Search NASA⌕ Search

SEARCH · Search NASA

Results for “Panelized”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Combination of natural fiber Boehmeria nivea (ramie) with matrix epoxide for bullet proof vest body armor

Ballistic protection equipment, such as a bulletproof vest, is a soldier’s most important means of preserving life and survivability in extreme combat conditions. The bulletproof vests are designed to protect the user’s chest from injury without disturbing the ability to perform his duties. Aromatic polyamide or aramid fibers known under the trade name Kevlar, Trawon and so is synthetic fiber materials commonly used in the manufacture of bulletproof vests. This synthetic fibers have high tensile strength and ductility. Kevlar is expensive and imported material. In this study, will introduce local natural raw materials, ramie fiber (Boehmeria nivea) which is cheaper and environmentally friendly. It has enough tenacity and tensile strength as a bulletproof vest. This experiment uses two panels, there are Panel A as front surface of Panel B. Panel A is a combination of ramie and epoxide matrix, while panel B is only ramie. From several variations of experimental combinations between Panel A and Panel B, optimal combination obtained with 16 layers of panel A and 31-34 layers of panel B which is able to protect againts cal. 7.65 mm × 17 mm (.32 ACP) bullet fired through pistol .32 Pindad from a distance of 20 meters. Panel with a size of 20 cm × 20 cm has a total thickness between 12,922 to13,745 mm and a total weight between 506,26 to 520,926gram. Scanning electron microscopy (SEM) observations indicated that the porosity and surface area of the ramie fiber is smooth, fiber surfaces showed topography with micropores. SEM also showed well-arranged structure of fibers bonding. Energy Dispersive X-ray (EDX) analysis indicated 100 % carbon contents in ramie fiber. Test result indicates that panel from composite ramie-epoxide can reach the level 1of International Standard of NIJ - 010104. Compared to panel from polyester fiber, the panel from composite ramie-epoxide (0,50-0,52 kg) is lighter weight than panel polyester fiber (1,642 kg)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Environmental and Financial Viability Analysis of Circular Economy Scenarios for Satisfying PV System Service Lifetime

PV deployment has grown rapidly in recent decades, and this growth is expected to continue. At the same time, the rapid increase in PV panel efficiencies offers the opportunity to repower/revamp existing installations - replacing operational, lower-efficiency panels before the end of their 30-year service lifetime with newer, higher-efficiency panels. As a result, an increasing volume of PV panels could be decommissioned well before reaching the end of their 30-year service lifetime. Two broad strategies can be applied to manage the expected increase in decommissioned PV panels: (i) recycle prematurely decommissioned panels, and (ii) prevent recycling of these panels by satisfying the typical service lifetime of 30 years through circular economy strategies such as repair and reuse. Each strategy presents an environmental and economic trade-off. Retaining and satisfying the lifetime of the older, lower-efficiency panels avoids environmental burdens from recycling or landfilling but incurs burdens from additional repair and forgoing the opportunity to install newer panels with greater electricity-generation capabilities. This study assesses whether satisfying the expected service lifetime of a PV system through circular economy scenarios generates a greater environmental and financial benefit than recycling used panels and installing newer panels with higher efficiencies. The circular economy scenarios include repair and reuse of the PV system. Specifically, the study determines whether it is better for the environment to keep a PV panel in use for its 30-year service life after accounting for potential repair and additional transportation, or to replace older panels with more efficient new ones. In addition, we explore whether satisfying the service lifetime of PV panels proves competitive with the recycling route from a financial perspective.

14 SOLAR ENERGY↗

Investigation of Flux Spreading in a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on increasing the operating temperatures to accommodate high efficiency power cycles and thermochemical processes. Inert solid particles as heat transfer media enable solar receivers to operate above 700 degrees Celsius resulting in increased system thermal efficiency compared to the conventional molten salt based CSP system. An open-cavity falling-particle solar receiver that can efficiently heat particles by direct heating from concentrated solar radiation faces challenges with large particle losses from wind and unable to support thermochemical reactions. A light-trapping, planar cavity reiver (LTPCR) where particles are indirectly heated can significantly minimize the particle losses during the operation, support thermochemical reactions, and offer scalability potential. The LTPCR features an array of vertical planar receiver/absorber panels arranged within a cavity configuration. Concentrated solar radiation from heliostats is focused onto the receiver walls, where heat is indirectly transferred to solid particles flowing inside the receiver channels. Heat transfer occurs through direct contact between the receiver panel walls and particles, and can be enhanced by fluidizing particles with air. This fluidization increases particle-wall contact and extends particle residence time, maximizing heat transfer efficiency. The unique vertical planar receiver structure originated from a near-blackbody tubular light absorber, effectively distributing the incoming solar beam spread across the panel walls and trapping light. This flux spreading effect, driven by cosine projection, converts high incident solar flux into a lower, more uniform heat flux on the panel walls. This redistribution enhances heat transfer efficiency between particle-wall or reaction gases-wall, while preventing localized overheating of the receiver panel. Indirect planar cavity solar receivers completely separate solid particles from the ambient environment that can greatly reduce the thermal losses in heated particles resulting in high efficiency at high temperatures above 700 degrees Celsius. This design ensures no particle losses to the environment during the operation while open-cavity designs can experience significant particle losses from wind. An experimental investigation was conducted to observe flux spreading on the receiver panel wall. A lab-scale prototype planar receiver, fabricated using Haynes 230 alloy, was tested under direct concentrated solar radiation using the high-flux solar furnace (HFSF) facility at NREL. The experiment was performed under normal peak radiative heat fluxes ranging from 800 to 1900 kW/m2. A temperature distribution on the panel wall was measured using a thermal imaging camera (FLIR A 6600). To prevent overheating at the receiver front tip, prism-shaped heat shields (Zircar UNIFROM C1) were placed in front of the receiver, and their influence on flux spreading was also studied. Absorbed flux distribution on the panel wall was modeled using SolTrace. The total solar power and flux distributions delivered from HFSF were determined based on the heliostat mirror optical properties, direct normal irradiance (DNI) on the on-sun testing days, peak flux measurement during the on-sun testing, and shutter/attenuator settings Due to the large incident angles of the solar beam on the panel wall, the angular optical properties of Haynes 230 alloy and Zircar heat shields were incorporated into the model. This flux distribution model was then integrated into a computational fluid dynamics (CFD) simulation to predict the receiver panel wall temperature, which was compared with the experimental measurements. Both prediction and measurements identified a temperature hotspot at the backside of the panel, indicating that the incident solar beam can fully reach to the rear of the receiver. The heat shields positioned at the front of the receiver effectively reduced the excessive temperature rise at the receiver front tip. Overall, the temperature was well distributed over the panel wall, with a minor hotspot at the back of the receiver. The model slightly overpredicted the temperature, possibly due to discrepancies in optical properties of the panel and an underprediction of thermal loss in the receiver. The advancement of the particle LTPCR offers a viable alternative to open-cavity receivers by addressing particle loss issues. Additionally, it presents a pathway for enabling solar thermochemical processes, extending CSP technology beyond power generation to fuel and chemical production.

14 SOLAR ENERGY↗

PERFORMANCE EVALUATION OF A SUSTAINABLE AND ENERGY EFFICIENT RE-ROOFING TECHNOLOGY USING FIELD-TEST DATA

Three test attics were constructed to evaluate a new sustainable method of re-roofing utilizing photo-voltaic (PV) laminates, metal roofing panels, and PCM heat sink in the Envelope Systems Research Apparatus (ESRA) facility in the ORNL campus. Figure 1 is a picture of the three attic roofs located adjacent to each other. The leftmost roof is the conventional shingle roof, followed by the metal panel roof incorporating the cool-roof coating, and third from left is the roof with the PCM. On the PCM roof, the PV panels are seen as well; they're labelled from left-to-right as panels 5, 6 and 7. The metal panel roof consists of three metal panels with the cool-roof coating; in further discussion this is referred to as the infrared reflective (IRR) metal roof. The IRR metal panels reflect the incoming solar radiation and then quickly re-emit the remaining absorbed portion, thereby reducing the solar heat gain of the attic. Surface reflectance of the panels were measured using a Solar Spectrum Reflectometer. In the 0.35-2.0 {mu}m wavelength interval, which accounts for more than 94% of the solar energy, the IRR panels have an average reflectance of 0.303. In the infrared portion of the spectrum, the IRR panel reflectance is 0.633. The PCM roof consists of a layer of macro-encapsulated bio-based PCM at the bottom, followed by a 2-cm thick layer of dense fiberglass insulation with a reflective surface on top, and metal panels with pre-installed PV laminates on top. The PCM has a melting point of 29 C (84.2 F) and total enthalpy between 180 and 190 J/g. The PCM was macro-packaged in between two layers of heavy-duty plastic foil forming arrays of PCM cells. Two air cavities, between PCM cells and above the fiberglass insulation, helped the over-the-deck natural air ventilation. It is anticipated that during summer, this extra ventilation will help in reducing the attic-generated cooling loads. The extra ventilation, in conjunction with the PCM heat sink, are used to minimize thermal stresses due to the PV laminates on sunny days. In PV laminates sunlight is converted into electricity and heat simultaneous. In case of building integrated applications, a relatively high solar absorption of amorphous silicon laminates can be utilized during the winter for solar heating purposes with PCM providing necessary heat storage capacity. However, PV laminates may also generate increased building cooling loads during the summer months. Therefore, in this project, the PCM heat sink was to minimize summer heat gains as well. The PCM-fibreglass-PV assembly and the IRR metal panels are capable of being installed directly on top of existing shingle roofs during re-roofing, precluding the need for recycling or disposal of waste materials. The PV laminates installed on the PCM attic are PVL-144 models from Uni-Solar. Each laminate contains 22 triple junction amorphous silicon solar cells connected in series. The silicon cells are of dimensions 356 mm x 239 mm (14-in. x 9.4-in.). The PVL-144 laminate is encapsulated in durable ETFE (poly-ethylene-co-tetrafluoroethylene) high light-transmissive polymer. Table 1 lists the power, voltage and current ratings of the PVL-144 panel.

14 SOLAR ENERGY↗

Long-term stability and mechanical characteristics of kV digital imaging system for proton radiotherapy

Purpose: To quantitatively evaluate the long-term image panel positioning stability and gantry angle dependence for gantry-mounted kV imaging systems. Methods: For patient setup digital imaging systems in isocentric rotating proton beam delivery facilities, physical crosshairs are commonly inserted into the snout to define the kV x-ray beam isocenter. Utilizing an automatic detection algorithm, the authors analyzed the crosshair center positions in 2744 patient setup kV images acquired with the four imagers in two treatment rooms from January 2012 to January 2013. The crosshair position was used as a surrogate for imaging panel position, and its long-term stability at the four cardinal angles and the panel flex dependency on gantry angle was investigated. Results: The standard deviation of the panel position distributions was within 0.32 mm (with the range of variation less than ± 1.4 mm) in both the X-Z plane and Y direction. The mean panel inplane rotations were not more than 0.51° for the four panels at the cardinal angles, with standard deviations ≤0.26°. The panel position variations with gantry rotation due to gravity (flex) were within ±4 mm, and were panel-specific. Conclusions: The authors demonstrated that the kV image panel positions in our proton treatment system were highly reproducible at the cardinal angles over 13 months and also that the panel positions can be correlated to gantry angles. This result indicates that the kV image panel positions are stable over time; the amount of panel sag is predictable during gantry rotation and the physical crosshair for kV imaging may eventually be removed, with the imaging beam isocenter position routinely verified by adequate quality assurance procedures and measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

Systems and methods for point-of-care positron emission tomography

A positron emission tomography (PET) system is provided. The system includes a first detector panel including a first array of detectors, a second detector panel including a second array of detectors, said second detector panel being moveable relative to a point between the first detector panel and the second detector panel, a tracking system configured to detect a position of said second detector panel relative to the first detector panel while imaging a subject, a computing device in communication with the first detector panel, the second detector panel, and the tracking system, the computing device configured to receive coincidence data from the first and second detector panels, receive position data from the tracking system, wherein each coincidence datum of the received coincidence data is associated with a unique position datum of the received position data, and reconstruct a plurality of images based on the received coincidence data and the received position data.

Tai, Yuan-Chuan↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗

Environmental Benefits of Closing the Solar Manufacturing and Recycling Loop: Preparation of Solar Manufacturing Inventories

The cumulative global solar panel waste stream is projected to reach between 60 and 78 million tonnes by 2050. Steps towards developing, demonstrating, and implementing processes that recover glass, metals, and semiconductor materials from end-of-life solar panels have already been taken. However, these processes result in the downcycling of most secondary solar materials. Critically, the costs and benefits of capturing these secondary materials for use in new solar panels are unknown. To evaluate the environmental benefit associated with solar material recycling and reuse in next generation panels, prior inventories must be updated and prepared for integration with recycling processes to examine the benefit of closing the material loop between solar panel end-of-life and new panel manufacturing. This current work describes steps taken to upgrade existing inventories that detail the manufacturing of cadmium-telluride (CdTe) panels from the Ecoinvent -v2.2 life cycle inventory database to Ecoinvent -v3. During this update, material inventories were modified to capture different realistic material supply chains within the constraints of Ecoinvent -v3. Materials discussed in detail in this work include primary flat glass, aluminum, steel, copper, and CdTe. This work demonstrated that environmental indicators such as embodied carbon, acidification, and terrestrial eutrophication associated with solar panel production can be reduced by 25% to over 40% through improved primary material sourcing.

CdTe solar panels↗

Real time intelligent process control system for thin film solar cell manufacturing

This project addresses the problem of lower solar conversion efficiency and waste in the typical solar cell manufacturing process. The work from the proposed development will lead toward developing a system which should be able to increase solar panel conversion efficiency by an additional 12-15% resulting in lower cost panels, increased solar technology adoption, reduced carbon emissions and reduced dependency on foreign oil. All solar cell manufacturing processes today suffer from manufacturing inefficiencies that currently lead to lower product quality and lower conversion efficiency, increased product cost and greater material and energy consumption. This results in slower solar energy adoption and extends the time solar cells will reach grid parity with traditional energy sources. The thin film solar panel manufacturers struggle on a daily basis with the problem of thin film thickness non-uniformity and other parameters variances over the deposited substrates, which significantly degrade their manufacturing yield and quality. Optical monitoring of the thin films during the process of the film deposition is widely perceived as a necessary step towards resolving the non-uniformity and non-homogeneity problem. In order to enable the development of an optical control system for solar cell manufacturing, a new type of low cost optical sensor is needed, able to acquire local information about the panel under deposition and measure its local characteristics, including the light scattering in very close proximity to the surface of the film. This information cannot be obtained by monitoring from outside the deposition chamber (as traditional monitoring systems do) due to the significant signal attenuation and loss of its scattering component before the reflected beam reaches the detector. In addition, it would be too costly to install traditional external in-situ monitoring systems to perform any real-time monitoring over large solar panels, since it would require significant equipment refurbishing needed for installation of multiple separate ellipsometric systems, and development of customized software to control all of them simultaneously. The proposed optical monitoring system comprises AccuStrata’s fiber optics sensors installed inside the thin film deposition equipment, a hardware module of different components (beyond the scope of this project) and our software program with iterative predicting capability able to control material bandgap and surface roughness as films are deposited. Our miniature fiber optics monitoring sensors are installed inside the vacuum chamber compartments in very close proximity where the independent layers are deposited (an option patented by us in 2003). The optical monitoring system measures two of the most important parameters of the photovoltaic thin films during deposition on a moving solar panel - material bandgap and surface roughness. In this program each sensor array consists of two fiber optics sensors monitoring two independent areas of the panel under deposition. Based on the monitored parameters and their change in time and from position to position on the panel, the system is able to provide to the equipment operator immediate information about the thin films as they are deposited. This DoE Supply Chain program is considered the first step towards the development of intelligent optical control system capable of dynamically adjusting the manufacturing process “on-the-fly” in order to achieve better performance. The proposed system will improve the thin film solar cell manufacturing by improving the quality of the individual solar cells and will allow for the manufacturing of more consistent and uniform products resulting in higher solar conversion efficiency and manufacturing yield. It will have a significant impact on the multibillion-dollar thin film solar market. We estimate that the financial impact of these improvements if adopted by only 10% of the industry ($7.7 Billion) would result in about $1.5 Billion in savings by 2015 (at the assumed 20% improvement). This can be achieved by optimizing the manufactured product and process in real time without changing the manufacturing technology.

14 SOLAR ENERGY↗

Designing Modules to Prevent Reverse Bias Degradation in Perovskite Solar Cells when Partial Shading Occurs

When a solar cell in a panel is shaded, the illuminated cells can place a large reverse bias on the shaded cell to attempt to force current through it. Although the panel can continue to produce power, the reverse bias can cause significant problems for the shaded cell. In the case of perovskite solar modules, Joule heating and irreversible electrochemical reactions will degrade the cell. Some photovoltaic technologies use bypass diodes to solve this problem. To prevent both a perovskite cell and an all-perovskite tandem cell from falling into reverse bias breakdown while shaded, no more than two cells per bypass diode are allowed, which is likely to be prohibitively expensive for many applications. Herein, how many solar cells can be protected by one bypass diode in single-junction and multijunction perovskite modules is explored. It is easier to incorporate bypass diodes into modules with singulated cells than with monolithic panels. It is shown that perovskite–silicon tandems can be protected with fewer bypass diodes than with single-junction perovskite modules. Furthermore, it is suggested that if bypass diodes cannot be feasibly incorporated, then the panels should be deployed in utility-scale power plants.

14 SOLAR ENERGY↗

Assessment of Clonal Expansion Using CarcSeq Measurement of Lung Cancer Driver Mutations and Correlation With Mouse Strain- and Sex-Related Incidence of Spontaneous Lung Neoplasia

Quantification of variation in levels of spontaneously occurring cancer driver mutations (CDMs) was developed to assess clonal expansion and predict future risk of neoplasm development. Specifically, an error-corrected next-generation sequencing method, CarcSeq, and a mouse CarcSeq panel (analogous to human and rat panels) were developed and used to quantify low-frequency mutations in a panel of amplicons enriched in hotspot CDMs. Mutations in a subset of panel amplicons, Braf, Egfr, Kras, Stk11, and Tp53, were related to incidence of lung neoplasms at 2 years. This was achieved by correlating median absolute deviation (MAD) from the overall median mutant fraction (MF) measured in the lung DNA of 16-week-old male and female, B6C3F1 and CD-1 mice (10 mice/sex/strain) with percentages of spontaneous alveolar/bronchioloalveolar adenomas and carcinomas reported in bioassay control groups. A total of 1586 mouse lung mutants with MFs > x 10-4 were recovered. The ratio of nonsynonymous to synonymous mutations was used to assess the proportion of recovered mutations conferring a positive selective advantage. The greatest ratio was observed in what is considered the most lung tumor-sensitive model examined, male B6C3F1 mice. Of the recurrent, nonsynonymous mouse mutations recovered, 55.5% have been reported in human tumors, with many located in or around the mouse equivalent of human cancer hotspot codons. MAD for the same subset of amplicons measured in normal human lung DNA samples showed a correlation of moderate strength and borderline significance with age (a cancer risk factor), as well as age-related cumulative lung cancer risk, suggesting MAD may inform species extrapolation.

Toxicology↗

Characterization of a multi-axis ion chamber array

Purpose: The aim of this work was to characterize a multi-axis ion chamber array (IC PROFILER; Sun Nuclear Corporation, Melbourne, FL USA) that has the potential to simplify the acquisition of LINAC beam data. Methods: The IC PROFILER (or panel) measurement response was characterized with respect to radiation beam properties, including dose, dose per pulse, pulse rate frequency (PRF), and energy. Panel properties were also studied, including detector-calibration stability, power-on time, backscatter dependence, and the panel's agreement with water tank measurements [profiles, fractional depth dose (FDD), and output factors]. Results: The panel's relative deviation was typically within ({+-}) 1% of an independent (or nominal) response for all properties that were tested. Notable results were (a) a detectable relative field shape change of {approx}1% with linear accelerator PRF changes; (b) a large range in backscatter thickness had a minimal effect on the measured dose distribution (typically less than 1%); (c) the error spread in profile comparison between the panel and scanning water tank (Blue Phantom, CC13; IBA Schwarzenbruck, DE) was approximately ({+-}) 0.75%. Conclusions: The ability of the panel to accurately reproduce water tank profiles, FDDs, and output factors is an indication of its abilities as a dosimetry system. The benefits of using the panel versus a scanning water tank are less setup time and less error susceptibility. The same measurements (including device setup and breakdown) for both systems took 180 min with the water tank versus 30 min with the panel. The time-savings increase as the measurement load is increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of Insulation Strategies of Cross-Laminated Timber Assemblies on Energy Use, Peak Demand, and Carbon Emissions

Cross-Laminated Timber (CLT) panels have many structural benefits but do not have much thermal resistance. We have developed a solution to insulate CLT structures that uses high-performance insulation panels that provide R-values up to R40/inch. The CLT panels are made of layers of wood laminates (three, five, seven or more). The solution replaces some of the wood laminates in the CLT production with the insulation panels in a staggered fashion so that the wood laminates maintain contact throughout the panel, ensuring the CLT panel’s structural integrity. The insulated CLT panels have factory-installed water-resistive barriers reducing the installation time by eliminating installing insulation and water-resistive barriers on site. Per simulations, the CLT/insulation panel achieved code-required insulation levels with commonly available insulation materials. The significance of the thermal mass of CLT/insulation hybrid building envelopes was quantified by comparing the whole building energy performance and peak demand of traditional low mass and CLT wall assemblies resulting in up to 7% reduction in peak demand for cooling in Knoxville, TN, in a multifamily building. Buildings contribute over 40 percent of carbon emissions. The proposed CLT/insulation hybrid building envelope addresses both operational and embodied carbon by having high thermal resistances due to the embedded insulation sections and eliminating the use of high embodied carbon materials such as steel and concrete. The carbon benefit is estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic generation and analysis of solar cell IV curves

A photovoltaic system includes multiple strings of solar panels and a device presenting a DC load to the strings of solar panels. Output currents of the strings of solar panels may be sensed and provided to a computer that generates current-voltage (IV) curves of the strings of solar panels. Output voltages of the string of solar panels may be sensed at the string or at the device presenting the DC load. The DC load may be varied. Output currents of the strings of solar panels responsive to the variation of the DC load are sensed to generate IV curves of the strings of solar panels. IV curves may be compared and analyzed to evaluate performance of and detect problems with a string of solar panels.

14 SOLAR ENERGY↗