Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Human-building interaction at work: Findings from an interdisciplinary cross-country survey in Italy

This study presents results from an interdisciplinary survey assessing contextual and behavioral factors driving occupants’ interaction with building and systems in offices located across three different Mediterranean climates in Turin (Northern), Perugia (Central), and Rende (Southern) Italy. The survey instrument is grounded in an interdisciplinary framework that bridges the gap between building physics and social science environments on the energy- and comfort-related human-building interaction in the workspace. Outcomes of the survey questionnaire provide insights into four key learning objectives: (1) individual occupant's motivational drivers regarding interaction with shared building environmental controls (such as adjustable thermostats, operable windows, blinds and shades, and artificial lighting), (2) group dynamics such as perceived social norms, attitudes, and intention to share controls, (3) occupant perception of the ease of use and knowledge of how to operate control systems, and (4) occupant-perceived comfort, satisfaction, and productivity. The study attempts to identify climatic, cultural, and socio-demographic influencing factors, as well as to establish the validity of the survey instrument and robustness of outcomes for future studies. Also, the paper aims at illustrating why and how social science insights can bring innovative knowledge into the adoption of building technologies in shared contexts, thus enhancing perceived environmental satisfaction and effectiveness of personal indoor climate control in office settings and impacting office workers’ productivity and reduced operational energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Linking human-building interactions in shared offices with personality traits

Occupant behavior influences office building energy performance. The level of human-building interactions (HBIs) in shared offices strongly influences building energy use and occupant well-being. This study explored the link between occupant personality types and their behaviors of sharing energy and environment control systems and interactions with their colleagues. Inspired by the Five-Factor Model (FFM), we classified HBI behaviors into four dimensions: willingness to share control, knowledge of control, group decision behavior, and adaptive strategies. These four variables can be mapped to the four personality traits proposed by the FFM: agreeableness, openness, extraversion, and conscientiousness. Our cluster analysis identified six behavioral patterns: average (17.7%), reserved (15.3%), environmentally friendly (16.6%), role model (24.2%), self-centered (17.2%), and mechanist (9.0%). We further applied association rules, a widely utilized machine learning technique, to discover how demographics, building-related contextual factors, and perception-attitudinal factors influence HBI behaviors. Country, control feature accessibility, and group dynamics were found to be the three most influential factors that determine occupants’ HBI behaviors. Finally, the study provides insights about building design and operation, as well as policy to promote socially and environmentally desirable HBI behaviors in a shared office environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamic modeling of the Pd–Zn system with uncertainty quantification and its implication to tailor catalysts

Pd–Zn intermetallic catalysts show encouraging combinations of activity and selectivity on well-defined active site ensembles. Thermodynamic description of the Pd–Zn system, delineating phase boundaries and enumerating site occupancies within intermediate alloy phases, is essential to determining the ensembles of Pd–Zn atoms as a function of composition and temperature. Combining the present extensive first-principles calculations based on density functional theory (DFT) and available experimental data, the Pd–Zn system was remodeled using the CALculation of PHAse Diagrams (CALPHAD) approach. High throughput modeling tools with uncertainty quantification, i.e., ESPEI and PyCalphad, were incorporated in the phase analysis. Here, the site occupancies across the γ phase composition region were given special attention. A four-sublattice model was used for the γ phase owing to its four Wyckoff positions, i.e., the outer tetrahedral (OT) site 8c, the inner tetrahedral (IT) site 8c, the octahedral (OH) site 12e, and the cuboctahedral (CO) site 24g. The site fractions of Pd and Zn calculated from the present thermodynamic model show the occupancy preference of Pd in the OT and OH sublattices in agreement with experimental observations. The force constants obtained from DFT-based phonon calculations further supports the tendency of Pd occupying the OH sublattice compared with the IT and CO sublattice. The catalytic ensembles changing from Pd monomers (Pd 1 ) to trimers (Pd 3 ) on the surface of γ phase are attributed to the increase of Pd occupancy in the OH sublattice.

36 MATERIALS SCIENCE↗

An observational study of the potential for human exposures to pet-borne diazinon residues following lawn applications

This study examined the potential for pet dogs to be an important pathway for transporting diazinon residues into homes and onto its occupants following residential lawn applications. The primary objectives were to investigate the potential exposures of occupants and their pet dogs to diazinon after an application to turf at their residences and to determine if personal contacts between occupants and their pet dogs resulted in measurable exposures. It was conducted from April to August 2001 before the Agency phased out all residential uses of diazinon in December 2004. Six families and their pet dogs were recruited into the study. Monitoring was conducted at pre-, 1, 2, 4, and 8 days post-application of a commercial, granular formulation of diazinon to the lawn by the homeowner. Environmental samples collected included soil, indoor air, carpet dust, and transferable residues from lawns and floors. Samples collected from the pet dogs consisted of paw wipes, fur clippings, and transferable residues from the fur by a technician or child wearing a cotton glove(s). First morning void (FMV) urine samples were collected from each child and his/her parent on each sampling day. Diazinon was analyzed in all samples, except urine, by GC-MS. The metabolite 2-isopropyl-4-methyl-6-hydroxypyrimidine (IMPy) was analyzed in the urine samples by HPLC-MS/MS. Mean airborne residues of diazinon on day 1 post-application were at least six times higher in both the living rooms (235{+-}267 ng/m{sup 3}) and children's bedrooms (179{+-}246 ng/m{sup 3}) than at pre-application. Mean loadings of diazinon in carpet dust samples were at least 20 times greater on days 2, 4, and 8 post-application than mean loadings (0.03{+-}0.04 ng/cm{sup 2}) at pre-application. The pet dogs had over 900 times higher mean loadings of diazinon residues on their paws on day 1 post-application (88.1{+-}100.1 ng/cm{sup 2}) compared to mean loadings (<0.09 ng/cm{sup 2}) at pre-application. The mean diazinon loadings on the fur clippings were at least 14 times higher on days 1, 2, 4, and 8 post-application than mean loadings (0.8{+-}0.4 ng/cm{sup 2}) at pre-application. For transferable residues from dog fur, the mean loadings of diazinon on the technician's cotton glove samples were the lowest before application (0.04{+-}0.08 ng/cm{sup 2}) and the highest on day 1 post-application (10.4{+-}23.9 ng/cm{sup 2}) of diazinon to turf. Urinary IMPy concentrations for the participants ranged from <0.3 to 5.5 ng/mL before application and <0.3-12.5 ng/mL after application of diazinon. The mean urinary IMPy concentrations for children or adults were not statistically different (p>0.05) at pre-application compared to post-application of diazinon to turf. The results showed that the participants and their pet dogs were likely exposed to low levels of diazinon residues from several sources (i.e., air, dust, and soil), through several pathways and routes, after lawn applications at these residences. Lastly, the pet dog appears to be an important pathway for the transfer and translocation of diazinon residues inside the homes and likely exposed occupants through personal contacts (i.e., petting)

60 APPLIED LIFE SCIENCES↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Aggregate residential demand flexibility behavior: A novel assessment framework

Residential demand flexibility (DF) could save the U.S. electric grid up to 10 GW of peak demand while supporting increased amounts of renewable generation. However, less than 40% of the estimated DF peak reduction capacity is currently realized, and less than 8% of American households are enrolled. These low participation rates are combined with high rates of "overriding" a DF event and eventual opt-outs among enrolled customers. There is still not a comprehensive understanding of the drivers of DF participation and occupant interaction with DF program signals. We, therefore, present a novel survey processing framework to assess occupant DF-relevant behavior from the American Time Use Survey (ATUS). Using the framework, we summarize both the extensive and intensive behavior of more than 200,000 ATUS respondents (2003-2018 data) and provide insights on the DF-relevant behavior of residential occupants, which is generally overlooked in the literature. Here we use the framework to identify the activity priorities of residential occupants in the United States during different DF-relevant periods (critical peak, peak, and off-peak). These preferred activities capture overlooked routine behaviors that could be barriers to DF participation, if ignored, and might explain the high levels of overrides often exhibited by participants of demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Night-time naturally ventilated offices: Statistical simulations of window-use patterns from field monitoring

This paper investigates occupant behaviour of window-use in night-time naturally ventilated offices on the basis of a pilot field study, conducted during the summers of 2006 and 2007 in Cambridge, UK, and then demonstrates the effects of employing night-time ventilation on indoor thermal conditions using predictive models of occupant window-use. A longitudinal field study shows that occupants make good use of night-time natural ventilation strategies when provided with openings that allow secure ventilation, and that there is a noticeable time of day effect in window-use patterns (i.e. increased probability of action on arrival and departure). We develop logistic models of window-use for night-time naturally ventilated offices, which are subsequently applied to a behaviour algorithm, including Markov chains and Monte Carlo methods. The simulations using the behaviour algorithm demonstrate a good agreement with the observational data of window-use, and reveal how building design and occupant behaviour collectively affect the thermal performance of offices. They illustrate that the provision of secure ventilation leads to more frequent use of the window, and thus contributes significantly to the achievement of a comfortable indoor environment during the daytime occupied period. For example, the maximum temperature for a night-time ventilated office is found to be 3 C below the predicted value for a daytime-only ventilated office. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Is a classical language adequate in assessing the detectability of the redshifted 21 cm signal from the early Universe?

The classical radiometer equation is commonly used to calculate the detectability of the 21 cm emission by diffuse cosmic hydrogen at high redshifts. However, the classical description is only valid in the regime where the occupation number of the photons in phase space is much larger than unity and they collectively behave as a classical electromagnetic field. At redshifts z{approx}<20, the spin temperature of the intergalactic gas is dictated by the radiation from galaxies and the brightness temperature of the emitting gas is in the range of mK, independently from the existence of the cosmic microwave background. In regions where the observed brightness temperature of the 21 cm signal is smaller than the observed photon energy, h{nu} = 68(1+z){sup -1} mK, the occupation number of the signal photons is smaller than unity. Nevertheless, the radiometer equation can still be used in this regime because the weak signal is accompanied by a flood of foreground photons with a high occupation number (involving the synchrotron galactic emission and the cosmic microwave background). As the signal photons are not individually distinguishable, the combined signal+foreground population of photons has a high occupation number, thus justifying the use of the radiometer equation.

79 ASTRONOMY AND ASTROPHYSICS↗

Pollutant Exposures from Natural Gas Cooking Burners: A Simulation-Based Assessment for Southern California

Background: Residential natural gas cooking burners (NGCBs) can emit substantial quantities of pollutants, and they are typically used without venting range hoods. Objective: We quantified pollutant concentrations and occupant exposures resulting from NGCB use in California homes. Methods: A mass-balance model was applied to estimate time-dependent pollutant concentrations throughout homes in Southern California and the exposure concentrations experienced by individual occupants. We estimated nitrogen dioxide (NO2), carbon monoxide (CO), and formaldehyde (HCHO) concentrations for 1 week each in summer and winter for a representative sample of Southern California homes. The model simulated pollutant emissions from NGCBs as well as NO2 and CO entry from outdoors, dilution throughout the home, and removal by ventilation and deposition. Residence characteristics and outdoor concentrations of NO2 and CO were obtained from available databases. We inferred ventilation rates, occupancy patterns, and burner use from household characteristics. We also explored proximity to the burner(s) and the benefits of using venting range hoods. Replicate model executions using independently generated sets of stochastic variable values yielded estimated pollutant concentration distributions with geometric means varying by < 10%. Results: The simulation model estimated that—in homes using NGCBs without coincident use of venting range hoods—62%, 9%, and 53% of occupants are routinely exposed to NO2, CO, and HCHO levels that exceed acute health-based standards and guidelines. NGCB use increased the sample median of the highest simulated 1-hr indoor concentrations by 100, 3,000, and 20 ppb for NO2, CO, and HCHO, respectively. Conclusions: Reducing pollutant exposures from NGCBs should be a public health priority. Simulation results suggest that regular use of even moderately effective venting range hoods would dramatically reduce the percentage of homes in which concentrations exceed health-based standards.

54 ENVIRONMENTAL SCIENCES↗

Proposed Risk-Based Approach for Nitrosamine Chemicals of Potential Concern

This report documents the re-evaluation of Hanford Tank Farm (HTF) occupational exposure limits (OEL) for five N-nitrosamines identified as Chemicals of Potential Concern (COPC), and two other N-nitrosamines being considered as COPCs. N-nitrosamines are genotoxic, and exposure has been historically regulated based on cancer as the endpoint of concern. Currently, HTF OELs are based on German Maximum Arbeitsplatz Konzentration values that are no longer used. The National Institute of Occupational Safety and Health (NIOSH) recently released new policy applying a risk-based approach to develop OELs for occupational carcinogens and plans to release guidance on specific chemicals in the future. Consistent with this new NIOSH policy, Pacific Northwest National Laboratory proposes a risk-based approach to establish risk-specific doses for occupational exposures to N-nitrosamine COPCs. This approach establishes a range of N-nitrosamine inhalation exposures associated with risk levels that can be used as a tool for protecting HTF workers. Updated guidance from NIOSH or other authoritative bodies on N-nitrosamine OELs should trigger a re-evaluation of this proposed approach.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Hardware-in-the-loop Laboratory Performance Verification of Flexible Building Equipment in a Typical Commercial Building

This project aims to develop high-resolution equipment performance and occupant data that quantifies demand flexibility in typical commercial buildings. The dataset documented in this report includes comprehensive time-series measurements from hardware-in-the-loop (HIL) experiments conducted across multiple testbeds designed to simulate realistic operational environments for HVAC systems. Specifically, it captures minute-by-minute high-resolution data on the performance of various typical HVAC systems, including a variable-air-volume (VAV) air handling unit (AHU) system with chillers and an ice tank in the Intelligent Building Agents Laboratory (IBAL) at the National Institute of Standards and Technology (NIST), a two-stage air-source heat pump (ASHP) at the NIST, and a water-source heat pump (WSHP) at Texas A&M University (TAMU). The data were generated under a range of controlled conditions reflecting different grid scenarios and climatic influences, as well as various control strategies, building types, occupancy patterns, and occupant behaviors. This dataset provides DE-EE0009153 Final Report 5 detailed insights into the demand flexibility of these systems, including their response to grid signals, occupant behaviors, energy consumption patterns, and operational efficiency under different conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nevada Test Site Radiation Protection Program - Revision 1

Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection,' establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration off-site projects. This NTS RPP promulgates the radiation protection standards, limits, and program requirements for occupational exposure to ionizing radiation resulting from NNSA/NSO activities at the NTS and other operational areas as stated in 10 CFR 835.1(a). NNSA/NSO activities (including design, construction, operation, and decommissioning) within the scope of this RPP may result in occupational exposures to radiation or radioactive material. Therefore, a system of control is implemented through specific references to the site-specific NV/YMP RCM. This system of control is intended to ensure that the following criteria are met: (1) occupational exposures are maintained as low as reasonably achievable (ALARA), (2) DOE's limiting values are not exceeded, (3) employees are aware of and are prepared to cope with emergency conditions, and (4) employees are not inadvertently exposed to radiation or radioactive material.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recommended Changes to Specifications for Demand Controlled Ventilation in California's Title 24 Building Energy Efficiency Standards

In demand-controlled ventilation (DCV), rates of outdoor air ventilation are automatically modulated as occupant density varies. The objective is to keep ventilation rates at or above design specifications and code requirements and also to save energy by avoiding excessive ventilation rates. DCV is most often used in spaces with highly variable and sometime dense occupancy. In almost all cases, carbon dioxide (CO{sub 2}) sensors installed in buildings provide the signal to the ventilation rate control system. People produce and exhale CO{sub 2} as a consequence of their normal metabolic processes; thus, the concentrations of CO{sub 2} inside occupied buildings are higher than the concentrations of CO{sub 2} in the outdoor air. The magnitude of the indoor-outdoor CO{sub 2} concentration difference decreases as the building's ventilation rate per person increases. The difference between the indoor and outdoor CO{sub 2} concentration is also a proxy for the indoor concentrations of other occupant-generated bioeffluents, such as body odors. Reviews of the research literature on DCV indicate a significant potential for energy savings, particularly in buildings or spaces with a high and variable occupancy. Based on modeling, cooling energy savings from applications of DCV are as high as 20%. With support from the California Energy Commission and the U.S. Department of Energy, the Lawrence Berkeley National Laboratory has performed research on the performance of CO{sub 2} sensing technologies and optical people counters for DCV. In addition, modeling was performed to evaluate the potential energy savings and cost effectiveness of using DCV in general office spaces within the range of California climates. The above-described research has implications for the specifications pertaining to DCV in section 121 of the California Title 24 Standard. Consequently, this document suggests possible changes in these specifications based on the research findings. The suggested changes in specifications were developed in consultation with staff from the Iowa Energy Center who evaluated the accuracy of new CO{sub 2} sensors in laboratory-based research. In addition, staff of the California Energy Commission, and their consultants in the area of DCV, provided input for the suggested changes in specifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AlphaBuilding - Synthetic Buildings Operation Dataset

This is a synthetic building operation dataset which includes HVAC, lighting, miscellaneous electric loads (MELs) system operating conditions, occupant counts, environmental parameters, end-use and whole-building energy consumptions at 10-minute intervals. The data is created with 1395 annual simulations using the U.S. DOE detailed medium-sized reference office building, and 30 years' historical weather data in three typical climates including Miami, San Francisco, and Chicago. Three energy efficiency levels of the building and systems are considered. Assumptions regarding occupant movements, occupants' diverse temperature preferences, lighting, and MELs are adopted to reflect realistic building operations. A semantic building metadata schema - BRICK, is used to store the building metadata. The dataset is saved in a 1.2 TB of compressed HDF5 file. This dataset can be used in various applications, including building energy and load shape benchmarking, energy model calibration, evaluation of occupant and weather variability and their influences on building performance, algorithm development and testing for thermal and energy load prediction, model predictive control, policy development for reinforcement learning based building controls.

AlphaBuilding↗

Does Mixing Make Residential Ventilation More Effective?

Ventilation dilutes or removes indoor contaminants to reduce occupant exposure. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. The total ventilation rate is the most important factor in determining the exposure of occupants to given sources, but the zone- specific distribution of exhaust and supply air, and the mixing of ventilation air can have significant roles. Different types of ventilation systems will provide different amounts of mixing depending on several factors such as air leakage through the building envelope, air distribution systems and the location of sources and occupants. This paper reports recent results of investigations to determine the impact that air mixing has on exposures of residential occupants to prototypical contaminants of concern. Evaluations of existing field measurements and simulations reported in the literature are combined with new analyses to provide an integrated overview of the topic. The results show that for extreme cases additional mixing can be a significant factor but for typical homes looking at average exposures mixing is not helpful and can even make exposures worse.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of an Environmental Background Level of Sr-90 in Urine for the Hanford Bioassay Program Determination of an Environmental Background Level of Sr-90 in Urine for the Hanford Bioassay Program

During the decommissioning and maintenance of some of the facilities at the U.S. Department of Energy Hanford Site in Washington State, workers have potential for a 90Sr intake. However, because of worldwide radioactive fallout, 90Sr is present in our environment, and can be detectable in routine urine bioassay samples. It is important for the Hanford Site bioassay program to discern an occupational intake from a non-occupational environmental one. A detailed study of the background 90Sr in the urine of unexposed Hanford workers was performed. A survey of the Hanford Site bioassay database found 128 Hanford workers who were hired between 1997 and 2002 and who had a very low potential for an occupational exposure prior to the baseline strontium urinalysis. Each urinalysis sample represented excretion during an approximate 24-hr period. The arithmetic mean value for the 128 pre-exposure baselines was 3.6 ± 5.1 mBq d-1. The 90Sr activities in urine varied from -12 to 20 mBq. The 99th percentile result was 16.4 mBqd-1, which was interpreted to mean that 1% of Hanford workers not occupationally exposed to strontium might exceed 16.4 mBq d-1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of lure choice and survey duration on scent stations for carnivore surveys

Abstract Noninvasive, camera‐based, scent station surveys have become a common approach to estimate population parameters for mammalian carnivores. Many carnivores are particularly sensitive to olfactory cues; and, as such, the quality and quantity of odor attractant used during surveys can significantly affect the accuracy and precision of the survey. Additionally, survey length is also an important consideration because many mammalian predators are highly mobile and elusive in nature. Using scent station surveys in autumn 2013 and 2014 on the Savannah River Site, Aiken, South Carolina, USA, we tested the effects of 5 lures: fatty acid, fish oil, synthetic fermented egg, beaver castor, and skunk essence on visitation rates, visitation probability, and latency to visitation of multiple predator species. We also estimated occupancy probability for 2 carnivore species using different survey lengths to determine the effect of survey period on the precision of occupancy estimates. We found that skunk essence had greater visitation probability and visits than other lures evaluated. Species‐specific bait‐preference models revealed that raccoons ( Procyon lotor ) were more likely to visit skunk essence, and coyotes ( Canis latrans ) were less likely to visit fish oil as compared with fatty acid. Latency to visitation ranged from 104.7 to 112.1 hours and did not vary among scents. Longer survey durations resulted in more precise estimates of occupancy and detection probability. Our results suggest a wide range of scents commonly used for carnivore capture may perform as well as, or better than, fatty acid for noninvasive carnivore surveys. Further, study designs should carefully consider the duration of scent‐station surveys depending on the level of precision desired in estimates of occupancy and detection probability. © 2019 The Wildlife Society.

Webster, Sarah C.↗

A review of smart building sensing system for better indoor environment control

Here this paper aims to provide a systemic review of how indoor sensors influence in managing optimal energy saving, thermal comfort, visual comfort, and indoor air quality in the built environment. The optimal management of energy saving and occupant comfort plays a vital role in the built environment because the occupant's productivity and health are highly influenced by indoor environmental quality. In order to do this, there must be a functional sensing system that connects the environment variables (e.g., temperature) with building environmental control systems such as the heating, ventilation, and air-conditioning system. This paper starts with an overview of the importance of energy saving and occupant comfort in the built environment. It then discusses sensors and their importance in the built environment and reviews the different types of sensors, which explains them in terms of how they influence the indoor built environment and occupant productivity. The paper further explores the application of sensors in the built environment and analyzes this in terms of energy saving, thermal comfort, visual comfort, and indoor air quality. Following this, the data analysis is discussed in terms of data, information, and knowledge accrued from the sensors. Lastly, the paper discusses the future challenges for the improvement of building indoor environmental quality and energy saving by the application of sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗