. In particular, the pulsed neutron methods are used to determine the reactivity of the subcritical system. This report examines the pulsed-neutron experiments performed in the YALINA-Booster facility with different configurations for the subcritical assembly. The 1141 configuration with 90% U-235 fuel and the 1185 configuration with 36% or 21% U-235 fuel are examined. The Sjoestrand area-ratio method is utilized to determine the reactivities of the different configurations. The linear regression method is applied to obtain the prompt neutron decay constants from the pulsed-neutron experimental data. The reactivity values obtained from the experimental data are shown to be dependent on the detector locations inside the subcritical assembly and the types of detector used for the measurements. In this report, Bell's spatial correction factors are calculated based on a Monte Carlo model to remove the detector dependences. The large differences between the reactivity values given by the detectors in the fast neutron zone of the YALINA-Booster are reduced after applying the spatial corrections. In addition, the estimated reactivity values after the spatial corrections are much less spatially dependent.

43 PARTICLE ACCELERATORS↗

SNS second target station moderator performance update

In its first years of operations of its first target station, the Spallation Neutron Source (SNS) is working towards a facility upgrade by a megawatt-class second target station operated at 20 Hz repetition rate, which is intended to complement the existing ORNL neutron sources, the first SNS target station and the HFIR reactor, with high-intensity cold neutron beams.The first round of optimization calculations converged on larger-volume cylindrical para-hydrogen moderators placed in wing configuration on top and bottom of a flat mercury target, pre-moderated by layers of ambient water and surrounded by beryllium reflector. The metric of these optimization calculations was time-averaged and energy-integrated neutron brightness below 5 meV with the requirement to be able to serve 20 ports with neutrons. A summary of these calculations will be given including lessons learned from the variety of simulated configurations and detailed neutron performance characteristics like spectral intensities, emission time distributions, local variations of moderator brightness at the viewed areas, and sensitivity of the optimization metric to optimized parameters for the most promising configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ion Source Development at the SNS

The Spallation Neutron Source (SNS) now routinely operates near 1 MW of beam power on target with a highly-persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. The {approx}1 ms-long, 60 Hz, {approx}50 mA H{sup -} beam pulses are extracted from a Cs-enhanced, multi-cusp, RF-driven, internal-antenna ion source. An electrostatic LEBT (Low Energy Beam Transport) focuses the 65 kV beam into the RFQ accelerator. The ion source and LEBT have normally a combined availability of {approx}99%. Although much progress has been made over the last years to achieve this level of availability further improvements are desirable. Failures of the internal antenna and occasionally impaired electron dump insulators require several source replacements per year. An attempt to overcome the antenna issues with an AlN external antenna source early in 2009 had to be terminated due to availability issues. This report provides a comprehensive review of the design, experimental history, status, and description of recently updated components and future plans for this ion source. The mechanical design for improved electron dump vacuum feedthroughs is also presented, which is compatible with the baseline and both external antenna ion sources.

07 ISOTOPE AND RADIATION SOURCES↗

Next Generation H{sup -} Ion Sources for the SNS

The U.S. Spallation Neutron Source (SNS) is the leading accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure meeting operational requirements as well as providing for future facility beam power upgrades, a multifaceted H- ion source development program is ongoing. This work discusses several aspects of this program, specifically the design and first beam measurements of an RF-driven, external antenna H- ion source based on an A1N ceramic plasma chamber, elemental and chromate Cs-systems, and plasma ignition gun. Unanalyzed beam currents of up to {approx}100 mA(60 Hz, 1 ms) have been observed and sustained currents >60 mA(60 Hz, 1 ms) have been demonstrated on the test stand. Accelerated beam currents of {approx}40 mA have also been demonstrated into the SNS front end. Data are also presented describing the first H- beam extraction experiments from a helicon plasma generator based on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) engine design.

43 PARTICLE ACCELERATORS↗

Measurement of ion beam profiles in a superconducting linac with a laser wire

A laser wire ion beam profile monitor system has been developed at the Spallation Neutron Source accelerator complex. The laser wire system uses a single laser source to measure the horizontal and vertical profiles of a pulsed hydrogen ion (H{sup -}) beam along a 230 m long superconducting linac, which accelerates H{sup -} from 200 MeV to 1 GeV. In this paper, we describe the laser optics requirement for the system, the performance of the profile measurement, and the effects of laser parameters on the measurement reliability. The result provides a practical guideline for the development of a large-scale, operational, laser-based diagnostics in accelerator facilities.

43 PARTICLE ACCELERATORS↗