Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Quantum advantage for noisy channel discrimination

Many quantum mechanical experiments can be viewed as multiround interactive protocols between known quantum circuits and an unknown quantum process. Fully quantum “coherent” access to the unknown process is known to provide an advantage in many discrimination tasks compared to when only incoherent access is permitted, but it is unclear if this advantage persists when the process is noisy. Here, we show that a quantum advantage can be maintained when distinguishing between two noisy single-qubit rotation channels. Numerical and analytical calculations reveal a distinct transition between the performance of fully coherent and fully incoherent protocols as a function of noise strength. Moreover, the size of the region of coherent quantum advantage shrinks inverse polynomially in the number of channel uses, and in an intermediate regime an improved strategy is a hybrid of fully coherent and fully incoherent subroutines. The fully coherent protocol is based on quantum signal processing, suggesting a generalizable algorithmic framework for the study of quantum advantage in the presence of realistic noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Ground Multi-Mission Low-Cost Optical Terminal (LCOT) for Free-Space Optical Communications

Once confined to the realm of laboratory experiments and theoretical papers, space-based laser communications (lasercomm) are on the verge of achieving mainstream status. Organizations from Facebook to NASA, and missions from cubesats to Orion are employing lasercomm to achieve gigabit communication speeds at mass and power requirements lower than that of traditional radio frequency (RF) methods. Since first demonstrating free-space optical communications services with Lunar Laser Communications Demonstration (LLCD) in 2013, NASA has invested in developing optical communications technologies and capabilities to enhancing its space communications networks. Along with evolving optical space terminals, NASA is also developing lasercomm grounds stations capable of meeting the rapidly increasing data volume demands of upcoming missions, from low-earth to lunar orbits and beyond and integrating these advanced capabilities into its Near-Space and Deep Space Networks. To meet this emerging need, the Low-Cost Optical Terminal (LCOT) project at NASA’s Goddard Space Flight Center (GSFC) is designing, building and validating a prototype for a flexible, multi-mission, and economical optical ground terminal that could be used as a blueprint for a global network of optical ground stations, capable of supporting a wide variety of missions. To date a major impediment to widespread adoption of laser communication has been the lack of an existing ground network infrastructure. A mission that wishes to take advantage of laser communication not only needs to invest in an optical space terminal, but it must also finance the creation of ground terminals to receive the downlink signal. This adds significant additional cost. Missions that do decide to incur the cost of financing a network of ground terminals end up building highly specialized optical receivers that are operable as receivers for that specific mission only. Significant Non-Recurring Engineering (NRE) cost is invested to build highly specialized one-of-a-kind ground terminals that go into storage after that particular mission is over. This is not an economical approach and does nothing to grow the number of optical ground stations available to future missions. In essence each mission that wants to take advantage of the benefits of lasercom has to start from scratch to provide a ground terminal network to support it. As long as this is the case, the cost for using laser communications will be too high for most missions to consider. LCOT intends to close this gap in technology by designing and developing a standard optical ground terminal design that is flexible enough to serve as a receiver for a wide range of future missions – a ground terminal that can be quickly reconfigured to receive downlinks at different wavelengths using different signal formats. Not only does LCOT have the industry-building objectives of utilizing commercial-off-the-shelf (COTS) components to the maximum extent possible, but also spurs the commercial development of other necessary lasercomm components not currently offered by industry. Finally, LCOT will give NASA scientists and engineers a facility where they can gain real-world experience with optical communications. It will give engineers a cost-effective way to try out new concepts and processes by providing the infrastructure for such testing. In this way it is hoped LCOT will serve as a stimulus for innovation in optical communications and speed its widespread adoption by future missions. The LCOT is comprised of five subsystems: Free-Space Optical, Transceiver, Amplifier, Monitor and Control, and Observatory Infrastructure. In August 2021, the LCOT team installed a 70 cm telescope, developed by Planewave Instruments that was optimized for optical communications. Free-Space Optical subsystem comprises of the telescope and its associated hardware, including a transmitter optical assembly, wide field cameras, two optical benches, and an adaptive optics subsystem. The transmit optical assembly, a unique concept design, is a cluster of four functionally independent transmit subassemblies located on the receive telescope. In addition to receiving optical signals and directing the expanded beam with high precision to the space terminal, it also performs tracking functions. The transmit optical assembly will support operations from Low Earth Orbit (LEO) through lunar and will be used as a template for industry manufacturing. The Optical Infrastructure subsystem is responsible for providing environmentally controlled shelters for LCOT equipment and various other systems. To maintain the safety and proper functionality of the telescope, a 16 ft Astrohaven clamshell dome procured which provides all-sky coverage without the need to rotate the dome. Additionally, Atmospheric Monitoring Assembly (AMA) will be part of optical infrastructure subsystem to ensure accurate performance of the LCOT. Like existing optical ground stations, LCOT will measure standard weather station parameters, infrared all sky image of cloud cover, and cloud height. LCOT, however, adds requirements for measuring night time seeing and, in the future, daytime seeing. Unlike other optical ground terminals, the LCOT is transceiver agnostic; user transceivers may be duplex transceivers, standalone receivers, or standalone transmitters with or without acquisition beacon functionality. As such, the LCOT project accommodates testing with external customer transceivers in a flexible manor, further complimenting its intended multi-mission goals. Another unique component of LCOT is the use of a new amplifier technology – the Very Large Mode Area (VLMA) amplifiers. This new technology allows LCOT to avoid the issues faced by previous laser communications ground terminals, gives users more flexibility and modular capability, and is capable of reaching an order of magnitude higher peak power than traditional High Power Optical Amplifiers (HPOA). One drawback of the VLMA HPOA approach is that the amplified light is output into free-space. The solution developed by LCOT is an optics train that couples the output of the VLMA amplifier into a short fiber for transport to the transmit telescopes with high efficiency. Like many of the LCOT components, a set of detailed manufacturing drawings have been created for the optics train to allow any machine shop with a multi-axis Computer Numerical Control (CNC) machine to fabricate the piece parts from commonly available materials. In line with the goals of LCOT, the monitor and control functions are developed as a modular and flexible system with the ability to support future hardware or algorithm changes, minimizing disruptions. A main priority of development in the Monitor and Control Subsystem (MCS) is the safety monitor system.

laser communication↗

Development of a Ground Multi-mission Low Cost Optical Terminal(LCOT) for Free-Space Optical Communication

Once confined to the realm of laboratory experiments and theoretical papers, space-based laser communications (lasercomm) are on the verge of achieving mainstream status. Organizations from Facebook to NASA, and missions from cubesats to Orion are employing lasercomm to achieve gigabit communication speeds at mass and power requirements lower than that of traditional radio frequency (RF) methods. Since first demonstrating free-space optical communications services with Lunar Laser Communications Demonstration (LLCD) in 2013, NASA has invested in developing optical communications technologies and capabilities to enhancing its space communications networks. Along with evolving optical space terminals, NASA is also developing lasercomm grounds stations capable of meeting the rapidly increasing data volume demands of upcoming missions, from low-earth to lunar orbits and beyond and integrating these advanced capabilities into its Near-Space and Deep Space Networks. To meet this emerging need, the Low-Cost Optical Terminal (LCOT) project at NASA’s Goddard Space Flight Center (GSFC) is designing, building and validating a prototype for a flexible, multi-mission, and economical optical ground terminal that could be used as a blueprint for a global network of optical ground stations, capable of supporting a wide variety of missions. To date a major impediment to widespread adoption of laser communication has been the lack of an existing ground network infrastructure. A mission that wishes to take advantage of laser communication not only needs to invest in an optical space terminal, but it must also finance the creation of ground terminals to receive the downlink signal. This adds significant additional cost. Missions that do decide to incur the cost of financing a network of ground terminals end up building highly specialized optical receivers that are operable as receivers for that specific mission only. Significant Non-Recurring Engineering (NRE) cost is invested to build highly specialized one-of-a-kind ground terminals that go into storage after that particular mission is over. This is not an economical approach and does nothing to grow the number of optical ground stations available to future missions. In essence each mission that wants to take advantage of the benefits of lasercom has to start from scratch to provide a ground terminal network to support it. As long as this is the case, the cost for using laser communications will be too high for most missions to consider. LCOT intends to close this gap in technology by designing and developing a standard optical ground terminal design that is flexible enough to serve as a receiver for a wide range of future missions – a ground terminal that can be quickly reconfigured to receive downlinks at different wavelengths using different signal formats. Not only does LCOT have the industry-building objectives of utilizing commercial-off-the-shelf (COTS) components to the maximum extent possible, but also spurs the commercial development of other necessary lasercomm components not currently offered by industry. Finally, LCOT will give NASA scientists and engineers a facility where they can gain real-world experience with optical communications. It will give engineers a cost-effective way to try out new concepts and processes by providing the infrastructure for such testing. In this way it is hoped LCOT will serve as a stimulus for innovation in optical communications and speed its widespread adoption by future missions. The LCOT is comprised of five subsystems: Free-Space Optical, Transceiver, Amplifier, Monitor and Control, and Observatory Infrastructure. In August 2021, the LCOT team installed a 70 cm telescope, developed by Planewave Instruments that was optimized for optical communications. Free-Space Optical subsystem comprises of the telescope and its associated hardware, including a transmitter optical assembly, wide field cameras, two optical benches, and an adaptive optics subsystem. The transmit optical assembly, a unique concept design, is a cluster of four functionally independent transmit subassemblies located on the receive telescope. In addition to receiving optical signals and directing the expanded beam with high precision to the space terminal, it also performs tracking functions. The transmit optical assembly will support operations from Low Earth Orbit (LEO) through lunar and will be used as a template for industry manufacturing. The Optical Infrastructure subsystem is responsible for providing environmentally controlled shelters for LCOT equipment and various other systems. To maintain the safety and proper functionality of the telescope, a 16 ft Astrohaven clamshell dome procured which provides all-sky coverage without the need to rotate the dome. Additionally, Atmospheric Monitoring Assembly (AMA) will be part of optical infrastructure subsystem to ensure accurate performance of the LCOT. Like existing optical ground stations, LCOT will measure standard weather station parameters, infrared all sky image of cloud cover, and cloud height. LCOT, however, adds requirements for measuring night time seeing and, in the future, daytime seeing. Unlike other optical ground terminals, the LCOT is transceiver agnostic; user transceivers may be duplex transceivers, standalone receivers, or standalone transmitters with or without acquisition beacon functionality. As such, the LCOT project accommodates testing with external customer transceivers in a flexible manor, further complimenting its intended multi-mission goals. Another unique component of LCOT is the use of a new amplifier technology – the Very Large Mode Area (VLMA) amplifiers. This new technology allows LCOT to avoid the issues faced by previous laser communications ground terminals, gives users more flexibility and modular capability, and is capable of reaching an order of magnitude higher peak power than traditional High Power Optical Amplifiers (HPOA). One drawback of the VLMA HPOA approach is that the amplified light is output into free-space. The solution developed by LCOT is an optics train that couples the output of the VLMA amplifier into a short fiber for transport to the transmit telescopes with high efficiency. Like many of the LCOT components, a set of detailed manufacturing drawings have been created for the optics train to allow any machine shop with a multi-axis Computer Numerical Control (CNC) machine to fabricate the piece parts from commonly available materials. In line with the goals of LCOT, the monitor and control functions are developed as a modular and flexible system with the ability to support future hardware or algorithm changes, minimizing disruptions. A main priority of development in the Monitor and Control Subsystem (MCS) is the safety monitor system.

Haleh Safavi↗

Optical Telescope System-Level Design Considerations for a Space-Based Gravitational Wave Mission

The study of the Universe through gravitational waves will yield a revolutionary new perspective on the Universe, which has been intensely studied using electromagnetic signals in many wavelength bands. A space-based gravitational wave observatory will enable access to a rich array of astrophysical sources in the measurement band from 0.1 to 100 mHz, and nicely complement observations from ground-based detectors as well as pulsar timing arrays by sampling a different range of compact object masses and astrophysical processes. The observatory measures gravitational radiation by precisely monitoring the tiny change in the proper distance between pairs of freely falling proof masses. These masses are separated by millions of kilometers and, using a laser heterodyne interferometric technique, the change in their proper separation is detected to approx. 10 pm over timescales of 1000 seconds, a fractional precision of better than one part in 10(exp 19). Optical telescopes are essential for the implementation of this precision displacement measurement. In this paper we describe some of the key system level design considerations for the telescope subsystem in a mission context. The reference mission for this purpose is taken to be the enhanced Laser Interferometry Space Antenna mission (eLISA), a strong candidate for the European Space Agency's Cosmic Visions L3 launch opportunity in 2034. We will review the flow-down of observatory level requirements to the telescope subsystem, particularly pertaining to the effects of telescope dimensional stability and scattered light suppression, two performance specifications which are somewhat different from the usual requirements for an image forming telescope.

LISA↗

Ferroelectric domain engineering by focused infrared femtosecond pulses

We demonstrate infrared femtosecond laser-induced inversion of ferroelectric domains. This process can be realised solely by using tightly focused laser pulses without application of any electric field prior to, in conjunction with, or subsequent to the laser irradiation. As most ferroelectric crystals like LiNbO{sub 3}, LiTaO{sub 3}, and KTiOPO{sub 4} are transparent in the infrared, this optical poling method allows one to form ferroelectric domain patterns much deeper inside a ferroelectric crystal than by using ultraviolet light and hence can be used to fabricate practical devices. We also propose in situ diagnostics of the ferroelectric domain inversion process by monitoring the Čerenkov second harmonic signal, which is sensitive to the appearance of ferroelectric domain walls.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ERRATUM: “Automated Transient Identification in the Dark Energy Survey” (2015, AJ, 150, 82)

Here, we describe an algorithm for identifying point-source transients and moving objects on reference-subtracted optical images containing artifacts of processing and instrumentation. The algorithm makes use of the supervised machine learning technique known as Random Forest. We present results from its use in the Dark Energy Survey Supernova program (DES-SN), where it was trained using a sample of 898,963 signal and background events generated by the transient detection pipeline. After reprocessing the data collected during the first DES-SN observing season (2013 September through 2014 February) using the algorithm, the number of transient candidates eligible for human scanning decreased by a factor of 13.4, while only 1.0% of the artificial Type Ia supernovae (SNe) injected into search images to monitor survey efficiency were lost, most of which were very faint events. Here we characterize the algorithm's performance in detail, and we discuss how it can inform pipeline design decisions for future time-domain imaging surveys, such as the Large Synoptic Survey Telescope and the Zwicky Transient Facility. An implementation of the algorithm and the training data used in this paper are available at at http://portal.nersc.gov/project/dessn/autoscan.

79 ASTRONOMY AND ASTROPHYSICS↗

STUDY OF THE SPECTRAL AND TEMPORAL CHARACTERISTICS OF X-RAY EMISSION OF THE GAMMA-RAY BINARY LS 5039 WITH SUZAKU

We report on the results from Suzaku broadband X-ray observations of the galactic binary source LS 5039. The Suzaku data, which have continuous coverage of more than one orbital period, show strong modulation of the X-ray emission at the orbital period of this TeV gamma-ray emitting system. The X-ray emission shows a minimum at orbital phase {approx}0.1, close to the so-called superior conjunction of the compact object, and a maximum at phase {approx}0.7, very close to the inferior conjunction of the compact object. The X-ray spectral data up to 70 keV are described by a hard power law with a phase-dependent photon index which varies within {gamma} {approx_equal} 1.45- 1.61. The amplitude of the flux variation is a factor of 2.5, but is significantly less than that of the factor {approx}8 variation in the TeV flux. Otherwise the two light curves are similar, but not identical. Although periodic X-ray emission has been found from many galactic binary systems, the Suzaku result implies a phenomenon different from the 'standard' origin of X-rays related to the emission of the hot accretion plasma formed around the compact companion object. The X-ray radiation of LS 5039 is likely to be linked to very high energy electrons which are also responsible for the TeV gamma-ray emission. While the gamma rays are the result of inverse Compton (IC) scattering by electrons on optical stellar photons, X-rays are produced via synchrotron radiation. Yet, while the modulation of the TeV gamma-ray signal can be naturally explained by the photon-photon pair production and anisotropic IC scattering, the observed modulation of synchrotron X-rays requires an additional process, the most natural one being adiabatic expansion in the radiation production region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Synchronized Sensor Array for Remote Monitoring of Avian and Bat Interactions with Offshore Renewable Energy Facilities

Wind energy production in the U.S. is projected to increase to 35% of our nation’s energy by 2050. This substantial increase in the U.S. is only a portion of the global wind industry growth, as many countries strive to reduce greenhouse gas emissions. A major environmental concern and potential market barrier for expansion of wind energy is bird and bat mortality from impacts with turbine blades, towers, and nacelles. Carcass surveys are the standard protocol for quantifying mortality at onshore sites. This method is imperfect, however, due to survey frequency at remote sites, removal of carcasses by scavengers between surveys, searcher efficiency, and other biases as well as delays of days to weeks or more in obtaining information on collision events. Furthermore, carcass surveys are not feasible at offshore wind energy sites. Near-real-time detection and quantification of interaction rates is possible at both onshore and offshore wind facilities using an onboard, integrated sensor package with data transmitted to central processing centers. We developed and experimentally tested an array of sensors that continuously monitors for interactions (including impacts) of birds and bats with wind turbines. The synchronized array includes three sensor nodes: (1) vibration (accelerometers and contact microphones), (2) optical (visual and infrared spectrum cameras), and (3) bioacoustics (acoustic and ultrasonic microphones). Accelerometers and contact acoustic microphones are placed at the root of each blade to detect impact vibrations and sound waves propagating through the structure. On-board data processing algorithms using wavelet analysis detect impact signals exceeding background vibration. Stereo-visual and infrared cameras were placed on the nacelle to allow target tracking, distance, and size calculations. On-board image processing and target detection algorithms identify moving targets within the camera field of view. Bioacoustic recorders monitor vocalizations and echolocations to aid in identifying organisms involved in interactions. Data from all sensors are temporarily stored in ring (i.e., circular) buffers with a duration varying by sensor type. Detection of target presence or impact by any of the sensors can trigger the archiving of data from all buffers for transmission to a central data processing center for evaluation and post-processing. This mitigates the risk of “data mortgages” posed by continual recording and minimizes personnel time required to manually review event data. We first conducted individual component tests at laboratories and field sites in Corvallis and Newport, Oregon, and Seattle and Sequim, Washington. We conducted additional component tests on research wind turbines at the North American Wind Research and Training Center, Mesalands Community College (MCC; General Electric 1.5 MW turbine), New Mexico, and the National Wind Technology Center, National Renewable Energy Laboratory (NREL; Controls Advanced Research Turbines 3 [CART 3] 600 kW Westinghouse turbine), Colorado. We conducted fully integrated system tests at NREL in October 2014 and April 2015. We used only research wind turbines so that we could conduct controlled, experimentally generated impacts using empty and water-filled tennis balls shot from a compressed air cannon on the ground. The approx. 57-140 g tennis balls (depending on water content) were at the upper mass range for bats, but lower mass range for marine birds. Therefore, the ability to detect collisions of most seabirds is likely greater than our experiments demonstrate, but possibly lower for some bats depending on the background signal of a given turbine. Vibration data demonstrated that background signals of operating turbines varied markedly among the CART 3 under normal operation (greatest), GE (moderate), and CART 3 during idle rotation (generator not engaged; least). In total, we measured 63 experimental blade impacts on the two research turbines. Impaction detection was dependent on background signals, position of impact on the blade (a tip strike resulted in the strongest impact signal), and impact kinetics (velocity of ball and whether the ball struck the surface of the blade or the leading edge of the blade struck the ball). Overall detection percentage ranged from 100% for the “quietest” conditions (CART 3 idle rotation), down to 35% for the noisiest (CART 3 normal operation). Impact signals were detected from sensors on more than one blade (i.e., blades other than the blade struck) 50% - 75% of the time. Stereo imaging provided valuable metrics, but increased data processing and equipment cost. Given the cost of cameras with sufficient resolution for target identification, we suggest mounting cameras directly on the blades to continuously view the entire rotor swept area with the fewest number of cameras. Bioacoustic microphones provide taxonomic identification, as well as information on ambient noise levels. They also assist in identifying environmental conditions such as hail storms, high winds, thunder, lightning, etc., that may contribute to a collision or a false positive detection. We demonstrated a proof of concept for an integrated sensor array to detect and identify bird and bat collisions with wind turbines. The next phase of research and development for this system will miniaturize and integrate sensors from all three nodes into a single wireless package that can be attached directly to the blade. This next generation system would use all “smart” sensors capable of onboard data processing to drastically reduce data streams and processing time on a central computer. A provisional patent for the blade mounted system was submitted by Oregon State University and recorded by the U.S. Patent and Trademark Office (application no. 62313028). Eventually, technology and industry advances will allow this low cost monitoring system to be designed into materials during manufacturing so that all turbines could be monitored with either a subset or full suite of sensors. As standard equipment on all commercial turbines, the sensor suite would allow the industry to effectively monitor whether individual turbines were causing mortalities or not and under what circumstances. It would also provide real-time evaluation of mechanical and structural integrity of a turbine via vibration, image, and acoustic data streams, thereby permitting modifications in operation to limit environmental or mechanical damage.

17 WIND ENERGY↗

On the theory of quantum measurement

Many so called paradoxes of quantum mechanics are clarified when the measurement equipment is treated as a quantized system. Every measurement involves nonlinear processes. Self consistent formulations of nonlinear quantum optics are relatively simple. Hence optical measurements, such as the quantum nondemolition (QND) measurement of photon number, are particularly well suited for such a treatment. It shows that the so called 'collapse of the wave function' is not needed for the interpretation of the measurement process. Coherence of the density matrix of the signal is progressively reduced with increasing accuracy of the photon number determination. If the QND measurement is incorporated into the double slit experiment, the contrast ratio of the fringes is found to decrease with increasing information on the photon number in one of the two paths.

Haus, Hermann A.↗

Deciphering the Spectra of Flowers to Map Landscape-scale Blooming Dynamics

Like leaves, floral coloration is driven by inherent optical properties, which are determined by pigments, scattering structure, and thickness. However, establishing the relative contribution of these factors to canopy spectral signals is usually limited to in-situ observations. Modeling flowering dynamics (e.g., blooming duration, spatial distribution) at the landscape scale may reveal insights into ecological processes and phenological adaptations to environmental changes. Multitemporal visible to shortwave infrared (VSWIR) imaging spectroscopy observations are especially suited for such efforts. Reflectance in this spectral range is sensitive to major flower pigments, flowering phenology traces, and biophysical differences between flowers and other plant parts. We explored how flowers contribute to spectral signals using a time series of imagery from the Airborne Visible InfraRed Imaging Spectrometer - Next Generation (AVIRIS-NG) collected as part of the SBG High-Frequency Time Series (SHIFT) campaign as a case study. Airborne data were collected weekly during the spring of 2022 across two natural reserves in California. Field spectra were gathered from blooming plots at leaf, flower, and canopy levels at two time points during the campaign. The processed data was used to investigate flowering species' spectro-temporal variation and spatial distribution using Spectral Mixture Residual, Gaussian clustering techniques, and a proposed narrow-band flowering index. Linear spectral unmixing allowed the computation of the weighted contribution of four major high-variance endmembers (leaves, flowers, soil, dark) and low-variance residual signal that comprises subtle spectral features used to track biophysical processes. The reflectance residual was projected on a low principal component basis to characterize flowering clusters' variation and spatial distribution based on the Gaussian mixture model, providing an uncertainty metric to assess the results. Mapping flowering events from modeling spectro-temporal dynamics throughout the season, from pre-blooming to post-flowering stages, allowed us to identify gradient variations in spectral features within the VSWIR spectral range linked to flowering pigments. Time series of the Mixture Residual Blooming Index and the Red-Edge Normalized Difference Vegetation Index revealed specific flowering and greenness phenophases across the two main species (Coreopsis gigantea, Artemisia californica) in the flowering areas. Overall, our approach opens opportunities for future satellite monitoring of floral cycles at broader scales.

Yoseline Angel↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection of Objects Hidden in Highly Scattering Media Using Time-Gated Imaging Methods

Non-intrusive and non-invasive optical imaging techniques has generated great interest among researchers for their potential applications to biological study, device characterization, surface defect detection, and jet fuel dynamics. Non-linear optical parametric amplification gate (NLOPG) has been used to detect back-scattered images of objects hidden in diluted Intralipid solutions. To directly detect objects hidden in highly scattering media, the diffusive component of light needs to be sorted out from early arrived ballistic and snake photons. In an optical imaging system, images are collected in transmission or back-scattered geometry. The early arrival photons in the transmission approach, always carry the direct information of the hidden object embedded in the turbid medium. In the back-scattered approach, the result is not so forth coming. In the presence of a scattering host, the first arrival photons in back-scattered approach will be directly photons from the host material. In the presentation, NLOPG was applied to acquire time resolved back-scattered images under the phase matching condition. A time-gated amplified signal was obtained through this NLOPG process. The system's gain was approximately 100 times. The time-gate was achieved through phase matching condition where only coherent photons retain their phase. As a result, the diffusive photons, which were the primary contributor to the background, were removed. With a large dynamic range and high resolution, time-gated early light imaging has the potential for improving rocket/aircraft design by determining jets shape and particle sizes. Refinements to these techniques may enable drop size measurements in the highly scattering, optically dense region of multi-element rocket injectors. These types of measurements should greatly enhance the design of stable, and higher performing rocket engines.

Galland, Pierre A.↗

Novel Electron-Bubble Tracking Detectors

Our Columbia group, in collaboration with Brookhaven and SMU, has been carrying out R&D on tracking detectors in cryogenic liquids, including neon and helium. A cryostat purchased by this Grant capable of working temperatures down to 1 K and pressures above the critical point of neon and helium has been operated with a variety of noble fluids. Gaseous Electron Multipliers (GEM) with hydrogen additives have been operated with tracks of radioactive sources read out both by electrical charge detecting electronics, and an optical camera purchased by this Grant, measuring mobility, charge yield, transitions through phase boundaries, gain limitations, and other properties. The goal is very high resolution in large volumes. The scope of the project is the provision of a high performance camera and its installation in a cryogenic facility providing pressure up to 40 atmospheres and a temperature from ambient down to about 1 K. In this section we will address the goals and results having to do with this project and particularly the performance of the camera, and provide a summary of the status of the detector project. The technical development of digital cameras has been dominated for the last forty years by the Charge-Coupled Device technology (CCD). This allows photon recording on very small pixels on silicon planes that provide high quantum efficiency in the visible spectrum, recording the charge generated by a single photon stored on one pixel with an area of order ten microns square. The area can be up to several centimeters squared, containing a million pixels or more. The stores charge is usually read out by manipulating voltage biases to shift the charge in each pixel over to the next, and eventually out of the array and sent to an external processor and memory. Mass production has brought the cost per channel down to very small values and allowed cameras to be integrated to many consumer products. Thermal noise becomes larger than one photon on a single pixel at good temperature, and demand night vision and other demanding applications has led to intense R&D over the years, and small coolers that maintain the CCD at temperatures of more than 100K below ambient are integrated into the camera package. These systems are sold in quantity to amateur astronomers with the same silicon devices used in professional systems, provided long exposure times with less than one electron noise per pixel. In our particle readout, we are imaging a three-dimensional track drifting into the readout plane over time, and we need to read out one plane after another, and we need a high rate of pixel processing. For many years, the noise in the electronic amplifier matching the CCD to the external electronics led to noise levels of many electrons, much higher than in the CCD itself. A break-through was made by providing signal gain inside the CCD, connecting to the external line, by a Electron Multiplier CCD, using a number of electron avalanche stages, each with a small, stable gain. This device was brought out just before out application for the present Grant, provided the last link in the development chain, which allowed out optical readout concept to be implemented at reason fact. In fact, we profited from the falling cost by delaying our order for about a year, which, together with the university discount, allowed us to proceed within our budget. The camera we purchase from the firm ANDOR, which introduced the technique, comes with an extensive suite of software that allows the fast readout with different integration times, and makes a very convenient use in our application. We have been able to make images of the light signals coming from out GEM electron avalanche detectors under many conditions, with tracks of different particle types. We have reconfigured the system a number of times, using the results from the camera to learn how to change the TPC drift geometry and the GEM charge amplifier to improve performance, a process that is still going on. The camera purchase with this Grant has performed reliably and just as specified by the manufacturer and has been a trouble-free element of our larger product. The ability of being able to vary the pressure and temperature over a wide range is very important for several reasons: (1) we are able to choose a fluid density to make the best compromise between a range of low energy tracks long enough to measure, and higher density to minimize the detector size for a given rate; (2) we can identify the density the allows the avalanche rate that provides sufficient signal to noise for the low-energy tracks we need to measure in a given application; and (3) we can operate at the optimum density and hydrogen admixture for light production. A special cryostat was required to operate down to 1 K with pressures up to 40 Bar, well above the critical point of Neon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Attosecond Nonlinear Optics

We report nonlinear multiphoton processes in atoms and molecules by intense high harmonics and their applications to attosecond pulse characterization. Phase matched high harmonics by a loosely focusing geometry produce highly focusable intensity with fully spatiotemporal coherence, which is sufficient to induce nonlinear optical phenomena in the extreme ultraviolet and soft x-ray (XUV) region. With this XUV coherent light source, two-photon double ionization in He is demonstrated with 42-eV high harmonic photons. On the other hand, when intense high harmonics around 20 eV is subjected to N{sub 2} molecules, occurrence of Coulomb explosion following to two-photon double ionization is observed in attosecond temporal precision. Taking advantage of larger cross section of two-photon ionization in molecules, we successfully perform the interferometric autocorrelation of an attosecond pulse train with the ion signals produced by Coulomb explosion of nitrogen molecules. The result reveals the phase relation between attosecond pulses in the train.

74 ATOMIC AND MOLECULAR PHYSICS↗

Incremental growth of short SWNT arrays by pulsed chemical vapor deposition

Very short, aligned arrays of continuous single wall carbon nanotubes were grown incrementally in steps as small as 25 nm using pulsed chemical vapor deposition. In situ optical extinction measurements indicate that over 98% of the nanotubes reinitiate growth on successive gas pulses, and HRTEM images show that the SWNTs do not exhibit segments, caps, or noticeable sidewall defects resulting from repeatedly stopping and restarting growth. Time-resolved laser reflectivity (3-ms temporal resolution) was used to record the nucleation and growth kinetics for each fast (0.2 second) gas pulse and measure the height increase of the array in situ, providing a "digital" method to incrementally grow short nanotube arrays to precise heights. Derivatives of the optical reflectivity signal reveal distinct temporal signatures for both nucleation and growth kinetics, with their amplitude ratio on the first gas pulse serving as a good predictor for aligned vs. unaligned growth. Incremental growth by pulsed CVD is interpreted in the context of autocatalytic kinetic models as a special processing window in which a sufficiently high flux of feedstock gas drives the nucleation and rapid growth phases of a catalyst nanoparticle ensemble to occur within the temporal period of the gas pulse, but without inducing growth termination.

36 MATERIALS SCIENCE↗

Near-infrared induced optical quenching effects on mid-infrared quantum cascade lasers

In space communications, atmospheric absorption and Rayleigh scattering are the dominant channel impairments. Transmission using mid-infrared (MIR) wavelengths offers the benefits of lower loss and less scintillation effects. In this work, we report the telecom wavelengths (1.55 μm and 1.3 μm) induced optical quenching effects on MIR quantum cascade lasers (QCLs), when QCLs are operated well above their thresholds. The QCL output power can be near 100% quenched using 20 mW of near-infrared (NIR) power, and the quenching effect depends on the input NIR intensity as well as wavelength. Time resolved measurement was conducted to explore the quenching mechanism. The measured recovery time is around 14 ns, which indicates that NIR generated electron-hole pairs may play a key role in the quenching process. The photocarrier created local field and band bending can effectively deteriorate the dipole transition matrix element and quench the QCL. As a result, MIR QCLs can be used as an optical modulator and switch controlled by NIR lasers. They can also be used as “converters” to convert telecom optical signals into MIR optical signals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pixelated scintillator array response to relativistic electrons

In order to make time resolved measurements of the gamma spectra on DARHT Axis 2 using the Compton Spectrometer (CS), the electron detector in the focal plane must be a scintillator that is optically coupled to a gated or streak camera. There are several issues we would like to address with experiments at Idaho Accelerator Center (IAC) before committing to a full size array (7”x2”), which would cost at least $100k. Two candidates for this application are organic (Bicron 422 or equivalent) or inorganic (LYSO) scintillator. Monte Carlo calculations were performed by Rachel Morneau, P-21, using MCNP to compare the two materials each 1.5mm thick for an energy range of 0.1 to 20MeV. The energy loss per particle in LYSO is much larger (100x) than in the plastic scintillator. We confirmed, by performing experiments with the CS on the Microton, that sensitivity of the LYSO was much larger (10x) than the plastic scintillator. Therefore, we have selected LYSO as the scintillator of choice. However, interest in the response of other organic and plastic scintillators prompted an increase in scope of the project. The goals of this experiment were as follows. First, we need to understand the optical response of the scintillators to electrons as a function of thickness, energy, and deposited charge. We also need to verify level of saturation in the scintillation process. Second, compare the scintillators’ response to an image plate (the current CS detector). Third, we need to quantify the effect of signal bleed through to adjacent pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber-optic rotation sensor technology

A concept for an all-waveguide fiber-optic rotation sensor is discussed, and the results of preliminary tests of key elements are described. A single channel waveguide coupler design provides the functions of an optical switch, a 3-dB beam splitter, a phase retarder, and a signal modulator, all of which may be formed on the same chip and interconnected by channel single-mode waveguides. Preliminary test results for the waveguide coupler and for a rotation sensor without the coupler are presented. Signal processing, polarization control, and interconnection of the waveguide components are discussed.

Goss, W. C.↗